You are on page 1of 37

Datasheet

S12700 Series Agile Switches


Huawei S12700 series switches are core switches designed for next-generation high-quality
campus networks. These purpose-built switches help create a campus network that improves
user experiences, reduces operating costs, and delivers unmatched security a

Introduction
The S12700 uses a secure and reliable platform architecture for software systems, and uses a redundancy design for all key
components to ensure the security, reliability, and reliability of core nodes on the campus network. In addition to the industry-
leading data switching capability and massive terminal access capability, the solution also provides innovative features, such as
native AC, VXLAN, free mobility, intelligent HQoS, iPCA, and SVF, making it an ideal choice for building high-quality core
switches on campus networks in the Wi-Fi 6 era, facilitate global customers' digital transformation.

 Highly reliable CLOS architecture: The system control board and switching board are separated. SFUs are configured on
demand, reducing costs. In the future, SFUs can be upgraded to achieve smooth evolution of campus networks.
 Industry-leading native AC feature: The device can manage a maximum of 10,240 APs, implementing integrated
management of wired and wireless networks, reducing overall network construction costs and simplifying campus network O&M.
 Industry-leading free mobility features: refined policy management based on users and applications, users can enjoy
consistent service policies and experience anywhere, anytime, and any access mode.
 Leading CSS2 cluster architecture: Based on the innovative CSS2 hardware clustering technology, 1+N backup of MPUs
on modular core switches is implemented. A MPU failure does not affect service data exchange of the entire system.

Product Overview
Models and Appearance
The S12700 series is available in four models: S12704, S12708 and S12712. The switching capacity and port density of all four
models are expandable. The S12700 is based on a new hardware platform, which adopts a left-to-rear ventilation channel to
achieve better energy efficiency. Key components work in redundancy mode to minimize risks of system breakdown and service
interruption. Using innovative energy-saving chips, the S12700 provides an industry-leading solution for a sustainable energy-
saving network.

Models and appearances of the S12700 series

Appearance Description

S12700 Series Agile Switches 1


Appearance Description
 Number of Main Processing Unit (MPU) slots: 2
 Number of Switch Fabric Unit (SFU) slots: 2
 Number of Line Processing Unit (LPU) slots: 4
 Number of Centralized Monitoring Unit (CMU) slots: 2
 Number of fan slots: 2
 Number of power module slots: 4
 Dimensions (W x D x H, excluding rack-mounting brackets):
− With cable man·agement frames: 442 mm x 585 mm x 441.7 mm (10 U)
− Without cable management frames: 442 mm x 489 mm x 441.7 mm (10 U)
 Port density per chassis: 192 x FE, 192 x GE, 192 x 10GE, 64 x 40GE, 32 x
S12704
100GE
 Installation: The switch can be installed in an N66E or N68E cabinet, one
cabinet for one chassis.
 Forwarding performance: 3,120Mpps/4,560Mpps
 Switching capacity: 4.88Tbps/16.08Tbps

 Number of Main Processing Unit (MPU) slots: 2


 Number of Switch Fabric Unit (SFU) slots: 4
 Number of Line Processing Unit (LPU) slots: 8
 Number of Centralized Monitoring Unit (CMU) slots: 2
 Number of fan slots: 4
 Number of power module slots: 6
 Dimensions (W x D x H, excluding rack-mounting brackets):
− With cable management frames: 442 mm x 585 mm x 663.95 mm (15 U)
− Without cable management frames: 442 mm x 489 mm x 663.95 mm (15
U)
 Port density per chassis: 384 x FE, 384 x GE, 384 x 10GE, 128 x 40GE, 64 x
100GE
 Installation: The switch can be installed in an N66E or N68E cabinet, one
cabinet for one chassis.
 Forwarding performance: 6,240Mpps/30,240Mpps
S12708
 Switching capacity: 12.32Tbps/44.96Tbps

S12700 Series Agile Switches 2


Appearance Description
 Number of Main Processing Unit (MPU) slots: 2
 Number of Switch Fabric Unit (SFU) slots: 2
 Number of Line Processing Unit (LPU) slots: 4
 Number of Centralized Monitoring Unit (CMU) slots: 2
 Number of fan slots: 5
 Number of power module slots: 6
 Dimensions (W x D x H, excluding rack-mounting brackets):
− With cable management frames: 442 mm x 585 mm x 841.75 mm (19 U)
− Without cable management frames: 442 mm x 489 mm x 841.75 mm (19
U)
 Port density per chassis: 576 x FE, 576 x GE, 576 x 10GE, 192 x 40GE, 96 x
100GE
 Installation: The switch can be installed in an N66E or N68E cabinet, one
cabinet for one chassis.
 Forwarding performance: 9,120Mpps/30,240Mpps
 Switching capacity: 17.44Tbps/44.96Tbps

S12712

Cards
S12700 series switches come with a variety of cards, including MPUs, SFUs, related subcards, LPUs, and CMUs.

The following describe the different types of Line Processing Units (LPUs):

 The S series includes SA and SC, interface cards, for example, 12-port 10GBASE-X interface card (SA, SFP+).
 The E series includes EA, EC and EE interface cards, for example, 48-port 100M/1000M BASE-X interface card (EA, SFP).
 The X series includes X1E, X2E, X2S, X2H, X5E, X5S, and X5H interface cards, for example, 48-port 10/100/1000BASE-T
interface card (X1E, RJ45).

The following table lists the cards supported by the S12700.

Cards supported by the S12700

Card Type Card Name Card Description Card Series

Main control unit ET1D2MPUDC00 S12704/S12708/S12712 Main Processing Unit D -

LST7MPUA1000 S12700,Main Processing Unit A(Optional clock)

Subcard on the MPU LE0D00CKMA00 Clock pinch board-1588 -

SFU ET1D2SFUA000 S12704/S12708/S12712 Switch Fabric Unit A -

ET1D2SFUD000 S12708/S12712 Switch Fabric Unit D -

ET1D2SFUB000 S12700 Switch Fabric Unit B -

Subcard on the SFU EH1D2VS08000 8-port 10G Cluster Switching System Service Unit (SFP+) -

ET1D2VQ06000 6-Port 40GE Cluster Switching System Service Unit (QSFP+) -

Centralized EH1D200CMU00 Centralized Monitoring Unit -


monitoring unit

1000M interface LST7G48TX5E0 48-port 10/100/1000BASE-T interface card (X5E, M, RJ45) X5E

S12700 Series Agile Switches 3


Card Type Card Name Card Description Card Series
card(Electrical) LST7G48TX5S0 48-port 10/100/1000BASE-T interface card (X5S, M, RJ45) X5S

1000M interface LST7G48SX6S0 48-port 100/1000 BASE-X interface card (X6S,SFP) X6S
card(Optical)
LST7G48SX6E0 48-port 100/1000 BASE-X interface card (X6E,SFP) X6E

GE/10GE interface LST7X24BX6S0 24-port 10GE SFP+ interface and 24-port GE SFP interface X6S
card card (X6S,SFP+)

LST7X24BX6E0 24-port 10GE SFP+ interface and 24-port GE SFP interface X6E
card (X6E,SFP+)

10GE interface card LST7X48SX6S1 48-port 10GE SFP+ interface card (X6S,SFP+) X6S

LST7X48SX6E1 48-port 10GE SFP+ interface card (X6E,SFP+) X6E

40GE/100GE LST7C02BX6E0 2-port 100GE QSFP28 interface and 4-port 40GE QSFP28 X6E
interface card interface card (X6E,QSFP28)

100GE interface card LST7C06HX6S1 6-port 100GE QSFP28 interface card (X6S,QSFP28) X6S

LST7C06HX6E1 6-port 100GE QSFP28 interface card (X6E,QSFP28) X6E

To learn detailed specifications of S12700 switch cards, see the S12700 Series Switches Cards Datasheet.

Fan Module
The following table lists the fan module applicable to the S12700.

Switch chassis matching a fan module

Model Name Applied Switch Model

EH1M00FBX000 Wide-voltage 74 fan box The fan module can be installed in:
 Slots FAN1 and FAN2 in an S12704 chassis.

ET1MFBX00000 Wide-voltage 129 fan box The fan module can be installed in:
 Slots FAN1 to FAN4 in an S12708 chassis.
 Slots FAN1 to FAN5 in an S12712 chassis.

Wide-voltage 74 fan box


Technical specifications and functions of the fan module

Fan Module Technical Specifications


 Dimensions (W x D x H): 323.9 mm x 74.8 mm x 126.6 mm (12.8 in. x 2.9 in. x 5.0 in.)
 Number of fans: 2
 Weight: 1540±20 g
 Maximum power consumption: 116 W
 Maximum wind pressure: 691 Pa
EH1M00FBX000
 Maximum wind rate: 245 cubic feet per minute (CFM)
 Maximum noise: 70 dBA
 Operating voltage range: -30 V DC to -73 V DC
 Maximum wind rate: 28 cubic feet per minute (CFM)
 Environment specifications:

S12700 Series Agile Switches 4


Fan Module Technical Specifications
− Operating temperature: 0°C to 45°C (32°F to 113°F)
− Operating relative humidity: 5% RH to 95% RH (noncondensing)
− Storage temperature: -40°C to +70°C (-40°F to +158°F)
− Storage relative humidity: 5% RH to 95% RH (noncondensing)

The following table lists the functions of the fan module.

Functions of fan modules

Function Description

Hot swapping Supported


Other fan modules are not affected when you install or remove a fan module.

