Professional Documents
Culture Documents
For Air
Series VCA
Improved durability (Nearly twice the life of the previous series)
Resistance of moving parts has been reduced. VC
Service life and wear resistance are improved. VDW
Large flow rate: TV factor 0.33 to 2.11 VQ
VX2
Compact: Single valve volume reduced by –13% (Class 2)
VX
Weight reduced by –25% (Class 2)
Manifold length reduced by –22% (Class 2 : 5 stations) (SMC comparison) VX3
Built-in surge voltage suppressor VXA
LVN
Special construction reduces
TI/
operating resistance. TIL
∗ When shipped from our factory, the
electrical entry is set in the IN port PA
side.
17-2-7
Series VCA
Precautions
Be sure to read before handling. Refer to page 17-6-3 Safety Instructions and Solenoid Valve Precautions.
17-2-8
Direct Operated 2 Port Solenoid Valve
For Air Series VCA
Precautions
Be sure to read before handling. Refer to page 17-6-3 for Safety Instructions and Solenoid Valve Precautions.
Glossary
Pressure
1. Maximum operating pressure differential
This indicates the maximum pressure differential (inlet and
outlet pressure differential) which can be allowed for operation VC
with the valve closed or open.
2. Maximum operating pressure VDW
This indicates the limit of pressure that can be applied inside
the pipelines. (Line pressure)
VQ
3. Withstand pressure
The pressure which must be withstood without a drop in VX2
performance after returning to the operating pressure range
(The value under the prescribed conditions).
VX
Electricity
1. Surge voltage VX3
A high voltage which is momentarily in the shut-off unit by
shutting off the power. VXA
VN
LVC
Others
1. Material
LVA
HNBR: Nitrile hydride rubber
LVH
2. JIS symbol
In the JIS symbol ( ) IN and OUT are in a blocked LVD
condition ( ), but actually in the case of reverse pressure
(OUT > IN), there is a limit to the blocking capability. LVQ
( ) is used to indicate that blocking of reverse pressure is
not possible. LQ
LVN
TI/
TIL
PA
PAX
PB
17-2-9
For details about certified products
conforming to international standards,
visit us at www.smcworld.com.
Series VCA
How to Order Valves (Single Unit)
VC A 2 1 1 G 3 02
For air
Option
Series
Nil None
2 Class 2
F Foot type bracket
3 Class 3
∗ When a bracket is separately
4 Class 4
required, refer to Table 2 given
below.
Valve type
Thread type (for single unit only)
N.C.
Nil Rc
OUT(2)
F G
1 N NPT
T NPTF
IN(1)
Port size
Fluid Symbol Port size Class 2 Class 3 Class 4
Nil General air 02 1/4 (8A) 앪 앪 —
A Dry air 03 3/8(10A) — 앪 앪
04 1/2(15A) — — 앪
06 3/4(20A) — — 앪
Voltage
1 100 VAC
2 200 VAC Orifice size
3 110 VAC Symbol Orifice size (mmø) Class 2 Class 3 Class 4
4 220 VAC 3 3 앪 — —
5 24 VDC 4 4 — 앪 —
6 12 VDC 5 5 앪 — 앪
36 230 VAC 7 7 — 앪 앪
∗ Please consult with 10 10 — — 앪
SMC regarding other ∗ Refer to the below table for orifice and port size combinations.
voltages.
Electrical entry Manual override
G – Grommet C – Conduit Nil None
B Slotted locking type (Tool required)
17-2-10
Direct Operated 2 Port Solenoid Valve
For Air Series VCA
Standard Specifications
Valve construction Direct operated poppet
Fluid Air, Inert gas, Low vacuum (133 Pa·abs)
Withstand pressure (MPa) 2.0
Body material Al
specifications
Seal material HNBR
Ambient temperature (°C) –20 to 60
Valve
Fluid temperature (°C) –10 to 60 (No freezing)
Enclosure Dusttight, low jetproof (equivalent to IP65)
VC
Environment Location without corrosive or explosive gases
VDW
Valve leakage cm3/min (ANR) 0.2 or less
Mounting orientation Unrestricted VQ
(2)
Vibration/Impact resistance (m/s2) 30/150 or less
Rated voltage 24 VDC, 12 VDC, 100 VAC, 110 VAC, 200 VAC, 220 VAC, 230 VAC (50/60 Hz) VX2
±10% of rated voltage
specifications
PB
Please contact SMC for detailed
specifications, delivery, and price.
