Command Code 91 (Continued): MDE-3860E

Function Code 6: Set ATC


1 = Not Installed * Programming Quick
2 = Installed
Function Code 11: Set Totalizer
Reference Card
Function
1 = Not Installed *
2 = Installed (one per meter/side)
3 = Installed (one per inlet/unit) Software Versions
Function Code 12: Set Nozzle This card is intended for Encore™ 500 and Eclipse™ fueling units. For software
Activated Pump Handle versions refer to MDE-3804 Encore and Eclipse Service Manual.
1 = Not Installed *
2 = Installed
Function Code 13: Set Meter Type
1 = C++ Meter *
Security Code Entry
2 = LC Meter Level 1: 2222 Level 2: 1503 Level 3: 1309 Level 4: 0128

Command Code 92:


Set Side Exists
1 = Both Sides Exist * Pin Code Entry
2 = Side 1 Only Press ENTER after making selection in all Levels.
3 = Side 2 Only Press F1 to perform additional programming.
Press F2 to exit programming.
Command Code 93:
Set Cash/Credit at Dispenser
1 = No Cash/Credit *
2 = Side 1 Only
From Level 1:
3 = Side 2 Only Command Code 20:
4 = Both Sides Set PPU
Select Side 1,2 or 3 (both sides)
Command Code 94: Select Grade
Set Zero PPU Option Select Price Level (Cash/Credit)
1 = Disabled * Enter new PPU
2 = Enabled (Repeat for other Side, Grade and Price Level.)


Command Code 95: Command Code 22:


Purge Mode Set Preset Types and Values
(Software Version V1.6.00 on Higher) Preset Mode Function Code Preset Type
(Only for New Uncalibrated Units)
1 = 5 Button Preset 1 = Set Preset Type 1 = Money

2 = Incremental Preset 2 = Set Preset Amounts 2 = Volume

3 = PPP 3 = Set PPP ON/OFF 1 = ON, 0 = OFF

Command Code 24:


Set Operations Mode
1 = 2-Wire *
2 = Standalone
3 = IFSF
4 = M.O.C. CRIND (LON)
5 = IFSF + Ethernet
6 = 2-Wire + Ethernet
7 = 2-Wire Serial PPP (CRIND)

Command Code 25:


