You are on page 1of 61

Precast

Concrete Products

Bridge Deck Forming and


Hanging Systems

Reinforcing
Bar Supports

Concrete
Anchoring Systems

Rock Anchoring
and Bolt Systems

CONCRETE LIGHT DUTY


FORMING
FORMING MEDIUM & HEAVY
SYSTEMS DUTY FORMING

1
TABLE OF TABLE OF
CONTENTS CONTENTS

Table of Contents Table of Contents

DIAGRAMS Form Brace Aligner.................................................27 MEDIUM/HEAVY DUTY TYLOOP

Snap-Ty System.......................................................7 Plyhole Patch.........................................................27 TYSCRU Tyloop (2-strut).........................................................60

Quick Strip System...................................................8 Scaffold Bracket.....................................................28 Continuous Threaded Lagstud..................................42 Flared 2-Strut Tyloop (TL2F).....................................60

Lagstud/Euro Rod System......................................10 Rod Clamp.............................................................29 Lagstud Bolt.............................................................43 Flared 4-Strut Tyloop (TL4)......................................61

Lagstud System......................................................12 Pencil Rod.............................................................29 Tyscru.................................................................44 Heavy 4-Strut Offset Flared Tyloop (TL4-H)................61

LIGHT DUTY Pencil Rod Tightening Wrench...............................29 Standard Tyscru........................................................47 Flared 6-Strut Tyloop................................................62

SNAP-TY CAM-LOCK FORMING SYSTEM Cone-Ty Tyscru.........................................................47 Tyback Tyloop...........................................................63


Washer

Snap -Ty.................................................................16 Cam-Lock Self Centering D-Cone Ty........................30 Waterseal Tyscru......................................................48 Coil Length...............................................................63
Minimum coil penetration

Plastic Cone Snap-Ty (PC).......................................17 Cam-Lock Stiff-Back Cam......................................31 Adjustable Tyscru......................................................48 SINGLE SIDED FORMING SYSTEM

Plastic Washer Snap-Ty (PW)...................................18 Cam-Lock Bracket.................................................31 Heavy Tyscru (4-Strut and 6-Strut)...........................49 Single End Welding Tyscru.........................................64

Panel-Ty.................................................................18 Cam-Lock Handrail Post.........................................31 Ty-Anchor (2-Strut and 4-Strut)...............................50 Bent Single End Welding Tyscru................................64
Standard

TYSCRU ACCESSORIES
Ty-Frame

No Washer Snap-Ty (NW)........................................19 Cam-Lock Scaffold Bracket...................................32 Toggle Ty......................................................................65

No Spreader Form-Ty (NS)......................................19 QUICK STRIP TY SYSTEM Ty-Frame..........................................................52 Dim. “L”


Angle Ty-Bracket......................................................66
Alternate
Ty-Frame

Fascia Snap-Ty.......................................................20 Quick Strip Ty.........................................................34 Tybow Anchor (2-strut, 4-strut and 6-strut)..............53 T4 Lag Ty..................................................................67

Riser Support.........................................................20 Quick Strip Corner Hinges......................................35 Lagnut....................................................................54


Fill Type Ty-Frame Rock Anchor.............................................................67

Snap-Ty I-Beam Ty (blind wall)...............................21 Waler Bar...............................................................35 Handle Lagnut..........................................................54 AR Rock Anchor Assembly........................................67
8’
Corner Hinges supplied by NCA
3/4”

Carriage Bolts

Space-TyTM........................................................22 Quick Strip Form Panel Construction......................36 Coil Nuts...................................................................55


Sloping Slab
Ty-Frame
Drop-In Anchor.........................................................68
3/4"
Inside Corner

SNAP-TY ACCESSORIES 1/4"


45˚
Residential Ty.........................................................37
Outside Corner
Wing Nut...................................................................55 FormsaversTM.......................................................69
1 3/16" 2 1 /2"

Pressed Steel Ty Wedge........................................24 Residential Ty Accessories.....................................37 Flat Washer...............................................................56 Welding Lagnut.........................................................70

Type H Ty-Wedge....................................................24 STEEL PLY FORMING SYSTEM Batter Washer...........................................................57 Taper-Ty System.......................................................71

A-Bracket..........................................................24 X-Flat Ty.................................................................38 Lag Thread Coupler...................................................57 Tilt Washer................................................................72

Space-T
y Wre
nch
Snap-Ty Wrench....................................................24 Stacking Ty.............................................................38 Plastic Cone-Tight Tycone.........................................58 She Bolt....................................................................73
2X4 Snap-Ty
Waler Lumber
Bracket
Plywood
Panels
Ty

Waler Bracket Forming System..............................25 Spreader Cleat.......................................................38 Plastic Set Back Tyscru Plug......................................58 High Tensile Inside Rod..............................................74
ace
e surf
Concret

2X4 Snap-Ty
Waler Lumber
Bracket
Plywood
Panels

Single Waler Bracket..............................................25 FLATWORK Cone Removal Wrench (T-Shape and L-Shape)........59 Crimped Anchor........................................................75

Strong Back Bracket..............................................25 K-Form PVC Form..................................................39 Lag Wrench..............................................................59 Dummy She-Bolt......................................................76

Plastic Snap-Ty Plug..............................................26 Pin Pocket..............................................................39 Plastic Coil Setting Plug.............................................59 Bowlag Anchor.........................................................76

Plastic Space-TyTM Plug..........................................26 Form Stake............................................................39 Heavy Hex Rod Coupler.............................................77


2 3
TABLE OF
CONTENTS

Table of Contents
25 x 25 mm (1 x 1”)

230 mm
(9”)

Hex Nut.....................................................................77 385 mm (15”) Curb Clamp..............................................................93 Collar of 1 X 6 for


above grade finish

Rod ties sized


to suit

Euro Rod...................................................................78 Corner Clamp...........................................................93

Euro Rod Accessories...............................................78 Barrier Wall Control Joint..........................................94

FORMING ACCESSORIES Expanded Metal Form...............................................94 Rod clamps


securing ties
Wood strong backs
spaced and sized

Hook Anchor Bolt......................................................82 APPENDIX


to suit load

Wedge properly positioned Improperly positioned wedges

Pressure
will loosen and fall off

Wall Plate Anchor......................................................82


Angle

General Guidelines and Conditions..........................96


Ten
sio
CORRECT n
.71 X tie down load = shear load

Pig Tail Anchor Bolt...................................................83 .50 X tie down load = shear load
45˚
Induced Tension Loads............................................100

Te
nsi
on
30˚

Tie
Do
wn
.26 X tie down load = shear load

Lo
ad
Post Holders.............................................................83 Induced Shear Loads...............................................100
15˚

Total shear load

5 5

( ) ( Ff ) <= 1.0 Shear and Tension Loads........................100


3 3
AR Anchor Sleeve.....................................................84 ft
Ft
+ Combined v
v

AR Form Tubes..........................................................85 Stripping of Snap-Tys and guidelines for break back....101


PUMPED
AR Handyform..........................................................85 Rate of pour Concrete lateral pressures for wall form design - PUMPED..102 CONCRETE TEMPERATURE DURING POUR
5° C (40° F) 10° C (50° F) 15° C (60° F)
kPa PSF kPa PSF kPa PSF
1 metre per hour 3'0" per hour 86 1810 72 1500 62 1290
BUCKET

AR Nails....................................................................85 1.5 metre per hour


Rate of pour
2 metres per hour Concrete lateral pressures for wall form design - BUCKET..103
4'0" per hourCONCRETE
5'0" per hour 99
1900 DURING
92 TEMPERATURE
5° C (40° F)
kPa
77POUR 1550

PSF
10° C (50° F)
kPa
1975
PSF
8215° C (60° F)
1625
kPa PSF
67
71
1325
1410
2.5 metres
1 metre per hour 3'0" per6'0"
per hour hour per 69
hour 1450106 58 20751200 88 50 1680
1030 76 1460
31.5metres
metre perper
hourhour 4'0" per7'0"
hour per 74
hour 1520112 62 21251240 93 54 1760
1060 81 1525
P. maximum lateral pressure, psf, for temperature indicated.

AR Concrete Nails.....................................................85 Maximum lateral pressure for design of COLUMN FORMS..104


2 metres per hour 5'0" per hour 79 1580 66 1300 57 1130
3.5
Ratemetres per hour 40° F 8'0" per
of placement 50°hour
F 60° F 2250
70° F 132
80° F 1840
90° F 113 1590
2.5 metres per hour 6'0" per hour 85 1660 71 1350 61 1170
43 metres
metres per hour 7'0" per9'0"
per hour hour
per 90
hour 1700 75
23311410 14465 1910
1220
128 1640
1 foot per hour
4.5 metres
3.5 2metres per per
feet per 10'0"
hour hour 8'0" per
hour hourper 128
hour 1800 10624251470 91 1975
1270 144 1675
4 metres per hour 9'0" per hour 144 1870 120 1530 600 psf
103minimum
1310
3 feet per hour 825 690 governs
As Concrete Cures
4.5 metres P. hour
per maximum
10'0"lateral
per hourpressure, psf,
1940for temperature
134 1580 indicated
115 1340

Falsework Support Bracket.......................................86 Maximum lateral pressure for design of WALL FORMS.....105
Typical 3050mm (10'-0") High Wall Formwork, Typical 3050 mm (10'-0") High Wall Formwork,
CONTROLLED RATE OF POUR FULL LIQUID HEAD 4 feet per hour 664 1050 Snap-Ty 870 750
Form pressure kPa (PSF)
Wall
thickness
Snap-Ty
10 kN (2,250 lbs)
RateConcrete
of placement
Form pressure kPa (PSF) in
40°
10 kN F
(2,250 lbs) 50° F
60° F 70° F 80° F 90° F W6
Wall
Once bottom
thickness
Once second foot of
plastic state foot is cured concrete is cured
0 (0)
W5 spacing: 5 0feet
(0)
per hour 1275 spacing: 1050 900 793 712 650
Millimeters
W1, W2 and W3 W1, W2 and W3 Feet
CONCRETE TEMPERATURE DURING POUR
PSF KPa PSF KPa PSF
(2'-0")
610

@ 305 (12") 3,000 10'


1 foot per 68hour 1500 on centre 681230
@ 305 (12")
610 (2'-0")

6 feet per hour


W5
on centre 150
1050 921 825 750 150 150
W4
Rate of pour 136
2,700
20°
9'
CONCRETE C (70° F) DURING
TEMPERATURE 25° C (80° F)
POUR 30° C (90° F)
2032 (6'-8")

W4 and W5 W4 @ @ 406
300136 300 300
(2'-0")

2,400 8'
610

@ 610 (2'0")
7 of
Rate feet per hour
2pour
feet
(1'-4") on centre
per204hour 1725 W5, W6 204141020° C (70° 1200
F) 25° C1050
(80° F) 600
30°psf
938 C (90°850
F)
610 (2'-0")

450 W4 450
on centre 450
3050 (10'-0")

2,100 7'
3050 (10'-0")

PSFkPa kPa PSF PSF kPakPa PSF kPa PSF


W3
Space-Ty 272 272
@ 610 (2'-0")
600
kPa minimum PSF 600
TM
600
1,800 8 feet per hour
(2'-0")

1950 on centre 3401590 1350


6'
1178 1050 950
610

13.4 kN (3,000
3 feet per hour 825 690 100048
610 (2'-0")

340 750 W3 750 750


governs

Guardrail Base..........................................................87
lbs) spacing:

Lateral Pressure......................................................106
48
1 metre
1,500
metreperper
hourhour 3'0"
hour 408per48
3’0” perSpace-Ty hour 5'
48 10001000 48 48 1000
1000 48 1000
TM
W2 W1, W2 and W3 408 900 900 900
(1'-4")

(1000)
9 feet1050per hourW2 2175
13.4 kN (3,000
lbs) spacing: 1770 1500 1307 1163 1050
406

@ 406 (1'-4") 1,200 4'


4 feet per476hour4’0” per 476
6641000 1000750
610 (2'-0")

1050 48870
1018 (3'-4")

on centre A 1050
W1,hour 1000
1050
1.5 metre per hour 48
48 48
A
W2 and W3

2400 @on4'0" per hour 1000 1000 1000


900 3'
1.5
10 metre
feet perper
hourhour 58 48
(1'-4")
406

W1 B W1 G
W4 and W5 544 406 (16")544
1950 1436 1275 1650 1150
1200 1200 1200
C
C
@ 610 (2'-0") 600 centre 2'

hour5’0” per hour 680 51


7931000 712 1000 1' 1000
D
D
2 metres per hour 680 72 1350
48 48
5 feet
perper 900 650
48 1350
(1000)
E on centre
300
2 metres hour
(1500) W4, W5 and W6 1050
1275
@5'0" per hour 1130 48
E

63 1000 48 1000
(10")

