CHECKLIST FOR HEAT EXCHANGER VISUAL INSPECTION

Owner/ User
PT Medco E&P Malaka/ PT Medco E&P Malaka Tag No/ Serial No 39-HBG-201 B / D1610-12B
Company
Location CPP Alur Siwah Blok-A, Aceh Timur Type/ Size Horizontal / 939,8 mm (ID) x 6317 mm (LoA)

Description LOW TEMPERATURE SEPARATOR Year Built/ Used 2017 / 2017


Shell Tube Design Shell Tube
Design Pressure
Temperature
(kg/cm2) 14,76 11,95 160 160
(oC) Previous
M119A.DH.52.17
Operating Certificate No.
Operating
Temperature 215
Pressure (psig)
(oF)
 
Conditions Remarks
No. Descriptions
YES NO S NS
1 Name Plate √ √
  2 Level Glass √ √
  3 Pressure Indicator √ √ *monitored from CCR
  4 Temperature Indicator √ √ 1 Unit, Operating Temperature : 215 ⁰F
  5 Ladder √ √
 
  6 Foundation √ √
  7 Drainage √ √
  8 Grounding √ √
  9 Lightning Arrestor √
 
10 Painting √ *cannot be observed due to insulated
 
  11 Interface Level Indicating
√ √
  Control
  12 Insulation √ √
  13 Bolt & Nut √ √
 