Set Allocation
*Default Select Grade
Enter Allocation (Default = 0, No Allocation)
(Repeat for other Grades)
Call Gilbarco Technical Support at: 1-800-743-7501
Gilbarco Inc. • 7300 W. Friendly Ave., P.O. Box 22087
Greensboro, NC 27420 • Phone # 336-547-5000 • Fax # 336-292-8871 * Default
http://www.gilbarco.com
© 2002 by Gilbarco Inc. All Rights Reserved.
Command Code 27: Command Code 43: Command Code 55: Command Code 77:
Review ATC PPU Blinking options Set Hose Pressurization Change PIN Code
1 = ON * 1 = OFF * Note: PIN Code MUST be entered twice
Function Code Option
2 = OFF 2 = ON after 2 Hours
Function Code Change PIN Code
1* Audit last transaction 3 = On after 1/2 Hour
Command Code 44:
1* Level 1
2 Display vol corr. factor PPU/Grade Mapping Command Code 56:
Refer to Service Manual MDE-3804 Set Stop Button Control 2 Level 2
3 Display fuel density 1 = Stops One Side ONLY *
Command Code 45: 2 = Stops Both Sides 3 Level 3
4 Display temperature
Set Lamp Test Time
Options = 1 to 9 Seconds (3 *) 4 Level 4
5 Gross volume totals Command Code 59:
System Cold Start
Command Code 46: Command Code 78:
6 Software version 0 = Normal *
Set Comma/Decimal Point Electronic Calibration
1 = Cold Start
7 Real time transaction 1 = Decimal Point * Refer to MDE-3804
2 = Comma Command Code 60:
8 Engineering audit Command Code 80:
Set Clock and Calendar
Command Code 47: Set Maximum Flow Rate
1 = Set Time (00.01 - 24.00)
Command Code 28: Set Reported Money Size Options: 1 -99 Units per Minute
2 = Set Date (MM DD YY)
Change First Level PIN 1 = Return 5 Digits * (Default = 10 Gallons or 40 Liters per
1 = 1st pass 2 = Return All 6 Digits Command Code 62: minute)
2 = 2nd pass Two-Wire Remapping Grade
3 = New PIN accepted Command Code 48: (For 3+0 Blender Grade Mapping)
Zero Previous Transaction 1 = Two-wire (1-2-3)* From Level 4:
1 = After Lamp Test * 2 = Other POS System (1-3-5) Command Code 90:
From Level 2: 2 = Before Lamp Test Set Unit Type
Command Code 40: Option: Unit Type
Command Code 49:
Set 2 wire ID (Pump number)
STP Controls
From Level 3: 1* = 1 Grade, 1 Hose MPD
Side 1 or 2 Command Code 71: 2 = 2 Grade, 2 Hose MPD
Function Code 1: Set STP Prestart
Number 1-16: * Side 1 = 7; Side 2 = 11 Set Volume Units 3 = 3 Grade, 3 Hose MPD
1 = OFF *
0 = None * 4 = 4 Grade, 4 Hose MPD
Command Code 41: 2 = ON
1 = US Gallons 5 = 2 Grade, 1 Hose MPD
Set PPU Options Function Code 2: Set STP Control
2 = Liters 6 = 3 Grade, 1 Hose MPD
1 = Turn on ONLY selected STP *
Level Code L1 Display L2 Display 3 = Imperial Gallons 7 = 3 Grade, 1 Hose + 1 MPD
2 = Turn on ALL STPs
8 = 3 Grade, 3 Hose Blender
1 (Default) From POS N/A 3 = Automatic Mode
Command Code 72: 9 = 3 Grade, 3 Hose Blender + 1
Command Code 51: Set Blend Ratios 12 = 2 Grade, 1 Hose Blender
2 L1 L2
Set Main Beeper 1 - 6 = Grade Selection 13 = 3 Grade, 1 Hose Blender
3 L2 L1 1 = ON * 0 -100% = Blend of LOW product 14 = 4 Grade, 1 Hose Blender


2 = OFF (No Default - MUST be programmed) 15 = 5 Grade, 1 Hose Blender


4 N/A From POS 16 = 2 Grade, 1 Hose Blender + 1


Command Code 52: Command Code 73: 17 = 3 Grade, 1 Hose Blender + 1
Command Code 42: Set VaporVac Alarms Set/Display Money totals 18 = 4 Grade, 1 Hose Blender + 1
Set Decimal Point Options 1 = ON * Select Side/Select Grade (1-6) 19 = 5 Grade, 1 Hose Blender + 1
2 = OFF Set Total (less than 250 gallons)
Function Command Code 91:
Display Option
Code Select Installed Options
Command Code 53: Command Code 74:
Main display money (see Set Time Outs (0 - 999 seconds) Set/Display Volume Totals (Self-Configuring)
1* Select Side/Select Grade (1 - 6) Function Code 1: Preset Type
next table for parameters)
Function 1 = No Keypad *
Code
Time Out Option (1-8 for Blenders)
2 Main display volume Display or Set Amount (when totals 2 = 5 Button Preset
1* Set Beeper (Default = 0) less than 250 gallons) 3 = Incremental Preset
3 PPU for calculations 4 = Programmable Pump Preset
4 PPU for display
2 Set Pre-Select (Default = 15) Command Code 75: Function Code 2: Push to Start
Set Fuel Density 1 = Not Installed
3 Set Dispenser (Default = 0) 0 = Default 2 = Installed
Option: Decimal Point
1 = XXXXXX 1 = Gasoline (730) Function Code 3: Set VaporVac
Command Code 54: 2 = Diesel (830)** 1 = Not Installed *
2 = XXXXX.X Set Slowdown Valve ** Deactivates VaporVac Pumps 2 = Installed
3 = XXXX.XX * Options are 0 - 99% Function Code 5: Set Push to Stop
4 = XXX.XXX (Default = 20%) 1 = Not Installed *
2 = Installed

* Default * Default * Default * Default