Professional Documents
Culture Documents
®
CHANDLER ENGINEERING
Dew Point Testers
Bureau of Mines-Type Dew Point Tester from AMETEK
www.chandlerengineering.com
Dew Point Testers
CHANDLER ENGINEERING
Specifications Options zx Quick Chiller
Chanscope II Dew Point Tester zx Digital Readout Uses the same expandable
Accuracy: The Chanscope II version gases but directs them onto
±0.1°C (0.2°F) down to 0°C (32°F) allows lighted, magnified the back of the polished mirror.
±0.5°C (1.0°F) down to -100°C (- viewing of the dew point with Fast reaction time is achieved,
148°F) a digital temperature display but there is an increased risk of
±1.0°C (2.0°F) down to -200°C (- superimposed on the viewing overshooting the dew point until
328°F) window in tenths of degree. all components reach thermal
Dew Point Temperature Range: The unit also has a button-hold equilibrium.
-200°C (-148°F) to ambient feature to retain the measured zx Liquid Nitrogen Chiller
Operating Pressure: Up to 5000 value. The model uses accurate Uses an immersion rod and
psig (34.6 MPa) platinum RTD and LED Dewar flask containing N2 for
Connections: Sample inlet and readout to give the operator temperatures down to -129°C
outlet: 1/8” NPT; Refrigerant, 1/8” instantaneous feedback during a (-200°F).
tube test.
zx Thermometers
Power: Battery-powered with
115VAC or 230VAC charger. zx Pressure Range A wide range of thermometers
Models are available in ranges of are available in Centigrade or
Ship Weight: 25 lb (11 kg)
1,000, 3,000 or 5,000 psig (7.0, Fahrenheit , including certified
Carrying Case: 14” x 18” x 7”
20.8, and 34.6 MPa). thermometers traceable to NIST.
(35.5cm x 20cm x 17.8cm)
zx Regular Chiller Thermometers are filled with a
Uses liquid propane: -29°C biodegradable liquid, eliminating
Standard Dew Point Tester the safety concerns of mercury.
(-20°F) or liquid carbon dioxide
Accuracy: ± 0.5°F (± 0.25°C)
-62°C (-80°F) as a refrigerant.
Dew Point Temperature Range:
Its geometry optimizes thermal
Dependant on which thermometer is
uniformity for superior control
chosen.
and accurate determination.
Operating Pressure: Up to 5000
psig (34.6 MPa)
Connections: Sample inlet and
outlet: 1/8” NPT; Refrigerant, 1/8”
tube
Ship Weight: 25 lb (11 kg)
Carrying Case: 14” x 18” x 7”
(35.5cm x 20cm x 17.8cm)
CHINA GERMANY
© 2007, by AMETEK, Inc. Beijing / Tel: 86 10 8526 2111, Fax: 86 10 8526 2141 Tel: 49 21 59 91 36 0, Fax: 49 21 59 91 3639
All rights reserved. Printed in the U.S.A. Chengdu / Tel: 86 28 8675 8111, Fax: 86 28-8675 8141 MIDDLE EAST - Dubai
Model 2920 (1/07) Shanghai / Tel: 86 21 6426 8111, Fax: 86 21 6426 7818 Tel: 971 4 881 2052, Fax: 971 4 881 2053
One of a family of innovative process analyzer solutions from AMETEK Process Instruments. SINGAPORE
Specifications subject to change without notice. Tel: 65 6484 2388, Fax: 65 6481 6588