You are on page 1of 8

CONSULTANCY SERVICES FOR FEASIBILITY STUDY AND DETAILED DESIGN FOR METALLED ROAD FROM MOTORWAY INTERCHANGE KATHA

LILLA UPTO MIANWALI VIA NALI, KUND, JABBI, WARCHA,


GOLEWALI, CHIDDRU, MUSAKHEL AND MIANWALI 0+000 KM - 40+000 KM (40 KM)

ENGINEER'S COST ESTIMATE

BILL NO. 4D: STRUCTURES (BRIDGES)

Pay Item No. Item Description Unit 30mtr Quantity Rate (Rs.) Amount (Rs.)
107a Structural excavation in common material. C.M - 0.00 360.92 0
107d Granular backfill C.M 434.98 457.00 1,506.40 688,425
Cast-in-place concrete piles dia as per drawings (excluding
reinforcement).
a Test piles dia as per drawings (excluding reinforcement)
407d3 Cast in Place concrete piles upto 1.1-1.5 M dia in Normal Soil (Boring only) M 11.00 12.00 12,163.40 145,961

401a3(i) Concrete Class A3 in pile C.M 12.43 13.00 10,679.13 138,829


b working piles dia as per drawings (excluding reinforcement.)
407d3 Cast in Place concrete piles upto 1.1-1.5 M dia in Normal Soil (Boring only) M 88.00 92.00 12,163.40 1,119,033

401a3(i) Concrete class A3 in piles C.M 99.44 104.00 10,679.13 1,110,630


401a1ii Concrete Class A1on ground in (for unreinforced structures) C.M 8.17 9.00 10,845.92 97,613
401a3ii Concrete Class A3 on ground (Approach slab,Barrier.Railling) C.M 47.89 50.00 11,539.18 576,959
401a3iii Concrete Class A3 Elevated (Columns,Piers,Abutment,wing C.M 261.40 274.00 11,967.02 3,278,963
walls,Diaphrams,Concrete Pads,Deck slabs,Back wall,shear keys,Retaining
wall)
401gv Precast Concrete Class D2 (Girders) C.M 126.65 133.00 15,748.35 2,094,531
401f Lean concrete C.M 15.61 16.00 5,906.03 94,496
404b Reinforcement as per AASHTO M31.Grade 60. Ton 89.22 94.00 115,897.23 10,894,340
404h Reinforcement as per ASTM-A-36 Structural Shape (for bearing steel/sole Ton 0.35 0.00 141,017.31 0
plats)
404hi Reinforcement as per ASTM-A-500 Structural tubes (for steel railing) Ton 0.00 190,000.00 0
405a Pre-stressing wiring strands 3/8"-1/2" DIA complete in all respects Ton 6.13 6.00 224,439.99 1,346,640
405b Launching of girders Ton 316.63 332.00 1,311.50 435,418
406aii Approved Filler Board with poly sulphide sealant as per drawings & S.M 8.71 9.00 2,932.84 26,396
specification
406ei Elastomeric Bearing Pads (According to size & thickness)-USA/EU make Cu.cm 97,650.00 102,533.00 6.59 675,692

406i Neoprene Bearing Strip thickness s per drawings & specification S.M 7.26 8.00 1,962.36 15,699
407m Pile Load Test upto 900 TON Each 1.00 1.00 1,350,000.00 1,350,000
407n Pile Load Test upto 1200 TON Each 0.00 1,800,000.00 0
407p Pile Integrity test (sonic integrity) on all working piles Each 8.00 8.00 3,000.00 24,000
407qi Cross Hole Sonic Logging Test including G.I.pipes and grouting complete in Each 1.00 1.00 143,000.00 143,000
all respect as per drawings and specification (on test piles only)

