Professional Documents
Culture Documents
Write note on Gross and Systematic errors. How these errors can be June 2009
5 6
controlled?
Component manufacturer constructs certain resistance to be between
6
1.33K and 1.47K. What tolerance should be stated? If the resistance June 2009
6 7
values are specified at 25oC, calculate maximum resistance at 75oC if June 2016
temperature coefficient is +500ppm/oC.
Component manufacturer constructs certain resistance to be between
1.14K and 1.26K. and classifies them as 1.2KΩ resistors. What
tolerance should be stated if the resistance values are specified at 25 o 6 Jan 2018
C and the resistors have the temperature co-efficient of +550ppm/oc,
calculate the maximum resistance of one of these components at 75oC.
7 Explain the working of AC voltmeter using Full wave bridge rectifier. 8 June 2009
A true value of voltage across a resistor is 50V, the instrument reads
8 4 Dec 2010
49V. Calculate the absolute error and percentage error
Explain with a circuit diagram, how a basic D’ Arsonval movement
can be converted into a DC voltmeter. Calculate a multiplier Dec 2010
9 10
resistance required to measure voltage range of (0-25)V, when RM=50
ohms, Ig=50µA.
Discuss briefly the different types of static errors of a measuring
10 6 Jan 2012
instrument
Convert the basic D’Arsonval movement into a DC Voltmeter and
11. 4 Jan 2017
derive the resistance equation
The expected value of voltage across a resistor is 80V.However the
12 measurement gives a value of 79V.Calculate i)absolute error ii)% of 4 Jan 2017
error iii)Relative accuracy iv)% of accuracy.
a)State different types of thermocouples used for RF current
measurement and explain each one of them in brief 8 Jan 2017
13 5 July 2017
b)Define principle operation of thermocouple, and also explain types
of thermocouple
a)Explain with diagram the operation of dc differential voltmeter 8 Jan 2017
14
b)Explain differential voltmeter with circuit 4 July 2017
Design a multi-range ammeter with range of 0-1A,5A and 10A
employing individual shunt in each D’Arsonal movement with an 5 July 2017
15
internal resistance of 500Ω and a full scale deflection of 10mA is 6 Jan 2018
available
16 What is loading effect 2 July 2017
Calculate series connected multiplier resistance with a D’Arsonal
movement with an internal resistance of 100Ω and a full scale
17 4 July 2017
deflection of 10mA into a multi-range dc voltmeter with ranges from
0-5V,0-50V and 0-100V.
Calculate the value of multiplier resistance on the 50V range of DC
18 voltmeter that uses 500µA meter movement with internal resistance of 4 Jan 2018
1KΩ
Two different voltmeters are used to measure the voltage across R b in
the circuit of fig(a).The meters are as follows.
Meter 1:S=1kΩ/V,R m=0.2K.Rang 10V
Meter 2:S=20KΩ/V,Rm=1.5K,range 10V
Calculate
19 6 Jan 2018
i)voltage across Rb without any meter across it.
ii)Voltage across Rb when meter 1 is used.
iii)Voltage across Rb when meter 2 is used.
iv)error in the voltmeters.
Fig.(a)
Module – 2
Q. No. Question Marks Year
4 Dec 2007
Discuss the advantage of digital voltmeter over an analog voltmeter.
1 3 Dec 2010
4 Jan 2013
2 Explain basic principle of digital multimeter with neat diagram. 7 June 2013
6 Jan 2014
6 Dec 2007
3 Determine the resolution of 3 ½ digital display on 1v & 10 range.
10 June 2008
8 Jan 2014
4 Explain the principle of successive approximation type DVM.
8 July 2017
8 Jan 2018
Dec 2007
10
June 2008
7
Dec 2010
10
Dec 2011
Explain the working of digital frequency meter with the help of block 7
5 Jan 2013
diagram 8
June 2013
8
Dec 2015
8
Jan 2017
6
Jan 2018
With the help of block diagram explain the working of Dual slope 10 June 2009
6
integrating type DVM. 8 Jan 2017
10 Dec 2010
Explain the working of ramp type DVM with the help of block
7 10 Dec 2011
diagram
8 Dec 2015
8 Discuss briefly the general specification of digital voltmeter 5 Jan 2013
An integrator contains 100KΩ and 1µF capacitor, if the voltage
9 applied to the integrator input is 1V, What voltage will be present at 2 Jan 2017
the output of the integrator after 1s?
10 Explain the principle operation of staircase ramp 6 July 2017
11 Explain with block diagram explain digital phase meter operation 6 Jan 2017