Automatic fan speed The S12704 series switches provide intelligent fan speed adjustment based on temperature in
adjustment each zone. The system monitors the temperature of key components, and adjusts the fan speed
based on temperature changes. This intelligent fan speed adjustment function ensures that the
system stays within the proper operating temperature range, and reduces power consumption
and noise.

Wide-voltage 129 fan box


Technical specifications and functions of the fan module

Fan Module Technical Specifications


 Dimensions (W x D x H): 323.9 mm x 65 mm x 126.6 mm (12.8 in. x 2.6 in. x 5.0 in.)
 Number of fans: 2
 Weight: 2.5 kg (5.51 lb)
 Maximum power consumption: 200 W
 Maximum wind pressure: 997.8 Pa
ET1MFBX00000
 Maximum wind rate: 600 cubic feet per minute (CFM)
 Maximum noise: 77 dBA
 Operating voltage range: -30 V DC to -73 V DC
 Maximum wind rate: 28 cubic feet per minute (CFM)
 Environment specifications:
− Operating temperature: 0°C to 45°C (32°F to 113°F)
− Operating relative humidity: 5% RH to 95% RH (noncondensing)
− Storage temperature: -40°C to +70°C (-40°F to +158°F)
− Storage relative humidity: 5% RH to 95% RH (noncondensing)

The following table lists the functions of the fan module.

Functions of fan modules

Function Description

Hot swapping Supported


Other fan modules are not affected when you install or remove a fan module.

Intelligent fan speed The S12708 and S12712 series switches provide intelligent fan speed adjustment based on
adjustment temperature in each zone, and correlate speeds of fans in the entire chassis. The system
monitors the temperature of key components, and adjusts the fan speed based on temperature
changes. This intelligent fan speed adjustment function ensures that the system stays within the
proper operating temperature range, and reduces power consumption and noise.

S12700 Series Agile Switches 5


Power Supply
The S12704 provide slots PWR1 to PWR4 for power modules. The S12708 and S12712 provides slots PWR1 to PWR6 for
power modules.

AC and DC power modules cannot be used in the same chassis.

The S12700 series switches support three redundancy modes of power modules: N+N, N+1, and N+0. The value of N depends
on the maximum power actually required by the system. Ensure that the total maximum output power of N power modules (N x
maximum output power of each power module) is larger than the maximum power actually required by the system.

For example, the maximum power required by the system is 4000 W. If two 2200 W power modules are installed in the chassis,
they work in 2+0 mode. If three 2200 W power modules are installed, they work in 2+1 redundancy mode. If four 2200 W power
modules are installed, they work in 2+2 redundancy mode. The system can identify the power redundancy mode, and you do
not need to manually configure the power redundancy mode.

The following table lists the power supplies applicable to the S12700.

Technical specifications of the power supplies applicable to the S12700 series

Power Module Technical Specifications Applied Switch Model


 Dimensions (W x D x H): 41 mm x 393 mm x 130 mm (1.6 in. x  S12704
15.5 in. x 5.1 in.)
 Weight: <2.5 kg
 Input:
− Rated input voltage: 220 V AC/110 V AC; 50/60 Hz
− Rated input voltage range: 200 V AC to 240 V AC (220 V AC
W2PSA0800 input)/100 V AC to 120 V AC (110 V AC input); 47 Hz to 63
Hz
− Maximum input voltage range: 90 V AC to 290 V AC; 47 Hz
to 63 Hz (When the input voltage is in the range of 90 V AC
to 175 V AC, the power module provides up to half of the
maximum output power.)
− Maximum input current: 5 A
 Output:
− Maximum output current: 15 A (220 V AC input)/7.5 A (110 V
AC input)
− Maximum output power: 800 W (220 V AC input)/400 W
(110 V AC input)
 Hot swap: Supported
 Environment specifications:
− Operating temperature: 0°C to 45°C (32°F to 113°F)
− Operating relative humidity: 5% RH to 95% RH
(noncondensing)
− Storage temperature: -40°C to +70°C (-40°F to +158°F)
− Storage relative humidity: 5% RH to 95% RH
(noncondensing)

S12700 Series Agile Switches 6


Power Module Technical Specifications Applied Switch Model
 Dimensions (W x D x H): 41 mm x 417.4 mm x 130 mm (0.2 in.  S12704
x 16.4 in. x 5.1 in.)  S12708
 Weight: <3.0 kg  S12712
 Input:
− Rated input voltage: 220 V AC/110 V AC; 50/60 Hz
− Rated input voltage range: 200 V AC to 240 V AC (220 V AC
input)/100 V AC to 130 V AC (110 V AC input); 47 Hz to 63
PAC3KS54-NE Hz
− Maximum input voltage range: 90 V AC to 290 V AC; 47 Hz
to 63 Hz (The maximum output power reduces by a half
when the input voltage is in the range of 90 V AC to 175 V
AC.)
NOTE
The maximum current of the power cable used by the 3000 W
AC power module is 16 A. When the 220 V input is used, the
minimum voltage cannot be lower than 200 V. When the 110 V
input is used, the minimum voltage cannot be lower than 100 V.
− Maximum input current: 16 A
 High-voltage DC input:
− Rated input voltage: 240 V DC
− Rated input voltage range: 190 V DC to 290 V DC
− Maximum input current: 14 A
 Output:
− Maximum output current: 56.1 A (220 V AC input)/28.1 A
(110 V AC Input)
− Maximum output power: 3000 W (220 V AC input or 240 V
DC)/1500 W (110 V AC input)
 Hot swap: Supported
 Environment specifications:
− Operating temperature: 0°C to 45°C (32°F to 113°F)
− Operating relative humidity: 5% RH to 95% RH
(noncondensing)
− Storage temperature: -40°C to +70°C (-40°F to +158°F)
− Storage relative humidity: 5% RH to 95% RH
(noncondensing)

Product Highlights
Make Your Network Agile and Service-Oriented
The S12700's flexible packet processing and traffic control capabilities can meet current and future service requirements,
helping build a highly scalable network.

In addition to providing all the capabilities of common switches, the S12700 series provides fully programmable open interfaces
and supports programmable forwarding behaviors. Enterprises can use the open interfaces to develop new protocols and
functions independently, or jointly with other vendors, to build campus networks that meet their needs.

The ENP chip uses a fully programmable architecture, on which enterprises can define their own forwarding models, forwarding
behaviors, and lookup algorithms. This architecture speeds service innovation and enables the provisioning of a customized
service within six months, without replacing hardware. In contrast, traditional Application Specific Integrated Circuit (ASIC) chips

S12700 Series Agile Switches 7


use a fixed forwarding architecture and follow a fixed forwarding process. For this reason, new services cannot be provisioned
until new hardware is developed to support the services, which can take one to three years.

Deliver Abundant Services Agilely


The S12700 series' native AC capabilities allow enterprises to build a wireless network without additional AC hardware. Each
S12700 switch can manage up to 10K APs. It is a core switch that provides up to 4 Tbit/s AC capabilities, avoiding the
performance bottleneck on independent AC devices. The native AC capabilities help organizations better cope with challenges
in the high-speed wireless era.

The S12700 series' unified user management function authenticates both wired and wireless users, ensuring a consistent user
experience no matter whether they are connected to the network through wired or wireless access devices. The unified user
management function supports various authentication methods, including 802.1x, MAC address, and Portal authentication, and
is capable of managing users based on user groups, domains, and time ranges. These functions control user and service
management and enable the transformation from device-centered management to user-centered management.

The S12700 series' Service Chain function can virtualize value-added service capabilities, such as next-generation firewall.
Then these capabilities can be used by campus network entities (such as switches, routers, AC, AP, and terminals), regardless
of their physical locations. Service Chain provides a more flexible value-added service deployment solution, which reduces
equipment investment and maintenance costs.

The S12700 series supports IEEE 1588v2 and Synchronous Ethernet (SyncE), meeting the high-precision synchronization
requirements of network systems.

Provide Agile Fine Granular Management


Open Intelligent Diagnosis System (OIDS) integrates the device health monitoring and fault diagnosis functions – that are
typically deployed on a Network Management System (NMS) – into the switch software to implement intelligent diagnosis on a
single switch. After OIDS is deployed on a switch, the switch periodically collects and records the running information and
automatically determines whether a fault occurs. If a fault occurs, the switch automatically locates the fault or helps locate the
fault. All these merits increase fault locating efficiency of O&M staff while improving device maintainability.

Packet Conservation Algorithm for Internet (iPCA) changes the traditional method that uses simulated traffic for fault location.
iPCA technology monitors network quality for any service flow at any network node, at any time, and without extra costs. It can
detect temporary service interruptions within one second and can identify faulty ports accurately. This cutting-edge fault
detection technology turns "extensive management" into "fine granular management."

Super Virtual Fabric 2.0 (SVF 2.0) technology can not only virtualize fixed-configuration switches into S12700 switch line cards
but also virtualize APs as switch ports. With this virtualization technology, a physical network with core/aggregation switches,
access switches, and APs can be virtualized into a "super switch", offering the innovative network management solution.

The S12700 series manages access switches in a similar way an AC manages APs, saving the trouble of laborious
configuration on access switches. It manages access switches and APs uniformly through CAPWAP tunnels, allowing access
switches and APs to connect to the network with zero configuration.

Industry-leading Line cards


Using Huawei’s advanced ENP chips, the S12700 series supports several million hardware entries, leaving traditional switches
far behind. The S12700 series provides 1M MAC address entries and 3M Forwarding Information Base (FIB) entries, meeting
requirements of route-intensive scenarios, such as the Metropolitan Area Network (MAN) for a television broadcasting or
education network. Providing 1M NetStream entries enables fine granular traffic statistics for college campus networks and
large-scale enterprise campus networks.