406cv Expansion joint Monobolic type 65mm Movement (USA/EU Make) M 25.54 27.00 53,623.93 1,447,846
509c Rip Rap Class C C.M - 0.00 2,014.39 0
509e Grouted Rip Rap Class B C.M 256.80 270.00 4,730.47 1,277,227
509h Filter Layer of Granular Material C.M 102.72 108.00 1,668.47 180,195
SP-614a G.I. drain pipes (100mm diameter ) as per drawings M 0.00 1,948.44 0
SP-614b G.I. drain pipes (75mm diameter ) as per drawings M 4.80 5.00 1,500.00 7,500
Flood Protection Wall
401f Lean concrete C.M 17.05 18.00 5,906.03 106,309
507a Steel Wire Mesh For Gabion Kg 3,262.81 3,426.00 165.47 566,900
507b Rock Fill in Gabion C.M 701.68 737.00 1,144.36 843,393
TOTAL BILL NO. 4D: STRUCTURES (BRIDGES) (RS) 28,685,994
CONSULTANCY SERVICES FOR FEASIBILITY STUDY AND DETAILED DESIGN FOR METALLED ROAD FROM MOTORWAY INTERCHANGE KATHA LILLA UPTO MIANWALI VIA NALI, KUND, JABBI, WARCHA,
GOLEWALI, CHIDDRU, MUSAKHEL AND MIANWALI 0+000 KM - 40+000 KM (40 KM)

ENGINEER'S COST ESTIMATE

BILL NO. 4D: STRUCTURES (BRIDGES)

Pay Item No. Item Description Unit 20 mtr Quantity Rate (Rs.) Amount (Rs.)
107a Structural excavation in common material. C.M 181.50 191.00 360.92 68,936
107d Granular backfill C.M 434.98 457.00 1,506.40 688,425
Cast-in-place concrete piles dia as per drawings (excluding
reinforcement).
a Test piles dia as per drawings (excluding reinforcement)
407d3 Cast in Place concrete piles upto 1.1-1.5 M dia in Normal Soil (Boring only) M 7.20 8.00 12,163.40 97,307

401a3(i) Concrete Class A3 in pile C.M 8.14 9.00 10,679.13 96,112


b working piles dia as per drawings (excluding reinforcement.)
407d3 Cast in Place concrete piles upto 1.1-1.5 M dia in Normal Soil (Boring only) M 86.40 91.00 12,163.40 1,106,869

401a3(i) Concrete class A3 in piles C.M 97.63 103.00 10,679.13 1,099,950


401a1ii Concrete Class A1on ground in (for unreinforced structures) C.M 8.17 9.00 10,845.92 97,613
401a3ii Concrete Class A3 on ground (Approach slab,Barrier.Railling) C.M 242.58 255.00 11,539.18 2,942,491
401a3iii Concrete Class A3 Elevated (Columns,Piers,Abutment,wing C.M 418.60 440.00 11,967.02 5,265,489
walls,Diaphrams,Concrete Pads,Deck slabs,Back wall,shear keys,Retaining
wall)
401gv Precast Concrete Class D2 (Girders) C.M 78.21 82.00 15,748.35 1,291,365
401f Lean concrete C.M 26.61 28.00 5,906.03 165,369
404b Reinforcement as per AASHTO M31.Grade 60. Ton 152.34 160.00 115,897.23 18,543,557
404h Reinforcement as per ASTM-A-36 Structural Shape (for bearing steel/sole Ton 0.35 0.00 141,017.31 0
plats)
404hi Reinforcement as per ASTM-A-500 Structural tubes (for steel railing) Ton 0.00 190,000.00 0
405a Pre-stressing wiring strands 3/8"-1/2" DIA complete in all respects Ton 4.15 4.00 224,439.99 897,760
405b Launching of girders Ton 195.53 205.00 1,311.50 268,858
406aii Approved Filler Board with poly sulphide sealant as per drawings & S.M 8.71 9.00 2,932.84 26,396
specification
406ei Elastomeric Bearing Pads (According to size & thickness)-USA/EU make Cu.cm 97,650.00 102,533.00 6.59 675,692

406i Neoprene Bearing Strip thickness s per drawings & specification S.M 7.26 8.00 1,962.36 15,699
407m Pile Load Test upto 900 TON Each 1.00 1.00 1,350,000.00 1,350,000
407n Pile Load Test upto 1200 TON Each 0.00 1,800,000.00 0
407p Pile Integrity test (sonic integrity) on all working piles Each 12.00 12.00 3,000.00 36,000
407qi Cross Hole Sonic Logging Test including G.I.pipes and grouting complete in Each 1.00 1.00 143,000.00 143,000
all respect as per drawings and specification (on test piles only)