12 foot per hour


MAX.
250

16931000 1500 2850 2310 1950 1350


(10")
MAX.
250

748 1500 748


610 (2'-0") F
F

Typical 6100 mm (20'-0") High Wall Formwork,


2.5 metres per hour
Typical 6100 mm (20'-0") High Wall Formwork,
48 6’0” peron hour
centre 54 1030 48 1000
6 feet per hour
hour 1500 1230 1050 921 825 750
3 14
2.5 feet perhour
metres hour
per 7’0” per6'0"
hour per hour 51 1290
67High Wall Formwork, 51 48 1000 48 1000
CONTROLLED RATE OF POUR FULL LIQUID HEAD
Form pressure kPa (PSF)
Wall
thickness
Typical 3050mm
Form (10'-0")
pressure kPa metres per
Wall
(PSF) High Wall Formwork, thickness 2670
57 1080
Typical 3050 mm 2250
(10'-0") 19501000 1725 1550
1000
CONTROLLED RATE OF POUR FULL LIQUID HEAD
0 (0) Wall
0 (0) Snap-Ty Lateral pressure decreases from
Wall bottom as concrete cures.
Snap-Ty
Space-Ty TM
Snap-Ty
7 feet per hour8’0” 10per 1200 71 1050
2207101010 kN938 850
W13 Form pressure kPa (PSF)

33.516 feet per


perhour 1725 1410
Form pressure kPa (PSF)
lbs) 3000 2550 1950 1750
thickness
metres per hour W15
hour
7'0" 80 1120 (2,25065 1000
metres hour spacing:per hour 1350 1130 1000
thickness
71 63 lbs) 51
kN (2,250 W6

AR Anti-Impalement Rebar Cap................................87


10 kN (2,250 lbs) 13.4 kN (3,000

Light Formwork.......................................................107
0 (0) 0 (0)
spacing: lbs)
spacing:
(2'-0")

spacing:
610

W5
(2'-0")

W12
(2'-0") 610

W1 to W10 @ 305 W1, W1


W2 toand
W12
W3@ 305 W1, W2 and W3
4 18
metres
feetper
perhour
hour
W14
9’0” @per hour 90 1150
2850 81 24641030@ 3052175
(12") 73 1000
1950
(2'-0")

8 feet per
per hour
hour 1246 1090 973 881
610

(12") on centre
3.5 metres
(12")
305
8"0' per1466
1795
on centre
(12")
hour 100 W5
1400 88 1260 81 1000
(2'-0")
3050 (10'-0")

610

on centre on centre
(2'-0")

W11 W11 @ 406 W13 @ 406 (1'-4")


610610

4.5
20metres perhour
feet per hour
W13
W4
10’0” W4
perand
on hour 101 1170
3000 90 27211040W4 @2400
@ 40681 1000
2150
2032 (6'-8")

(1'-4") on centre centre


W5
(2'-0")

9 feetperper hour on@1865 1522 1293 1130


1440 W5,1008 912
610
(2'-0")

4NOTES:
metres hour @9'0"
610 (2'-0")per hour 112 101 1290 91 1000
610
W14(2'0") (1'-4") on centre
610

(1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0") (1'-4") (1'-4") (2'-0")

W12 and W13 and W15


610 (2'-0") 610 (2'-0") 610 (2'-0")

W10 W4
610

centre W12
3050 (10'-0")

@ 610 (2'-0")
The above table is controlled rate of pours (concrete using type 10 or 30 cement,
W6 with no
3050 (10'-0")

22 feet per hour


W3
2979 2625 2350
(1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4")

W9
406 406 406 406 406 406 406 406 406

on centre W11 on centre


Space-Ty TM
@ 610 (2'-0")
305 305 305 305 305 305 305 305 305 406 406

admixtures, ie. per


superplasticizer).
(2'-0")

10 feet hour 13.41935 10'0" per1578 1340 1170 1043 943


610

4.5 metres per hour hour 126 1460 112 1300 101 1000
6100 (20'-0")

Space-Ty TM kN (3,000 on centre


6100 (20'-0")

W8 W3
72 W10 lbs) spacing:
(1500) W7
13.4 kN (3,000
lbs) spacing:
24(1000)
feet per hour
48
W2
W9 W1, W2 and W3 3000 2850
Space-Ty TM
2550
(1'-4")

13.4 kN (3,000
406

W2
W1 to W11 @ 406 (1'-4")
W6
NOTES: Thehour
above table isis controlled rate of pours (concrete using.3000
type 10 or 30 cement, with no W8 lbs) spacing:

Linden Chairs............................................................88 Medium Formwork..................................................108


26 NOTE:Form
feet per
1018 (3'-4")

pressure based on concrete weighing 150 lb/ft on centre


@ 457 (1'-6") A
2750 A
W1,2W2 and W3
(1'-4")

W7
406

W5 on centre W1 B W1 G
W4 and W5 @ 406 (16")
W12 and W13 admixtures, ie. design
Do not use superplasticizer)
pressures
@ 610 (2'-0") plus 25% for
in excess pumped
of 150 concrete.
x height of fresh concrete in forms.
W6 C
C
on centre
3050 (10'-0")

D
W4
@ 610 (2'-0") 28(1000)
feet per hour
48 W5
D
E on centre
72
(1500)
E
W4, W5 and W6 2950
SEE LEGEND
(10")
MAX.

on centre
250

W4 A
(1'-0") (1'-0")(1'-0")(10")

W3
MAX.
250

A F
F ON PAGE 109 @ 610 (2'-0")
30 feet per hour 3000 psf maximum
W3 H
W2
G
C Typical 6100 mm (20'-0") High Wall Formwork,
W2
SEE GENERAL Typical 6100 mm (20'-0") High Wall Formwork,
on centre
3000
CONTROLLED RATE OF POUR FULL LIQUID HEAD
governs
C NOTES ON
W1 D Wall Wall
W1 D Form pressure kPa (PSF)
E Form pressure kPa (PSF)
144 thickness E
PAGE 109 thickness
72
250 (10")

Typical 6100 0 (0)


0 (0) mm
(3000)(20'-0") High Wall Formwork Snap-Ty Space-Ty
Typical 6100 mm (20'-0") High Wall Formwork, TM
MAX.
150

W13
(6")

(1500)
MAX.

F CONTROLLED RATE OF POUR


NOTE:Form pressure is based
10 kN on
(2,250concrete
lbs) weighing 150 lb/ft
W15HEAD2
FULL LIQUID
. 13.4 kN (3,000 Option #1 Option #2
F
Option #1 Option #2
spacing: lbs) spacing:
(2'-0")
610

Do not use W12


design pressures inW10excess of 150 x height of fresh concrete inW1forms.
Form pressure kPa (PSF)
(2'-0")

Form pressure kPa (PSF)


610

W1 to @ 305 W14 to W12 @ 305 T6 T7

(SB) Slab Bolster.......................................................89 Heavy Formwork.....................................................109


T6 T7 0 (0)
0 (0) (12") on centre (12") on centre
(2'-0")

914 (3'-0")

LAYOUT and TY OPTIONS:


3050 (10'-0")

610
914 (3'-0")

(2'-0")

1220 (48")

W11 W11 @ 406 W13 @ 406 (1'-4")


610

W13
(1'-4") on6100 mm (20'-0") High Wall
(4'-0")

centre on centre
1220

T5
T5 Controlled Rate of Pour
(2'-0")
610

(2'-0")

W10 W12 and W13 Diameter of Ty Options W14 andT6W15


610

T6 Layout W12
@Options
610 (2'-0") Tyscru @ 610 (2'-0")
1220 (4'-0")
3050 (10'-0")

Taper Ty
1220 (4'-0")
(1'-4")

914 (3'-0")

W9
406

on centre on centre
(1'-0") (1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0") (1'-4") (1'-4")

W11
305 305 305 305 305 305 305 305 305 406 406

Option - 25 - 32
(3'-0")

T4-27M
914

6100 (20'-0")
(4'-0") (1'-4") (1'-4")

Space-Ty
6100 (20'-0")

TM
W8
406

72
#1 - (1"-1¼") T4 T5
T4 T5 13.4 kN (3,000 W10
(1500) Option 20 - 25 25 - 32
W7
406

lbs) spacing: T4-18M


914 (3'-0")

#2 (¾"-1") (1"-1¼") W9
1220 (4'-0")

W1 to W11
6100 (20'-0")
(3'-0")
1220 (1'-4")

W8
914

W6
406
6100 (20'-0")

72 @ 457 (1'-6") T4
T4 W7
on centre
(4'-0") (1'-4") (1'-4")

W5
406

(1500) T3

(PSB) Slab Bolster and All Plastic Continuous High Chair...89


914 (3'-0")

Approximate safe working loads & ultimate capacities


T3 6100 mm (20'-0") High Wall W6
W12 and W13
3050 (10'-0")

W4 Full Liquid Head


406

(3'-0")
914

3.4 MPa (500 psi) Concrete Strength W5


1220 (4'-0")

4.8 MPa (700 psi) Concrete Strength 10.3 MPa (1500 psi) Concrete Strength @ 610 (2'-0") T3
Diameter of Ty Options
onLayout
centre SEE LEGEND
1220 (1'-4")

W3 T3 W4 A
406

Safe Working Load 2:1 Ultimate Safe Working Load 2:1 Ultimate Safe Working Load 2:1 A
UltimateOptions Tyscru Taper Ty A
ON PAGE 109
914 (3'-0")

Type of Anchor Anchor Dimension kN lbs kN lbs W3 H


kN lbs kN lbs kN lbs kNG lbs
3050 (10'-0")

1220 (4'-0") (1'-4") (1'-4")

W2 A Option 25 - 32 T2
406

T4-27M - SEE GENERAL


(3'-0")

T2 C W2
#1 (1"-1¼")
914

C T2
Tyloop W1 D
Tyloop NOTES ON R
406

1220 (4'-0")

T2
E Option 20 - 25 25 - 32 W1 D
PAGE 109
T4-18M 144 E
914 (3'-0")

72 #2 (¾"-1") (1"-1¼")
250 (10")

Flared 25 x 375 1" x 15" 66 15,000 133 O 30,000 (3000)


MAX.
150
(6")
(3'-0")

(1500)
MAX.

S
914

4 strut 25 x 450 1" x 18" 75 17,000 151F 34,000 F T1


P
T1
T1 T1 144 Q
200 (8")
MAX.

72 (3000)
200

Q
(8")

Flared 4-strut
MAX.

32 x 375 1¼" x 15" (1500) 66 15,000 133 30,000


200
(8")

200
(8")

F
and Offset 32 x 450 1¼" x 18" Not recommended in weak concrete Not recommended in weak concrete 75 17,000 151 34,000

(CHC) Continuous High Chair......................................89 calculated for various concrete strengths................110


F

LEGEND A = 19mm (¾") plywood B = 38X89 (2X4) studs @ 200 (8") on centre C = Two 38X89 (2x4) walers D = Tywedge (sweg-H)
Offset 32 x 600 1¼" x 24" E = Snap-ty106 24,000 F = Footing 213
or Space-TyTM G = 38X8948,000
(2x4) studs @ 150 (6") on centre H = 38X89 (2x4) studs @ 100 (4") on centre
I = 89X89 (4x4) studs @ 250 (10") on centre J = Double waler K = Lagstud bolt, Washer and Nut L = Cone-Tight Tyscru
4-strut 32 x 750 1¼" x 30" 133 studs30,000
M = 89X89 (4x4) 266N = 89X89
@ 200 (8") on centre 60,000
(4x4) studs @ 150 (6") on centre O = Aluminum horizontal walers @ 254 (10") on centre
32 x 900 1¼" x 36" 133
P = Double strongbacks30,000 266
@ 1220 (4'-0") on centre Q60,000
= Form-ty (refer to Laout Options in table above)
R = Aluminum beam or CB walers @ 200 (8") on centre S = Double strongbacks @ 610 (2'-0") on centre
Ty-Anchor 25 x 300 1" x 12" Not applicable 60 13,500 120 27,000 Ty-Anchor Consult the National Concrete Accessories

DIAGRAMS
32 x 375 1¼" x 15" 53 12,000 68 24,000 68 15,500 138 31,000 Technical Department (www.nca.ca) when
2-strut 2-strut

CONVERSION CHART
32 x 435 1¼" x 18" 68 15,500 137 31,000 86 19,500 173 39,000 concrete strengths are less than 3.4 MPa
32 x 500 1¼" x 20" 100 22,500 200 40,000 120 27,000 240 54,000 (500 psi). Estimated practical load values
are shown for various strengths of
Area of rectangle = length x width

Tie Wire....................................................................90
concrete. Safety factors (ultimate load:

Conversion tables...................................................112
4-strut 32 x 600 1¼" x 24" 111 25,000 222 50,000 151 34,000 302 68,000 4-strut
Area of triangle = base x 1/2 altitude working load) is determined at 2:1.

