EZ002_00_0601GB
LubricationPumpQLS401
EZ002_00_0601GB
Tableofcontent
1.5 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . — 4
2 Manipulation . . . . . . . . . . . . . . . . . . 5
2.1 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Troubleshooting . . . . . . . . . . . . . . . 8
LubricationPumpQLS401
1 Technical Description
1.1 Automatic lubrication The serial manual central lubrication facilitates the lubrication of a
function construction group from one single point. Thereby the lubricant is
delivered to the respective lube points by a central lubricant dis
tribution block. The lubricant supply is carried out manually (seri
ally) via a manual pump or a lubrication pump (optional) that pumps
the lubricant to the central distribution block .
4
5
EZ002_02_06501GB 0
1 Filling nipple
2 Distributor nipple for emergency lubrication
3 Ventilation borehole
4 Fix paddle
5 Stirring paddle
EZ002_02_06501GB 1
LubricationPumpQLS401
4 2
3
EZ002_02_06501GB 1
1 Filling nipple
2 Distributor nipple for emergency lubrication
3 Proximity switch
4 Control pin
5 Lubricant distribution block (SSV)
EZ002_02_06501GB 2
1 Proximity switch
2 Plastified keypad
3 Control unit
4 Pump unit
5 Lubricant distribution block (SSV)
EZ002_02_06501GB
2
LubricationPumpQLS401
EZ002_02_06501GB 3
EZ002_02_06501GB 3
LubricationPumpQLS401
1.5 Programming Various settings in the central lubrication installation are set ex
works. These settings regulate the lubrication intervals and the lu
brication time. Have the default settings modified by the After Sales
Department if either the lubrication intervals or the lubrication times
do not meet your needs.
Interval time The interval time is the time between two lubrication processes. The
interaval time only runs down when the ignition is switched on. The
interval times are retained during interruptions. The new times are
added on restarting.
Operation time Operation time is the time in which the central lubrication pump is in
operation during a lubrication process. The operation time is con
trolled by the system via the piston detectors and limited by the
monitoring time.
Monitoring time The monitoring time starts with switching on the central lubrication
pump . Monitoring time is the time in which the piston detector has
to confirm with a checkback signal.The monitoring time is set at 25
min by the manufacturer.
Note
If another interval is necessary because of the local conditions, it
can be changed. Please contact the after sales service of the al
liance Sika−Putzmeister.
Note
An additional lubrication can also be carried out up to 3 times with
out the system being connected. The automatic lubrication cycle is
interrupted after the third notice grease tank empty".
EZ002_02_06501GB
4
LubricationPumpQLS401
2 Manipulation
2.1 Display
EZ002_07_0601GB 4
1 Display
2 Key for initiating additional lubrication
3 Key for acknowledging a malfunction
− indication of the adjusted pausing time and the pausing time which is left
Switch on
After switching on the pump (on), the segment on the right of the
display lights up (pausing time is counting).
Lubrication time
EZ002_07_0601GB 5
LubricationPumpQLS401
Malfunction
" Exceeding the monitoring time of 25 min (fixed time in the VDC
model) after triggering an additional lubrication or
Note
If there is a malfunction <Er>, the QLS 401 no longer switches on
automatically.
" For this, keep the button pressed for more than 2 seconds.
EZ002_07_0601GB
6
LubricationPumpQLS401
4 2
3
EZ002_07_0601GB 5
1 Filling nipple
2 Distributor nipple for emergency lubrication
3 Proximity switch
4 Control pin
5 Lubricant distribution block (SSV)
" Fill tank via the filling nipple 1 up to the marking MAX.
Note
When working with the central lubrication installation, keep it clean!
Dirt in the system leads to malfunctions.
The grease has to be free from contaminations and may not change
its consistency in the course of time.
Danger
For cleaning the installation, use benzine or paraffin. Do NOT use
Tri, Per or similar solvents and polar, organic ones like alcohol, meth
anol, acetone or the like.
EZ002_07_0601GB 7
LubricationPumpQLS401
3 Troubleshooting
Cause Remedy
Power supply is interrupted. Check the power supply to the pump/fuses. If necessary,
Green decimal point On/h on eliminate the fault or replace the fuses.
display is not lit. Check the feedline from the fuses to the plug of the pump and
then to the printed circuit board.
Power supply from printed Trigger an additional lubrication. Check power supply from the
circuit board to the motor printed circuit board to the motor. If necessary, replace motor.
interrupted. Defective electric
motor.
Key of keypad is defective. *EP* sign on the display lights up. Replace housing with plastified
keypad.
Cause Remedy
Empty tank. Warning sign *ER* Fill the tank with clean grease. Let the pump run (see page 18,
is flashing. paragraph Additional lubrication"), until the lubricant comes out
Pump does not deliver of all the lube points.
lubricant and *ER* sign on the
keypad is flashing.
Trapped air in the lubricant. Trigger several additional lubrications. The lubricant has to come
out without any bubbles.
EZ002_08_0601GB
8
LubricationPumpQLS401
Cause Remedy
Suction hole of pump element Dismount pump element and check suction hole for foreign
is blocked. substances. If there are any, remove them.
Note
Depending on the ambient temperature and/or type of lubricant, the
pump element needs more operation time to reach the maximum de
livery rate. Therefore trigger several additional lubrications.
Cause Remedy
Distance between control pin Check the distance and, if necessary, adjust them.
and proximity switch is more G Max. distance between control pin and switching surface of the
than 0.5 mm. initiator = 0.5 mm.
EZ002_08_0601GB 9
LubricationPumpQLS401
Cause Remedy
EZ002_08_0601GB
10