406cv Expansion joint Monobolic type 65mm Movement (USA/EU Make) M 25.54 27.00 53,623.93 1,447,846
509c Rip Rap Class C C.M - 0.00 2,014.39 0
509e Grouted Rip Rap Class B C.M - 0.00 4,730.47 0
509h Filter Layer of Granular Material C.M - 0.00 1,668.47 0
SP-614a G.I. drain pipes (100mm diameter ) as per drawings M 0.00 1,948.44 0
SP-614b G.I. drain pipes (75mm diameter ) as per drawings M 3.20 3.00 1,500.00 4,500
Flood Protection Wall
401f Lean concrete C.M 5,906.03 6,201.00 5,906.03 36,623,292
507a Steel Wire Mesh For Gabion Kg 165.47 174.00 165.47 28,792
507b Rock Fill in Gabion C.M 1,144.36 1,202.00 1,144.36 1,375,521
TOTAL BILL NO. 4D: STRUCTURES (BRIDGES) (RS) 76,599,455
BRIDGE NO

MEASUREMENT SHEET

CHAINAGE 5+800 METER 20.00

BILL NO.4
Steel
Sr. No. Pay Item No. Item Description Unit NOS L B H/D QTY
Concrete Kg/cum Ton
107a Structural Excavation in Common Material. CM
Retaining wall footing 4 4 3.9 0.8
2 12.1 5 1.5 181.5
181.50

TOTAL

107d Granular Backfill along Abutments CM

4 4.00 1.40 5.00


Retaining wall

2 13.80 4.00 3.94 434.98

434.98

107e Common Backfill in Structures CM -

407g Test Piles of 1500 mm. Dia. Including Boring and


Concrete Class A3 Excluding Reinforcement.

407d3 Boring (Dia 1.5 M) only in Normal Soil


M 1 7.20 7.20
407d3 Boring (Dia 1.5 M) only in Normal Soil
M 0 0.00 0.00

401a3ii. Concrete class A3 in Piles


CM 1 7.20 A= 1.130 8.14 8.14 200.00 1.63

401a3ii. Concrete class A3 in Piles


CM 0.00 A= - - 200.00 0.00

8.14

407d Cast-in-place Concrete Piles (Diameter) including


Concrete Class A3 but excluding Reinforcement.

407d3 Boring (Dia 1.5 M) only in Normal Soil


M 12 7.200 86.40
407d3 Boring (dia 1.5 M) only in Normal Soil
M 0 7.20 -

401a3ii. Concrete class A3 in Piles


CM 12 7.20 A= 1.130 97.63 97.63 200.00 19.53
401a3ii. Concrete class A3 in Piles
CM 0 0.00 A= 1.77 - - 200.00 0.00

97.63

401a3ii Concrete Class A3 in


i) Approach Slab
CM 2.00 12.10 4.00 0.30 29.04 29.04 150.00 4.36
ii) Barrier 2.00 28.00 A= 0.248 13.89 150.00
CM 13.89 2.08
iii) Concrete Railing - 28.00 0.20 0.700
CM - - 150.00 0.00
iv) Walk Way Toe -