Crimped Anchor 19 x 600


19 x 750
¾" x 24"
¾" x 30"
80
80
18,000
18,000
160
160
36,000
36,000
80
80
Area of parallelogram
18,000
18,000
160
160
36,000
36,000
= base x altitudeCrimped Anchor Use lighter anchor unit in concrete above
4.8 MPA (700 psi) for same load capacity.
19 x 900
32 x 1050
¾" x 36"
¾" x 42"
80
80
18,000
18,000
160
160
36,000
36,000
80
80
Area of trapezoid
18,000
18,000
160
160
36,000
36,000
= altitude x 1/2 the sum of parallel sides
Circumference of circle = diameter x 3.1416 re-anchorage units to safe working load
Loads based Loads based A good forming practice is to preload
25 x 750 1" x 30" Not applicable 120 27,000 240 54,000
on mechanical
on mechanical
25 x 900 1" x 36" 120 27,000 240 54,000 120 27,000 240 54,000
Diameter240of circle
54,000 = circumference x 0.3183
properties only properties only prior to pouring lift. Slippage will indicate
25 x 1050 1" x 42" 120 27,000 240 54,000 120 27,000
inadequate concrete strength. This
Radius of a circle = circumference x 0.159155
25 x 1200 1" x 48" 120 27,000 240 54,000 120 27,000 240 54,000
practice is especially critical in concrete

Tie Wire Twister.........................................................90 GENERAL INFORMATION.........................................116


under 3.4 MPa (500 psi).
Tybow
T2
T2
20 x 450
25 x 450
¾" x 18"
1" x 18"
44
44
10,000
10,000
88
88
20,000
20,000
92 Area of a184
15,000
15,000
circle
184
= square of diameter xTybow
30,000
30,000
0.7854
92 These are guide figures drawn from
T2 32 x 450 1¼" x 18" 44 10,000 88 20,000 92 15,000 184 30,000
T2 T2 comprehensive tests and accumulated

APPROXIMATE WEIGHT OF DRY


somewhatMATERIALS
102 data, and performance will vary
T4 32 x 450 1¼" x 18" 60 13,500 120 27,000 23,000 204 46,000
153 under different conditions.
T4 34 x 600 1½" x 24" 88 20,000 177 40,000 30,000 306 60,000

PerT4 Per Per


T4 162 For specific job conditions a check test
Materials Cubic Metre T6
is recommended under field conditions
Cubic
after aYard
selection is made.Cubic Foot
T6 38 x 600 1½" x 24" 120 27,000 240 54,000 36,000 324 72,000
T6 It is not
considered desirable to plan canteliver
Bow-lag Sand 142 32,000 1600 kg Bow-lag 2700 lbs. operation below 2.7 MPa (400 psi). 100 lbs.

PVC - Single Chamfer...............................................90


19 x 600 ¾" x 24" 53 12,000 106 24,000 71 16,000

Gravel 160 1760 kg 3000 lbs. 110 lbs.


19 x 750 ¾" x 30" 64 14,500 128 29,000 80 18,000 36,000 Type 50, cement jobs have run as low
22 x 750 7
/8 " x 30" 88 20,000 177 40,000 102 23,000 204 46,000 as 450 psi @ 7 days. Below 400 psi,
22 x 900 7
/8 " x 36" 97 22,000 196 44,000 111 Crushed222Stone
25,000 50,000 1475 kg 2500 lbs. cycle increases for 400 psi minimum 92 lbs.
Slag 1185 kg 2000 lbs.
are indicated as good procedures.
25 x 900 1" x 36" 240 54,000 240 54,000 133 30,000 266 60,000
74 lbs.
Cinders 770 kg 1300 lbs. 48 lbs.
Limestone 1715 kg 2900 lbs. 107 lbs.
Cement 1505 kg 2550 lbs. 94 lbs.
Concrete:

Formwork Pry Bar.....................................................91


Blade
Cinder

Trap Rock
Slag
1361-1762 kg
Gravel or Limestone 2400 kg
2485 kg
2240 kg
2300 - 3000 lbs.
4050 lbs.
4200 lbs.
3800 lbs.
85 -110 lbs.
150 lbs.
155 lbs.
140 lbs.

CONCRETE ESTIMATOR

Plastic Form Spreader..............................................91


One Cubic Metre of Concrete Will Place
Thickness m2 Ft 2 Thickness m2 Ft 2 Thickness m2 Ft 2
25mm (1˝ ) 39.4 424 125mm (5˝ ) 7.9 85 225mm (9˝ ) 4.4 47
50mm (2˝ ) 19.7 212 150mm (6˝ ) 6.5 70 250mm (10˝ ) 3.9 42
75mm (3˝ ) 13.1 141 175mm (7˝ ) 5.6 60 275mm (11˝ ) 3.6 38
100mm (4˝ ) 9.8 106 200mm (8˝ ) 4.8 52 300mm (12˝ ) 3.2 35

Rich-Cote Form Release - Summer & Winter Grade....92

Form Sprayer............................................................92
4 5
APPLICATION APPLICATION
DIAGRAM DIAGRAM
APPLICATION

APPLICATION
DIAGRAM

DIAGRAM
Snap-Ty System
B
A Fascia Snap-Ty .............................. page 20
A B Type H Ty-Wedge ........................... page 24
C Space-Ty ........................................ page 22
D Panel-Ty ........................................ page 18
E No Spreader Form-Ty (NS) ................ page 19
F Pressed Steel Ty Wedge .................. page 24
G Plastic Cone Snap-Ty (PC) ................. page 17
C H Plastic Washer Snap-Ty (PW) ........... page 18
I Plastic Form Spreader ..................... page 91
J Form Brace Aligner .......................... page 27
K Scaffold Bracket ............................. page 28

K
I

6 7
APPLICATION APPLICATION
DIAGRAM DIAGRAM
APPLICATION

APPLICATION
DIAGRAM

DIAGRAM
Quick Strip System

Quick Strip Outside


A Quick Strip Ty ................................ page 34
C B Waler Bar ...................................... page 35

Flat Bar Ty System


C X-Flat Ty ........................................ page 38

A Cam-Lock/Anchor-Lock Forming System


D Cam-Lock Self Centering D-Cone Ty.. page 30
E Cam-Lock Stiff-Back Cam .............. page 31
A F Cam-Lock Bracket ......................... page 31
B
G Cam-Lock Handrail Post .................. page 31
H Cam-Lock Scaffold Bracket ............ page 32

E F
G

8 9
APPLICATION APPLICATION
DIAGRAM DIAGRAM
APPLICATION

APPLICATION
DIAGRAM

DIAGRAM
Lagstud/Euro Rod System
C
A D E B
Cam-Lock/Anchor-Lock Forming System
A Lagstud Bolt ............................. page 43
B Lagnut ...................................... page 54
C Flat Washer .............................. page 56
D Plastic Cone-Tight Tycone ......... page 58
F G E Waterseal Tyscru - 4-Strut ....... page 48
F Dummy She-Bolt ....................... page 76
G Heavy Tyscru - 4-Strut ............. page 49
H Wing nut .................................. page 55
I She Bolt ................................... page 73
C H J High Tensile Inside Rod ........... page 74
I J K Taper Ty ................................... page 71
L Heavy Hex Rod Coupling .......... page 77
M Euro Rod .................................. page 78
N Euro Rod Combo Plate ............. page 78
O Handle Lagnut .......................... page 54
K L P Plastic Form Spreader .............. page 91

A E

10 11
APPLICATION APPLICATION
DIAGRAM DIAGRAM
APPLICATION

APPLICATION
DIAGRAM

DIAGRAM
Lagstud System A B C D E F

A Lagstud Bolt ................................. page 43


H B Batter Washer ............................... page 57
C Plastic Cone -Tight Tycone ........... page 58
D Waterseal Tyscru - 4-Strut ........... page 48
G E Flat Washer .................................. page 56
I F Lagnut .......................................... page 54

K L

M
N

G Wingnut ....................................... page 54


H Standard Tyscru - 2-Strut ............. page 47
I P Q
IStandard Tyscru - 4-Strut ............ page 47
J Handle Lagnut............................... page 55
G K She-Bolt ....................................... page 73
L High Tensile Inside Rod ................ page 74
R
M Lag Thread Coupler ...................... page 57
N Crimped Anchor ............................. page 75
O Flared Tyloop - 2-Strut .................. page 60
S T P Continuous Threaded Lagstud ....... page 42
K O Q Welding Lagnut ............................. page 70
R T4 Lag Ty ...................................... page 67
F S Tilt Washer .................................... page 72
T Angle Ty-Bracket .......................... page 66
U U Adhesive Anchor (refer to AR’s Rock
Anchoring and Bolt System catalogue).
V Rock Anchor ................................. page 67
G
W Drop-In Anchor .............................. page 68

F V
W
J

12 13
NOTES

LIGHT DUTY
14 15
SNAP-TY SNAP-TY

Snap-Ty Plastic Cone Snap-Ty (PC)


SNAP-TY

SNAP-TY
AR Snap-Tys are fabricated to fit either prefabricated panels or built-in-place forms. 10 kN (2,250 lbs) Snap-Tys The AR Plastic Cone Snap-Ty and the AR Heavy Duty Plastic Set back Taper Inside to outside
are available in stainless Cone Snap-Ty are equipped with a Plastic Cone Spreader
They are specifically designed for quick, easy and accurate erection of light formwork.
steel upon request.
providing for a 25 mm (1”) set back manufactured for specified 25 mm (1”) 10 mm to 25 mm (3/8” to 1”)
End sizes can be as short as 32 mm (1¼”) for Steel Washer Snap-Tys or as long as you
need them to fit a special condition. Snap-Tys can be fabricated for any required wall NOTE: For Ty removal and wall thicknesses. The plastic cone reduces the likelihood of concrete
break back guidelines paste seepage and protects the break back. The break back is
thickness up to 6 m (19’-6”) in length. Spreader washers are precisely located to give please see page 101 of the Overall length (inside to inside of head)
exact wall thicknesses. Break points are located at specified distances back from the Appendix. approximately 3 mm (1/8”) smaller than the cone length.
End End
wall face to permit clean stripping without spalling. All standard Tys are manufactured The estimated break back is approximately 22 mm (7/8”).
Refer to Lateral Pressure
to provide set back from the wall face. The small Ty holes and washer indentations are Design information on
The table provides the length and taper of the cones.
easily pointed, grouted or plugged. Consult the Technical Department for minimum page 102 and typical Light Special size cones are available as custom orders.
wall thicknesses. For exposed concrete or where a longer set back is required, the AR Formwork on page 107 of Available in stainless steel. Also available in water seal.
Space-TyTM is suggested. the Appendix.
Plastic Cone
Snap-Tys are stocked in 120 mm or 211 mm (4¾” or 8½”) ends for standard wall STANDARD 2.25M HEAVY DUTY 3M Snap-Ty
hicknesses.
APPROXIMATE SAFE APPROXIMATE SAFE 13 mm (½") 13 mm (½")
WORKING LOAD WORKING LOAD Form Wall Form

10kN (2,250 LBS) 13.5 kN (3,000 LBS)


End Wall End 2:1 Safety Factor 2:1 Safety Factor
For architectural design, insert the Plastic Snap-Ty Plug
once form work has been removed.

To order, please specify the following information Plastic


EXAMPLE Snap-Ty
Plug
Name ............................ Plastic Cone Snap-Ty (PC) Plastic Cone
Type ............................................. Heavy Duty 3M Snap-Ty
End ............................................... 120 mm (43/4”)
Wall ............................................... 450 mm (18”)
End ................................................. 120 mm (43/4”)
Break back ....................... (standard) 22 mm (7/8”)
Strength ................................... 13.5 kN (3,000 lbs)
Quantity ......................................................... 300

Any type
Snap-Ty

13 mm (½") 13 mm (½")
Form Wall Form

16 17
SNAP-TY SNAP-TY

Plastic Washer Snap-Ty (PW) No Washer Snap-Ty (NW)


SNAP-TY

SNAP-TY
The AR Plastic Washer Snap-Ty and Heavy Duty Plastic Washer Snap-Ty End Wall End The AR No Washer Snap-Ty and Heavy Duty No Washer Snap-Ty have hex Overall length (inside to inside of head)
are equipped with a plastic washer, provide for a 3 mm to 5 mm (1/8” headed ends. These Snap-Tys are equipped with a 13 mm (½”) break back End End
to 3/16”) break back less than the Plastic Washer Thickness and are and are manufactured for specified wall thicknesses. Available in stainless
manufactured for specified wall thicknesses. The Hex Head allows the Ty steel. Also available in water seal.
end to be broken back prior to removal of the forms, allowing for ease of
stripping. Available in stainless steel. Also available in water seal. Plastic STANDARD 2.25M
Washer To order, please specify
Snap-Ty the following information APPROXIMATE SAFE
13 mm 13 mm No Washer
STANDARD 2.25M (½") (½") EXAMPLE WORKING LOAD Snap-Ty
To order, please specify APPROXIMATE SAFE Form Wall Form Name ............. No Washer Snap-Ty (NW) 10kN (2,250 LBS)
the following information 13 mm (½") 13 mm (½")
WORKING LOAD Type ............................. Standard 2.25M 2:1 Safety Factor
EXAMPLE End ................................ 210mm (8¼”) Form Wall Form
Name ....... Plastic Washer Snap-Ty (PW) 10kN (2,250 LBS) Wall ................................... 200mm (8”)
Type ........................... Standard 2.25M 2:1 Safety Factor Plastic Washer break back is 3 mm to 5 mm
HEAVY DUTY 3M NOTE: For Ty removal and break back guidelines
End ................................ 210mm (8¼”)
End ................................. 210 mm (81/4”) (1/8” to 3/16”) less than the plastic washer thickness. Break back ........................ 13mm (1/2”) APPROXIMATE SAFE please see page 101 of the Appendix.
Wall ................................ 250 mm (10”) HEAVY DUTY 3M Strength ...................10.0 kN (2,250 lbs) WORKING LOAD
End ................................. 120 mm (81/4”) APPROXIMATE SAFE Quantity (lots of 100) ....................... 200 13.5 kN (3,000 LBS)
NOTE: For Ty removal and break back guidelines
Break back ....... (standard) 3 mm (1/8”) WORKING LOAD please see page 101 of the Appendix. 2:1 Safety Factor
Strength ................. 10 kN (2,250 lbs)
Quantity (pkg of 100) ....................... 400 13.5 kN (3,000 LBS)
2:1 Safety Factor

