SL NO DESIGN LOADS

1 SELF WEIGHT OF STRUCTURE

2 LIVE LOAD ON THE ROOF SLAB

3 HYDRO-MECHANICAL LOAD ON ROOF SLAB

4 HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED

5 HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN

6 UPLIFT PRESSURE

7 EARTH PRESSURE

8 HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED

9 HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN

10 DYNAMIC INCREMENT OF EARTH PRESSURE

11 SEISMIC INERTIA IN ( +1.0 X , + 0.3Y, + 0.3 Z) DIRECTION

12 SEISMIC INERTIA IN ( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION

13 SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, + 1.0 Z) DIRECTION

14 SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION


SL NO LOAD COMBINATIONS LOADING DETAILS
SELF WEIGHT OF STRUCTURE

CONSTRUCTION COMPLETE LIVE LOAD ON THE ROOF SLAB


1
CONDITION & EMPTY RESERVOIR HYDRO-MECHANICAL LOAD ON ROOF SLAB
EARTH PRESSURE
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
CONSTRUCTION COMPLETE
CONDITION & EMPTY RESERVOIR HYDRO-MECHANICAL LOAD ON ROOF SLAB
2
WITH EQ IN ( +1.0 X , + 0.3Y, + 0.3 Z) EARTH PRESSURE
DIRECTION
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , + 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
CONSTRUCTION COMPLETE
CONDITION & EMPTY RESERVOIR HYDRO-MECHANICAL LOAD ON ROOF SLAB
3
WITH EQ IN ( +1.0 X , - 0.3Y, + 0.3 Z) EARTH PRESSURE
DIRECTION
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
CONSTRUCTION COMPLETE
CONDITION & EMPTY RESERVOIR HYDRO-MECHANICAL LOAD ON ROOF SLAB
4
WITH EQ IN ( +0.3 X , + 0.3Y, + 1.0 Z) EARTH PRESSURE
DIRECTION
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
CONSTRUCTION COMPLETE
CONDITION & EMPTY RESERVOIR HYDRO-MECHANICAL LOAD ON ROOF SLAB
5
WITH EQ IN ( +0.3 X , - 0.3Y, + 1.0 Z) EARTH PRESSURE
DIRECTION
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
CONSTRUCTION COMPLETE LIVE LOAD ON THE ROOF SLAB
CONDITION & EMPTY RESERVOIR
6
WITH EQ IN ( +0.3 X , + 0.3Y, - 1.0 Z) HYDRO-MECHANICAL LOAD ON ROOF SLAB
DIRECTION EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
CONSTRUCTION COMPLETE LIVE LOAD ON THE ROOF SLAB
CONDITION & EMPTY RESERVOIR
7
WITH EQ IN ( +0.3 X , - 0.3Y, - 1.0 Z) HYDRO-MECHANICAL LOAD ON ROOF SLAB
DIRECTION EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
RESERVOIR FULL, INTAKE GATE
8 HYDRO-MECHANICAL LOAD ON ROOF SLAB
CLOSED & NO UPLIFT
HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
EARTH PRESSURE
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE
CLOSED & NO UPLIFT WITH EQ IN HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
9
( +1.0 X , + 0.3Y, + 0.3 Z) EARTH PRESSURE
DIRECTION
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
RESERVOIR FULL, INTAKE GATE
CLOSED & NO UPLIFT WITH EQ IN
9
( +1.0 X , + 0.3Y, + 0.3 Z)
DIRECTION

SEISMIC INERTIA IN ( +1.0 X , + 0.3Y, + 0.3 Z) DIRECTION


SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
10 CLOSED & NO UPLIFT WITH EQ IN
( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE
CLOSED & NO UPLIFT WITH EQ IN HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
11
( +0.3 X , + 0.3Y, + 1.0 Z) EARTH PRESSURE
DIRECTION
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
12 CLOSED & NO UPLIFT WITH EQ IN
( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB

RESERVOIR FULL, INTAKE GATE HYDRO-MECHANICAL LOAD ON ROOF SLAB


13 CLOSED & NO UPLIFT WITH EQ IN HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
( +0.3 X , + 0.3Y, - 1.0 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB

RESERVOIR FULL, INTAKE GATE HYDRO-MECHANICAL LOAD ON ROOF SLAB


14 CLOSED & NO UPLIFT WITH EQ IN HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
( +0.3 X , - 0.3Y, - 1.0 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDRO-MECHANICAL LOAD ON ROOF SLAB
15
CLOSED & FULL UPLIFT HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
UPLIFT PRESSURE
EARTH PRESSURE
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
CLOSED & FULL UPLIFT WITH EQ IN
16 UPLIFT PRESSURE
( +1.0 X , + 0.3Y, + 0.3 Z)
DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
RESERVOIR FULL, INTAKE GATE
CLOSED & FULL UPLIFT WITH EQ IN
16
( +1.0 X , + 0.3Y, + 0.3 Z)
DIRECTION