The S12700 series provides large buffer on line card to prevent packet loss upon traffic bursts, delivering high-quality video
services.

The S12700 series supports high-density cards, such as 48 x 10 GE, 16 x 40GE and 8 x 100GE cards. Each S12700 chassis
can provide a maximum of 576 x 10 GE ports, 192 x 40G ports and 96 x 100GE ports. This large port capacity fully meets the
requirements of bandwidth-consuming applications, such as multimedia video conferencing, protecting customer investments.

S12700 Series Agile Switches 8


Device-Level Reliability: CSS2 Switch Fabric Hardware Clustering Technology
Based on back-to-back clustering technology, widely used on high-end core routers, the S12700 series employs second-
generation switching fabric hardware clustering technology, CSS2, an enhancement to CSS switching fabric clustering
technology.

CSS2 technology connects cluster member switches through switch fabric unit hardware channels; therefore, cluster control and
data packets need only be forwarded once by the switch fabric units and do not go through service cards. Compared with
traditional service port clustering technologies, CSS2 minimizes the impact of software failures, reduces service interruption
risks caused by service cards, and also significantly shortens transmission latency.

CSS2 supports 1+N backup of MPUs. This means a cluster can run stably as long as one MPU of any chassis in the cluster is
working normally. In a cluster connected by service ports, each chassis must have at least one MPU working normally; therefore,
CSS2 is more reliable than traditional service port clustering technologies.

Network-Level Reliability: End-to-End Hardware Protection Switching


The S12700 uses a series of link detection and protection switching technologies, such as hardware Eth-OAM, BFD, G.8032,
and Smart Ethernet Protection (SEP), to realize end-to-end protection switching. These technologies help build a campus
network that responds quickly to topology changes and provides the most reliable services.

The S12700 supports High-speed Self Recovery (HSR) technology. Using Huawei's ENP cards, the S12700 implements end-to-
end IP MPLS bearer network protection switchover within 50 ms, improving network reliability.

Comprehensive Security Measures


The S12700 supports MAC security (MACSec) that enables hop-by-hop secure data transmission. Therefore, the S12700 can
be applied to scenarios that pose high requirements on data confidentiality, such as government and finance sectors.

NGFW is a next-generation firewall card that can be installed on an S12700. In addition to the traditional defense functions such
as firewall, identity authentication, and Anti-DDoS, the NGFW supports IPS, anti-spam, web security, and application control
functions.

The S12700 provides innovative next-generation environment awareness and access control. It identifies the application-layer
attacks and protects network-layer applications based on application type, content, time, user, threaten, and location.

The dedicated software and hardware platforms provide an Intelligent Aware Engine (IAE) to perceive application information
when all security functions are enabled. The built-in hardware accelerator for content detection improves application-layer
protection efficiency and ensures the 10G+ performance when all security functions are enabled.

VXLAN
VXLAN is used to construct a Unified Virtual Fabric (UVF). As such, multiple service networks or tenant networks can be
deployed on the same physical network, and service and tenant networks are isolated from each other. This capability truly
achieves 'one network for multiple purposes'. The resulting benefits include enabling data transmission of different services or
customers, reducing the network construction costs, and improving network resource utilization. The S12700 series switches
are VXLAN-capable and allow centralized and distributed VXLAN gateway deployment modes. These switches also support the
BGP EVPN protocol for dynamically establishing VXLAN tunnels and can be configured using NETCONF/YANG.

High-Performance VRP Software System


 Huawei S series switches build on a unified Versatile Routing Platform (VRP) software system, meeting the growing
network scale and the evolving Internet technologies and guaranteeing network services and network quality.
 VRP is a network operating system developed by Huawei with independent intellectual property rights. It can run on
multiple hardware platforms and provide unified network, user, and management views. VRP provides flexible application
solutions for users. In addition, VRP is a future-proof platform that maximally protects customer investments.
 The VRP platform is focused on IP services and uses a component-based architecture to provide more than 300 features.
Besides, VRP stands out for its application-based tailorable and scalable capabilities.

OPS
Open Programmability System (OPS) is an open programmable system based on the Python language. IT administrators can
program the O&M functions of a switch through Python scripts to quickly innovate functions and implement intelligent O&M.

S12700 Series Agile Switches 9


Big Data Security Collaboration
The S12700 uses NetStream to collect campus network data and then report such data to the Huawei HiSec Insight. The
purposes of doing so are to detect network security threats, display the security posture across the entire network, and enable
automated or manual response to security threats. The HiSec Insight delivers the security policies to the iMaster NCE-
Campus(or Agile Controller). The iMaster NCE-Campus(or Agile Controller) then delivers such policies to switches that will
handle security events accordingly. All these ensure campus network security.

Intelligent Diagnosis
Open Intelligent Diagnosis System (OIDS) integrates the device health monitoring and fault diagnosis functions – that are
typically deployed on a Network Management System (NMS) – into the switch software to implement intelligent diagnosis on a
single switch. After OIDS is deployed on a switch, the switch periodically collects and records the running information and
automatically determines whether a fault occurs. If a fault occurs, the switch automatically locates the fault or helps locate the
fault. All these merits increase fault locating efficiency of O&M staff while improving device maintainability.

Licensing
The S12700 supports both the traditional feature-based licensing mode and the latest Huawei IDN One Software (N1 mode for
short) licensing mode. The N1 mode is ideal for campus network deployments in enterprise private cloud mode, and greatly
enhances the customer experiences in purchasing and upgrading software services with simplicity.

Software Package Features in N1 Mode

Switch Functions N1 Basic N1 Foundation N1 Advanced


Software Software Software
Package Package

Basic network functions: √ √ √


Layer 2 functions, IPv4, IPv6, MPLS, SVF, and others

Basic network automation based on the Agile × √ √


Controller:
 Basic automation: Plug-and-play, SSID, and AP
group management
 Basic monitoring: Application visualization
 NE management: Image and topology
management and discovery
 WLAN enhancement: Roaming and optimization
for up to 128 APs

Advanced network automation and intelligent × × √


O&M:
VXLAN, user access authentication, free mobility, and
CampusInsight basic functions

Note: Only V200R019C00 and later versions can support N1 mode

Product Specifications
Functions and Features
The following table lists the functions and features available on the S12700.