No Spreader Form-Ty (NS)

The AR No Spreader Form-Ty and Heavy Duty No Spreader Form-Ty Overall length (inside to inside of head)
Panel-Ty
are plain rods with a hex headed end. These Snap-Tys are usually End End
withdrawn from the wall or cut off after use. Can be equipped with
The AR Panel-Ty is equipped with a head washer at each end and Length a break back as a special order. Available in stainless steel.
with a large loose-fitting washer at one end. Its function is to tie together
the end-studs of adjacent panel forms. Available in a range of sizes
based on stud requirements. Also available in water seal. STANDARD 2.25M
To order, please specify
the following information APPROXIMATE SAFE 13 mm (½")
13 mm (½")
EXAMPLE WORKING LOAD Form Wall Form

To order, please specify Name ............. No Spreader Form-Ty (NS) 10kN (2,250 LBS)
the following information
STANDARD 2.25M Type ............................. Standard 2.25M 2:1 Safety Factor NOTE: When equipped with break back please see

EXAMPLE
APPROXIMATE SAFE Total Length ... End to End 400 mm (16”) page 101 of the Appendix for Ty removal and break

Name ................................................. Panel-Ty WORKING LOAD Break back ............................ N/A (N/A) HEAVY DUTY 3M back guidelines.
Strength ...................10.0 kN (2,250 lbs)
Length .......................................... 100 mm (4”) 10kN (2,250 LBS) Quantity .......................................... 200
APPROXIMATE SAFE
Quantity .................................................... 200 2:1 Safety Factor WORKING LOAD
SWL is based on an approximate 2:1 Factor of Safety
13.5 kN (3,000 LBS)
Ty wedge 2:1 Safety Factor

18 19
SNAP-TY SNAP-TY

Fascia Snap-Ty Snap-Ty I-Beam Ty (blind wall)


SNAP-TY

SNAP-TY
The AR Fascia Snap-Ty is available for securing light outside spandrel Overall length (inside of head to end of flange) AR Snap-Ty I-Beam Tys are manufactured to fit
beam forms to structural steel beams in the manner shown. Also Break around the I-Beam flange to support the formwork.
available in water seal. A standard break back of 25 mm (1”) is provided.

APPROXIMATE SAFE NOTE: Tolerance for wire bends will be calculated by AR. A 6 mm (¼”)
To order, please specify the following information tolerance may be added to the B & C dimension if desired for Ty placement.
EXAMPLE
WORKING LOAD
Name ........................................... Fascia Snap-Ty 3.6 kN (800 LBS)
End .................................................. 200 mm (8”) 2:1 Safety Factor 13 mm (½") APPROXIMATE SAFE
Overall Length ................................. 600 mm (24”) Form WORKING LOAD
Flange Depth ..................................... 20 mm (3/4”)
Spreader ........................................... Plastic Cone
ALSO AVAILABLE End 10 kN (2,250 LBS)
Break back ........................................... 15 mm (1/2”) WITH ANY TYPE OF 2:1 Safety Factor
Quantity ......................................................... 400 SPREADER WASHER
AND PLASTIC CONE.
To order, please specify the following information
EXAMPLE
Name ................... Snap-Ty I-Beam Ty (blind wall)
Total Ty length:
Sum of:
Dimension “A” (as required)
Dimension “B” (beam height)
Dimension “C” (beam width)
Dimension “B” (beam height)
Riser Support Dimension “A” (as required)
Quantity .......................................................... 200

The AR Riser Support provides a simple solution to support bulk heads for concrete stairs. It comes equipped with Refer to General Guidelines and Conditions on page 96 and
flat washers and a chisel point at both ends. Also available in water seal. Lateral Pressure Design Information beginning on page 102
of the Appendix.

Available up to 200 mm (8") in height. Refer to Lateral


To order, please specify the following information Design information on page 102 and typical Light Snap-Ty I-Beam Ty
EXAMPLE Formwork on page 107 of the Appendix.
Dimension "C"
Name ............................................. Riser Support
Height of riser ................................... 150 mm (6”)
Quantity ........................................................ 200
2 X 4 brace

2 X 4 stud
Dimension "B"
2 X 4 brace

2 X 4 plate
and liners

2 X 4 waler

Dimension "A" Type H Ty-Wedge, nail or


3/4 plywood soffit
secure handle to prevent from opening during pour

20 21
SPACE-TY SPACE-TY

Space-TyTM The Space-TyTM

BREAK BACK ASSURED Designed by AR, the Plastic Space-Ty SPACE-TYTM ASSEMBLY Space-Ty
SPACE-TY

SPACE-TY
The Space-TyTM re-bar locating device protects the Plug provides an easy and very The Space-TyTM combines all essential features for light concrete
break point during the concrete placement assuring economical means of sealing tie holes. forming. The Space-TyTM re-bar locating device securely locks the re-
a positive break and easy removal of the Ty end. bar at a correct distance from the face of the form and eliminates the
need for spacers.
IMPROVED WATER SEAL
Re-Bar affixed to
The plastic locating device is securely moulded to the Concrete Minimum end length of 120 mm (4¾”). Standard sizes stocked in 120 mm (4¾”) or 211 mm (8¼”) ends.
Space-Ty locating device Rebar
Snap-Ty, effectively breaking the wire surface continuity, surface Re-Bar
Locating
reducing the possibility of water seepage. cover "C" FORM TY SPECIFICATIONS Device
Internal form ties shall be so arranged that when the forms are
FIXED RE-BAR LOCATING DEVICE 6 mm (¼") removed, no metal shall be within 40 mm or 50 mm (1½” or 2”) of Rebar
Designed to accept and lock in place 10M, 15M, plug recess any exposed surface as outlined in CSA-A23-3-M90 or ACI 347-95.
or 20M (#4, #5 or #6) re-bar into the correct position, Use Space-TysTM or approved equal and seal the tie holes with PVC
preventing any movement during the concrete Plastic
plugs. The light grey plugs complement the adjacent concrete.
Space-Ty Wrench
placement. Space-Ty
Plug
Tight fit To order, please specify the following information
REMOVABLE PLASTIC CONE
The Removable Plastic Cone provides for an EXAMPLE
architectural recess in the concrete which can be Name ....................................................... Space-Ty
End ................................................... 211 mm (8¼”)
sealed using the AR Plastic Set Back Tyscru Plug
Wall ..................................................... 300 mm (8”) Ty
or by using standard grouting practices. End .................................................... 211 mm (8¼”)
Concrete Ty Break Back
surface 40 mm (1½") “C” dimensions
GUARANTEES CONCRETE COVER or 50 mm (2") Re-Bar 40 mm or 50 mm (11/2” or 2”) ............ 40 mm (11/2”)
The re-bar locating device guarantees the concrete locating device Quantity (pkg of 50) ....................................... 200
Removable
cover as outlined in CSA -A23-3-M90. The Space-TyTM Plastic Concrete surface
rebar locating device complies with the Recommended Cone
Practice for Concrete Formwork as outlined in BREAK BACK TY
Architectural Concrete (ACI 347-95). To facilitate the stripping of forms, the Space-TyTM can be broken
back prior to form removal. Using a Space-TyTM wrench or standard APPROXIMATE SAFE
NOTE: Space-TysTM have a guaranteed standard 40 mm (1½”) set back. A 50
Ty end 13 mm (½”) socket wrench, twist and remove the Ty end. WORKING LOAD
mm (2”) set back is available on special order. Refer to Lateral Pressure Design
information on page 102 and typical Light Formwork on page 107 of the Appendix. 13.5 kN (3,000 LBS)
Break point NOTE: For Ty removal and break back guidelines please see page 101 of the Appendix. Refer to Lateral
of Ty Re-Bar Pressure Design information on page 102 and typical Light Formwork on page 107 of the Appendix. 2:1 Safety Factor

End End
Guaranteed concrete cover Wall thickness
Form + 13 mm (½") Form + 13 mm (½")
For exposed conditions of Re-bar cover
Tywedge
40 mm, 50 mm (1½”, 2”) "C" "C"

Consult the NCA Technical


Department for minimum
wall thickness

22 23
SNAP-TY SNAP-TY
ACCESSORIES ACCESSORIES

SNAP-TY ACCESSORIES Waler Bracket Forming System


Pressed Steel Ty Wedge
The AR Waler Bracket is a proven method to form light weight walls and foundations. The basic unit of this
system is the bracket with a moving wedge which provides the most effective type lock for the Snap-Ty. The basic
The AR Pressed Steel Ty Wedge is designed to slip over the head of a standard components are the Waler Bracket and Snap-Tys, with plywood panels and loose 38 mm x 89 mm (standard 2x4
or heavy duty Snap-Ty to safely secure the waler system in place. Caution walers). No nailing is needed. Erection and stripping are made fast and simple and materials last longer. The Waler
ACCESSORIES

ACCESSORIES
SNAP-TY

SNAP-TY
should be used when used with hex head Space-TyTM or Snap-Ty products. Bracket Forming System will save up to 50% of the forming cost.

APPROXIMATE SAFE
To order, please specify the following information
WORKING LOAD Single Waler Bracket
EXAMPLE Any type
Name ...............................Pressed Steel Ty-Wedge 13.5 kN (3,000 LBS) Pressed Steel
Snap-Ty

Quantity .......................................................... 200 2:1 Safety Factor Ty Wedge The AR Waler Bracket is designed to be used with any AR 2X4 Snap-Ty
Waler
Short-End Snap-Ty. The durable bracket can be used with both Bracket
Lumber

horizontal walers and vertical studs for any type of wall form;
Plywood
Type H Ty-Wedge round, curved, battered, beam and/or columns. The Single Panels
Waler Bracket is fabricated from heavy gauge steel which is
plated to resist corrosion for improved durability and reuse.
AR Type H Ty Wedges are manufactured from a malleable cast iron
material designed to slip over the head of a standard or heavy duty Type H To order, please specify the following information
Snap-Ty. The Type H-Ty Wedge provides for long term durability, Ty-Wedge
EXAMPLE
performance and bearing area to ensure proper load distribution on Name .................................... Single Waler Bracket
to the waler system. Quantity .......................................................... 200
Any type
Snap-Ty
APPROXIMATE SAFE
To order, please specify the following information APPROXIMATE SAFE WORKING LOAD
WORKING LOAD
EXAMPLE 12 kN (2,700 LBS)
Name ...................................... Type H Ty-Wedge 13.5 kN (3,000 LBS)
2:1 Safety Factor
Quantity (lots of 50) ....................................... 200 2:1 Safety Factor

A-Bracket Strong Back

The AR A-Bracket is used to hold a horizontal waler bar, or a vertical stud with any The AR Form Aligner Clamp is designed for use with a single 38 mm x 89 mm (2" x 4") strong back
type of wall form. The built-in slot allows the bracket to slip over 4-3/4" L&W snapties, for either vertical or horizontal form alignment. The Form Aligner Clamp can be installed after
and can be installed before or after waler bars have been positioned. The swivel erection of the forms and is not limited by form-ty spacing. Sturdy, galvanized construction
bracket allows the snaptie end to lock-in and tightens on the 2 x 4 waler. The swivel reduces maintenance and replacement and speedy installation reduces forming costs.
bracket allows for 5/8" of adjustment to compensate for lumber variations.
2X4
Stiff-Back

Snap-Ty Wrench
Rotate Tighten
The AR Snap-Ty Wrench is designed to fit tight again the wall and facilitate the Wedge Wedge
Snap-Ty break back once the concrete has cured. The angle of the Snap-Ty Wrench with
will prevent scraping of knuckles during the end removal. After the form has been Form hammer
Spa Aligner
removed, place the Snap-Ty Wrench on the Ty. Keep the Snap-Ty Wrench against ce-T Clamp
Space-Ty Wrench yW
the concrete, bend the Ty towards the concrete surface. Rotate the wrench using renc
h
a cranking motion to break the Ty back within the concrete wall.
Ty
To order, please specify the following information To order, please specify the following information
Ty
EXAMPLE EXAMPLE
Name ......................................... Snap-Ty Wrench Name ................................................. Strong Back
Con
Quantity .............................................................. 2 cret Quantity .......................................................... 200
Concrete e surface
surf
ace

24 25
SNAP-TY SNAP-TY
ACCESSORIES ACCESSORIES

Plastic Snap-Ty Plug Form Brace Aligner

AR Plastic Snap-Ty Plugs are designed to provide an economical The AR Form Brace Aligner is designed to assist
means of sealing Snap-Ty Cone holes, eliminating the need for in accurately positioning and plumbing vertical
grouting. The Plastic Snap-Ty Plug provides an architectural design forms. The heavy 25 mm (1”) open style turnbuckle
in concrete walls and should be installed with a commercial grade provides for fast, easy adjustments. The Form
ACCESSORIES

ACCESSORIES
SNAP-TY

SNAP-TY
adhesive material. Available in a standard grey colour. Other colours Brace Aligner is equipped with a bent nailing plate
are available on special orders based on minimum quantities. and holes. Manufactured from first quality materials
for durability and repeat use. The Approximate Safe
Working Loads of the aligner are limited by the field
To order, please specify the following information
fastening and staking method. The Form Brace
EXAMPLE
Aligner splicer unit provides for 90 mm (3½”) total
Name .................................... Plastic Snap-Ty Plug
Quantity ......................................................... 200
adjustment. The overall maximum length is 1,040
mm (41”) with a minimum length of 950 mm (37½”).
Also available in adjustable. Form Brace Aligner
Plastic Snap-Ty Plug provides a recess of
approximately 5mm (¼”).
Snap-Ty
To order, please specify the following information
2x4
EXAMPLE
2x6
Name ..................................... Form Brace Aligner
Snap-Ty Plastic Quantity ............................................................. 2
Cone cavity Snap-Ty
Plug NOTE: Not designed for wind loads.

