You are on page 1of 8

ARV 6 25kw

ARV-H250/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H250/SR1MV

HP 8
Cooling kW 25.2
Capacity Full Process

kW 25.2 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 5.31
EER W/W 4.75
Electric Data Heating Input kW 4.60
COP W/W 5.48
SEER 6.7
WIFI Control
SCOP 4.2
Air Flow Volume m /h3
12000
Performance
Noise Level dB(A) ≤58
Type DC Inverter
Compressor
1
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
1
Max. No. of Indoor Units unit 13
% 50~200
Net mm 990×765×1635
Dimension(WxDxH)
Packing mm 1030×825×1865
Net kg 215
Weight Remote Control Central Control Silent
Gross kg 225
Refrigerant Type R410a
Liquid Side mm(inch) 12.7(1/2)
Pipe Diameter
Gas Side mm(inch) 22.2(7/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 28kw
ARV-H280/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H280/SR1MV

HP 10
Cooling kW 28
Capacity Full Process

kW 28 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 6.11
EER W/W 4.58
Electric Data Heating Input kW 5.23
COP W/W 5.35
SEER 6.5
WIFI Control
SCOP 4.0
Air Flow Volume m /h3
12000
Performance
Noise Level dB(A) ≤58
Type DC Inverter
Compressor
1
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
1
Max. No. of Indoor Units unit 16
% 50~200
Net mm 990×765×1635
Dimension(WxDxH)
Packing mm 1030×825×1865
Net kg 215
Weight Remote Control Central Control Silent
Gross kg 225
Refrigerant Type R410a
Liquid Side mm(inch) 12.7(1/2)
Pipe Diameter
Gas Side mm(inch) 22.2(7/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 33kw
ARV-H330/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H330/SR1MV

HP 12
Cooling kW 33.5
Capacity Full Process

kW 33.5 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 8.48
EER W/W 3.95
Electric Data Heating Input kW 6.38
COP W/W 5.25
SEER 7.2
WIFI Control
SCOP 4.2
Air Flow Volume m /h3
12000
Performance
Noise Level dB(A) ≤58
Type DC Inverter
Compressor
1
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
1
Max. No. of Indoor Units unit 20
% 50~200
Net mm 990×765×1635
Dimension(WxDxH)
Packing mm 1030×825×1865
Net kg 230
Weight Remote Control Central Control Silent
Gross kg 240
Refrigerant Type R410a
Liquid Side mm(inch) 12.7(1/2)
Pipe Diameter
Gas Side mm(inch) 22.2(7/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 40kw
ARV-H400/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H400/SR1MV

HP 14
Cooling kW 40
Capacity Full Process

kW 40 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 9.90
EER W/W 4.04
Electric Data Heating Input kW 8.25
COP W/W 4.85
SEER 6.5
WIFI Control
SCOP 4.3
Air Flow Volume m /h3
14000
Performance
Noise Level dB(A) ≤61
Type DC Inverter
Compressor
1
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
2
Max. No. of Indoor Units unit 23
% 50~200
Net mm 1340×765×1635
Dimension(WxDxH)
Packing mm 1395×815×1865
Net kg 265
Weight Remote Control Central Control Silent
Gross kg 280
Refrigerant Type R410a
Liquid Side mm(inch) 15.88(5/8)
Pipe Diameter
Gas Side mm(inch) 28.6(1΄1/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 45kw
ARV-H450/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H450/SR1MV

HP 16
Cooling kW 45
Capacity Full Process

kW 45 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 11.82
EER W/W 3.81
Electric Data Heating Input kW 9.78
COP W/W 4.60
SEER 6.3
WIFI Control
SCOP 4.2
Air Flow Volume m /h3
14000
Performance
Noise Level dB(A) ≤61
Type DC Inverter
Compressor
1
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
2
Max. No. of Indoor Units unit 26
% 50~200
Net mm 1340×765×1635
Dimension(WxDxH)
Packing mm 1395×815×1865
Net kg 265
Weight Remote Control Central Control Silent
Gross kg 280
Refrigerant Type R410a
Liquid Side mm(inch) 15.88(5/8)
Pipe Diameter
Gas Side mm(inch) 28.6(1΄1/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 50kw
ARV-H500/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H500/SR1MV