Function and feature metrics for the S12700 series

Function and Feature Description S12704 S12708 S12712

S12700 Series Agile Switches 10


Function and Feature Description S12704 S12708 S12712

System OS basics File upload and download Yes Yes Yes


basics
File system Yes Yes Yes

Directory and file management Yes Yes Yes

SVF SVF 2.0 virtualization Yes Yes Yes

Number of clients virtualized into Up to 4K Up to 4K Up to 4K


a single device

Two layers of ASs allowed in an Yes Yes Yes


SVF system

Third-party devices allowed Yes Yes Yes


between SVF parent and clients

Clustering Service port-based clustering Yes Yes Yes

CSS card-based clustering Yes Yes Yes

Interface Jumbo frames Yes Yes Yes


basics
Port bridge Yes Yes Yes

Load balancing among links of a Yes Yes Yes


trunk

Full-duplex, half-duplex, and Yes Yes Yes


auto-negotiation

Flow control on an interface Yes Yes Yes

Rate auto-negotiation on an Yes Yes Yes


interface

Link aggregation Yes Yes Yes

Configurati SSH v1.5 Yes Yes Yes


on
manageme SSH v2.0 Yes Yes Yes
nt
Console terminal services Yes Yes Yes

SNMPv1 Yes Yes Yes

SNMPv2c Yes Yes Yes

SNMPv3 Yes Yes Yes

Data communication between Yes Yes Yes


terminal users

Telnet/SSH terminal services Yes Yes Yes

Hierarchical user rights Yes Yes Yes


management and commands

Alarm information output Yes Yes Yes

Command line interface (CLI)- Yes Yes Yes


based configuration

SNMP-based NMS for unified Yes Yes Yes


configuration

S12700 Series Agile Switches 11


Function and Feature Description S12704 S12708 S12712

Log information output Yes Yes Yes

Messages and help information Yes Yes Yes


in English

Debugging information output Yes Yes Yes

Upgrade Version upgrade Yes Yes Yes


and
rollback Version rollback Yes Yes Yes

Hardware Hardware monitoring Yes Yes Yes


manageme
nt Energy saving Yes Yes Yes

Ethernet GVRP GARP Yes Yes Yes


basics
GVRP Yes Yes Yes

LAN VLAN mapping Yes Yes Yes


tunneling
Transparent transmission of Yes Yes Yes
Layer 2 protocol packets

Adding double VLAN tags to Yes Yes Yes


packets based on interfaces

Selective QinQ Yes Yes Yes

LAN MAC address flapping detection Yes Yes Yes


security
Sticky MAC Yes Yes Yes

Broadcast traffic suppression in a Yes Yes Yes


VLAN

Unknown unicast traffic Yes Yes Yes


suppression in a VLAN

Multicast traffic suppression in a Yes Yes Yes


VLAN

Storm control on broadcast, Yes Yes Yes


multicast, and unknown unicast
traffic

Limiting the number of MAC Yes Yes Yes


addresses that an interface can
learn

Interface security Yes Yes Yes

Broadcast traffic suppression on Yes Yes Yes


an interface

Unknown unicast traffic Yes Yes Yes


suppression on an interface

Multicast traffic suppression on Yes Yes Yes


an interface

Interface isolation Yes Yes Yes

Configuring MAC address Yes Yes Yes


learning priorities for interfaces

S12700 Series Agile Switches 12


Function and Feature Description S12704 S12708 S12712

MAC MAC address entries 4K 4K 4K


manageme
nt Automatic learning of MAC Yes Yes Yes
addresses

Automatic aging of MAC Yes Yes Yes


addresses

Static, dynamic, and blackhole Yes Yes Yes


MAC address entries

VLAN VLAN specification 4094 4094 4094


manageme
nt Access mode Yes Yes Yes

Trunk mode Yes Yes Yes

Hybrid mode Yes Yes Yes

QinQ mode Yes Yes Yes

Default VLAN Yes Yes Yes

MUX VLAN Yes Yes Yes

Super-VLAN Yes Yes Yes

Voice VLAN Yes Yes Yes

VLAN assignment based on IP Yes Yes Yes


subnets

VLAN assignment based on MAC Yes Yes Yes


addresses

VLAN assignment based on MAC Yes Yes Yes


address + IP address

VLAN assignment based on MAC Yes Yes Yes


address + IP address + interface
number

VLAN assignment based on Yes Yes Yes


protocols

VLAN assignment based on Yes Yes Yes


interfaces

Ring BPDU protection Yes Yes Yes


network
protocol DLDP Yes Yes Yes

ERPS semi-ring topology Yes Yes Yes

ERPS closed-ring topology Yes Yes Yes

G.8032 v1 Yes Yes Yes

G.8032 v2 Yes Yes Yes

MSTP Yes Yes Yes

Monitor Link Yes Yes Yes

RRPP Yes Yes Yes

S12700 Series Agile Switches 13


Function and Feature Description S12704 S12708 S12712

Single RRPP ring Yes Yes Yes

Hybrid networking of RRPP rings Yes Yes Yes


and other rings

Intersecting RRPP ring Yes Yes Yes

Tangent RRPP ring Yes Yes Yes

RSTP Yes Yes Yes

Smart Ethernet Protection (SEP) Yes Yes Yes

STP Yes Yes Yes

Smart Link Yes Yes Yes

Smart Link multi-instance load Yes Yes Yes


balancing

Root protection Yes Yes Yes

Loop protection Yes Yes Yes

Loop detection on an interface Yes Yes Yes

Defense against TC BPDU Yes Yes Yes


attacks

Ethernet 802.1ag MAC ping (LB) Yes Yes Yes


OAM
802.1ag MAC trace (LT) Yes Yes Yes

Association between 802.1ag Yes Yes Yes


and 802.3ah

Dying gasp Yes Yes Yes

Y.1731 unidirectional delay and Yes Yes Yes


jitter measurement (one-way
ETH-DM)

Y.1731 bidirectional delay and Yes Yes Yes


jitter measurement (two-way
ETH-DM)

802.3ah-based automated Yes Yes Yes


discovery

Remote loopback Yes Yes Yes

Link fault disposal Yes Yes Yes

Link fault detection Yes Yes Yes

Network - NTP Yes Yes Yes


synchroniza
tion Ethernet clock synchronization Yes Yes Yes

1588v2 Yes Yes Yes

Network EasyOperat EasyDeploy (client) Yes Yes Yes


manageme ion
nt and EasyDeploy (commander) Yes Yes Yes
monitoring
LLDP LLDP Yes Yes Yes