Refer to General Guidelines and Conditions on page 96 and Lateral


Pressure Design Information beginning on page 102 of the Appendix.

Plastic Space-TyTM Plug

AR Plastic Space-TyTM Plugs are designed to fit securely in Plyhole Patch


the cone hole of a AR Space-TyTM once the Ty break back is
established in the concrete wall. The Space-TyTM Plug is a
simple and economical means of sealing Space-TyTM holes The AR Plyhole Patch is designed to facilitate Ty hole
providing an architectural design. repairs in wood formwork. Manufactured from 26 gauge
galvanized steel, the 60 mm (2¼”) diameter patch comes
complete with its own fastening system. The self
To order, please specify the following information contained barbs eliminates the requirement for nails.
EXAMPLE Also available in plastic.
Name .............................. Plastic Space-TyTM Plug
Colour .................................................... light gray
To order, please specify the following information
Quantity .......................................................... 200
EXAMPLE
Name ............................................... Plyhole Patch
Quantity (lots of 1,000) ................................ 1,000
NOTE: Do not use Plastic Snap-Ty
Plugs with AR Space-TysTM.

Ty Hole

Plyhole Patch

26 27
SNAP-TY PENCIL
ACCESSORIES ROD

Scaffold Bracket Rod Clamp

The AR Scaffold Bracket (TSB) meets most AR Rod Clamps are malleable castings for plain or deformed re-bar ty systems.
Insert The Rod is clamped by a set screw and nut arrangement which tightens the grip as the
local code requirements and is suitable for most 2x4
formwork systems. The Brackets are adjustable to load is applied. The clamp housing may be used indefinitely. The only wearing element
fit vertical or horizontal wales and/or strongbacks is the relatively inexpensive nut and screw which can be replaced at will. The Rod
ACCESSORIES

Clamps are supplied with nail holes to simplify the attachment operation on the walers.
SNAP-TY

by simply adjusting the pins position in the vertical

PENCIL
ROD
or horizontal members. The AR Scaffold Bracket Once the Ty rod is tightened and secured, bending the rod behind the clamp at 90° will
(TSB) can also be flush mounted to concrete provide an additional measure of safety.
surfaces and is also easily adapted to custom Diameter Tightening
prefabricated forms. To order, please specify the following information Wrench Rod Clamp
6 mm (1/4”)
EXAMPLE
Consult your AR Area Sales Representative or the 10 mm (3/8”)
Name ................................................... Rod Clamp
AR Technical Department for additional information.
Rod Diameter ....................................... 6 mm (1/4”) 13 mm (1/2”)
Quantity .......................................................... 200

APPROXIMATE SAFE Refer to General Guidelines and Conditions on page 96 and Lateral Pressure Design Information beginning on page 102 of the Appendix.
Allow 175 mm (7") for Tightening
Wrench and Rod Clamp
WORKING LOAD
4.5 kN (1,000 LBS)
4:1 Safety Factor Pencil Rod

The AR Pencil Rod System is an economical forming


system, used mainly for battered walls and foundations
40" where the use of the AR Snap-ty is not feasible.
Available in 1/4" diameter, cut to 10' or 20' lengths.
Use where a clean breakback is not necessary. For use Diameter
with the AR Rod Clamp and AR Tightening Wrench. mm (in) kN (lbs)
6 1/4" 10' 1,125
6 1/4" 20' 1,125

Pencil Rod Tightening Wrench

35" The AR Tightening Wrench is placed over a smooth or deformed rod behind
Built-in a rod clamp and is used to draw the assembly tight, allowing the clamp to be
receptacle
for 2 x 4
properly tightened. The Tightening Wrench is available in ¼”, 3/8” and ½” sizes.
8' Maximum
Centers Handrail Tightening Allow 100 mm (4") past
Post Wrench Rod Clamp wale and bend rod at 90˚
Scaffold
Bracket

Caution: Do not use the Tightening


Allow 175 mm (7") for Wrench for straightening forms or
Tightening Wrench and Rod Clamp
for pulling smooth rods from set
APPROXIMATE SAFE WORKING LOADS concrete.
To order, please specify 2:1 Safety Factor
the following information Diameter
EXAMPLE mm (in) kN (lbs)
Name ....... Tightening Wrench 6 mm (¼”) 5 kN (1,125 lbs)
Size ..................... 13 mm (1/2”) 10 mm (3/8”) 10 kN (2,200 lbs)
Quantity ......................... 200
13 mm (½”) 15 kN (3,750 lbs)

28 29
CAM-LOCK & CAM-LOCK &
ANCHOR-LOCK ANCHOR-LOCK

Cam-Lock Forming System Cam-Lock Stiff-Back Cam

The AR Cam-Lock Forming System takes advantage of inexpensive forming materials, S4S 2x4s with 4’x8’x¾” The AR Cam-Lock Stiff-Back Cam is used in combination with the Cam-Lock
or 2’x8’x¾” plywood sheets. When used for built-in-place forming, no ribbing or special hardware attached to Bracket to support the 2x4 strong-backs to the form, providing additional strength
the panels is necessary. The use of stiffbacks and walers is cut in half. Walers may be used either vertically or and form alignment. Also available as a 2x6 stiff-back as a special order.
horizontally, but field tests have proved the latter method to be easier and faster.
Cam-Lock
To order, please specify the following information Stiff-Back Cam
The Cam-Lock Bracket holds the 2x4 waler in place by locking to the loop-end ty through caming pressure.
EXAMPLE
Further rigidity of the form may be obtained through use of the Cam-Lock Stiff-Back Cam which connects to the Name .............................. Cam-Lock Stiff-Back Cam
& ANCHOR-

& ANCHOR-
CAM-LOCK

CAM-LOCK
ears on the back of the Cam-Lock Bracket, locking either a 2x4 or 2x6 in place with the same caming principle.
LOCK

LOCK
Quantity ......................................................... 200
This also assures perfect alignment of the form from top to bottom and enhances the system’s adaptability to
extremely high, close tolerance work.
APPROXIMATE SAFE
Cam-Lock
The extreme rigidity of Cam-Lock Forming System makes it adaptable to all types of construction, and this same WORKING LOAD Bracket
rigidity, coupled with the Cam-Lock Scaffold Bracket, makes it especially desirable for high wall forming. Economy 10 kN (2,250 LBS)
of the system is realized in labour costs through the simplicity of the system as well as the increased man-hour
production that result from easier handling of the light weight plywood sheets. Since only half as much dimension 2:1 Safety Factor
lumber is used, further savings are derived from lower material costs. Refer to General Guidelines and Conditions on page 96 and Lateral
Pressure Design Information beginning on page 102 of the Appendix.

Cam-Lock Self Centering D-Cone Ty Cam-Lock Bracket

The AR Cam-Lock Self Centering D-Cone Ty features a high density The AR Cam-Lock Bracket accomplishes many purposes in one
polyethylene Cone Washer. This Cone Washer will not absorb moisture accessory. It is a support for normal S4S, 2x4 walers. It has dual-ears
or stick to the concrete, preventing break back problems. A smooth, for the support of the Cam-Lock Scaffold Bracket and the Cam-Lock
uniform hole results after break back, allowing easier grouting and Stiff-Back Cam. The forged cam finger grips the Ty loop securing it
faster, better finishing. The standard 25 mm (1”) D-Cone comes with plywood
firmly to the form panel. The malleable cast bracket is designed with
a 25 mm (1”) break back. Self-centering tapered cones require a drill additional strength provided for at the points of strain. The Cam-Lock
hole size of 21 mm (13/16”). Bracket may be used with either horizontal or vertical walers.
25 mm (1") Cam-Lock Brackets may be used as a built-in-place forming system 2 X 4 Stiff-Back
break back or attached to the plywood when used for gang forming.
To order, please specify APPROXIMATE SAFE Cam-Lock
Bracket
the following information
WORKING LOAD
EXAMPLE
10 kN (2,250 LBS) To order, please specify APPROXIMATE SAFE Horizontal
Waler
Name ........ Cam-Lok Self Centering D-Cone Ty the following information WORKING LOAD
Quantity .................................................... 200 2:1 Safety Factor EXAMPLE
10 kN (2,250 LBS)
Name ................................. Cam-Lock Bracket
Quantity .................................................... 200 2:1 Safety Factor Plywood
Cam-Lock
Stiff-Back Cam
Block

Cam-Lock Handrail Post

The AR Cam-Lock Handrail Posts are required with the use of all Cam-
Lock Scaffold Brackets. A 1,065 mm (42”) guard post with toeplate,
mid-rail and top rail must be used. This requirement can easily and
economically be met with the use of the Cam-Lock Handrail Post.

To order, please specify the following information


EXAMPLE
Name .............................. Cam-Lock Handrail Post
Refer to General Guidelines and Conditions on page 96 and Lateral Quantity .......................................................... 200
Pressure Design Information beginning on page 102 of the Appendix.

30 31
CAM-LOCK CAM-LOCK

Cam-Lock Scaffold Bracket Ty spacing for regular forming

The AR Cam-Lock Scaffold Bracket is constructed of sturdy,


heavy gauge pressed steel. Extra rigidity is obtained by spot 20 mm (¾") Plywood
welded corner gusset plate and tubular riveted bracing. 2X4 Waler
Hanger arms attach to the Cam-Lock Bracket ears in the same
manner as the Cam-Lock Stiff Back Cam. Secure, firm
attachment in seconds is accomplished without bolts, nuts Panel Ty
or nails. It is quickly adaptable for use with 2x6 Stiff-Back Double
CAM-LOCK

CAM-LOCK
by removal and repositioning of hanger arms. All new Scaffold Walers
Brackets are factory tested to 3,000 lbs. at joint

To order, please specify APPROXIMATE SAFE


the following information
WORKING LOAD
EXAMPLE
Name ............ Cam-Lok Scaffold Bracket
11 kN (2,500 LBS)
Quantity ........................................... 200 2:1 Safety Factor Panel

DON’Ts NOTE: Drill 13/16" Ty holes.


· Never use the Scaffold Bracket with a short 2x4. Always use
full length 2x4s that extend to a solid base.
· Never use the Scaffold Bracket with only one scaffold plank.
· Always use two approved 2x12 scaffold planks side by side.
DOs 20 mm (¾") Plywood
· The vertical 2x4 stiff-back must always extend to a Stiffback Cam
solid base — the concrete footing, a floor slab or to 2X4 Waler
compacted soil.
· The Scaffold Bracket must be attached to the second Cam-lock Bracket
Cam-Lock
cam-lock form. Never attach the Scaffold Bracket to the Handrail Post Ty 2X4 Stiffback
top row of cam-lock brackets and form ties. Panel
· A 2x4 stiff-back cam must always be attached directly
below the Scaffold Brackets.
· A second 2x4 stiff-back cam must be attached directly
below the Scaffold Bracket.
· Add an additional stiff-back cam at the bottom of the
vertical 2x4 stiff-back to stabilize it.
· Scaffold Brackets are to be used on 6’ centers along
the form with two 2 x 12” scaffold planks.
Cam-Lock
· A 42” guardrail with a 2x4 toeplate, mid-rail and top rail Scaffold
must also be used. Bracket
Since we cannot anticipate every problem that may arise Stiffback
on the job in conjunction with the use of our product, Cam
we urge you to work safely and refer to your manuals
for proper construction of concrete wall forming and
scaffolding procedures Cam-lock Bracket

2X4 Stiffback
Not to be used above 6.0 m (20’-0”). Any scaffolding above six metres (twenty feet) should be checked with local, provincial code requirements.