42.93

401a1ii Concrete Class A1 in


ii) Sleeper slab
CM 2.00 12.10 0.38 0.30 2.72 8.17 180.00 1.47

2.00 12.10 0.38 0.60 5.45

8.17

401g Pre-cast Concrete A1 in Panels


CM 0 30.00 0.65 0.08 0.00

401a3iii Concrete Class A3 in

Back wall
CM 2 13.800 0.40 3.800 41.95 45.68 150.00 6.85
Backwall tappered
CM 2 13.800 0.30 0.450 3.73 0.00
Side wall/curtain wall/Champher abutment transom
CM 4 1.750 0.20 0.30 0.42 0.42 150.00 0.06
Side wall/curtain wall/Champher pier transom
CM 0 1.700 0.20 0.30 0.00 0.00 150.00 0.00
Small shear keys Abutment
CM 8 1.750 0.30 0.60 2.52 2.52 150.00 0.38
Large shera keys abutment
CM 0.00 0.00 150.00 0.00
Small shear keys piers
CM 0 1.750 0.30 0.60 0.00 0.00 150.00 0.00
Large shear keys piers
CM 0.00 0.00 150.00 0.00
Concrete pads
CM 10 0.650 0.55 0.06 0.22 0.22 150.00 0.03
Wing walls
CM 4 2 0.500 3.80 15.20 26.40 150.00 3.96

4 2 0.500 2.80 11.20 150.00 0.00

End Diaphram CM 8 1.921 0.250 1.83 7.01 7.01 200.00 1.40

Intermediate Diaphgragm CM 4 1.921 0.250 1.83 3.51 3.51 200.00 0.70


Abutment Transom
CM 2.00 13.67 1.85 1.50 75.89 75.89 122.00 9.26
Pier Transom
CM - 13.80 2.10 1.80 0.00 0.00 122.00 0.00

- 13.73 2.10 1.80 0.00 0.00 122.00 0.00

- 13.82 2.10 1.80 0.00 0.00 122.00 0.00

- 13.88 2.10 1.80 0.00 0.00 122.00 0.00


Deck Slab Elevated CM
1.00 20.00 12.10 0.225 54.45 54.45 200.00 10.89
CM
- 30.19 13.80 0.225 0.00 0.00 200.00 0.00
CM
- 29.45 13.80 0.225 0.00 0.00 200.00 0.00
CM
- 30.20 13.80 0.225 0.00 0.00 200.00 0.00
CM
- 30.30 13.80 0.225 0.00 0.00 200.00 0.00

Piers Columns/shafts
CM 12.00 2.00 A 1.13 27.12 27.12 180.00 4.88

Retaining wall
CM 2.00 12.10 0.85 8.50 174.85 175.39 200.00 35.08

2.00 12.10 0.15 0.15 0.54

TOTAL 418.60

401a3ii Concrete Class A3 Undergrund

Retaining wall footing CM 2 12.10 5.50 1.50 199.65 199.65 200.00 39.93

401giv PRECAST CONCRETE CLASS D2 CM

Exterior Girder (20m) CM 2 vol= 15.60 31.20 31.20 126 3.93

Interior Girder (20 m) CM 3 15.67 47.01 47.01 126 5.92

78.21

401f Lean Concrete

Retaining wall footing


CM 2 12.10 5.50 0.10 11.00
BRIDGE NO

MEASUREMENT SHEET

CHAINAGE 5+800 METER 20.00

BILL NO.4
Steel
Sr. No. Pay Item No. Item Description Unit NOS L B H/D QTY
Concrete Kg/cum Ton

Under Approach Slab CM 2 12.10 4.30 0.150 15.61

26.61

401a3iv Difference of Cost for Using SRC Cement in place of


OPC Cement for Concrete Class A3 Under Ground
(Piles) works in addition to BOQ Rates. TON 8 BAGS/CUM -
BRIDGE NO

MEASUREMENT SHEET

CHAINAGE 5+800 METER 20.00

BILL NO.4
Steel
Sr. No. Pay Item No. Item Description Unit NOS L B H/D QTY
Concrete Kg/cum Ton
404b Reinforcement in including Piles as per AASHTO
M31.

404b. Grade 60 152.34


TONS 152.34
TOTAL REINFORCEMENT 152.34

404h Reinforcement as per ASTM-A-36 Structural Shape

Steel bearing plate v= 0.0045 0.35


Ton 10.00 7850 kg/cum
for end diaphram 12 mm thick plate 200x200x12 mm 0.00 v= 0.0005 -
Ton 7850 kg/cum
intermediate diaphragm 12 mm thick plate 110x180x12 0.00 0.0005 -
Ton v=
mm
Angle Section for walk way 50x50x5 mm 3.7300 -
0.00 0.625 kg/m
0.35

