■ SPECIFICATION & CHARACTERIRTICS ■ TIMING CHARTS ● H3CR-A8E

ANV ELECTRIC DIMENSIONS 48H x 48W x 81.6D(mm)


● H3CR-A Mode A
SOURCE(2-7)
t Rt t Rt t-a

Mode A t t

H3CR
SOURCE(2-10) NC(1-4)

START(2-6) NO(1-3)
RESET TIME 0.1sec max.
RESET(2-7) NC(8-5)

MULTI-FUNCTION TIMER
NC (1-4) (11-8) NC(8-6)

REPEAT ERROR 0.3% max. NO(1-3) (11-9) PW LAMP

A PW LAMP t t t-a Rt t t t t-a


Mode B2
C
MANUAL SETTING ERROR 5% max. t t t-a t t t SOURCE(2-7)
C Mode B
U SOURCE(2-10) NC(1-4)
R
START(2-6) NO(1-3)
A VOLTAGE ERROR 0.5% max.
■ FRONT PART C RESET(2-7) NC(8-5)
Y
NC (1-4) (11-8) NC(8-6)
POWER A
1 4 TEMP. ERROR 2% max.
OUT
NO(1-3) (11-9) PW LAMP
2 15 PW LAMP
MODE Mode E t Rt t Rt t-a
10 20
UP 6 t-a
L MECHANICAL 5 x 10 times Mode B2 t t t t t SOURCE(2-7)
5 25 I SOURCE(2-10) NC(1-4)
5
F
START(2-6)
E ELECTRICAL 5
10 times
NO(1-3)
3 0 30
RESET(2-7) NC(8-5)
sec NC (1-4) (11-8) NC(8-6)
6 INSULATION
100 M . Min(at 500VDC) NO(1-3) (11-9)
RESISTANCE PW LAMP
H3CR
PW LAMP
Mode J t Rt t-a Rt t
Number Function Number Function 2000VAC, 50/60Hz for 1 min between current-carring metal parts t-a t-a t-a
Mode C t t t t
and exposed non-current-carring metal parts SOURCE(2-7)
1 Power indicator 4 * Operating mode selector DIELECTRIC
2000VAC, 50/60Hz for 1 min between control output terminal and SOURCE(2-10)
NC(1-4)
2 Output indicator 5 Setting dial STRENGTH operating circuit
* H3CR-A : A、B、B2、C、D、E START(2-6)
NO(1-3)
Rated time selector Time unit selector H3CR-A-300 : G、J 1000VAC, 50/60Hz for 1 min between not located next to each other
3 ( 1 . 2, 3, 12, 30) 6 ( sec,min,hrs,10h) RESET(2-7)
H3CR-A8 : A、B2、E、J NC(8-5)
NC (1-4) (11-8) 1S±0.5S 1S±0.5S
NC(8-6)
AMBIENT TEMPERATURE -10℃~+55℃
■ DIMENSIONS 15 0.7
NO(1-3) (11-9)
PW LAMP
6 PW LAMP
● H3CR-A - 300
t t-a t-a t t-a
AMBIENT HUMIDITY 45~85%RH Mode D t t t-a t t-a t
Mode G
SOURCE(2-10) SOURCE(2-10)
UP

39dia 44.8 DEGREE OF START(2-6) START(2-6)


IP40(Panel Surface)
48

PROTECTION RESET(2-7) RESET(2-7)


NC (1-4) (11-8) NC(1-4) (11-8)
WEIGHT Approx. 90g NO(1-3) (11-9)
52.3 NO(1-3) (11-9)
66.6 PW LAMP
48 50
PW LAMP

■ CONNECTION DIAGRAMS Mode E t t t t-a t-a t


Mode J
t t-a t-a t

SOURCE(2-10) SOURCE(2-10)
+0.5
H3CR-A8 H3CR-A
45 START(2-6) START(2-6)
-0
RESET(2-7) RESET(2-7)
50

NC (1-4) (11-8) NC(1-4) (11-8)


45 +0.5
-0
5 6 7
NO(1-3) (11-9) NO(1-3) (11-9) 1S±0.6S 1S±0.6S
4 5
4 8
3 6 PW LAMP PW LAMP
(Unit : mm) 3 9
RESET
START
GATE

2 7 2 10
1 11 ● H3CR-A8 ● GATE USE METHOD
1 8
t1 t2
■ ORDERING INFORMATION Mode A t Rt t Rt t-a EXAMPLE:
Mode A SOURCE
SOURCE(2-7)
TIME RATED OUTPUT OPERATING PIN START
MODEL
RANGE VOLTAGE METHOD MODE TYPE
NC(8-5) (1-4)
SOURCE GATE
A:Signal ON delay SOURCE
H3CR-A 300hrs 100~240VAC TIME LIMIT 2C B:Flicker OFF start NO (8-6) (1-3)
RESET

B2:Flicker ON start H3CR-A8S H3CR-AS Relay Output


C:Signal ON-OFF delay Setting time: t 1 + t 2
PW LAMP
TIME LIMIT 1C D:Signal OFF delay
H3CR-AS 300hrs 100~240VAC 11 Pin
( TRANSISTOR ) E:Signal ON interval t t t-a Rt t t t t-a
■ NOTICE
Mode B2
SOURCE(2-7)
G:Signal ON-OFF delay 5 6 7
H3CR-A-300 300hrs 100~240VAC TIME LIMIT 2C
J:One-shot output 4 5 4 8 1.Make sure that the load power supply is within the rating
RESET
START
GATE

3 6 3 9 NC(8-5) (1-4)
2.Never disassemble,modify or repair
2 2 10
7 1 11
H3CR-A8 300hrs 24~240VDC/AC TIME LIMIT 2C 1 8 NO (8-6) (1-3) 3.Make sure the proper product is specified for the
application
A:Signal ON delay PW LAMP
TIME LIMIT 1C B2:Flicker ON start 4.Wire terminals with correct polarity
H3CR-A8E 300hrs 24~240VDC/AC 8 Pin
INSTANTANEOUS 1C E:Signal ON interva t Rt t Rt t-a
Mode E 5.Locate the timer,input devices and input signal wiring
J:One-shot output SOURCE
SOURCE SOURCE(2-7) as far as possible from noise sources and conductors
TIME LIMIT 1C
H3CR-A8S 300hrs 24~240VDC/AC ( TRANSISTOR) H3CR-A8E H3CR-A-300 NC(8-5) (1-4) carrying high voltage

■ MAIN PRODUCTS
NO (8-6) (1-3)
■ TIME RANGE
TIME UNIT 5 6 7 PW LAMP
FULL sec min hrs 10h 4 5 4 8 TIMER THERMOCOUPLE
SCALE SETTING 3 6 3 9 Mode J t Rt t-a Rt t
RESET
START
GATE

2 7
2
1 11
10 TEMPERATURE CONTROLLER COUNTER
1.2 0.05~1.2 0.12~1.2 1.2~12 SOURCE(2-7)
1 8
CONTROLLER/INDICATOR UNITS FLOATLESS RELAY
3 0.3~3 3~30 NC(8-5) (1-4)
300hrs SOLID STATE RELAY LIMIT SWITCH
1S±0.5S 1S±0.5S
12 1.2~12 12~120 NO (8-6) (1-3)
PROXIMITY SWITCH DIGITAL PID CONTROLLER
SOURCE SOURCE
30 3~30 30~300 PW LAMP POWER RELAY SOCKETS & ACCESSORIES