You are on page 1of 2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Pos QTY Description


A Details of Anchor Bolts 1 1 Ipsen Sealed Quench Furnace [TQF-4(5)-ERM] A
of Loader
2 1 Loader Track
Track QUENCH OIL PUMP M12 8 3 6 Plate 200 x 150 mm; Thk. 12
CONTROL PANEL FOR S.Q.F'CE. M12 4 4 1 Unloader/Loader Track
S.Q.F'CE. [TQF-4(5)-ERM] M16 6
EQUIPMENT ANCHOR BOLTS QTY

340
L1 of Loader
(+2500) Details of Emergency Water Requirement
B 4" Water Sump 300x300 Track B
N Drain Pipe 300 Deep. TQF-4(5)-ERM EW 10 LITRES/MINUTE
(+750)
NH EQUIPMENT LEGEND FLOW RATE
(+750) 150 885 150 885 150
Auxilary Oil Tank
may be placed
suitably according L2 +60
300
to space at site. (+750) EW/W

300
(+2200)
C C
1720

300

3310

200
Pit (-160)

2300 (Pit Length)

2300 (Pit Length)


175 1
A A
Drain Slope

1500

1300
Towards Sump
1600

D D
A1
50 (+1950)

3315
1035 1035
Working Height +1105

300

200
340

340

240
E E

1105
Ground 0 W
of Unloader/Loader 2070 160
of Unloader/Loader
Track 1400 2200 (Outside to Outside) Track 2600 (Pit Width)

300
X
F 2 4 F
A-A ( 1 : 15 ) 300 300 1600
of Unloader/Loader
of Loader 1110 2300
-160 Track
2600 (Pit Width) Track
3310 100
Ground 0
1035 1035 Sump 300x300
G G
300 300 Deep.
160
300

H 190 150 100 150 100 150 190 H


ATMOSPHERE
8 LPG PROCESS L2 1/2"BSP. 20-100 mbar 2.25 M3/Hr.
MIXING PANEL
7 LPG PILOT BURNER FLAME CURTAIN L1 FURNACE 1/2"BSP. 20-100 mbar 0.22 M3/Hr.
6 AIR PNEUMATIC SYSTEM A1 FURNACE 1/2"BSP. 5-7 bar 44 M3 /Hr.

-- ATMOSPHERE From Blower in -- --


5 AIR PROCESS
MIXING PANEL C/N Panel
ATMOSPHERE
4 AMMONIA PROCESS NH 1/2"BSP. 30-150 mbar 0.7 M3 /Hr.
I Electrical Panel Connection Load for Each Equipment MIXING PANEL I
(To be connected by Customer to our Control Panel) 2 NITROGEN PURGING N
ATMOSPHERE
1/2"BSP. 30-150 mbar 5 M3 /Hr.
MIXING PANEL
230V SINGLE PHASE SUPPLY, 1 WATER COOLING W FURNACE 1-1/2"BSP. 3-5 bar 16 M3 /Hr.
TQF-4(5)-ERM PANEL WITH 415 5%V 3 PHASE 4 50~ AC THROUGH UPS.
1 120 KVA
THYRISTOR WIRE 50 ~ AC (CUSTOMER SCOPE) SL.NO. UTILITY REQD. FUNCTION LEGEND LOCATION SIZE PRESSURE FLOW/CONNECTED LOAD

SL.NO. MODEL POWER SUPPLY RATING CONTROL SUPPLY

J INCOMING POWER SUPPLY TO CONTROL PANEL SHOULD BE 4 CORE x UTILITY CHART J


120 sq.mm. ALUMINIUM CONDUCTOR, XLPE INSULATED, ARMOURED,
PVC JACKETED CABLE OR EQUIVALENT COPPER CABLE.
IP-5664
NOTE :
Sansera Engg. Pvt. Ltd. ; Manesar
1. S.Q.F'CE., ATMOSPHERE MIXING PANEL, QUENCH OIL COOLER, AND QUENCH OIL PUMP TO
BE FIXED WITH ANCHOR BOLTS AT THE TIME OF ERECTION. Zust. Aenderung nur in Inventor Datum Name
K WATER QUALITY SPECIFICATION
K
2. ANCHOR BOLTS TO BE SUPPLIED BY CUSTOMER. Datum Name Massstab Gewicht in kg