HP 18
Cooling kW 50.4
Capacity Full Process

kW 50.4 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 12.63
EER W/W 3.99
Electric Data Heating Input kW 11.69
COP W/W 4.31
SEER 6.0
WIFI Control
SCOP 4.0
Air Flow Volume m /h3
16000
Performance
Noise Level dB(A) ≤63
Type DC Inverter
Compressor
2
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
2
Max. No. of Indoor Units unit 30
% 50~200
Net mm 1340×765×1635
Dimension(WxDxH)
Packing mm 1395×815×1865
Net kg 330
Weight Remote Control Central Control Silent
Gross kg 345
Refrigerant Type R410a
Liquid Side mm(inch) 15.88(5/8)
Pipe Diameter
Gas Side mm(inch) 28.6(1΄1/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 56kw
ARV-H560/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H560/SR1MV

HP 20
Cooling kW 56
Capacity Full Process

kW 56 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 15.34
EER W/W 3.65
Electric Data Heating Input kW 13.83
COP W/W 4.05
SEER 5.6
WIFI Control
SCOP 3.6
Air Flow Volume m /h3
16000
Performance
Noise Level dB(A) ≤63
Type DC Inverter
Compressor
2
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
2
Max. No. of Indoor Units unit 33
% 50~200
Net mm 1340×765×1635
Dimension(WxDxH)
Packing mm 1395×815×1865
Net kg 330
Weight Remote Control Central Control Silent
Gross kg 345
Refrigerant Type R410a
Liquid Side mm(inch) 15.88(5/8)
Pipe Diameter
Gas Side mm(inch) 28.6(1΄1/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃
ARV 6 61kw
ARV-H610/SR1MV

Modular VRF - ARV


Full DC Inverter
SPECIFICATIONS FEATURES
Model Outdoor 380~415V ARV-H610/SR1MV

HP 22
Cooling kW 61.5
Capacity Full Process

kW 61.5 By DC Drive

Power Supply V~,Hz,Ph 380~415,50,3 Wired Control Full Process By DC Drive


Cooling Input kW 18.90
EER W/W 3.25
Electric Data Heating Input kW 15.44
COP W/W 3.98
SEER 5.2
WIFI Control
SCOP 3.5
Air Flow Volume m /h3
16000
Performance
Noise Level dB(A) ≤63
Type DC Inverter
Compressor
2
Type DC motor
Fan Motor Low Ambient Cooling Fire-proof Electric Box 24-hour Timer
2
Max. No. of Indoor Units unit 33
% 50~200
Net mm 1340×765×1635
Dimension(WxDxH)
Packing mm 1395×815×1865
Net kg 330
Weight Remote Control Central Control Silent
Gross kg 345
Refrigerant Type R410a
Liquid Side mm(inch) 15.88(5/8)
Pipe Diameter
Gas Side mm(inch) 28.6(1΄1/8)
Cooling C -15~52
C -25~24 Special design economic locking fu through outdoor PCB
switch se If work in economic lock, AC lowest work cooling

temperature will keep in 26 C and highest hea temperature

keep 20 C.

26℃

Excellent In EER&COP
ARV 6 Series achieves the industry’s top class energy efficiency in cooling
Wide Opera ge
andhea by u all DC inverter compressors, and high efficiency heat exchanger. 。
The cooling EER is up to 4.75 and the hea COP is up to 5.48 in the 8HP category. The unit could operate perfectly between 52 C in hot

summer and -25 C in cold winter making you feel like
spring all year around, advanced system design and strict
system matching and test. (cooling in -15℃ )

-25℃ 52℃