S12700 Series Agile Switches 14


Function and Feature Description S12704 S12708 S12712

LLDP-MED extended TLV Yes Yes Yes

RMON RMON Yes Yes Yes

RMON2 Yes Yes Yes

HTTP HTTP1.1 Yes Yes Yes

HTTPS Yes Yes Yes

Mirroring ERSPAN Yes Yes Yes

Layer 2 remote port mirroring Yes Yes Yes

Port mirroring Yes Yes Yes

- eMDI Yes Yes Yes

- NQA Yes Yes Yes

- NetStream Yes Yes Yes

- sFlow Yes Yes Yes

IP basic ICMP ICMP ping Yes Yes Yes


protocol
ICMP6 ping Yes Yes Yes

- Tracert Yes Yes Yes

IP services ARP ARP entries 384,000 384,000 384,000

ARP aging detection Yes Yes Yes

Intra-VLAN proxy ARP Yes Yes Yes

Inter-VLAN proxy ARP Yes Yes Yes

Dynamic ARP Yes Yes Yes

Multi-egress-interface ARP Yes Yes Yes

Routed proxy ARP Yes Yes Yes

Static ARP Yes Yes Yes

IPv4 VRF Yes Yes Yes


protocol
stack

IPv6 IPv6 address management Yes Yes Yes


protocol
stack VRF Yes Yes Yes

ND ND support Yes Yes Yes

ND entries 256,000 256,000 256,000

IP routing - Policy-based routing (PBR) Yes Yes Yes

Routing policy Yes Yes Yes

IPv4 routing IPv4 routes 3,072,000 3,072,000 3,072,000

BGP4 Yes Yes Yes

IPv4 static route Yes Yes Yes

S12700 Series Agile Switches 15


Function and Feature Description S12704 S12708 S12712

IS-IS Yes Yes Yes

MBGP Yes Yes Yes

OSPF Yes Yes Yes

RIPv1 Yes Yes Yes

RIPv2 Yes Yes Yes

IPv6 routing IPv6 routes 768K 768K 768K

BGP4+ Yes Yes Yes

IS-IS IPv6 Yes Yes Yes

OSPFv3 Yes Yes Yes

RIPng Yes Yes Yes

URPF URPF check in strict mode Yes Yes Yes

URPF check in loose mode Yes Yes Yes

Multicast Layer 2 IGMP v1/v2/v3 snooping Yes Yes Yes


multicast
MLD snooping v1 Yes Yes Yes

MLD snooping v2 Yes Yes Yes

VLAN-based IGMP snooping Yes Yes Yes


proxy

Replication of multicast data Yes Yes Yes


across VLANs

Layer 3 BFD for PIM Yes Yes Yes


multicast
IGMPv1 Yes Yes Yes

IGMPv2 Yes Yes Yes

IGMPv3 Yes Yes Yes

MLDv1 Yes Yes Yes

MLDv2 Yes Yes Yes

MSDP Yes Yes Yes

PIM SM V6 Yes Yes Yes

PIM-DM Yes Yes Yes

PIM-DM v6 Yes Yes Yes

PIM-SM Yes Yes Yes

RPF Yes Yes Yes

IPv4 multicast routes 128,000 128,000 128,000

IPv6 multicast routes 128,000 128,000 128,000

Multicast route policy Yes Yes Yes

IP security ARP VLAN-based ARP Miss packet Yes Yes Yes


security suppression

S12700 Series Agile Switches 16


Function and Feature Description S12704 S12708 S12712

VLAN-based ARP packet Yes Yes Yes


suppression

Global ARP packet suppression Yes Yes Yes

Source IP address-based ARP Yes Yes Yes


Miss packet suppression

Source IP address-based ARP Yes Yes Yes


packet suppression

Source MAC address-based ARP Yes Yes Yes


packet suppression

Interface-based ARP Miss packet Yes Yes Yes


suppression

Interface-based ARP packet Yes Yes Yes


suppression

Association between ARP and Yes Yes Yes


STP

ARP gateway attack inspection Yes Yes Yes

Defense against ARP address Yes Yes Yes


spoofing attacks: fixed-mac,
fixed-all, and send-ack

Sending gratuitous ARP packets Yes Yes Yes

Egress ARP Inspection (EAI) Yes Yes Yes

MFF Yes Yes Yes

ARP inspection against the Yes Yes Yes


dynamic binding tables

ARP inspection against the static Yes Yes Yes


binding tables

ICMP Global ICMP packet suppression Yes Yes Yes


attack
defense Interface-based ICMP packet Yes Yes Yes
suppression

IPSG IPv4 IPSG Yes Yes Yes

IPSG users 32000 32000 32000

IPv6 IPSG Yes Yes Yes

IPSGv6 users 32000 32000 32000

IPSG traffic check on a port Yes Yes Yes

IPSG traffic check in a VLAN Yes Yes Yes

Attack Defense against ICMP flood Yes Yes Yes


defense attacks

Local URPF Yes Yes Yes

Defense against TCP SYN flood Yes Yes Yes


attacks

S12700 Series Agile Switches 17


Function and Feature Description S12704 S12708 S12712

Defense against UDP flood Yes Yes Yes


attacks

Defense against packet fragment Yes Yes Yes


attacks

Defense against malformed Yes Yes Yes


packet attacks

Network BFD BFD for BGP Yes Yes Yes


reliability
BFD for IS-IS Yes Yes Yes

BFD for OSPF Yes Yes Yes

BFD for PIM Yes Yes Yes

BFD for VRRP Yes Yes Yes

BFD for static routes Yes Yes Yes

Single-hop BFD Yes Yes Yes

VRRP VRRP6 standard protocol Yes Yes Yes

VRRP standard protocol Yes Yes Yes

MPLS&VP L2VPN PWE3 Yes Yes Yes


N
VLL Yes Yes Yes

VPLS Yes Yes Yes

L3VPN MCE (VRF Lite) Yes Yes Yes

MPLS IPv4 VPN Yes Yes Yes

MPLS IPv6 VPN (6VPE) Yes Yes Yes

MPLS QoS Mapping from 802.1p priorities to Yes Yes Yes


EXP priorities in MPLS packets

Mapping from DSCP priorities to Yes Yes Yes


EXP priorities in MPLS packets

MPLS MPLS-TE protection group Yes Yes Yes


services
MPLS-TE tunnel establishment Yes Yes Yes

MPLS-TE tunnels 512 512 512

MPLS LDP Yes Yes Yes

Double MPLS labels Yes Yes Yes

IP tunneling - GRE tunneling Yes Yes Yes

GRE tunnels 512 512 512

IPv6 manual tunneling Yes Yes Yes

User AAA HWTACACS authentication Yes Yes Yes


access
RADIUS authentication Yes Yes Yes

HWTACACS authorization Yes Yes Yes

S12700 Series Agile Switches 18


Function and Feature Description S12704 S12708 S12712

HWTACACS accounting Yes Yes Yes

RADIUS accounting Yes Yes Yes

RADIUS authorization after Yes Yes Yes


successful authentication

Local authorization Yes Yes Yes

Local authentication Yes Yes Yes

DHCP Sub-interface functioning as a Yes Yes Yes


DHCP client

Option82 function Yes Yes Yes

Relay agent function of a VLANIF Yes Yes Yes


interface in a super VLAN

DHCP client function of a Yes Yes Yes


VLANIF interface

DHCP client function of the main Yes Yes Yes


interface for routing

Relay agent function of a VLANIF Yes Yes Yes


interface

VPLS DHCP snooping Yes Yes Yes

Dynamically assigning IP Yes Yes Yes


addresses to users

Relay agent function of the main Yes Yes Yes


interface for Ethernet routing

Dynamic DHCP packet rate- Yes Yes Yes


limiting

VLANIF interface address pool- Yes Yes Yes


based DHCP server function

VLAN-based DHCP snooping Yes Yes Yes

Global address pool-based Yes Yes Yes


DHCP server function

Global DHCP snooping Yes Yes Yes

Interface-based DHCP snooping Yes Yes Yes

DHCPv6 Relay agent function of a sub- Yes Yes Yes


interface

DHCPv6 relay Yes Yes Yes

VLAN-based DHCPv6 snooping Yes Yes Yes

Global DHCPv6 snooping Yes Yes Yes

Interface-based DHCPv6 Yes Yes Yes


snooping

Stateless DHCPv6 Yes Yes Yes

NAC Portal 2.01 authentication Yes Yes Yes

S12700 Series Agile Switches 19


Function and Feature Description S12704 S12708 S12712

Guest VLAN Yes Yes Yes

IEEE 802.1X Yes Yes Yes

Layer 3 Portal authentication of Yes Yes Yes


IPv4 users

Layer 2 Portal authentication of Yes Yes Yes


IPv4 users

MAC address authentication on a Yes Yes Yes


VLANIF interface

ETH-Trunk interface-based Yes Yes Yes


802.1X authentication

ETH-Trunk interface-based MAC Yes Yes Yes


address authentication

MAC address-based 802.1X Yes Yes Yes


authentication

Layer 2 Ethernet interface-based Yes Yes Yes


MAC authentication

Ethernet interface-based 802.1X Yes Yes Yes


authentication

Hybrid authentication Yes Yes Yes

Functioning as the control device Yes Yes Yes


in terms of policy association

ND Global ND snooping Yes Yes Yes


snooping
Interface-based ND snooping Yes Yes Yes

VLAN-based ND snooping Yes Yes Yes

- MACSec Yes Yes Yes


NOTE
By default, switches do not
support the MACsec function.
The MACsec function is
available only when a plug-in is
installed on the switch.

ACL Packet Number of rules per IPv4 ACL 4K 4K 4K


filtering at
Layer 2 to Number of rules per IPv6 ACL 2K 2K 2K
Layer 4
Layer 2 ACL Yes Yes Yes

Basic IPv4 ACL Yes Yes Yes

Basic IPv6 ACL Yes Yes Yes

User group ACL Yes Yes Yes

User-defined ACL Yes Yes Yes

OPS - Advanced IPv4 ACL Yes Yes Yes

QoS - Advanced IPv6 ACL Yes Yes Yes

S12700 Series Agile Switches 20


Function and Feature Description S12704 S12708 S12712

CAR OPS Yes Yes Yes

CPU- HQoS Yes Yes Yes


Defend

Traffic Matching the simple domains of Yes Yes Yes


classificatio packets
n
Traffic classification based on Yes Yes Yes
ACLs

Configuring traffic classification Yes Yes Yes


priorities

Traffic Modifying the packet VLANs Yes Yes Yes


behavior
Modifying the packet priorities Yes Yes Yes

Modifying the simple domains of Yes Yes Yes


packets

Traffic policing (CAR) Yes Yes Yes

Traffic filtering Yes Yes Yes

Traffic mirroring Yes Yes Yes

Traffic Traffic shaping on an egress Yes Yes Yes


shaping interface

Traffic shaping on queues on an Yes Yes Yes


interface

Congestion Tail drop Yes Yes Yes


avoidance
Weighted Random Early Yes Yes Yes
Detection (WRED) on interfaces

WRED on queues Yes Yes Yes

Congestion Priority Queuing (PQ) + Yes Yes Yes


manageme Weighted Deficit Round Robin
nt (WDRR)

PQ + Weighted Round Robin Yes Yes Yes


(WRR)

PQ Yes Yes Yes

WDRR Yes Yes Yes

WRR Yes Yes Yes

VXLAN BGP EVPN Dynamic creation of VXLAN Yes Yes Yes


tunnels through BGP EVPN

BGP EVPN neighbor 1,000 1,000 1,000


specifications

IPv4 IPv4 address configured for a Yes Yes Yes


gateway VBDIF interface

Distributed VXLAN IPv4 gateway Yes Yes Yes

Centralized VXLAN IPv4 gateway Yes Yes Yes

S12700 Series Agile Switches 21


Function and Feature Description S12704 S12708 S12712

IPv6 IPv6 address configured for a Yes Yes Yes


gateway VBDIF interface

Distributed VXLAN IPv6 gateway Yes Yes Yes

Centralized VXLAN IPv6 gateway Yes Yes Yes

- VXLAN Layer 2 gateway Yes Yes Yes

WLAN - AP management Yes Yes Yes

Number of managed APs  With MPUA:  With MPUA:  With MPUA:


6K 6K 6K
 With MPUD:  With MPUD:  With MPUD:
10K 10K 10K

WLAN QoS Yes Yes Yes

WLAN service management Yes Yes Yes

WLAN security Yes Yes Yes

Radio management Yes Yes Yes

WLAN user management Yes Yes Yes

Interoperabi - VLAN-based Spanning Tree Yes Yes Yes


lity (VBST)

Link-type Negotiation Protocol Yes Yes Yes


(LNP)

VLAN Central Management Yes Yes Yes


Protocol (VCMP)

Security - Firewall Yes Yes Yes


protection1
Network Address Translation Yes Yes Yes
(NAT)

SSL VPN Yes Yes Yes

IPSec Yes Yes Yes

Load balancing Analog Digital Yes Yes Yes


Conversion (ADC)

Intrusion Protection System (IPS) Yes Yes Yes

1: The S12700 supports the NGFW, which is the next-generation firewall card, and the IPS card. For more specification
information of IPS card, visit
http://support.huawei.com/enterprise/docinforeader.action?contentId=DOC1000047724&idPath=7919710|9856724|21430824|21
100539|21081581.

Hardware Specifications
The following table lists the hardware specifications of the S12700.

Hardware specifications of the S12700

Item S12704 S12708 S12712

Physical specifications Dimensions (H x 441.7 mm x 442 663.95 mm x 442 841.75 mm x 442

S12700 Series Agile Switches 22


Item S12704 S12708 S12712
W x D) mm x 489 mm mm x 489 mm mm x 489 mm

Chassis height 10 U 15 U 19 U

Weight (empty/full 24.5 kg/71.3 kg 42 kg/120 kg 64 kg/159 kg


configuration)

Number of MPU 2 2 2
slots

Number of SFU 2 4 4
slots

Number of LPU 4 8 12
slots

Direction of slots Horizontal Horizontal Horizontal

Environment parameters Operating altitude  -60 m to  -60 m to  -60 m to


+1800 m: 0°C +1800 m: 0°C +1800 m: 0°C
to 45°C to 45°C to 45°C
 1800 m to  1800 m to  1800 m to
4000 m: The 4000 m: The 4000 m: The
operating operating operating
temperature temperature temperature
decreases 1°C decreases 1°C decreases 1°C
for every 220 for every 220 for every 220
m increase in m increase in m increase in
altitude. altitude. altitude.
 More than  More than  More than
4000 m: 0°C 4000 m: 0°C 4000 m: 0°C
to 35°C to 35°C to 35°C

Storage -40°C to +70°C -40°C to +70°C -40°C to +70°C


temperature

Relative running 5% RH to 95% 5% RH to 95% 5% RH to 95%


humidity RH, RH, RH,
noncondensing noncondensing noncondensing

Relative storage 5% RH to 95% 5% RH to 95% 5% RH to 95%


humidity RH, RH, RH,
noncondensing noncondensing noncondensing

Noise (under ≤ 77.8 dB ≤ 72 dB ≤ 77.9 dB


normal
temperature)

IP rating IP20 IP20 IP20

System power Location of power modules Front view of a Front view of a Front view of a
supply chassis chassis chassis

