Professional Documents
Culture Documents
a r t i c l e i n f o a b s t r a c t
Article history: Contaminated soils and sediments with polychlorinated biphenyls (PCB) are an important environmental
Received 11 November 2014 problem due to the persistence of these synthetic aromatic compounds and to the lack of a cost-effective
Received in revised form and sustainable remediation technology. Recently, a new experimental setup has been proposed using
7 January 2015
electrodialytic remediation and iron nanoparticles. The current work compares the performance of this
Accepted 10 January 2015
Available online xxx
new setup (A) with conventional electrokinetics (setup B). An historically contaminated soil with an
initial PCB concentration of 258 mg kg1 was treated during 5, 10, 20 and 45 d using different amounts of
iron nanoparticles in both setups A and B. A PCB removal of 83% was obtained in setup A compared with
Keywords:
Electrokinetics (EK)
58% of setup B. Setup A also showed additional advantages, such as a higher PCB dechlorination, in a
Electrodialytic remediation (EDR) shorter time, with lower nZVI consumption, and with the use of half of the voltage gradient when
nZVI compared with the traditional setup (B). Energy and nZVI costs for a full-scale reactor are estimated at 72
Polychlorinated biphenyls V for each cubic meter of PCB contaminated soil treated on-site, making this technology competitive
PCB when compared with average off-site incineration (885 V m3) or landfilling (231 V m3) cost in Europe
and in the USA (327 USD m3).
© 2015 Elsevier Ltd. All rights reserved.
http://dx.doi.org/10.1016/j.jenvman.2015.01.015
0301-4797/© 2015 Elsevier Ltd. All rights reserved.
Please cite this article in press as: Gomes, H.I., et al., Treatment of a suspension of PCB contaminated soil using iron nanoparticles and electric
current, Journal of Environmental Management (2015), http://dx.doi.org/10.1016/j.jenvman.2015.01.015
2 H.I. Gomes et al. / Journal of Environmental Management xxx (2015) 1e6
in which iron acts as a reductant (electron donor) for the removal of acetone were Pestinorm (VWR BDH Prolabo). Hydrochloric (37.6%),
chlorine. This reaction is similar to the process occurring during nitric (65%) and sulfuric (95-7%) acids were trace metal grade.
iron corrosion, with the beneficial effects of transforming chlori- Anhydrous Na2SO4, KMnO4, NaCl, and silica gel (silicic acid) were
nated pollutants. Still a 95% PCB dechlorination in soils was just lab grade. Silica gel was cleaned up before use according to the
achieved at high temperatures (300 C) (Varanasi et al., 2007) and a USEPA method 3630C. The water was deionized with a Milli-Q plus
removal efficiency of 98% with 100 mg of nZVI was obtained at system from Millipore (Bedford, MA, USA). A polyacrylic acid (PAA)
600 C (Liu et al., 2014). In field applications, nZVI can be injected in slurry-stabilized suspension of zero valent iron nanoparticles
the aquifers through injection wells, or incorporated to topsoil to (NANOFER 25S, NANO IRON, s.r.o., Rajhrad, Czech Republic) was
adsorb or degrade pollutants (Crane and Scott, 2012). Results in used in the experiments, with 50 nm average particles size, an
aquifers show that nZVI have limited mobility, ranging from 1 m average surface area of 20e25 m2 g1, a particle size distribution of
(Kocur et al., 2014) to 6e10 m (Zhang and Elliott, 2006). 20e100 nm and iron content in the range of 80e90 wt. %.
One of the methods tested to enhance nZVI mobility was the use
of low-level direct current (DC) (Jones et al., 2010; Pamukcu et al.,
2008; Yang et al., 2007), using the same principles of electroki- 2.2. Soil characterization
netic remediation (EKR). Electroremediation and nZVI were com-
bined by Fan et al. (2013) and they obtained a 20% PCB removal The contaminated soil used in the experiments was provided by
from soils after 14 d using Fe/Pd bimetallic nanoparticles in a hazardous waste operator in Portugal and is a mixture of
conjunction with surfactants. contaminated soils from industrial sites with transformers oils
In a recent work (Gomes et al., 2014a), we presented a new spills. The soil characterization methods used were described in
experimental setup for on-site or ex-situ electrokinetic treatment of Jensen et al. (2007). The elemental analysis were made using
PCB contaminated soils in which the soil is kept in suspension with Inductively Coupled Plasma-Atomic Emission Spectrometer (ICP)
the simultaneous addition of nZVI and surfactants (saponin and on an Agilent ICP-OES Varian 720-ES equipment. Table 1 presents
Tween 80). In the current work the main objectives were to: i) the physical and chemical characteristics of the soil used in the
assess the effectiveness for the dechlorination of PCB by nZVI of the experiments. According to the United States Department of Agri-
new setup in comparison with the traditional cell used in electro- culture Natural Resources Conservation Service, this soil is classi-
kinetic setups; ii) test if longer EKR experiments with nZVI could fied as “very strongly alkaline” and this alkaline pH can be due to
increase PCB dechlorination; and to iii) evaluate the effect of using
direct electric current.