405a PRE-STRESSING WIRE STRAND 3/8"-1/2" DIA


COMPLETE IN ALL RESPECT KG/M
TONS
25 255.00 21.00 0.775 4,150.13

4,150.13 4.15

405b LAUNCHING of GIRDERS


TONS 78.21 2.50 ton/cum 195.53

406ai Approved Filler Board 20mm with poly sulphide


sealent as per drawings SM 2.00 12.10 0.36 8.71

Elastomeric bearing pads (350x450x62 mm) with 3


406e nos. 3 mm thick steel plates and enclosed in rubber cu.cm 10 35.00 45.00 6.20 97,650.00
cover of 3 mm thick.

406i Neoprene Bearing Strip 10mm thick as per drawing SM 2 12.10 0.30 7.26 7.26

407n Confirmatory Boring


M 0 40.00 0.00

Proof Load Test to 1.5 times the design load


407j EACH 0 0
(Test load 270Ton) ABUT WORK PILE
0
Proof Load Test to 1.5 times the design load
407j EACH 0 0
(Test load 450 Ton) PIER WORK PILE

Pile Load Test to 2.5 times the design load


407k EACH 1 1.00
(Test load 400Ton) ABUT TEST PILE

Pile Load Test to 2.5 times the design load


407k EACH 0 0
(Test load 750Ton) PIER TEST PILE

407p PILE INTEGRITY TEST ON ALL PILES NO 12 12.00

407qi Cross Hole Sonic Logging Test (on test piles only)
NO 1 1.00

Manufactured Trade Marks expansion joints (Finger


SP-414a M 2 12.77 25.54
Type) for roadway 25 mm movement

Manufactured Trade Marks expansion joints (Finger


SP-414a M 0 13.00 0.00
Type) for roadway 50 mm movement

509e Grouted Rip Rap Class B CM 1 32.10 8.00 0.50

1 32.10 8.00 0.50

0.00

509c Rip Rap Class C


CM 1 32.10 3.00 0.50

1 32.10 1.13 0.75

1 32.10 3.00 0.50

1 32.10 1.13 0.75

0.00

509h Filter Layer of Granular Material


CM 1 32.10 8.00 0.20
CM 1 32.10 8.00 0.20

0.00

SP-614a G.I. drain pipes for drainage including all fixtures,


bends and grates (75 mm diameter ) M 2 20.00 5m c/c 0.40 3.20

SP-616e PVC pipe 25 mm DIA along deck slab for dowels


filled with soft bitumen drawings with bitument filled M 1 12.10 150 mm c/c 0.280 22.59
as per
215 Providing & Placing Geotextile (500gram/sqm or
equivalent) S.M 4 4.00 0.20
BRIDGE NO

MEASUREMENT SHEET

CHAINAGE 5+800 METER 30.00

BILL NO.4
Steel
Sr. No. Pay Item No. Item Description Unit NOS L B H/D QTY
Concrete Kg/cum Ton
107a Structural Excavation in Common Material. CM
Retaining wall footing 4 4 3.9 0.8
0 13.8 2.3 1.8 0
-

TOTAL

107d Granular Backfill along Abutments CM

4 4.00 1.40 5.00


Retaining wall

2 13.80 4.00 3.94 434.98

434.98

107e Common Backfill in Structures CM -

407g Test Piles of 1500 mm. Dia. Including Boring and


Concrete Class A3 Excluding Reinforcement.

407d3 Boring (Dia 1.5 M) only in Normal Soil


M 1 11.00 11.00
407d3 Boring (Dia 1.5 M) only in Normal Soil
M 0 0.00 0.00

401a3ii. Concrete class A3 in Piles


CM 1 11.00 A= 1.130 12.43 12.43 200.00 2.49

401a3ii. Concrete class A3 in Piles


CM 0.00 A= - - 200.00 0.00

12.43

407d Cast-in-place Concrete Piles (Diameter) including


Concrete Class A3 but excluding Reinforcement.