DYNAMIC INCREMENT OF EARTH PRESSURE


SEISMIC INERTIA IN ( +1.0 X , + 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
CLOSED & FULL UPLIFT WITH EQ IN
17 UPLIFT PRESSURE
( +1.0 X , - 0.3Y, + 0.3 Z)
DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
CLOSED & FULL UPLIFT WITH EQ IN
18 UPLIFT PRESSURE
( +0.3 X , + 0.3Y, + 1.0 Z)
DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
CLOSED & FULL UPLIFT WITH EQ IN
19 UPLIFT PRESSURE
( +0.3 X , - 0.3Y, + 1.0 Z)
DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE
CLOSED & FULL UPLIFT WITH EQ IN HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
20
( +0.3 X , + 0.3Y, - 1.0 Z) UPLIFT PRESSURE
DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
RESERVOIR FULL, INTAKE GATE
CLOSED & FULL UPLIFT WITH EQ IN HYDROSTATIC PRESSURE WHEN INTAKE GATE IS CLOSED
21
( +0.3 X , - 0.3Y, - 1.0 Z) UPLIFT PRESSURE
DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS CLOSED
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
NORMAL OPERATIONS , FULL HYDRO-MECHANICAL LOAD ON ROOF SLAB
22
UPLIFT HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
UPLIFT PRESSURE
EARTH PRESSURE
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB

NORMAL OPERATIONS , FULL HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN


23 UPLIFT WITH EQ IN ( +1.0 X , + 0.3Y, UPLIFT PRESSURE
+ 0.3 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , + 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB

NORMAL OPERATIONS & FULL HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
24 UPLIFT WITH EQ IN ( +1.0 X , - 0.3Y, UPLIFT PRESSURE
+ 0.3 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB

NORMAL OPERATIONS & FULL HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
25 UPLIFT WITH EQ IN ( +0.3 X , + 0.3Y, UPLIFT PRESSURE
+ 1.0 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB

NORMAL OPERATIONS & FULL HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
26 UPLIFT WITH EQ IN ( +0.3 X , - 0.3Y, UPLIFT PRESSURE
+ 1.0 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
NORMAL OPERATIONS & FULL HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
27 UPLIFT WITH EQ IN ( +0.3 X , + 0.3Y,
- 1.0 Z) DIRECTION UPLIFT PRESSURE
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
NORMAL OPERATIONS & FULL HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
28 UPLIFT WITH EQ IN ( +0.3 X , - 0.3Y, -
1.0 Z) DIRECTION UPLIFT PRESSURE
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
NORMAL OPERATIONS & FULL
28 UPLIFT WITH EQ IN ( +0.3 X , - 0.3Y, -
1.0 Z) DIRECTION

SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, - 1.0 Z) DIRECTION


SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
29 NORMAL OPERATIONS , NO UPLIFT HYDRO-MECHANICAL LOAD ON ROOF SLAB
HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
EARTH PRESSURE
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
NORMAL OPERATIONS , NO UPLIFT HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
30 WITH EQ IN ( +1.0 X , + 0.3Y, + 0.3 Z)
DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , + 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
NORMAL OPERATIONS & NO HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
31 UPLIFT WITH EQ IN ( +1.0 X , - 0.3Y,
+ 0.3 Z) DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +1.0 X , - 0.3Y, + 0.3 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
NORMAL OPERATIONS & NO HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
32 UPLIFT WITH EQ IN ( +0.3 X , + 0.3Y,
+ 1.0 Z) DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB
HYDRO-MECHANICAL LOAD ON ROOF SLAB
NORMAL OPERATIONS & NO HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
33 UPLIFT WITH EQ IN ( +0.3 X , - 0.3Y,
+ 1.0 Z) DIRECTION EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
DYNAMIC INCREMENT OF EARTH PRESSURE
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, + 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB

NORMAL OPERATIONS & NO HYDRO-MECHANICAL LOAD ON ROOF SLAB


34 UPLIFT WITH EQ IN ( +0.3 X , + 0.3Y, HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
- 1.0 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
SEISMIC INERTIA IN ( +0.3 X , + 0.3Y, - 1.0 Z) DIRECTION
SELF WEIGHT OF STRUCTURE
LIVE LOAD ON THE ROOF SLAB

NORMAL OPERATIONS & NO HYDRO-MECHANICAL LOAD ON ROOF SLAB


35 UPLIFT WITH EQ IN ( +0.3 X , - 0.3Y, - HYDROSTATIC PRESSURE WHEN INTAKE GATE IS OPEN
1.0 Z) DIRECTION
EARTH PRESSURE
HYDRODYNAMIC WATER PRESSURE WHEN INTAKE GATE IS OPEN
SEISMIC INERTIA IN ( +0.3 X , - 0.3Y, - 1.0 Z) DIRECTION
END WALL

ROOF SLAB

BREAST WALL

RAFT

TRASHRACK PIER

SIDE WALL

END PIER
BREAST WALL
END PIER -2

SIDE WALL

EN
D
W
AL
L

SIDE WALL

END PIER -1
INTERMEDIATE
PIER

You might also like