Operation Manual for  

Production Logging Tool 

 
By Rahman Rezky 

Email: rahman.rezkyitb@gmail.com 

Cellphone number: 008615229039723; 0062811712953 

Page | 0  
 
 
 
 

I. Tool Power 

*Required Voltage for PLT: 

+35 V of each tool. To determine how many given voltage should be sent from the warrior panel, you 
may  connect  the  tool  string  and  cable  head  through  jumper  cable.  Use  voltmeter  to  measure  voltage 
different between tool and ground. Increase voltage power on the warrior panel until voltage different 
between tool string and ground reaches +35V. Take note at the given voltage read on warrior panel. 

*Required Current for PLT: 

1. 3 Parameters Tools (BWCG=WTC, CCL, GR)  : 80mA 
2. BTP (Temperature and Pressure Tool    : 30‐35 mA 
3. BD (FDT)          : 40‐48 mA 
4. BH (CWH)          : 30 mA 
5. BF (Flowmeter)         : 45 mA 
6. BQF (Fullbore)          : 54‐58 mA 
7. EMDS            : 100 mA 
8. Multifinger Caliper: 
a. 24 arms         : 28 mA 
b. 40 arms         : 35‐40 mA 
c. 56 arms         : 35‐40 mA 

Additional Information: 

WAS File: 

 MUXBV2.WAS  (location:  folder  Warrior/Bin32).  Make  sure  that  you  set  Manual  Threshold=1. 
That means you will adjust the gamma ray threshold manually from warrior software. 
 Make sure that frame rate information in MUXBV2.WAS is correct according to the standard of 
new  telemetry  system.  New  telemetry  system  uses  62,500  µs/cps.  Put  this  frame  rate 
information in the text: 

[1] 

Command=        MUXB 

InputChannel=   8 

HoldingChannel= 0 

Threshold=      60 

Version=  2 

Page | 1  
 
 
 
FrameRate= 62500 

UseManualThresh= 1 

II. Recommended Tool String Order (Top to Bottom) 
a. 3 Parameters Tool (WTC, CCL, GR) 
b. Inline Centralizer  
c. CWH (Capacitance Water Holdup) 
d. FDT (Fluid Density Tool) 
e. T/P 
f. Quartz Pressure 
g. FBS (Full Bore Spinner) 

Additional note (recommendation): 

If you want to add Inline Spinner then you may install it between Quartz Pressure and FBS. 

 
III. Operation 

Operation Manual: 

1. Click Acquisition on warrior folder. 
2. Choose the correct service table. In the warrior logging system panel, click Service>XIPE PIT or 
XIPE PIT QUARTZ for PLT with quartz pressure. 
3. Choose the correct tools string. If you want to change the tool serial number then right click on 
the  tool>change>choose  the  correct  tool  serial  number.  Don’t  forget  to  click  ‘save’  after  you 
finish it.  
4. Open power control panel. Click action>power control. Click ‘Keep this box’. 
5. Open Sensors panel (at Warrior Logging System, click monitor>sensors. 
6. Open Outputs panel (at Warrior Logging System, click monitor>outputs. 
7. Open Device:SDSDSP panel (at Warrior Logging System, click monitor>device>dsp. 
8. Power  up  the  tool.  Switch  to  Positive  current  (on  warrior  panel).  Increase  voltage  on  warrior 
panel to reach *Required Voltage (monitor voltage at cable head from TVOLT at outputs panel). 
Current displayed on warrior panel should be the amount of requirement current for each tool 
(as  mentioned  on  *Required  Current).  See  further  explanation  about  required  voltage  and 
required current on page 1. 
9. Adjust Signal Gain, Quality, and Frequency: 
 
 
 

Page | 2  
 
 
 
Fine Adjustment: 
On Panel Controls adjust aux gain. 
Recommended Gain: (for Iraqi Truck) 
16 
 