407d3 Boring (Dia 1.5 M) only in Normal Soil


M 8 11.000 88.00
407d3 Boring (dia 1.5 M) only in Normal Soil
M 0 11.00 -

401a3ii. Concrete class A3 in Piles


CM 8 11.00 A= 1.130 99.44 99.44 200.00 19.89
401a3ii. Concrete class A3 in Piles
CM 0 0.00 A= 1.77 - - 200.00 0.00

99.44

401a3ii Concrete Class A3 in


i) Approach Slab
CM 2.00 12.10 4.00 0.30 29.04 29.04 150.00 4.36
ii) Barrier 2.00 38.00 A= 0.248 18.85 150.00
CM 18.85 2.83
iii) Concrete Railing - 38.00 0.20 0.700
CM - - 150.00 0.00
iv) Walk Way Toe -

47.89

401a1ii Concrete Class A1 in


ii) Sleeper slab
CM 2.00 12.10 0.38 0.30 2.72 8.17 180.00 1.47

2.00 12.10 0.38 0.60 5.45

8.17

401g Pre-cast Concrete A1 in Panels


CM 0 30.00 0.65 0.08 0.00

401a3iii Concrete Class A3 in

Back wall
CM 2 13.800 0.40 3.800 41.95 45.68 150.00 6.85
Backwall tappered
CM 2 13.800 0.30 0.450 3.73 0.00
Side wall/curtain wall/Champher abutment transom
CM 4 1.750 0.20 0.30 0.42 0.42 150.00 0.06
Side wall/curtain wall/Champher pier transom
CM 0 1.700 0.20 0.30 0.00 0.00 150.00 0.00
Small shear keys Abutment
CM 8 1.750 0.30 0.60 2.52 2.52 150.00 0.38
Large shera keys abutment
CM 0.00 0.00 150.00 0.00
Small shear keys piers
CM 0 1.750 0.30 0.60 0.00 0.00 150.00 0.00
Large shear keys piers
CM 0.00 0.00 150.00 0.00
Concrete pads
CM 10 0.650 0.55 0.06 0.22 0.22 150.00 0.03
Wing walls
CM 4 2 0.500 3.80 15.20 26.40 150.00 3.96

4 2 0.500 2.80 11.20 150.00 0.00

End Diaphram CM 8 1.921 0.250 1.83 7.01 7.01 200.00 1.40

Intermediate Diaphgragm CM 4 1.921 0.250 1.83 3.51 3.51 200.00 0.70


Abutment Transom
CM 2.00 13.67 1.85 1.50 75.89 75.89 122.00 9.26
Pier Transom
CM - 13.80 2.10 1.80 0.00 0.00 122.00 0.00

- 13.73 2.10 1.80 0.00 0.00 122.00 0.00

- 13.82 2.10 1.80 0.00 0.00 122.00 0.00

- 13.88 2.10 1.80 0.00 0.00 122.00 0.00


Deck Slab Elevated CM
1.00 30.00 12.10 0.225 81.68 81.68 200.00 16.34
CM
- 30.19 13.80 0.225 0.00 0.00 200.00 0.00
CM
- 29.45 13.80 0.225 0.00 0.00 200.00 0.00
CM
- 30.20 13.80 0.225 0.00 0.00 200.00 0.00
CM
- 30.30 13.80 0.225 0.00 0.00 200.00 0.00

Piers Columns/shafts
CM 8.00 2.00 A 1.13 18.08 18.08 180.00 3.25

Retaining wall
CM 4.00 4.00 0.50 5.00 0.00 200.00 0.00

4.00 4.00 0.15 0.15

TOTAL 261.40

401a3ii Concrete Class A3 Undergrund

Retaining wall footing CM 4 4.00 2.90 0.50 0.00 200.00 0.00

401giv PRECAST CONCRETE CLASS D2 CM

Exterior Girder (30m) CM 2 vol= 25.27 50.54 50.54 126 6.37

Interior Girder (30 m) CM 3 25.37 76.11 76.11 126 9.59

126.65

401f Lean Concrete

Retaining wall footing


CM 4 4.00 3.10 0.10
BRIDGE NO

MEASUREMENT SHEET

CHAINAGE 5+800 METER 30.00

BILL NO.4
Steel
Sr. No. Pay Item No. Item Description Unit NOS L B H/D QTY
Concrete Kg/cum Ton