32 33
QUICK STRIP QUICK STRIP
TY SYSTEM TY SYSTEM

Quick Strip Ty System Quick Strip Corner Hinges

The AR Quick Strip Ty System is designed to provide a true, smooth wall for light forming applications. The AR AR Quick Strip Corner Hinges provide an alternative method to achieving corner details.
Quick Strip Tys are designed to be simply inserted through pre-manufactured slots in 20 mm (¾”) plywood form Hinges are secured to the Form Ply by using a simple carriage bolt. The hinges allow for
panels. They are secured in place by using a waler bar, which allows for quick form erection as well as efficient a 15 mm (5/8”) smooth rod or rebar to pass through, holding the forming securely in place.
form stripping operations. The corner hinges are designed to work for both inside and outside corners.

To order, please specify


the following information
EXAMPLE
Name ......................................... Corner Hinges
Quantity .................................................... 200
QUICK STRIP

QUICK STRIP
TY SYSTEM

TY SYSTEM
Plywood
Waler Bar
Removed
The AR Quick Strip Ty Waler Bar is used to secure the Quick Strip Tys 8’
and form panels in place. The Waler Bar overlaps the adjacent edge of
the form ply to increase the wall stability when pouring concrete. The 3/4”
Waler Bars are 6 mm x 20 mm x 2,400 mm (¼” x ¾” x 8’) and are made
from high quality carbon steel with milled edges for smooth installation.

Waler Bars must overlap plywood edges


To order, please specify Plywood edges Waler Bars
the following information
EXAMPLE
Quick Strip Ty Name .............................................. Waler Bar
Quantity .................................................... 200

AR Quick Strip Tys are available for wall


thicknesses ranging from 100 mm to 750 mm
(4” to 30”) and are designed to reduce waler
and bracing requirements.

To order, please specify the following information


EXAMPLE
Name ............................................ Quick Strip Ty
Length ............................................ wall thickness
Quantity ......................................................... 250

APPROXIMATE SAFE Staggered spacing of Waler Bars increases form stability


WORKING LOAD
5 kN (1,150 LBS)
2:1 Safety Factor

Refer to General Guidelines and Conditions on page 96 and Lateral Pressure Design Information Refer to General Guidelines and Conditions on page 102 and Lateral Pressure Design Information
beginning on page 102 of the Appendix. beginning on page 102 of the Appendix.

34 35
QUICK STRIP RESIDENTIAL
TY SYSTEM TY

Quick Strip Form Panel Construction Residential Ty

Form panels are easily built. Rout ¼” x 1” ty slots in ¾” plywood. A template The AR Residential Ty is designed for modular forming systems utilizing 1-1/8" Wall Thickness Box Qty
out of ¼” plywood 6” x 7” cut-outs centered over the location where the ty plywood. Crimped wires are designed to be secured in place by clips on the 8"
slots are to be cut. A 6” x 6” x ¼” block fastened to the face of an electric Corner Hinges supplied by NCA outside of the form and then are snapped off after the stripping of the forms 9"
router using a ¼” carbide bit will cut the ty slots the required size, ¼” x 1”. using a break off tool. Available in standard sizes of 8"-10", 12"-14", 16", 18", 10" 250
If desired, 4’ x 8’ outside panels may be used. 20", 22" and 24". Additional sizes available on request. 12"
Carriage Bolts 13"
14"
16"
18"
100

RESIDENTIAL
QUICK STRIP

20"
TY SYSTEM

TY
3/4"
22"
Standard 2’ x 8’ panel Inside Corner 24"

1/4" Outside Corner


45˚

1 3/16" 2 1 /2" Residential Ty Accessories

AR offers the supporting accessories used in 1-1/8" plywood modular forming. Standard 6" latch, top waler and tie
breaker tool, along with other accessories are available.

NOTE: AR Quick Strip


Tys can be used without
Standard 6" Latch Additional Accessories
plywood panels, if
desired. Tys can be · Radius Wall Clip
slipped between common
board and steel bars · Stacking Clip
set vertically, eliminating · Corner Latch
most of the nailing and · Form Screws
walering required.
· Shoulder Bolts
Please consult your Ty Breaker Tool · E-Clip
local AR Technical · Half Clip
Representative or our
Technical Department · Sleeve Nuts
for Ty spacing.

Top Waler

Corners are made from ¾” plywood, and hinges supplied by AR. Corner shown is the standard 2’
and works best on most jobs. Corners are connected by inserting a 5/8” rod through the hinges.

36 37
STEEL PLY FLATWORK
FORMING
SYSTEM

Steel Ply Forming System Flatwork

X-Flat Ty K-Form PVC Form

K-FORM is a lightweight PVC cast in place formwork, replacing


The AR X-Flat Ty is designed to be used with modular form systems. Used in Wall Size SWL (lbs)
steel and wood forms where control joints are needed. The pre-
conjunction with a wedge bolt, it creates a secure form tie. The AR X-Flat Ty comes 8" 3,000
drilled 1" holes on the vertical wall allow for locating dowel bars,
with a standard 1/4" set back. Available for 8", 10" and 12" wall sizes, additional 10" 3,000
and the holes on the horizontal surface are used for anchoring
wall sizes available on request. 12" 3,000
with mortar. This all-in-one screed rail system is easy to use
and is designed to save time and labour on the job site. Once
APPROXIMATE SAFE concrete is cured, they can be left in place, no need to remove
STEEL PLY
FORMING
SYSTEM

WORKING LOAD and clean. K-Forms are available in 2", 4" and 6" heights and
2:1 Safety Factor standard 8' length. Custom sizes and length can be requested.

FLATWORK
Height Length
2”
4” 8’
6”

Stacking Ty
Pin Pocket
The AR Stacking Ty, also referred to as "Snapie Ty", is used in light Plywood Size Size SWL (lbs) Box Qty
duty 1-1/8" plywood forming systems. Available in 5-5/8" to 12" sizes. 5-5/8"
Additional sizes available on request. 6" The AR Pin Pocket, also referred to as "curb clamp", is
7-5/8" a strong and durable clamp used for securing pins and
8" forming stakes to the wood form. Coated with black paint
1-1/8" 1,500 100 for corrosion protection. Available 40 pieces per box.
9"
10"
11-5/8"
12"

APPROXIMATE SAFE
WORKING LOAD
2:1 Safety Factor
Form Stake
Spreader Cleat
AR Form Stakes are manufactured from high quality steel with a sharp
The AR Spreader Cleat is used to spread and hold the top and bottom Plywood Size Size SWL (lbs) Box Qty point to minimize rock deflection. Form Stakes are available in 20 mm (¾")
of forms during concrete pour. The nail holes can be used to secure the 5-5/8" and 22 mm (7/8") diameters and in standard lengths of 450 mm, 600 mm,
cleats to the form. Available in 6"-12" standard sizes, for use with 3/4" 6" 750 mm and 900 mm (18", 24", 30" and 36"). The Form Stake is equipped
and 1-1/8" plywood systems. Additional sizes available on request. 7-5/8" with spiral-patterned nail holes for use as form pins.
8"
1-1/8" 1,500 100
WALL THICKNESS 9"
10" To order, please specify
11-5/8" the following information
12" EXAMPLE
Name ............................ Form Stake
PLYWOOD APPROXIMATE SAFE Diameter ..................................... 3/4"
Length ........................................ 24"
WORKING LOAD Quantity ........................................ 10
2:1 Safety Factor
38 39
NOTES

MEDIUM/
HEAVY DUTY
40 41
CONTINUOUS CONTINUOUS
THREADED THREADED
LAGSTUD LAGSTUD

Continuous Threaded Lagstud Continuous Threaded Lagstud

The Acrow-Richmond Lagstud is perhaps the most versatile of all the members of the AR Tyscru family. This Lagstud Washer
versatile product can be used in combination with the complete line of Tyscru products. Continuous Threaded
Lagstud is available in both mild steel and high tensile in 3 m (10’) and 3.6 m (12’) lengths respectively. Field cutting
may be accomplished with bolt cutters or carborundum blades.
The Lagstud is particularly adaptable in combination with Tyscrus to make adjustable Tys, embedded in concrete
or rock as an adjustable anchorage for the Tyscru, or in combination with Handle Lagnuts as an emergency
Tyscru
lagstud bolt.
Handle Lagnut

Lagstud

APPROXIMATE SAFE
WORKING LOAD
2:1 Safety Factor
CONTINUOUS

CONTINUOUS
THREADED

THREADED
LAGSTUD

LAGSTUD
LAGSTUD TENSILE PROPERTIES
H
Washer Lagstud
Mild Steel High Tensile Steel
Diameter Ultimate Loads Safe Working Loads Ultimate Loads Safe Working Loads
in (mm) lbs (kN) lbs (kN) lbs (kN) lbs (kN)
½ (13) 15,000 (70) 7,000 (33) 18,000 (80) 9,000 (40)
Lagstud Tyscru Grout
¾ ( 20) 36,000 (160) 18,000 (80)
1 (25) 50,000 (220) 25,000 (110) 75,000 (335) 37,500 (165)
1¼ (32) 74,000 (330) 37,000 (165) 120,000 (530) 49,000 * (216)*
Lagstud Bolt
1½ (38) Contact the AR Technical Department for details.
AR Lagstud Bolts are threaded for the coil of an AR Tyscru or APPROXIMATE SAFE
*When using 32 mm (1¼”) High Tensile Lagstud, use double nuts to obtain full capacity of Rod, 265 kN (60,000 lbs). insert. Available in ½”, ¾”, 1” and 1¼” (13 mm, 20 mm, 25 mm WORKING LOAD
and 32 mm) diameters and lengths as required in 2” (50 mm)
2:1 Safety Factor
LAGSTUD FOR EMBEDDED ANCHORS increments. All Lagstud Bolts have a hexagon nut welded to
it as an integral head, and should be used with a running nut,
Diameter Approx. Safe Working Loads @ 2:1 Embedment “H” Diameter Mild Steel High Tensile
handle lagnut or wingnut as shown.
in (mm) lbs (kN) lbs (kN)
1,000 psi (6.9 MPa) 2,000 psi (13.8 MPa)
in (mm) lbs (kN) in (mm) in (mm) ½ (13) 7,000 (33) 9,000 (40)
To order, please specify
½ (13) 4,500 (20) 16 (408) 12 (304) Washer To order, please specify
the following information ¾ (20) N/A N/A 18,000 (80)
the following information
½ (13) 6,750 (30) 20 (508) 15 (378) EXAMPLE
EXAMPLE 1 (25) 25,000 (110) 37,500 (165)
Name ....... Continuous Threaded Lagstud
¾ (20) 9,000 (40) 24 (609) 18 (458) Name ............. Lagstud Bolt
Type ................................................... 9M 1¼ (32) 37,500 (165) 49,000* (216)
Diameter .......... 13 mm (½”)
1 (25) 13,500 (60) 32 (816) 24 ( 609) Diameter .............................. 13 mm (½”)
Length ......... 400 mm (16”) 1½ (38) Contact the NCA Technical Department for details.
Length ................................... 3.6 m (12’)
1 (25) 18,000 (80) 40 (1,020) 30 ( 760) Type ........ 33 kN (7,500 lbs)
Grade of Steel ...................... High Tensile *When using 1¼” (32 mm) High Tensile Lagstud, use double nuts to
Quantity ...................... 200
1¼ (32) 27,000 (120) 40 (1,020) 30 (760) Quantity .............................................. 50 Minimum coil penetration obtain full capacity of Rod, 60,000 lbs (265 kN). All lagstud bolts to
be used with running nut, handle lagnut or wing nut.

Refer to the Appendix for General Guidelines on page 96, Lateral Pressure
information on page 102 and typical Medium and Heavy Formwork
beginning on page 108. See page 51 for approximate safe working load System Chart.

42 43
TYSCRU TYSCRU

Tyscru Tyscru

The AR Tyscru is an extra strong,


Battered Wall Form
resistance welded Ty designed to
take the abuse encountered in
Form Wall thickness Form thickness
medium and heavy concrete
construction. An extremely simple Flat Washer thickness Flat Washer
Ty, capable of many combinations thickness
and uses in the field, it may be used
Setback Wedge
with or without Tycones or combined
with Continuous Threaded Lagstud
to form an Adjustable Tyscru Tyscru length

Determining your Tyscru Requirement Coil penetration


TYSCRU

TYSCRU
Tyscru: The Tyscru length is determined by subtracting each set back requirement from the wall thickness at the
tie location. Lagstud or lagstud bolt length is determined by adding the form thickness to the set back on one side
plus the Tyscru coil length plus 13 mm (½”). Lagstud or Lagstud Bolt are furnished standard in even 50 mm (2”) Lagstud Bolt length
lengths. Select the next higher full unit over actual length determined. For extreme adjustment requirements,
25 mm to 50 mm (1” to 2”) may be added.