Coarse Adjustment: 
Click edit>device configuration>SDSTIP>adjust gain, quality, frequency and filter.  
Recommended Gain, Quality, and Frequency: (for Iraqi Truck) 
Gain    : 0.04 
Quality    : 0.50 
Frequency  : 1,000 
Filter    : High Pass 
 
10. Adjust Signal threshold on Tel Threshold panel. Signal should be stable. Try to adjust SDSTIP and 
Control Panels so you can have as minimum noise as possible and adjust the threshold so you 
will  not  lose  any  good  signals.  Slide  down  and  up  the  red  line  and  blue  line.  See  illustration 
below: 
 

 
11. Monitor Device: SDSDSP.  
a. Error value must be stable and not changing. It is recommended for you to take note of 
the error value before you start the job. So then you can compare it with the error value 

Page | 3  
 
 
 
after the job. Those values should be the same. Otherwise you may have some error in 
your measurement. 
b. Monitor FrameCnt value. Its value should increase by ‘15’ and continuously. If it is not 
then play with the threshold adjustment on the TEL Threshold panel. 
 
 
12. Monitor Outputs panel. 
a. CCL value is usually around 19,000. 
b. GR value should read background measurement (normally around 50 GAPI). If GR value 
is too high then you may have radioactive source nearby or you GR tool has not been 
calibrated yet or you may have problem with the GR sensor. 
c. CWH value is around 30,000 cps in air and 10,000 cps in water. 
d. FDEN value is around 1,000 kg/m3 in water (you may only see this value when the tool is 
already into the fluid in the wellbore). 
e. FDIR (FBS spinner) value must be +1 for flowing up indication and ‐1 for flowing down 
indication. 
f. TEMP  value  is  1,600  cps  for  0⁰C.  And  it  will  increase  by  +90  cps  of  every  1⁰C.  For 
example output reading is 1,780 cps for 2⁰C (=1,600 + 2x(90 cps)) 

IV. Calibration 

Temperature: 

There are two ways to calibrate temperature tool: 

1. At Warrior Logging System panel, click Action>Calibrate>Temperature>click Sample for 
each  calibration  reference.  Environment  temperature  for  low  reference  and  heater 
temperature for high reference. 
2. Edit calibration values in Tools.ini (in Config folder). For example, calibration value for 
MUXBTP‐28 is written as following syntax: 

[MUXBTP‐28] 

Model=GOWELL 

TEMP=1264754565,0.02,10600,212,1600,32,0 

is calibration values for MUXBTP‐28 

For logging operational, it is recommended to do only the second way.  

Page | 4  
 
 
 
Quartz Pressure: 

Edit  calibration  values  in  <tool  serial  number>.coe  file.  All  values  in  A,  B,  C,  and  D  are  for 
pressure and all values in E are for Temperature.  

CWH: 

There are two ways to calibrate temperature tool: 

1. At Warrior Logging System panel, click Action>Calibrate>Temperature>click Sample for 
each calibration reference.  
2. Edit calibration values in Tools.ini (in Config folder). 

For logging operational, it is recommended to do only the second way. 

Do  not  forget  to  put  CWH  readings  (in  cps)  in  your  remarks  to  tell  your  client  what  is  the 
standard cps for air and water. 

For example: 

Capacitance measurement in air  : 30,000 cps 

Capacitance measurement in water  : 10,000 cps 

FDT: 

At  Warrior  Logging  System  panel,  click  Action>Calibrate>Temperature>click  Sample  for  each 
calibration reference. 

Low reference: use air 

High reference: use water 

GR: 

At Warrior Logging System panel, click Action>Calibrate>Gamma Ray>put the correct value for 
GR Calibrator (=152 GAPI)>Click Sample>Begin>Accept 

Page | 5  
 
 
 
Additional Information: 

Effect of Gain to Outputs and Sensors reading: 

On Edit Calibration panel, if you insert Gain value=1, then you will have the same values in outputs and 
sensors. Otherwise those values in outputs and sensors would be different. 

Page | 6  
 