Table 1
Physical and chemical characteristics of the soil.
Parameter
Please cite this article in press as: Gomes, H.I., et al., Treatment of a suspension of PCB contaminated soil using iron nanoparticles and electric
current, Journal of Environmental Management (2015), http://dx.doi.org/10.1016/j.jenvman.2015.01.015
H.I. Gomes et al. / Journal of Environmental Management xxx (2015) 1e6 3
the presence of strong basis of industrial origin. The soil tested is a variable duration in setup B (as the maximum duration of the ex-
mixture of industrial contaminated soils, so it is also possible to periments in the literature was 14 d (Fan et al., 2013)). The iron
have in the mixture fly ashes from coal fired boilers or power nanoparticles were placed in the center of both cells. In setup B
plants, rich in calcium oxide (CaO), which readily dissolves in water (experiments A, B, C and D), the central reservoir was filled at the
to form Ca(OH)2 (Lopareva-Pohu et al., 2011). The PCB concentra- beginning of the experiments with nZVI. In experiment C more
tions measured are above the guidance values for total PCB in nZVI was added (2 mL), in days 7 and 9, to test if the addition of
Denmark, even though only the most common congeners in envi- fresh nanoparticles could enhance the PCB dechlorination. In setup
ronmental samples were measured. In Denmark, the limit for soil A (experiments E and F), two injections of 5 mL nZVI were made at
quality is 0.02 mg kg1 total PCB and if the concentration exceeds 24 and 48 h, when the soil suspension pH was neutral. The elec-
50 mg kg1 the soil is classified as hazardous waste (Jensen, 2009). trolyte used in all experiments was 102 M NaCl. In the electrodi-
The soil was homogenized, air dried and sieved, and only the par- alytic setup (experiment F), the catholyte pH was manually
ticles with size <2 mm were used in the experiments. maintained approximately at 2 by the periodic addition of HCl 5 M
to avoid alkaline pH in the catholyte.
2.3. PCB analysis The current between electrodes, the soil suspension pH and in
the electrolytes were measured every 24 h. In setup A at the end of
For PCB analysis, the soil extraction method used was the USEPA the experiments, the suspension from the central compartment
method 3550C, in which 10 g of soil was extracted with 3 30 mL was filtered by gravity through 0.45 mm filter paper. In setup B
of acetone-hexane (1:1) in a glass vial by ultrasonication (20 kHz) samples from the anode and the cathode side were collected
for 60 min. After vacuum filtration and concentration, the extracts separately. Subsamples were prepared for humidity measurements.
were cleaned following the USEPA methods 3665A and 3630C. For both setups, the soil was air-dried and crushed slightly in a
Aqueous samples (soil filtrate and catholyte) were extracted ac- mortar before the PCB extraction and pH measurements. At the end
cording to the method used by Lowry and Johnson (2004), after of the experiments the Fe contents in the different parts of the cell
adjusting the pH of the acid samples to pH 7 with NaOH. The PCB (membranes, soil, solutions, and electrodes) were determined. The
congeners were analyzed by gas chromatography (GC) with an ECD Fe contents in the CAT membranes and at the electrodes were
detector (HP 6890 Series, HewlettePackard, Palo Alto, California, measured after extraction in 1 M HNO3 and 5 M HNO3, respectively.
