You are on page 1of 4

Mobile Fuel Filtration 1

Dual Spin-on Series

75/B32009 75/B32016

The Racor Dual Spin-on Series provides twice bowls. The clear bowls used with these filters
the filtering capacity in one compact and robust will not discolor from alcohol, additives, or UV
package. A shut-off valve located in the mounting light and have a leak-proof, positive seal and
head can switch to the clean filter so that the self-venting drain for easy servicing. Water and
dirty filter may be serviced (servicing filters is not contamination levels can be seen easily at a
possible while engine is running).
glance. When the on-line filter gets dirty, switch
to the clean one. Servicing filters is not possible
These assemblies feature Aquabloc® II
while engine is running.
replaceable filter elements that stop water,
remove solid contamination, and are available
in 2, 10 and 30 micron. Filtration needs should Optional accessories may include:
be based on application, fuel quality, operating Fuel heaters, water detection kits, hoses,
climates, and maintenance schedules. Also fittings, and more. See Accessories section for
included are spin-on contaminant collection more information.

Parker Hannifin Corporation


Racor Division, PO Box 3208
Modesto, CA 95354 USA
Phone: 800.344.3286
Fax: 209.529.3278
E-mail: racor@parker.com
www.parker.com/racor
Mobile Fuel Filtration
Dual Spin-on Series

Specifications 75/B32009 75/B32016


Maximum Flow Rate:
(one filter on-line) 60 GPH (227 LPH) 20 GPH (75 LPH)
(two filters online) 120 GPH (454 LPH) 40 GPH (151 LPH)
Port Size (UNF JIC)1 7/8”-14 3/4”-16
Height 12.4 in. (31.5 cm) 10.3 in. (26.2 cm)
Width 8.4 in. (21.3 cm) 7.6 in. (19.3 cm)
Depth 5.3 in. (13.5 cm) 4.9 in. (12.4 cm)
Center Threads 16mm X 1.5 16mm X 1.5
Solids Capacity:
(with one filter) 13.7 oz. (388 g) 6.4 oz. (182 g)
(with two filters) 27.4 oz. (777 g) 12.8 oz. (363 g)
Available Options:
(water sensor) Yes Yes
(heater) Yes Yes
Operating Temperature -40o to +255oF (-40o to +124oC)
1
Units are standard with M18 X 1.5 (ISO9974-1) O-ring face seal fuel ports. The 75/B32016 includes two
adapter fittings to ¾”-16 UNF JIC and the 75/B32009 includes two adapter fittings to 7/8”-14 UNF JIC.

The Selection Valve


BOTH ON
LEFT ON RIGHT ON

Do not service filters with engine on.

134
Technical Support:
800.344.3286 ext. 7555
racortech@parker.com
Mobile Fuel Filtration 1
Dual Spin-on Series
How to Order
75/B32009 M -10

Specify a micron rating:


Select an assembly by flow rate:
Specify M for a metal bowl.1 -2 for 2 micron,
75/B32016: 40 GPH (151 LPH)
(omit if not desired) -10 for 10 micron, or
75/B32009: 120 GPH (454 LPH)
-30 for 30 micron.
1
Use metal bowls on gasoline applications.

Replacement Elements
Model 2 micron (Final) 10 micron (Secondary) 30 micron* (Primary)

75/B32016 S3216S S3216T S3216P


75/B32009 S3209S S3209T S3209P
* A secondary/final filter is required downstream.

Mounting Information

Outlet

1.38 in.
(3.5 cm)
Inlet
Vent Vent
1.77 in.
(4.5 cm)
0.51 diameter
4 places

1.08 in. 1.55 in.


(2.7 cm) (3.9 cm)

3.71 in.
(9.4 cm)

135
Technical Support:
800.344.3286 ext. 7555
racortech@parker.com
Mobile Fuel Filtration
Dual Spin-on Series

Replacement Parts
75/B32009 and 75/B32016
Part Number Description 1
1. 30628 Dual Filter Head

2. RK10503 Element Gasket Kit

3. See Replacement Element Chart 2

4. RK300761 Bowl O-ring Kit


RK10012 2
Bowl O-ring Kit

5. Replacement Bowl Kits (includes bowl, #’s 4 to 7)


RK300511 Clear Bowl Kit 3
RK304731 Metal Bowl Kit (no probe port)

RK102152 Clear Bowl Kit


RK10109 2
Metal Bowl Kit (no probe port)
4
6. RK30476 Drain Valve Kit

7. RK20126 1/2” SAE Plug with O-ring


5
Additional Parts (not shown)
308371 Adapter Fitting
(7/8”-14 UNF JIC) 6
309452 Adapter Fitting
7
(3/4”-16 UNF JIC)

Note:
1
For 75/B32009 assembly.
2
For 75/B32016 assembly.

136