Professional Documents
Culture Documents
EEx-ed-IIC T6 approved
Universal function
Separating diaphragm
isolates solenoid system
from operating fluid
Operational reliability
Insensitive to
contaminated fluids
Design Applications
Technical data
Body Materials Body and seat brass or Operating voltages 24, 110, 230 V/UC
stainless steel 1.4401
Voltage tolerance ±10 %
Seal materials
NBR Neutral fluids, e.g. compressed air, Power consumption
town gas, water, hydraulic oil, oils Inrush UC 40 W
and fats without additives Hold UC 3 W
FPM Hot air, oxygen, per-solutions, hot
oils with additives Duty cycle 100% continuously rated
Use reduced switch-on time for
Max. ambient +55°C manifold installation, depending on
temperature operating conditions.
Times measured at outlet A, from switching on until pressure rise to Installation / Accessories
90 % / pressure drops to 10 % at a max. working pressure of 6 bar.
Single Manifold
or plug-in connector
valve manifold
G 1/4
20
13 G 1/4
58
cable connection
51
9
100
36.5
58
53
73
3000
flanged version
5
M4 ø 4,5
31
11
10.7
24
32
100
38
locked screws
75
53
73
3000
Solenoid Valve with Isolating Diaphragm Type 0780
terminal box
version
131
74
NPT 1/4
G 1/4
19
18
9
9
46
threaded version
flanged version
5
M4 ø 4,5
31
11
10.7
60
24
32
38
locked screws
37 75
123
In case of special requirements, We reserve the right to make technical changes without notice.
please consult for advice. 805-GB/ 1-0158