Number of system power module slots 4 6 6

Hot swap of power modules Supported Supported Supported

Maximum power consumption 2550 W 5234 W 6790 W

800 W AC Surge protection  Common  Common  Common


specifications mode: ±4 kV mode: ±4 kV mode: ±4 kV
(power port)  Differential  Differential  Differential
mode: ±2 kV mode: ±2 kV mode: ±2 kV

S12700 Series Agile Switches 23


Item S12704 S12708 S12712

Input voltage and  Input: 90–290 N/A N/A


output power V
 Output: 800 W
(220 V), 400
W (110 V)

Backup mode 4 (M+N) N/A N/A

Maximum power 3200 W (220 V) N/A N/A


supply capability 1600 W (110 V)

3000 W AC Surge protection  Common  Common  Common


specifications mode: ±6 kV mode: ±6 kV mode: ±6 kV
(power port)  Differential  Differential  Differential
mode: ±6 kV mode: ±6 kV mode: ±6 kV

Input voltage and  Input: AC (90–  Input: AC (90–  Input: AC (90–


output power 290 V); output: 290 V); output: 290 V); output:
3000 W (220 3000 W (220 3000 W (220
V), 1500 W V), 1500 W V), 1500 W
(110 V) (110 V) (110 V)
 Input: DC  Input: DC  Input: DC
(190–290 (190–290 (190–290
VDC), rated VDC), rated VDC), rated
voltage: 240 V voltage: 240 voltage: 240
DC; output: VDC; output: VDC; output:
3000 W 3000 W 3000 W

Backup mode 4 (M+N) 6 (M+N) 6 (M+N)

Maximum power  8800 W (220  8800 W (220  8800 W (220


supply capability V) V) V)
 4400 W (110  4400 W (110  4400 W (110
V) V) V)

2200 W DC Surge protection  Common  Common  Common


specifications mode: ±4 kV mode: ±4 kV mode: ±4 kV
(power port)  Differential  Differential  Differential
mode: ±2 kV mode: ±2 kV mode: ±2 kV

Input voltage and  Input: DC (-40  Input: DC (-40  Input: DC (-40


output power V to -72 V) V to -72 V) V to -72 V)
 Output: 2200  Output: 2200  Output: 2200
W W W

Backup mode 4 (M+N) 6 (M+N) 6 (M+N)

Maximum power 8800 W 8800 W 8800 W


supply capability

System heat dissipation Heat dissipation Air extraction Air extraction Air extraction
mode

Airflow direction Left-to-rear Left-to-rear Left-to-rear

Intelligent fan Supported Supported Supported


speed control

Heat consumption Maximum power Maximum power Maximum power


data (BTU/h) consumption consumption consumption

S12700 Series Agile Switches 24


Item S12704 S12708 S12712
(W)*3.4121 (W)*3.4121 (W)*3.4121

COP (fan  Normal  Normal  Normal


modules) temperature: temperature: temperature:
COP=79.5 COP=154.8 COP=154.8
 High  High  High
temperature: temperature: temperature:
COP=9.1 COP=10.75 COP=10.75

Number of fan 2 4 5
trays

Hardware reliability MTBF (year)1 40.65 years 40.04 years 35.95 years

MTTR (minute)1 35 minutes 36 minutes 35 minutes

Availability1 0.999998837 0.9999984 0.9999981

MPU/SFU backup The MPU works in The MPU works in The MPU works in
hot backup mode, hot backup mode, hot backup mode,
and the SFU and the SFU and the SFU
works in 1+1 load works in 1+1 load works in 1+1 load
balancing mode. balancing mode. balancing mode.

Hot swap Supported by the Supported by the Supported by the


power module, fan power module, fan power module, fan
tray assembly, tray assembly, tray assembly,
CSS card, and CSS card, and CSS card, and
line card line card line card

CMU backup Active- standby Active- standby Active- standby


redundancy redundancy redundancy

Technical specifications Maximum FE port 192 384 576


density

Maximum GE port 192 384 576


density

Maximum 10GE 192 384 576


port density

Maximum 40GE 64 128 192


port density

Maximum 100GE 32 64 96
port density

1: The reliability parameter values are calculated based on the typical configuration of the device. The parameter values vary
according to the modules configured by the customer.

Networking and Applications


In an enterprise campus network
S12700 series switches are deployed on the core layer of an enterprise campus network. Native ACs provided by the S12700
enable customers to build wireless networks without additional AC hardware, reducing network construction costs. It is a core
switch that provides 4 Tbit/s AC capabilities, avoiding the performance bottleneck on independent ACs. The native AC
capabilities help customers migrate their wireless networks to 802.11ac or 802.11ax. The S12700 series realizes wired and

S12700 Series Agile Switches 25


wireless convergence and delivers consistent experience to wired and wireless users through uniform device, user, and service
management.

In a college campus network


S12700 series switches are deployed on the core layer of a college campus network. The unified user management function on
the S12700 reduces network construction costs by removing the need to purchase new BRAS hardware. Each S12700 switch
supports up to 65, 536 users, allowing a large number of concurrent access users. Its H-QoS feature implements fine granular
user and service management. The S12700 series realizes wired and wireless convergence and delivers consistent experience
to wired and wireless users through uniform device, user, and service management.

In a bearer network for video conferencing, desktop cloud, and video surveillance
applications
The Large buffer prevents packet loss upon traffic bursts, delivering high-quality video streams. The S12700 series supports up
to 1M MAC address entries and 3M FIB entries, which allow access from a large number of terminals and help evolution to IPv6
and the Internet of Things (IoT). Employing end-to-end hardware reliability technologies and iPCA technology, the S12700
series offers a highly reliable, high-quality, scalable video conferencing and surveillance solution.

On the core/aggregation layer of a MAN


S12700 series switches are used as core or aggregation switches on the Metropolitan Area Network (MAN) of a television
broadcasting or education network. The 3M FIB entries provided are sufficient for large-scale routing on the MAN. CSS2 switch
fabric hardware clustering technology, originating from clustering technology for high-end core routers, delivers carrier-class
reliability on the MAN. Additionally, the S12700 series supports comprehensive L2/L3 MPLS VPN features, providing a highly
reliable, secure, and scalable metropolitan bearer network solution.

In an enterprise data center


S12700 series switches are deployed on the core or aggregation layer of an enterprise data center network. The S12700 series
has high-density line cards, such as 48 x 10 GE, 16 x 40GE and 8 x 100GE cards, meeting the requirements for large data
throughput on data center core/aggregation nodes. Using CSS2 switch fabric hardware clustering technology, the S12700 series
provides up to 1.92 Tbit/s cluster bandwidth and shortens the inter-chassis forwarding latency to 4 μs. This technology helps
customers build a high performance, high reliability, and low latency data center network.

Safety and Regulatory Compliance


The following table lists the safety and regulatory compliance of the S12700.

Safety and regulatory compliance of the S12700 series

Certification Category Specification

Safety  IEC 60950-1


 EN 60950-1
 UL 60950-1
 CSA C22.2 No 60950-1
 AS/NZS 60950.1
 BS EN 60950-1
 CNS 14336-1

Electromagnetic  CISPR22 Class A


Compatibility (EMC)  CISPR24
 EN55022 Class A
 EN55024
 ETSI EN 300 386 Class A

S12700 Series Agile Switches 26


Certification Category Specification
 CFR 47 FCC Part 15 Class A
 ICES 003 Class A
 AS/NZS CISPR22 Class A
 VCCI Class A
 IEC61000-6-2
 IEC61000-6-4
 IEC61000-4-2
 ITU-T K 20
 ITU-T K 21
 ITU-T K 44
 CNS13438

Environment  RoHS
 REACH
 WEEE

Laser safety  IEC60825-1


 IEC60825-2
 EN60825-1
 EN60825-2

 EMC: electromagnetic compatibility


 CISPR: International Special Committee on Radio Interference
 EN: European Standard
 ETSI: European Telecommunications Standards Institute
 CFR: Code of Federal Regulations
 FCC: Federal Communication Commission
 IEC: International Electrotechnical Commission
 AS/NZS: Australian/New Zealand Standard
 VCCI: Voluntary Control Council for Interference
 UL: Underwriters Laboratories
 CSA: Canadian Standards Association
 IEEE: Institute of Electrical and Electronics Engineers
 RoHS: restriction of the use of certain hazardous substances
 REACH: Registration Evaluation Authorization and Restriction of Chemicals
 WEEE: Waste Electrical and Electronic Equipment

MIB and Standards Compliance


Supported MIBs
The following table lists the MIBs supported by the S12700 series.