USA). The column used was a TRBe5eMS with 30 m 0.25 mm i.d. The Fe was extracted from soil by the sodium dithionite-citrate-
and 0.25 mm film thickness (Phenomenex, Torrance, CA, USA). The bicarbonate method (Mehra and Jackson, 1960) and from the pas-
oven temperature was programmed starting at 70 C for 2 min, sive membranes with concentrated HCl.
increased to 150 C at a rate of 25 C min1 and then increased
4 C min1 to 200 C, 8 C min1 to 280 C where it holds for 4 min
3. Results and discussion
and finally 10 C min1 to 300 C, where it holds for 2 min. Pure
nitrogen was used as the carrier gas. The injector was splitless set at
3.1. Comparison between the two experimental setups
260 C. The injections of 1.00 ml were performed manually.
Please cite this article in press as: Gomes, H.I., et al., Treatment of a suspension of PCB contaminated soil using iron nanoparticles and electric
current, Journal of Environmental Management (2015), http://dx.doi.org/10.1016/j.jenvman.2015.01.015
4 H.I. Gomes et al. / Journal of Environmental Management xxx (2015) 1e6
Fig. 2. Average concentration of the sum of PCB congeners (PCB28, 52, 65, 101, 138, Fig. 3. Evolution of pH in the soil suspension during the experiments using the new
153, 180, 204 and 209) in soil before and after the experiments using conventional electrodialytic setup (A). DC e direct current, nZVI e zero valent iron nanoparticles.
electrokinetics (setup B) and the new electrodialytic setup (A). Percentages on the top
of each column represent PCB removal regarding the sum of congeners analyzed in the
initial soil. PCB e polychlorinated biphenyls, DC e Direct Current, nZVI e zero valent 3.2. Different duration experiments
iron nanoparticles.
Fe2þ
ðaqÞ þ CO2
3ðaqÞ /FeCO3ðsÞ (4)
Direct current can be used to enhance nZVI transport in different
Also, the presence of transformer oil was found to adversely porous matrices or model soils (Gomes et al., 2013b) but, in the
affect the PCB degradation (Chang et al., 2010). Despite the intro- electrodialytic setup (A), the contact between the nanoparticles
duction of Hþ (resultant of hydrolysis in the anode) and the at- and the contaminated soil is ensured by the stirring so the current
mospheric O2 dissolved by the slurry stirring that promotes Fe0 may not be needed for PCB dechlorination. However, results show
oxidation, a higher PCB removal is obtained in the electrodialytic that the experiment with direct current (exp. F) had a much higher
setup (A) compared with the conventional eletrokinetic setup (B). PCB removal (83%) than the experiment just with the iron nano-
In both setups, in none of the aqueous samples (electrolyte and particles (exp. E) (29%). We believe that due to the high pH and
filtrates) PCB were detected. The electrokinetic setup (B) is more buffer capacity of the soil (Table 1 and Fig. 3) in the experiment
prone to nZVI aggregation and settling, as other experiments with without current (exp. E) the soil kept a constant alkaline pH that
molinate contaminated soils showed (Gomes et al., 2014b). promoted the passivation of the iron nanoparticles. On the con-
In other remediation techniques (Beckingham and Ghosh, 2011; trary, in the experiment with current (exp. F) water electrolysis
Li et al., 2013; Vasilyeva et al., 2010; Wu et al., 2012), lower chlo- (eqs. (5) and (6))) produces Hþ in the anode, thus lowering the pH
rinated congeners (tri and tetrachlorobiphenyls) were the ones of the soil slurry
with highest removal. In this study, lower chlorinated congeners
were degraded, namely PCB28, PCB52 and PCB65 (particularly in 2H2O 4e / O2(g) þ 4Hþ E0 ¼ 1.229 V (anode) (5)
setup B), but higher chlorinated congeners were also degraded
Table 3
(Experiment F). In some experiments an increase of PCB65 occurred Soil pH at the end of the experiments in both setups. Initial soil pH is 12.2.
(two, five and six times more the initial amount in the experiments
Setup A Setup B
D, E and F, respectively) likely due to the dechlorination of higher
chlorinated congeners, such as PCB204. In setup B removal per- Exp. Soil pH Exp. Anode side Cathode side
centages for each congener are lower than in setup A. The A 11.28 12.18
dechlorination pathways of congeners by nZVI were proposed by E 9.47 B 12.25 12.07
Chen et al. (2014) for PCB153 and by Gomes et al. (2014a) for F 5.70 C 11.60 11.83
D 11.21 11.69
PCB138 and PCB180.
