Professional Documents
Culture Documents
DATA PROVIDED:
SAFE BEARING CAPACITY (AS PER SOIL REPORT) 100 kN/m2 As per the soil test report
COEFF. OF FRICTION BETWEEN SOIL AND CONCRETE = 0.5 As per Cl. 706.3.4 of IRC:78-2004
GRADE OF CONCRETE = M25 As Per RFP _ Page No - 253
GRADE OF STEEL REINFORCEMENT = Fe500 As Per RFP _ Page No - 254
PART-1 DESIGN CONSTANT
CONCRETE CHAR. COMP. STRENGTH (fck) 25 N/mm2
YIELD STRENGHT OF STEEL REINFORCEMENT (fy) 500 N/mm2
LIMITING MOMENT (Mu,lim) = 0.133 fck.b.d2 As Per IS:456-2000 , Annex G
CLEAR COVER ON EARTH RETAINING FACE = 50 mm As per Cl. 26.4 of IS:456-2000
PART-2 PROPERTIES OF RETAINED SOIL
UNIT WEIGHT OF THE FILLIED SOIL (γ)= 18 kN/m3 As per Table 1 of IS:875- Part 1
ANGLE OF REPOSE OF FILLED SOIL (φ) = 30 DEGREE As per the soil test report
COEFF. OF ACTIVE EARTH (1 − 𝑆𝑖𝑛 𝜑)
𝐾 = = 0.333 Based on Rankine theory
PRESSURE (1 + 𝑆𝑖𝑛 𝜑)
PART-3 PRELIMINARY DIMENSIONS OF WALL
DEPTH OF FOUNDATION BELOW THE NGL = 1.800 m
CLEAR SPAN LENGTH = 1.300 m
OVERALL DEPTH THE OF BASE SLAB = 0.200 m
THICKNESS OF THE WALL AT BASE = 200 mm
THICKNESS OF THE WALL AT TOP = 200 mm
OVERALL DEPTH THE OF TOP SLAB = 0.200 m
PART-4 LOADING
A) ACTIVE SOIL PRESSURE ON WALL WHEN TANK IS EMPTY + SURCHARGE LOAD
10.800 7.200
18.000
18.000
Page 1 of 4
MAA SAMLESHWARI TEMPLE COMPLEX
BOX TYPE DRAIN DESING FOR upto 1.8 m HEIGHT
Page 2 of 4
MAA SAMLESHWARI TEMPLE COMPLEX
BOX TYPE DRAIN DESING FOR upto 1.8 m HEIGHT
FACTORED SHEAR
17.06 kN
FORCE AT BASE (Vu)
𝑉
NOMINAL SHEAR τ =
𝑏 ×𝑑 0.12 N/mm2
STRESS=
Page 3 of 4
MAA SAMLESHWARI TEMPLE COMPLEX
BOX TYPE DRAIN DESING FOR upto 1.8 m HEIGHT
𝑉
NOMINAL SHEAR τ =
𝑏 ×𝑑 0.19 N/mm2
STRESS=
𝑉
NOMINAL SHEAR τ =
𝑏 ×𝑑 0.20 N/mm2
STRESS=
Page 4 of 4
Calculations for crackwidth as per IS 3370(PART 2) : 2021
IS 456 ANNEX F
Heritage drain
Description Remarks
Designation F1 Factored
Max service Horizontal B.M on retained face of the slab due
to water Mser 8.25 kN.m 12.38
Maximum service shear force induced on the retaining face Vser 19.5 kN 29.25
Overall depth of section provided D 200 mm
Width of section provided b 1000 mm
Characteristic strength of steel fy 500 N/mm2
Characteristic strength of concrete fck 25 N/mm2
Diameter of steel bar provided ф 10 mm
Spacing of bars provided s 200 mm
Modulus of elasticity for steel Es 200000.00 N/mm2
Modulus of elasticity for concrete Ec 25000.00 N/mm2
As per IS 456:2000
Clear cover to bars provided Cmin 50 mm Cl. 26.4
As per IS 456:2000
Modular ratio obtained m 11.00 Annex B
Fall In temperature between the hydration peak and As per IS 456:2000 & IS
o
ambient T1 15 C 875 part 5
Percentage of tensile steel provided on retaining face pt 0.20 % > Min steel; safe
Depth of neutral axis obtained x 31.34 mm
Tensile stress in reinforcement obtained fst 156.20 N/mm2 <0.6*fy ; Safe
Compressive stress in concrete obtained fc 3.91 N/mm2 <0.4*fck; Safe
Strain in steel at the level of reinforcement Єs 0.000781
Strain in concrete at the extreme fibre end of section Є1 0.0011589
Є2=bt(D-x)(a'-x)/(3EsAs(d-x)
Strain due to stiffening effect of concrete between cracks Є2 0.0010622 IS 456-2000 Annex F
Average strain in concrete where cracking in been Єm = Є1-Є2
considered Єm 9.668E-05 IS 456-2000 Annex F
Distance from the point considered to the nearest bar acr 109.13 mm
Page 1 of 1