MIBs supported by the S12700 series

Category Specification

Public MIB  BGP4-MIB


 BRIDGE-MIB

S12700 Series Agile Switches 27


Category Specification
 DISMAN-NSLOOKUP-MIB
 DISMAN-PING-MIB
 DISMAN-TRACEROUTE-MIB
 ENTITY-MIB
 EtherLike-MIB
 IF-MIB
 IP-FORWARD-MIB
 IPMCAST-MIB
 IPv6-ICMP-MIB
 IPv6-MIB
 IPv6-TCP-MIB
 IPv6-UDP-MIB
 ISIS-MIB
 LAG-MIB
 LLDP-EXT-DOT1-MIB
 LLDP-EXT-DOT3-MIB
 LLDP-MIB
 MGMD-STD-MIB
 MPLS-FTN-STD-MIB
 MPLS-L3VPN-STD-MIB
 MPLS-LDP-GENERIC-STD-MIB
 MPLS-LDP-STD-MIB
 MPLS-LSR-STD-MIB
 MPLS-TE-STD-MIB
 MSDP-MIB
 NOTIFICATION-LOG-MIB
 NQA-MIB
 OSPF-MIB
 OSPF-TRAP-MIB
 P-BRIDGE-MIB
 PIM-BSR-MIB
 PIM-STD-MIB
 Q-BRIDGE-MIB
 RFC1213-MIB
 RIPv2-MIB
 RMON2-MIB
 RMON-MIB
 SAVI-MIB
 SNMP-FRAMEWORK-MIB
 SNMP-MPD-MIB
 SNMP-NOTIFICATION-MIB
 SNMP-TARGET-MIB
 SNMP-USER-BASED-SM-MIB
 SNMPv2-MIB
 SNMP-VIEW-BASED-ACM-MIB

S12700 Series Agile Switches 28


Category Specification
 TCP-MIB
 UDP-MIB
 VRRP-MIB
 VRRPv3-MIB

Huawei-proprietary MIB  HUAWEI-AAA-MIB


 HUAWEI-ACL-MIB
 HUAWEI-ALARM-MIB
 HUAWEI-ALARM-RELIABILITY-MIB
 HUAWEI-BASE-TRAP-MIB
 HUAWEI-BFD-MIB
 HUAWEI-BGP-VPN-MIB
 HUAWEI-BRAS-RADIUS-MIB
 HUAWEI-BRAS-SRVCFG-EAP-MIB
 HUAWEI-BRAS-SRVCFG-STATICUSER-MIB
 HUAWEI-BULKSTAT-MIB
 HUAWEI-CBQOS-MIB
 HUAWEI-CCC-MIB
 HUAWEI-CONFIG-MAN-MIB
 HUAWEI-CLOCK-MIB
 HUAWEI-CPU-MIB
 HUAWEI-DAD-MIB
 HUAWEI-DC-TRAP-MIB
 HUAWEI-DATASYNC-MIB
 HUAWEI-DEVICE-MIB
 HUAWEI-DHCPR-MIB
 HUAWEI-DHCPS-MIB
 HUAWEI-DHCP-SNOOPING-MIB
 HUAWEI-DIE-MIB
 HUAWEI-DNS-MIB
 HUAWEI-DLDP-MIB
 HUAWEI-ERPS-MIB
 HUAWEI-ERRORDOWN-MIB
 HUAWEI-ENERGYMNGT-MIB
 HUAWEI-EASY-OPERATION-MIB
 HUAWEI-ENTITY-EXTENT-MIB
 HUAWEI-ENTITY-TRAP-MIB
 HUAWEI-ETHARP-MIB
 HUAWEI-ETHOAM-MIB
 HUAWEI-E-TRUNK-MIB
 HUAWEI-FLASH-MAN-MIB
 HUAWEI-FTP-MIB
 HUAWEI-FWD-RES-TRAP-MIB
 HUAWEI-GARP-APP-MIB
 HUAWEI-GTL-MIB

S12700 Series Agile Switches 29


Category Specification
 HUAWEI-GTSM-MIB
 HUAWEI-HGMP-MIB
 HUAWEI-HQOS-MIB
 HUAWEI-HWTACACS-MIB
 HUAWEI-IF-EXT-MIB
 HUAWEI-INFOCENTER-MIB
 HUAWEI-IPFPM-MIB
 HUAWEI-IPLPM-MIB
 HUAWEI-IPMCAST-MIB
 HUAWEI-IPPOOL-MIB
 HUAWEI-IPSESSION-MIB
 HUAWEI-IPV6-MIB
 HUAWEI-ISOLATE-MIB
 HUAWEI-KOMPELLA-MIB
 HUAWEI-L2IF-MIB
 HUAWEI-L2MAM-MIB
 HUAWEI-L2MULTICAST-MIB
 HUAWEI-L2VLAN-MIB
 HUAWEI-L2VPN-MIB
 HUAWEI-LDT-MIB
 HUAWEI-LSP-PING-TRACE-TRAP-MIB
 HUAWEI-LINE-MIB
 HUAWEI-LLDP-MIB
 HUAWEI-MAC-AUTHEN-MIB
 HUAWEI-MDNS-RELAY-MIB
 HUAWEI-MEMORY-MIB
 HUAWEI-MFF-MIB
 HUAWEI-MFLP-MIB
 HUAWEI-MGMD-STD-MIB
 HUAWEI-MPLS-EXTEND-MIB
 HUAWEI-MPLSLDP-MIB
 HUAWEI-MPLSLSR-EXT-MIB
 HUAWEI-MPLSOAM-MIB
 HUAWEI-MSDP-MIB
 HUAWEI-MSTP-MIB
 HUAWEI-MULTICAST-MIB
 HUAWEI-NETSTREAM-MIB
 HUAWEI-NTPV3-MIB
 HUAWEI-OSPFV2-MIB
 HUAWEI-OSPFV3-MIB
 HUAWEI-PERFORMANCE-MIB
 HUAWEI-PIM-BSR-MIB
 HUAWEI-PIM-STD-MIB
 HUAWEI-PERFMGMT-MIB
 HUAWEI-PORT-MIB

S12700 Series Agile Switches 30


Category Specification
 HUAWEI-PORTAL-MIB
 HUAWEI-PWE3-MIB
 HUAWEI-PWE3-TNL-MIB
 HUAWEI-QINQ-MIB
 HUAWEI-RIPv2-EXT-MIB
 HUAWEI-RM-EXT-MIB
 HUAWEI-RRPP-MIB
 HUAWEI-RSVPTE-MIB
 HUAWEI-SECURITY-MIB
 HUAWEI-SEP-MIB
 HUAWEI-SMARTLINK-MIB
 HUAWEI-SNMP-EXT-MIB
 HUAWEI-SSH-MIB
 HUAWEI-STACK-MIB
 HUAWEI-SWITCH-L2MAM-EXT-MIB
 HUAWEI-SWITCH-SRV-TRAP-MIB
 HUAWEI-SYS-MAN-MIB
 HUAWEI-TASK-MIB
 HUAWEI-TCP-MIB
 HUAWEI-TFTPC-MIB
 HUAWEI-TRNG-MIB
 HUAWEI-TUNNEL-MIB
 HUAWEI-TUNNEL-TE-MIB
 HUAWEI-UNIMNG-MIB
 HUAWEI-USC-MIB
 HUAWEI-VPLS-EXT-MIB
 HUAWEI-VPLS-TNL-MIB
 HUAWEI-VPN-DIAGNOSTICS-MIB
 HUAWEI-VRRP-EXT-MIB
 HUAWEI-WLAN-DEVICE-MIB
 HUAWEI-WLAN-QOS-MIBB
 HUAWEI-WLAN-RADIO-MIB
 HUAWEI-WLAN-SECURITY-MIB
 HUAWEI-WLAN-SERVICE-MIB
 HUAWEI-WLAN-SYS-MIB
 HUAWEI-WLAN-UPDATE-MIB
 HUAWEI-WLAN-WIDS-MIB
 HUAWEI-XQOS-MIB

For more information about MIBs supported by the S12700 series, visit
https://support.huawei.com/enterprise/en/switches/s12700-pid-20985028?category=reference-guides&subcategory=mib-
reference

Standard Compliance
The following table lists the standards that the S12700 complies with.

S12700 Series Agile Switches 31


Standard compliance list of the S12700 series

Standard Standard or Protocol


Organization

IETF  RFC 768 User Datagram Protocol (UDP)


 RFC 792 Internet Control Message Protocol (ICMP)
 RFC 793 Transmission Control Protocol (TCP)
 RFC 826 Ethernet Address Resolution Protocol (ARP)
 RFC 854 Telnet Protocol Specification
 RFC 951 Bootstrap Protocol (BOOTP)
 RFC 959 File Transfer Protocol (FTP)
 RFC 1058 Routing Information Protocol (RIP)
 RFC 1112 Host extensions for IP multicasting
 RFC 1157 A Simple Network Management Protocol (SNMP)
 RFC 1256 ICMP Router Discovery
 RFC 1305 Network Time Protocol Version 3 (NTP)
 RFC 1349 Internet Protocol (IP)
 RFC 1493 Definitions of Managed Objects for Bridges
 RFC 1542 Clarifications and Extensions for the Bootstrap Protocol
 RFC 1643 Ethernet Interface MIB
 RFC 1757 Remote Network Monitoring (RMON)
 RFC 1901 Introduction to Community-based SNMPv2
 RFC 1902-1907 SNMP v2
 RFC 1981 Path MTU Discovery for IP version 6
 RFC 2131 Dynamic Host Configuration Protocol (DHCP)
 RFC 2328 OSPF Version 2
 RFC 2453 RIP Version 2
 RFC 2460 Internet Protocol, Version 6 Specification (IPv6)
 RFC 2461 Neighbor Discovery for IP Version 6 (IPv6)
 RFC 2462 IPv6 Stateless Address Auto configuration
 RFC 2463 Internet Control Message Protocol for IPv6 (ICMPv6)
 RFC 2474 Differentiated Services Field (DS Field)
 RFC 2740 OSPF for IPv6 (OSPFv3)
 RFC 2863 The Interfaces Group MIB
 RFC 2597 Assured Forwarding PHB Group
 RFC 2598 An Expedited Forwarding PHB
 RFC 2571 SNMP Management Frameworks
 RFC 2865 Remote Authentication Dial In User Service (RADIUS)
 RFC 3046 DHCP Option82
 RFC 3376 Internet Group Management Protocol, Version 3 (IGMPv3)
 RFC 3513 IP Version 6 Addressing Architecture
 RFC 3579 RADIUS Support For EAP
 RFC 4271 A Border Gateway Protocol 4 (BGP-4)
 RFC 4760 Multiprotocol Extensions for BGP-4
 draft-grant-tacacs-02 TACACS+