Under Approach Slab CM 2 12.10 4.30 0.150 15.61

15.61

401a3iv Difference of Cost for Using SRC Cement in place of


OPC Cement for Concrete Class A3 Under Ground
(Piles) works in addition to BOQ Rates. TON 8 BAGS/CUM -
BRIDGE NO

MEASUREMENT SHEET

CHAINAGE 5+800 METER 30.00

BILL NO.4
Steel
Sr. No. Pay Item No. Item Description Unit NOS L B H/D QTY
Concrete Kg/cum Ton
404b Reinforcement in including Piles as per AASHTO
M31.

404b. Grade 60 89.22


TONS 89.22
TOTAL REINFORCEMENT 89.22

404h Reinforcement as per ASTM-A-36 Structural Shape

Steel bearing plate v= 0.0045 0.35


Ton 10.00 7850 kg/cum
for end diaphram 12 mm thick plate 200x200x12 mm 0.00 v= 0.0005 -
Ton 7850 kg/cum
intermediate diaphragm 12 mm thick plate 110x180x12 0.00 0.0005 -
Ton v=
mm
Angle Section for walk way 50x50x5 mm 3.7300 -
0.00 0.625 kg/m
0.35

405a PRE-STRESSING WIRE STRAND 3/8"-1/2" DIA


COMPLETE IN ALL RESPECT KG/M
TONS
25 255.00 31.00 0.775 6,126.38

6,126.38 6.13

405b LAUNCHING of GIRDERS


TONS 126.65 2.50 ton/cum 316.63

406ai Approved Filler Board 20mm with poly sulphide


sealent as per drawings SM 2.00 12.10 0.36 8.71

Elastomeric bearing pads (350x450x62 mm) with 3


406e nos. 3 mm thick steel plates and enclosed in rubber cu.cm 10 35.00 45.00 6.20 97,650.00
cover of 3 mm thick.

406i Neoprene Bearing Strip 10mm thick as per drawing SM 2 12.10 0.30 7.26 7.26

407n Confirmatory Boring


M 0 40.00 0.00

Proof Load Test to 1.5 times the design load


407j EACH 0 0
(Test load 270Ton) ABUT WORK PILE
0
Proof Load Test to 1.5 times the design load
407j EACH 0 0
(Test load 450 Ton) PIER WORK PILE

Pile Load Test to 2.5 times the design load


407k EACH 1 1.00
(Test load 400Ton) ABUT TEST PILE

Pile Load Test to 2.5 times the design load


407k EACH 0 0
(Test load 750Ton) PIER TEST PILE

407p PILE INTEGRITY TEST ON ALL PILES NO 8 8.00

407qi Cross Hole Sonic Logging Test (on test piles only)
NO 1 1.00

Manufactured Trade Marks expansion joints (Finger


SP-414a M 2 12.77 25.54
Type) for roadway 25 mm movement

Manufactured Trade Marks expansion joints (Finger


SP-414a M 0 13.00 0.00
Type) for roadway 50 mm movement

509e Grouted Rip Rap Class B CM 1 32.10 8.00 0.50 128.40

1 32.10 8.00 0.50 128.40

256.80

509c Rip Rap Class C


CM 1 32.10 3.00 0.50

1 32.10 1.13 0.75

1 32.10 3.00 0.50

1 32.10 1.13 0.75

0.00

509h Filter Layer of Granular Material


CM 1 32.10 8.00 0.20 51.36
CM 1 32.10 8.00 0.20 51.36

102.72

SP-614a G.I. drain pipes for drainage including all fixtures,


bends and grates (75 mm diameter ) M 2 30.00 5m c/c 0.40 4.80

SP-616e PVC pipe 25 mm DIA along deck slab for dowels


filled with soft bitumen drawings with bitument filled M 1 12.10 150 mm c/c 0.280 22.59
as per
215 Providing & Placing Geotextile (500gram/sqm or
equivalent) S.M 4 4.00 0.20

You might also like