Please cite this article in press as: Gomes, H.I., et al., Treatment of a suspension of PCB contaminated soil using iron nanoparticles and electric
current, Journal of Environmental Management (2015), http://dx.doi.org/10.1016/j.jenvman.2015.01.015
H.I. Gomes et al. / Journal of Environmental Management xxx (2015) 1e6 5
2H2O þ 2e / H2(g) þ 2OH E0 ¼ 0.828 V (cathode) (6) Basically, considering the energy consumption for the stirring and
electrodialytic remediation of a full-scale reactor for a cubic meter
A slightly acidic pH (4.90e5.10) increases the dechlorination of of contaminated soil and the nZVI costs (at current commercial
PCB by nZVI and nZVI/Pd (Wang et al., 2012). The effect of the prices 61 V kg1), the costs are 72 V. The energy consumption was
acidification of the soil slurry favors the PCB dechlorination when a extrapolated from the lab scale cell (0.88 Wh g1). For the calcu-
direct current is used, explaining the higher removals obtained in lation of the energy costs, we considered the average cost of energy
exp. F compared with exp. E. Table 3 shows the pH values after the in the European Union (EUROSTAT 2011). If we are only dealing
experiments. Only in experiment F a lower pH is obtained due to with organic contaminants that can be completely degraded, there
the high buffer capacity of the soil. is no need to treat and dispose the anolyte after separation from the
Fig. 4 shows the current values measured in the experiments, solids. Even adding the excavation and transport costs, this solution
using both cells. The highest current values were measured in setup is competitive when compared with the off-site incineration
A and are related to the high metal content of the tested soil. When average costs (885 V m3) and off-site landfilling costs (231 V m3)
the metals are dissolved or desorbed by the Hþ generated at the in Europe (Summersgill, 2006) and the off-site landfilling costs for
anode, the conductivity of the suspension increases. In setup B hazardous waste in the USA (327 USD m3, approximately 239 V
(Fig. 4), the current values reached a peak immediately after the m3) (Ram et al., 2013).
experiment start, when the quantity of ions in the pore solution
was higher due to the dissolution of salts associated with soil
4. Conclusions
particles. The current dropped abruptly in the first hours and sta-
bilized thereafter, with little oscillations, in all experiments. The Hþ
In summary, the new electrodialytic setup tested in this work
generated at the anode can solubilize transition metals such as Fe
allowed PCB dechlorination from contaminated soil ex situ at a
and Ni from soil, that can degrade PCB via catalytic hydro-
higher percentage, in a shorter time, with lower nZVI consumption,
dechlorination with H2 successively removing chlorine atoms from
and with the use of half of the voltage gradient when compared
PCB generating biphenyl, according to the general chemical equa-
with the traditional electrokinetic setup. In addition, there is no
tion (Wu et al., 2012):
need to treat and dispose of the anolyte. However, additional
testing with different soils, repeated application of the technique
C12H(10m) Clm þ nH2 / C12H(10mþn)Clm-n þ nHCl, m S n (7)
on the same material (also with different duration experiments),
testing of enhancement methods and further optimization and
Although this hydrodechlorination has been reported for
scale up of the process are needed to prove the versatility of the
aqueous or organic solvents, in the tested setup there are all the
electrodialytic setup.
needed conditions for it to occur. However, further research is
The results show that the soil characteristics are important and
needed to evaluate the importance of this dechlorination process,
affect the reactions between nZVI and the target contaminant,
to assess how iron (natural and manufactured) and other metals act
especially pH and carbonate content. Direct current can enhance
as catalysts.
dechlorination in this new electrodialytic setup.
Based on the preliminary results obtained in this work, a rough This work was funded by the European Regional Development
estimate of the operation cost of using the new electrodialytic setup Fund (ERDF) through COMPETE e Operational Programme for
(A) for ex situ remediation of PCB contaminated soil was made. Competitiveness Factors (OPCF), by Portuguese National Funds
Please cite this article in press as: Gomes, H.I., et al., Treatment of a suspension of PCB contaminated soil using iron nanoparticles and electric
current, Journal of Environmental Management (2015), http://dx.doi.org/10.1016/j.jenvman.2015.01.015
6 H.I. Gomes et al. / Journal of Environmental Management xxx (2015) 1e6
Please cite this article in press as: Gomes, H.I., et al., Treatment of a suspension of PCB contaminated soil using iron nanoparticles and electric
current, Journal of Environmental Management (2015), http://dx.doi.org/10.1016/j.jenvman.2015.01.015