IEEE  IEEE 802.1D Media Access Control (MAC) Bridges

S12700 Series Agile Switches 32


Standard Standard or Protocol
Organization
 IEEE 802.1p Virtual Bridged Local Area Networks
 IEEE 802.1Q Virtual Bridged Local Area Networks
 IEEE 802.1ad Provider Bridges
 IEEE 802.2 Logical Link Control
 IEEE Std 802.3 CSMA/CD
 IEEE Std 802.3ab 1000BASE-T specification
 IEEE Std 802.3ad Aggregation of Multiple Link Segments
 IEEE Std 802.3ae 10GE WEN/LAN Standard
 IEEE Std 802.3x Full Duplex and flow control
 IEEE Std 802.3z Gigabit Ethernet Standard
 IEEE802.1ax/IEEE802.3ad Link Aggregation
 IEEE 802.3ah Ethernet in the First Mile.
 IEEE 802.1ag Connectivity Fault Management
 IEEE 802.1ab Link Layer Discovery Protocol
 IEEE 802.1D Spanning Tree Protocol
 IEEE 802.1w Rapid Spanning Tree Protocol
 IEEE 802.1sMultiple Spanning Tree Protocol
 IEEE802.1x Port based network access control protocol

ITU  ITU SG13 Y.17ethoam


 ITU SG13 QoS control Ethernet-Based IP Access
 ITU-T Y.1730 ETH OAM performance monitor
 ITU-T Y.1731 ETH OAM performance monitor
 ITU-T Y.1710 Requirements for OAM functionality for MPLS networks
 ITU-T Y.1711 Operation and maintenance mechanism for MPLS networks
 ITU-T Y.1720 Protection switching for MPLS networks

ISO  ISO 10589IS-IS Routing Protocol

MEF  MEF 2 Requirements and Framework for Ethernet Service Protection


 MEF 9 Abstract Test Suite for Ethernet Services at the UNI
 MEF 10.2 Ethernet Services Attributes Phase 2
 MEF 11 UNI Requirements and Framework
 MEF 13 UNI Type 1 Implementation Agreement
 MEF 15 Requirements for Management of Metro Ethernet Phase 1 Network Elements
 MEF 17 Service OAM Framework and Requirements
 MEF 20 UNI Type 2 Implementation Agreement
 MEF 23 Class of Service Phase 1 Implementation Agreement
 Xmodem XMODEM/YMODEM Protocol Reference

Ordering Information

Ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for
reference only. To obtain the latest ordering information, contact Huawei switch distributors or Huawei local office.

S12700 Series Agile Switches 33


S12700 basic configuration

LE2BN66ED000 N66E DC assembly rack (eight 60A outputs, maximum 2, 200W per output, 600 x 600 x 2, 200
mm)

LE2BN66EA000 N66E AC assembly rack (four 16A outputs, maximum 2, 500W per output, 600 x 600 x 2, 200 mm)

ET1BS12704S0 S12704 Assembly Chassis

ET1BS12708S0 S12708 Assembly Chassis

ET1BS12712S0 S12712 Assembly Chassis

ET1MFBX00000 Wide Voltage 129 Fan Box

EH1M00FBX000 Wide Voltage 74 Fan Box

Main Control Unit Supported


Version

ET1D2MPUDC00 S12704/S12708/S12712 Main Processing Unit D

Monitoring Board

EH1D200CMU00 Centralized Monitoring Unit

Switch Fabric Unit

ET1D2SFUA000 S12700 Switch Fabric Unit A

ET1D2SFUB000 S12700 Switch Fabric Unit B

ET1D2SFUD000 S12708/S12712 Switch Fabric Unit D

100M/1000M Ethernet electrical interface cards Supported


Version

LST7G48TX5S0 48-port 10/100/1000BASE-T interface card (X5S, M, RJ45) V200R019C00 and


later versions

LST7G48TX5E0 48-port 10/100/1000BASE-T interface card (X5E, M, RJ45) V200R019C00 and


later versions

100M/1000M Ethernet optical interface cards Supported


Version

LST7G48SX6S0 48-port GE SFP interface card (X6S,SFP) V200R019C00 and


later versions

LST7G48SX6E0 48-port GE SFP interface card (X6E,SFP) V200R019C00 and


later versions

S12700 Series Agile Switches 34


10 GE optical interface cards Supported
Version

LST7X48SX6S1 48-port 10GE SFP+ interface card (X6S,SFP+) V200R019C00 and


later versions

LST7X48SX6E1 48-port 10GE SFP+ interface card (X6E,SFP+) V200R019C00 and


later versions

LST7X24BX6S0 24-port 10GE SFP+ interface and 24-port GE SFP interface card V200R019C00 and
(X6S,SFP+) later versions

LST7X24BX6E0 24-port 10GE SFP+ interface and 24-port GE SFP interface card V200R019C00 and
(X6E,SFP+) later versions

40GE/100GE optical interface cards Supported


Version

LST7C02BX6E0 2-port 100GE QSFP28 interface and 4-port 40GE QSFP28 interface V200R020C00 and
card (X6E,QSFP28) later versions

100GE optical interface cards Supported


Version

LST7C06HX6S1 6-port 100GE QSFP28 interface card (X6S,QSFP28) V200R019C00 and


later versions

LST7C06HX6E1 6-port 100GE QSFP28 interface card (X6E,QSFP28) V200R019C00 and


later versions

Service subcards

EH1D2VS08000 8-port 10G cluster switching system service unit (SFP+)

ET1D2VQ06000 6-Port 40GE Cluster Switching System Service Unit (QSFP+)

Power modules Supported


Version

PAC3KS54-NE 3000W AC power module (Black) V200R020C10 and


later versions

PAC3KS54-CE 3000W AC power module (Black) V200R019C00 and


later versions

PAC3KS54-CB 3000W AC Power Module(Black)

W2PSD2200 2200W DC power module V200R019C00 and


later versions

PDC-2200WF 2200W DC power module

W2PSA0800 800W AC Power Module (black)

S12700 Series Agile Switches 35


Software

ET1SM2D12700 S12700 Basic SW,V200R013C00

ET1SM2J12700 S12700 Basic SW,V200R019C00

EST7R20C00SW S12700 Basic SW,V200R020C00

EST7R20C10SW S12700 Basic SW,V200R020C10

License

ET1SMPLS0000 MPLS Function License

ET1SNQA00000 NQA Function License

ET1SIPV60000 IPV6 Function License

ET1SSVFF0000 SVF Function License (applicable only to the S12700 series)

ET1SVXLAN000 VXLAN enhanced function license(used in S12700 series)

ET1SFIB128K0 X-series LPU FIB Resource License-128K

ET1SFIB512K0 X-series LPU FIB Resource License-512K

ET1SWL512AP0 WLAN Access Controller AP Resource License-512AP (with the X-series LPU used)

ET1SWL128AP0 WLAN Access Controller AP Resource License-128AP (with the X-series LPU used)

ET1SWL64AP00 WLAN Access Controller AP Resource License-64AP (with the X-series LPU used)

ET1SWL16AP00 WLAN Access Controller AP Resource License-16AP (with the X-series LPU used)

N1-S127-F-Lic N1-CloudCampus,Foundation,S127 Series,Per Device

N1-S127-F-SnS1Y N1-CloudCampus,Foundation,S127 Series,SnS,Per Device,1Year

N1-S127-A-Lic N1-CloudCampus,Advanced,S127 Series,Per Device

N1-S127-A-SnS1Y N1-CloudCampus,Advanced,S127 Series,SnS,Per Device,1Year

N1-S127-FToA-Lic N1-Upgrade-Foundation to Advanced,S127 Series,Per Device

N1-S127-FToA- N1-Upgrade-Foundation to Advanced,S127 Series,SnS,Per Device,1Year


SnS1Y

N1-AC1.0-AM-15-Lic N1-CloudCampus,Access Management-AC1.0,15 Terminals

N1-AC1.0-AM-15- N1-CloudCampus,Access Management-AC1.0,15 Terminals,SnS,1Year


SnS1Y

CI-X7MSwitch-U CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, Per Device

CI-X7MSwitch-U- CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, SnS, Per Device, 1


SnS1Y Year

Documentation

ET1IV2RDC0C0 S12700 Series Agile Switches V200R013C00 Product Documentation

ET1IV2RJC0E0 S12700 Series Agile Switches V200R019C00 Product Documentation

S12700 Series Agile Switches 36


More Information
For more information about Huawei Campus Switches, visit http://e.huawei.com or contact us in the following ways:

 Global service hotline: http://e.huawei.com/en/service-hotline


 Logging in to the Huawei Enterprise technical support website: http://support.huawei.com/enterprise/
 Sending an email to the customer service mailbox: support_e@huawei.com

Copyright © Huawei Technologies Co., Ltd. 2020. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice

The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and
Huawei Technologies Co., Ltd.
recommendations in this document are provided "AS IS" without warranties, guarantees or representations of
any kind, either express or implied. Address:Huawei Industrial Base Bantian,
Longgang Shenzhen 518129 People's
The information in this document is subject to change without notice. Every effort has been made in the
Republic of China
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied. Website:e.huawei.com

S12700 Series Agile Switches 37

You might also like