Made to Order Specifications
Oil-free specifications
2
VCA 3 1A––– ––X15
4
17-2-11
Series VCA
Construction
t
Component Parts
No. Description Material
IN q Solenoid coil —
w Armature assembly Stainless steel, HNBR, PPS
e Return spring Stainless steel
r O-ring HNBR
t Body Aluminum
J
1.5
A
C 4-ø6
B
D
2-øH
Valve mounting hole
17-2-12
Direct Operated 2 Port Solenoid Valve
For Air Series VCA
Dimensions
Grommet: G Conduit: C
D ≅300 Q F D ≅280 Q F
G1/2
VC
C
R
C
R
IN VDW
E
E
A
Manual override
B A B
VQ
2-P 2-P
Port size Port size VX2
Manual override
VX
2
VX3
L
L
VXA
K 2-M K 2-M
Thread depth 6 Thread depth 6
VN
LVC
LVA
25
C
≅44
R
C
TI/
R
TIL
G1/2
PA
E
E
G1/2
A
2-P
B A
2-P
B PAX
D (S)
Port size Port size
PB
Port size G1/2
K 2-M K 2-M
Thread depth 6 Thread depth 6
(mm)
Electrical entry
P
Model
Port size A B C D E F K L M Grommet: G Conduit: C DIN terminal: D Conduit terminal: T
Q R Q R Q R S Q R S U
VCA21 1/4 18 41 64 28 11.5 15 20.5 12.8 M4 27 40 46 36 63 35 51 98 36 68 81
VCA31 1/4, 3/8 24 50 76 34 14 17 25 19 M5 30 48 50 44 66 42 54 101 44 71 91.5
3/8, 1/2 30 60 86 40 15 20 30 23 M5 32 56 52 53 69 51 57 104 53 74 101
VCA41
3/4 35 68 91 40 17.5 20 34 23 M5 32 58.5 52 55.5 69 53.5 57 104 55.5 74 103.5
17-2-13
Series VCA
How to Order Manifold (VCA20)
How to Order Manifold Assembly
VV2C A 2 02 02 Enter the mounting valve and option part numbers
under the manifold base part number.
For air <Ordering Example>
VV2CA2-0502 ··········· 1 set Manifold part no.
Electrical entry ∗ VCA23-5G-3 ··········· 5 sets Valve part no.
Series Nil Grommet, Conduit, DIN (Stations 1 to 5)
“∗” is the symbol for
2 Class 2 T Conduit terminal
assembly. Add an “∗” Enter together in
in front of the part order, counting from
Stations numbers for solenoid station 1 on the D
02 2 stations valves, etc., to be side.
IN port direction mounted.
...
...
Nil Side
10 10 stations e
A Front sid
U
5
OUT port size 4
02 1/4 (8A) 3
2
Thread type 1
e
Nil Rc sid
D
F G
N NPT
T NPTF
VC A 2 3 1 G 3
For air Orifice size
Symbol Orifice size (mmø)
3 3
Series 5 5
2 Class 2
Manual override
Valve type Nil None
3 N.C. for manifold B Slotted locking type (tool required)
17-2-14
Direct Operated 2 Port Solenoid Valve
For Air Series VCA
How to Order Manifold (VCA30/40)
How to Order Manifold Assembly
VV2C A 3 02 Enter the mounting valve and option part numbers
under the manifold base part number.
For air <Ordering Example>
IN port direction VV2CA3-05 ··············· 1 set Manifold part no.
∗ VCA35-5G-4-03 ······ 5 sets Valve part no.
Series Nil Side (Stations 1 to 5)
A Front “∗” is the symbol for
3 Class 3 assembly. Add an “∗” Enter together in
4 Class 4 in front of the part order, countingfrom VC
Thread type numbers for solenoid station 1 on the D
valves, etc., to be side.
Stations Nil Rc
mounted.
VDW
F G
02 2 stations
N NPT
Us
ide VQ
...
...
T NPTF 5
10 10 stations 4
3 VX2
2
ide
1 VX
Ds
VX3
VXA
VN
LVC
How to Order Valves (VCA30/40)
LVA
VC A 3 5 1 G 4 03 LVH
LVD
For air Thread type
Nil Rc LVQ
Series F G
3 Class 3 N NPT
LQ
4 Class 4 T NPTF
LVN
Valve type Port size (OUT)
5 N.C. for manifold Symbol Size Class 3 Class 4 TI/
03 3/8 (10A) 앪 —
TIL
04 1/2 (15A) 앪 앪
Fluid 06 3/4 (20A) — 앪 PA
Nil General air
A Dry air
Orifice size PAX
Symbol Orifice size (mmø) Class 3 Class 4
Voltage 4 4 앪 — PB
1 100 VAC 5 5 — 앪
2 200 VAC 7 7 앪 앪
3 110 VAC 10 10 — 앪
4 220 VAC
5 24 VDC
6 12 VDC
Manual override
36 230 VAC Nil None
B Slotted locking type (Tool required)
∗ Please consult with SMC
regarding other voltages.