Wall Thickness: Distance between the form facings at the Tyscru location. Plumb Wall Form

Set Back: Required distance of Ty metal from the finished concrete face with or without the use of Tycones. Form thickness Wall thickness
Set back may be required at one or both faces, usually both. Total set back is the sum of set backs from both wall
faces. When Tycones are used, their length is equal to the required set back. Flat Washer thickness

Form Thickness: Distance measured between the finished concrete surface to the outside face of the flat washer — Setback (Tycones optional)
includes plywood sheeting material, studs, wales and washer.

Coil Penetration: Distance the Lagstud should penetrate the Tyscru coil length plus 13 mm (½"). Tyscru length
General instructions: For extreme penetration or extended concrete curing requirements, the Lagstud or Lagstud
Bolt is normally greased to facilitate removal. To break the bond and permit easy removal, it is a good practice to
turn the lagstud or lagstud bolt a quarter to one-half turn, in and out, eight to twelve hours after the concrete has
been poured.

Coil penetration

Lagstud Bolt length

The minimum Lagstud Bolt length required is equal to the sum of the flat washer, Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102
waler studs, form ply, set back and the coil length plus 13 mm (½"). and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart.

44 45
TYSCRU TYSCRU

Tyscru Standard Tyscru

2-Strut Nominal Diameter Safe Load PLASTIC TYCONE SET BACK The AR Standard 2-Strut Tyscru is available in 13 mm,
mm (in) Tyscru Type kN (lbs) 20 mm and 25 mm (½", ¾" and 1") nominal diameters and may
13 mm (½") 4.5M 20 kN (4,500 lbs) 25 mm or 38 mm or 50 mm (1" or 1½" or 2")
be fabricated to required length to the nearest 3 mm (1/8").
The AR Standard 4-Strut Tyscru is available in 20 mm,
13 mm (½") 6.75M 30 kN (6,750 lbs) 25 mm or 38 mm or 50 mm (1" or 1½" or 2")
25 mm and 32 mm (¾", 1" and 1¼") nominal diameters and
13 mm (½") 9.0M 40 kN (9,000 lbs) 25 mm or 38 mm or 50 mm (1" or 1½" or 2") 2-Strut
may be fabricated to required length to the nearest 3 mm (1/8").
20 mm (¾") 9M 40 kN (9,000 lbs) 25 mm or 50 mm (1" or 2")
25 mm (1") 13.5M 60 kN (13,500 lbs) 25 mm or 50 mm (1" or 2")
SWL is based on an approximate 2:1 Factor of Safety To order, please specify
the following information
EXAMPLE
Name ........................ Standard Tyscru
APPROXIMATE SAFE
4-Strut
4-Strut Nominal Diameter Safe Load PLASTIC TYCONE SET BACK Type ............................. 2-strut 4.5M WORKING LOAD
mm (in) Tyscru Type kN (lbs) Nominal Diameter .......... 13 mm (½") see table on page 51
Tyscru length ............. 560 mm (22") Lagstud Washer
*13 mm (½") 9M 40 kN (9,000 lbs) 25 mm or 38 mm or 50 mm (1" or 1½" or 2")
Strength .............. 20 kN (4,500 lbs.) 2:1 Safety Factor Bolt
20 mm (¾") 18M 80 kN (18,000 lbs) 25 mm or 50 mm (1" or 2")
TYSCRU

TYSCRU
Quantity ....................................... 100
25 mm (1") 18M 80 kN (18,000 lbs) 25 mm or 50 mm (1" or 2")
25 mm (1") 27M 120 kN (27,000 lbs) 25 mm or 50 mm (1" or 2")
25 mm (1") 37M 165 kN (37,000 lbs) 25 mm or 50 mm (1" or 2")
32 mm (1 1/4") 27M 120 kN (27,000 lbs) 25 mm or 50 mm (1" or 2")
4 Strut
32 mm (1 1/4") 37M 165 kN (37,000 lbs) 25 mm or 50 mm (1" or 2") Tyscru
4-Strut - Refer to page XX for details about the 6-Strut Tyscru
*Available as a special order.
SWL is based on an approximate 2:1 Factor of Safety
Cone-Tight Tyscru

The AR Cone-Tight Tyscru has the same capacities as the


Minimum Sizes of Tyscrus Standard 2-Strut and 4-Strut Tyscru and is available in 13 mm,
Description Standard Cone-Tight
20 mm, 25 mm and 32 mm (½", ¾", 1" and 1¼") nominal
Standard Cone-Tight diameters in a minimum length of 100 mm (4"). Cone-Tight
Tyscru Diameter Waterseal Waterseal
Tycones are readily attached to the protruding coils. For coil
13 mm (½") T2-4.5M 100 mm (4") 100 mm (4") 150 mm (6") 150 mm (6")
protrusion lengths see table below.
13 mm (½") T2-6.7M 100 mm (4") 100 mm (4") 150 mm (6") 150 mm (6") 2-Strut
20 mm (¾") T2-7.6M 100 mm (4") 150 mm (6") 150 mm (6") 200 mm (8")
20 mm (¾") T2-9M 100 mm (4") 150 mm (6") 150 mm (6") 200 mm (8")
APPROXIMATE SAFE
To order, please specify
25 mm (1") T2-13.5M 150 mm (6") 150 mm (6") 200 mm (8") 200 mm (8") the following information WORKING LOAD
25 mm (1") T4-18M 150 mm (6") 150 mm (6") 200 mm (8") 200 mm (8") EXAMPLE see table on page 51
20 mm (¾") T4-18M 150 mm (6") 150 mm (6") 200 mm (8") 200 mm (8") Name .................... Cone-Tight Tyscru 2:1 Safety Factor
Type .............................. 4-strut 18M 4-Strut
25 mm (1") T4-27M 150 mm (6") 150 mm (6") 250 mm (10") 300 mm (12")
Nominal Diameter .......... 20 mm (3/4") Diameter Coil Protrusion
25 mm (1") T4-37M 200 mm (8") 150 mm (6") 250 mm (10") 300 mm (12")
Tyscru length .............. 300 mm (12") Lagstud Washer
32 mm (1¼") T4-27M 150 mm (6") 150 mm (6") 250 mm (10") 300 mm (12") 13 mm (½") 10 mm (3/8")
Strength .............. 40 kN (9,000 lbs.)
20 mm (¾") 13 mm (½") Tycones
32 mm (1¼") T4-37M 200 mm (8") 200 mm (8") 250 mm (10") 300 mm (12") Quantity ..................................... 100
25 mm (1") 13 mm(½")
32 mm (1¼") 13 mm (½")

Cone-Tight
2 Strut Tyscru

The minimum Lagstud Bolt length required is equal to the sum of the flat washer, waler studs, form ply, Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102
set back and the coil length plus 13 mm (½"). and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart.

46 47
TYSCRU TYSCRU

Waterseal Tyscru Heavy Tyscru (4-Strut and 6-Strut)

The AR Waterseal Tyscru has the same capacity as the standard The AR 6-Strut Heavy Tyscru is available in 32 mm and 4-Strut
2-Strut and 4-Strut Tyscru. The Waterseal Tyscru is available as 38 mm (1¼" and 1½") nominal diameter and may be
standard or cone tight in 13 mm, 20 mm, 25 mm and 32 mm (½", fabricated to required lengths to the nearest 3 mm (1/8").
¾", 1" and 1¼") nominal diameters in a minimum length of 100 mm 2-Strut
The AR 6-Strut Heavy Tyscru is available as a standard or
(4") for a Cone-Tight Tyscru and 150 mm (6") for a Waterseal Tyscru. water seal Tyscru for both diameters. A 32mm (1¼") Cone
AR uses a unique manufacturing process to fuse a water stop plastic Tight 6-strut Heavy Tyscru is also available.
washer to each wire strut. The plastic washer will break the surface
continuity and prevent seepage of water along the struts.
APPROXIMATE SAFE
APPROXIMATE SAFE 4-Strut WORKING LOAD
To order, please specify the following information
WORKING LOAD see table on page 51 6-Strut
EXAMPLE
Name ......................................... Waterseal Tyscru see table on page 42 2:1 Safety Factor
Type .............................................. 2-strut 6.75M 2:1 Safety Factor
Nominal Diameter .............................. 13 mm (½")
Washer
Tyscru length ................................. 250 mm (22") Tycones To order, please specify
Lagstud
Strength .................................... 20 kN (4,500 lbs.)
TYSCRU

TYSCRU
the following information
Quantity ........................................................ 200
EXAMPLE
Name .............................. 4-Strut Heavy Tyscru
Diameter ....................................... 20 mm (3/4") 4-STRUT 6-STRUT
Length ....................................... 300 mm (12")
Diameter Safe Load Diameter Safe Load
Waterseal Strength ................................ 40 kN (9,000 lbs.) Type
Tyscru mm (in) kN (lbs) mm (in) kN (lbs)
Quantity ..................................................... 100
Adjustable Tyscru *13 mm (½") 9M 40 kN (9,000 lbs) 32 mm (1¼”) 200 kN (45,000 lbs)
Name .............................. 6-Strut Heavy Tyscru 20 mm (¾") 18 M 80 kN (18,000 lbs) 38 mm (1½") 245 kN (55,000 lbs)
Diameter ....................................... 32 mm (1") 25 mm (1") 18 M 80 kN (18,000 lbs)
The AR Adjustable Tyscru, consisting of two Tyscrus (cone tight one end) and one 25 mm (1") 27 M 120 kN (27,000 lbs)
Length ....................................... 300 mm (12")
Continuous Threaded Lagstud, is available in 13 mm, 20 mm, 25 mm and 32 mm Strength ........................... 165 kN (37,000 lbs.) 25 mm (1") 37 M 165 kN (37,000 lbs)
diameters (½", ¾", 1" and 1¼") diameters. Quantity ..................................................... 200 32 mm (1¼") 27 M 120 kN (27,000 lbs)
32 mm (1¼") 37 M 165 kN (37,000 lbs)
APPROXIMATE SAFE
To order, please specify the following information
EXAMPLE
WORKING LOAD
Name ......................................... Adjustable Tyscru see table on page 51
Type ............................................... 2-strut 4.5M 2:1 Safety Factor
Nominal Diameter .............................. 13 mm (1/2")
Length ............................................... 225 mm (9")
Strength ..................................... 30 kN (6,750 lbs.)
Quantity ......................................................... 200 Lagstud

Washer

Adjustable Tyscru

48 49
TYSCRU TYSCRU

Ty-Anchor (2-Strut and 4-Strut) Safe Working Load

The AR Ty-Anchor is probably the most common re-anchorage STRENGTH OF LAGSTUD


device used. It has been the workhorse of the industry and well
proven through the years. It is well suited to use even in the very ½" mild ½" high ¾" high ¾" high 1" mild 1" mild 1" high 1" high 1¼" mild 1¼" high
steel tensile tensile tensile steel steel tensile tensile steel tensile*
low strength concretes. See the appendix for estimated working
(60,000 lbs)
and ultimate load ratings in various concrete strengths.
Lag Stud Safe Working Load 7 60,000 lbs (265 kN)
½" mild steel 33 kN (7,000 lbs)
APPROXIMATE SAFE ½" high tensile 40 kN (9,000 lbs) (55,000 lbs)
½" high tensile 80 kN (18,000 lbs)
WORKING LOAD 1" mild steel 110 kN (25,000 lbs)
see table on page 51 1" high tensile
1¼" mild steel
167 kN (37,500 lbs)
165 kN (37,000 lbs) (50,000 lbs)

2:1 Safety Factor 1¼" high tensile* 265 kN (60,000 lbs)*


*Use double nuts to obtain full capacity of Rod.
(45,000 lbs)

To order, please specify the following information


EXAMPLE
2-Strut 4-Strut 178 kN (40,000 lbs)
TYSCRU

TYSCRU
Name ................................................... Ty-Anchor 5 37,500 lbs (167 kN) 6 37,000 lbs (165 kN)
Type .......................................................... 2-Strut
Diameter .............................................. 25 mm (1") (35,000 lbs)
Length .............................................. 300 mm (12")
Quantity .......................................................... 200
133.5 kN (30,000 lbs)

4 25,000 lbs (110 kN)


(25,000 lbs)
Diameter Strut Length “L” Set back “S” IT IA C*

25 mm (1”) 2 300 mm (12") 185 mm (7¼") 165 mm (6½") 20 mm (¾")


32 mm (1¼”) 2 or 4 380 mm (15") 195 mm (7¾") 175 mm (7") 20 mm (¾") 89 kN 3 18,000 lbs (80 kN) (20,000 lbs)
32 mm (1¼”) 2 or 4 450 mm (17½") 100 mm (4") 195 mm (7¾") 175 mm (7") 20 mm (¾")
32 mm (1¼”) 2 or 4 500 mm (20") 195 mm (7¾") 175 mm (7") 20 mm (¾")
38 mm (1½") 2 or 6 600 mm (24") 215 mm (8½") 190 mm (7½”) 25 mm (1") (15,000 lbs)

*Set back can be increased for greater strength. **Clearance between setting bolt and final bolt.
2 9,000 lbs (40 kN)
44.5 kN (10,000 lbs)
APPROXIMATE ULTIMATE CAPACITIES 1 7,000 lbs (33 kN)
S L
Diameter (5,000 lbs)
Strut Type kN (lbs)
mm (in)

Loads
4,500 lbs 6,750 lbs 9,000 lbs 18,000 lbs 13,500 lbs 18,000 lbs 27,000 lbs 37,000 lbs 27,000 lbs 37,000 lbs
25 mm (1”) 2- Strut 15 M 67 kN (15,000 lds) (20 kN) (30 kN) (40 kN) (80 kN) (60 kN) (80 kN) (120 kN) (165 kN) (120 kN) (165 kN)
32 mm (1¼”) 2- Strut 15 M 67 kN (15,000 lds)
½" 2-strut ½" 2-strut ¾" 2-strut ¾" 4-strut 1" 2-strut 1" 4-strut 1" 4-strut 1" 4-strut 1¼" 4-strut 1¼" 4-strut
32 mm (1¼”) 2- Strut 40 M 178 kN (40,000 lds)
32 mm (1¼”) 4- Strut 60 M 265 kN (60,000 lds)
38 mm (1½") 4- Strut 60 M 265 kN (60,000 lds)
38 mm (1½") 6- Strut 90 M 400 kN (90,000 lds)
A
Grip l - Embedment

Final Lagstud length C**

T
Grip l - Embedment

Setting Lagstud length

Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102
various concrete strengths table on pages 51 and 112 of the Appendix. and typical Medium and Heavy Formwork beginning on page 108.