3. ITPL TO SUPPLY AND FIT PRESSURE REGULATORS IN FURNACE & ATMOSPHERE MIXING PANEL
Pit Dimension : 2300L x 2600W x -160D Gez.
Gepr.
06-09-2019 pnp Werkstoff ---------------------------
Designation
107-178 267-320 Norm.
TO FEED UTILITIES LIKE LPG, NITROGEN, AMMONIA & PNEUMATIC AIR. 6-10 15-18
Without Dosing With Dosing Foundation & Utility Details of
Without Dosing With Dosing TQF-4(5)-ERM 160 mm PIT
4. ALL PRESSURE REGULATORS MUST HAVE FILTER AT INLET WITH PRESSURE GAUGE AT OUTLET. Weitergabe sowie Vervielf ltigung dieser Zeichnung, Verwertung und Mitteilung seines
INCOMING PIPELINES MUST HAVE PRESSURE GAUGE WITH ISOLATION/SHUT OFF VALVE BY CUSTOMER. Inhalts sind verboten, soweit nicht ausdr cklich gestattet. Zuwiderhandlungen Dwg-No. Blatt Bl.Anz.

IPSEN SPECIFICATION IPSEN SPECIFICATION CONVERTED TO verpflichten zu Schadenersatz. Alle Rechte f r den Fall der Patent-,
IPLUF-785 1 2
5. PIPING FROM ATMOSPHERE MIXING PANEL TO S.Q.F'CE. BY CUSTOMER. ppm CaCO3 equivalent (Carbonate hardness) Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. Kolkata,Bhasa-743503
(dh OR German Hardness No.) Transmission and duplication of this drawing, use and communication of Ursprung ---------------------- Ersatz fuer ------------------- Ers. durch -------------------
L 1dH= 17.8 mg/L (ppm) CaCO3 L
its content are prohibited, except as expressly permitted. Infringements Allg. Toleranzen nach ISO 2768-m Projektionsmethode 1
committed to damages. All rights in the case of patent, utility model or Allg. Toleranzen fuer Schweisskonstruktion nach ISO 13920-BF ISO 5456-2
industrial design registration is reserved. Oberflaechenbeschaffenheit nach ISO 1302 VERTRAULICH nach ISO 16016 A1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A A

B B

00
23

0
16
26
00

C C
0
20
41
5

00
13 0
10

88 15
D 5 0 D

88
5

E E

F F

G G

H H
W(1:5)
X(1:5)

I I
340 340

100 60 230
Ground 0 100 (190) 100

5 50 Ground 0 50 5

J J
160

160

IP-5664
Sansera Engg. Pvt. Ltd. ; Manesar Zust. Aenderung nur in Inventor Datum Name
K Datum Name Massstab Gewicht in kg
K
Gez. 06-09-2019 pnp Werkstoff ---------------------------
Gepr. Designation
Norm.
Foundation & Utility Details of
Weitergabe sowie Vervielf ltigung dieser Zeichnung, Verwertung und Mitteilung seines
TQF-4(5)-ERM 160 mm PIT
Inhalts sind verboten, soweit nicht ausdr cklich gestattet. Zuwiderhandlungen Dwg-No. Blatt Bl.Anz.
verpflichten zu Schadenersatz. Alle Rechte f r den Fall der Patent-,
Gebrauchsmuster- oder Geschmacksmustereintragung vorbehalten. Kolkata,Bhasa-743503 IPLUF-785 2 2
Transmission and duplication of this drawing, use and communication of Ursprung ---------------------- Ersatz fuer ------------------- Ers. durch -------------------
L its content are prohibited, except as expressly permitted. Infringements Allg. Toleranzen nach ISO 2768-m L
Projektionsmethode 1
committed to damages. All rights in the case of patent, utility model or Allg. Toleranzen fuer Schweisskonstruktion nach ISO 13920-BF ISO 5456-2
industrial design registration is reserved. Oberflaechenbeschaffenheit nach ISO 1302 VERTRAULICH nach ISO 16016 A1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

You might also like