Electrical entry
G Grommet
C Conduit
T Conduit terminal
TL Conduit terminal with indicator light
D DIN terminal
DL DIN terminal with indicator light
DO DIN terminal (without connector)
∗ All types equipped with surge voltage suppressor.
17-2-15
Series VCA
Dimensions: VCA20 Manifold
L2 (Front ported)
L1 (Front ported) 5
L2 (Side ported)
2-ø 5.6 L1 (Side ported) 5 2-Rc3/8
Manual override 12.5
Mounting holes Manual override IN port (Side ported)
2
12
14
14
27
33
26.4
48
51
62
(68)
(98)
l = 280
l = 300
25
2-3/8
72
IN port
55
(Front ported)
38.5
42
37
25
P = 28.5 24.5
12.5
n-1/4
OUT port Mounting valve: for conduit terminal (P = 34.5) 25 19.5
17-2-16
Direct Operated 2 Port Solenoid Valve
For Air Series VCA
Dimensions: VCA30/40 Manifold
L2 (Front ported)
5.5 2-1/2(VCA30), 3/4(VCA40)
L1 (Front ported)
IN port (Side ported)
L2 (Side ported)
L1 (Side ported) 5.5 F
E
Manual override
2-ø6.4
Mounting holes VC
C
G
B
H
1
VDW
A
Q
VQ
U
S
V
(X)
(Y)
VX2
VX
VX3
= 280
l = 300
25
VXA
l
D side U side
Stations 1 2 3 4 5 n
VN
LVC
For manual override
J2 LVA
LVH
Z
Manual override
LVD
N
R
W
T
16
LVQ
1 1
M
LQ
L
2 2 2 2
Dimensions (mm)
Electrical entry
Model A B C E F G H J1 J2 J3 K L M N Grommet: G Conduit: C DIN terminal: D Conduit terminal: T
Q R S T U V W X Y Z
VV2CA3 55 26 17 19.5 33 26 35 23.5 39.5 57.5 35 26.5 41.5 50 30 36 50 32 54 66 30 71 101 65.5
VV2CA4 62 31 19 21 39.5 31 43 27 43.5 65.5 41 29 48 55 32 41 52 38 57 69 36 74 104 71
17-2-17
Series VCA
Manifold Exploded View
Series VCA20
Manifold body
Gasket
w
Manifold base A port side
Series VCA30/40
r
e
w
Series VCA30 q Series VCA40
No. Part no. Description Material No. Part no. Description Material
AXT632-69-1 Mounting screw (side port) AXT632-69-1 Mounting screw (side port)
q Steel q Steel
AXT632-69-2 Mounting screw (front port) AXT632-69-2 Mounting screw (front port)
VVCA30-3A-04-2 End plate assembly (D side, side port) VVCA40-3A-06-2 End plate assembly (D side, side port)
w Aluminum w Aluminum
VVCA30-3A-04-1 End plate assembly (D side, front port) VVCA40-3A-06-1 End plate assembly (D side, front port)
e OR-2200-200-H O-ring (for VCA30) HNBR e OR-3200-200-H O-ring (for VCA40) HNBR
r VCA35쏔-쏔쏔-쏔-쏔쏔 Manifold valve (2) r VCA45쏔-쏔쏔-쏔-쏔쏔 Manifold valve (2)
t VVCA30-6-n Tie-rod Steel t VVCA40-6-n Tie-rod Steel
VVCA30-4A-04-2 End plate assembly (U side, side port) VVCA40-4A-06-2 End plate assembly (U side, side port)
y Aluminum y Aluminum
VVCA30-4A-04-1 End plate assembly (U side, front port) VVCA40-4A-06-1 End plate assembly (U side, front port)
Note 2) O-ring e is included with manifold valve r. Note 2) O-ring e is included with manifold valve r.
17-2-18
Direct Operated 2 Port Solenoid Valve
For Air Series VCA
Manifold Option Parts
Blanking plate assembly (VCA20)
VVCA20 4A
This is used when a blanking plate is mounted on a manifold as
preparation for a planned valve installation. (With gasket, 2
mounting screws)
VC
VDW
Blanking block assembly (VCA30, 40) VQ
VVCA 3 0 2A 00 VX2
3 Series VCA30 VX
4 Series VCA40
Tie-rod for additional stations (Set of 2 pcs for 1 station) (VCA30, 40) LVC
VVCA 3 0 6 1A LVA
3 Series VCA30 LVH
4 Series VCA40
PA
PAX
PB
17-2-19