50 51
TYSCRU TYSCRU
ACCESSORIES ACCESSORIES

Ty-Frame Tybow Anchor (2-strut, 4-strut and 6-strut)

The AR Standard Ty-frame consists of four coils The AR Tybow Anchor combines the advantages of the Tyscru
welded to a truss-like arrangement of wire coil with the efficiency of the bow shaped continuous threaded
struts with a leg at the front face extending struts to make a highly effective anchorage device. Used with 10½"
down to the soffit, for support of the riser form. lagstud bolts or He-Bolts, the Ty-Bow is applicable even in
Ty-frames are designed for the individual riser the lowest concrete strengths. See the appendix for estimated
and seat bracket condition. Standard working and ultimate load ratings in various concrete strengths.
Ty-Frame

TOP OF LIFT

2-Strut
6"
S L
The AR Alternate Ty-frame may be supplied
in its alternate form, at our discretion, if job
conditions warrant. This alternate form consists 4-Strut
of a series of Tyloops, or Tyloops and Tyscru, C*
welded to a strong vertical support member.
Alternate C*
Ty-Frame
ACCESSORIES

ACCESSORIES
A
Grip l
TYSCRU

TYSCRU
Final Lagstud length

Grip lT Continuous Final penetration


Lagstud
Setting length Setting Lagstud penetration
6-Strut

The AR Fill Type Ty-frame is made to fit the


job condition where the riser is poured on APPROXIMATE SAFE WORKING LOADS
fill. Usually manufactured in multiple units to Fill Type Ty-Frame 2:1 Safety Factor
support 2, 3, or 4 seat brackets with one unit.

Anchor Safe Working Load


Diameter Length “L” Set back “S” IT IA C*
Type kN (lbs)
2-Strut 20 mm, 25 mm, 32 mm 450 mm (18") 195 mm (7¾") 175 mm (7") 20 mm (¾") 67 kN (15,000 lbs)
(¾”, 1”, 1¼”)
4-Strut 25 mm, 32 mm 450 mm (18") 100 mm (4") 222 mm (8 3/8") 190 mm (7½") 32 mm (1¼") 134 kN (30,000 lbs)
(1”, 1¼”) 610 mm (24 3/8")
6-Strut 38 mm (1½") 600 mm (24") 230 mm (9") 190 mm (7½”) 38 mm (1½”) 200 kN (45,000 lbs)
The AR Sloping Slab Ty-frame consists of *Clearance between setting bolt and final bolt. Other sizes available upon request.
Tyscrus welded together in exact positions to
Sloping Slab
support the riser form.
Ty-Frame
To order, please specify
To order, please specify the following information
the following information EXAMPLE
EXAMPLE Name ........................................ Tybow Anchor
Name ........................ Alternate Ty-Frame Type ..................................................... 2-Strut
Supply a sketch or complete details of Diameter ................................... 32 mm (11/4")
risers and seat bracket Length ...................................... 450 mm (18")
Quantity ............................................ 200 Quantity .................................................... 200

Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102 Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for
and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart. various concrete strengths table on pages 51 and 112 of the Appendix.

52 53
TYSCRU TYSCRU
ACCESSORIES ACCESSORIES

Lagnut Coil Nuts

AR Lagnuts are manufactured with Lag thread and are available in ½” through 1½” (13 mm AR Coil Nuts Two standard coil nuts of each size equal the strength of AC
through 38 mm) diameters. Warning: when utilizing Lagnuts on through-Ty applications, one heavy duty tall coil nut of the same size. D
such as Continuous Threaded Lagstud, double nuts are required to develop ultimate
loads for 1¼” (32 mm) applications. For all other applications, AR Lagnuts are designed to APPROXIMATE SAFE WORKING LOADS
develop the full published ultimate load of AR Lagstud.
2:1 Safety Factor
APPROXIMATE SAFE WORKING LOADS APPROXIMATE SAFE H
D H AC Box Weight per 100pcs
2:1 Safety Factor Size Size Across Flats Qty lbs
WORKING LOAD
lbs
Diameter SAFE WORKING LOADS Lagnut
1/2” 0.484 0.863 500 6.2 6,000
in (mm) lbs (kN)
5/8" Finished 0.547 0.930 500 11.4 8,000
½ (13) 9,000 (40) 3/4" Finished 0.641 1.107 500 11.4 9,000
¾ (20) 18,000 (80) 3/4" Heavy 0.734 1.231 250 17.8 9,000
1 (25) 37,500 (167) 7/8" 0.859 1.416 250 27.6 16,000
1¼ (32) 49,000* (216)* Lagstud 1" 0.984 1.600 150 15.0 18,000
Tyscru
1½ (38) NCA Technical Department for details. 1-1/4" 1.219 2.123 70 75.2 27,000
1-1/2" 1.469 2.682 40 122.6 40,000
To order, please specify the following information
ACCESSORIES

ACCESSORIES
TYSCRU

TYSCRU
EXAMPLE
Name ......................................................... Lagnut
Diameter .............................................. 25 mm (1”) Wing Nut
Quantity .......................................................... 200

*When using 1¼” (32 mm) High Tensile Lagstud, use double nuts to obtain full capacity of Rod, 60,000 lbs (265 kN). AR Wing Nuts are manufactured with a lag thread and are used
with AR She-Bolts or Taper-Tys. Fabricated in 20 mm, 25 mm and
32 mm (¾”, 1” and 1¼”) diameters.
Handle Lagnut

AR Handle Lagnuts are made of hex nuts welded to substantial wire loops.
Available in ½”, ¾”, 1” and 1¼” (13 mm, 20 mm, 25 mm and 32 mm)
diameters with lag thread. The handle eliminates the need for using a
wrench and makes installation and/or stripping fast and simple.

APPROXIMATE SAFE WORKING LOADS Size Ultimate Tensile Load


2:1 Safety Factor in (mm) lbs (kN) To order, please specify
the following information
3
/4 (20) 40,000 (178)
Bolt Diameter Threads per Handle length Safe Working Load EXAMPLE
in (mm) inch (TPI) from nut centre lbs (kN) 1 (25) 82,000 (365) Name .................................. Wing Nut
in (mm) Quantity ........................... 25 mm (1")
½ (13) 6 5 (125) 9,000 (40) 11/4 (32) 115,000 (512)
¾ (20) 4½ 47/8 (120) 18,000 (80) Wing Nut
1 (25) 3½ 5½ (140) 37,500 (167)
1¼ (32) 3½ 83/8 (210) 57,500 (256) Lagstud Bolt
1½ (38) Contact the AR Technical Department for details. Washer Bulkhead
Form

To order, please specify the following information


EXAMPLE
Name ............................................. Handle Lagnut
Diameter ............................................. 13 mm (½”)
Quantity .......................................................... 200
Handle Lagnut

54 55
TYSCRU TYSCRU
ACCESSORIES ACCESSORIES

Flat Washer Batter Washer

AR Flat Washers are made from flat steel plate. For optimization, AR Washers are square. For best results the AR Batter Washers are designed to hold a lagstud at any angle up to 45°
washer should be placed so that its length runs parallel to the walers and the gap or space spanned by the washer without need for wedging. Nail holes are provided for attaching the washers
should not exceed the physical bolt diameter plus 1/4” (6 mm). to the walers or strongbacks. Multiple lumber grips on the underside prevent
slippage when the washers are not nailed. Available for all lagstud sizes.
Lagstud
Bolt Diameter Washer Dimensions Washer Height
mm (in) mm (in) mm (in)
13 mm (½") 89 mm x 89 mm (3½" x 3½") 25 mm (1")
22 mm (7/8 ") 125 mm x 140 mm (5" x 5½") 36 mm (17/16 ")
25 mm (1") 165 mm x 165 mm (6½" x 6½") 41 mm (15/8 ")
29 mm (11 /8 ") 165 mm x 165 mm (6½" x 6½") 39 mm (19/16 ")
35 mm (13 /8 ") 170 mm x 170 mm (6¾" x 6¾") 45 mm (1¾")
Washer 38 mm (1½") 175 mm x 175 mm (7" x 7") 45 mm (1¾")
41 mm (15 /8 ") 175 mm x 175 mm (7" x 7") 45 mm (1¾")

Bolt Diameter Plate Size Hole Size Lagstud


in (mm) in (mm) in (mm) Batter To order, please specify
Lagstud
½ (13) 3¾ x 3¾ x ¼ (95 x 95 x 6 ) 9
/16 " (14 mm) Washer the following information
ACCESSORIES

ACCESSORIES
(20) 5 x 5 x 3/8 (125 x 125 x 10) (21 mm)
TYSCRU

TYSCRU
¾ 13
/16 " EXAMPLE
¾ (20) 6x6x½ (150 x 150 x 13) 13
/16 " (21 mm) Name .......................................... Batter Washer
1 (25) 5 x 5 x 3/8 (150 x 150 x 10) 11 /16 " (27 mm) Diameter .......................................... 20 mm (3/4”)
Washer
1 (25) 6x6x½ (150 x 150 x 13) 11 /16 " (27 mm) Quantity ....................................................... 200
1¼ (32) 6x6x½ (150 x 150 x 13) 1 3 /8 " (35 mm)
1¼ (32) 8x8x¾ (200 x 200 x 19) 1 3 /8 " (35 mm)
1½ (38) Contact AR Technical Department for details.
Tyscru

Washer
Bolt Plate DISTANCE BETWEEN WALER
Dia. Size 1" 1¼" 1½" 1¾" 2" 2¼" 2½" 2¾" 3" 3¼"
(½”) (3¾” x 3¾” x ¼”) 6,750 lbs 3,750 lbs 2,500 lbs 1,900 lbs 1,600 lbs 1,100 lbs Lag Thread Coupler
(¾”) (5” x 5” x 3/8 “) 25,000 lbs 14,000 lbs 9,000 lbs 7,000 lbs 5,600 lbs 4,000 lbs
(¾”) (6” x 6” x ½”) 60,000 lbs 33,000 lbs 22,000 lbs 16,000 lbs 13,500 lbs 9,600 lbs
(1”) (5” x 5” x 3/8”) 38,000 lbs 38,000 lbs 24,000 lbs 18,000 lbs 14,000 lbs 10,000 lbs AR Lag Thread Couplers are used to couple two Lag Rods of the same diameter.
(1”) (6” x 6” x ½”) 38,000 lbs 38,000 lbs 24,000 lbs 18,000 lbs 14,000 lbs 10,000 lbs The Lag Thread Coupler is used with lag thread systems and is manufactured with
(1¼”) (6” x 6” x ½”) 37,000 lbs 37,000 lbs 27,000 lbs 19,000 lbs 15,000 lbs 10,000 lbs a positive stop.
(1¼”) (8” x 8” x ¾”) 125,000 lbs 125,000 lbs 91,000 lbs 65,000 lbs 50,000 lbs 35,000 lbs
(1½”) Contact AR Technical Department for details.
APPROXIMATE SAFE
WORKING LOADS 2:1
Rod Diameter Outside Diameter Overall Length Type kN (lbs)
Bolt Plate Diameter DISTANCE BETWEEN WALER 13 mm (½") 20 mm (¾") 50 mm (2") 9M 40 kN 9,000 lbs
Size (mm) 25 mm 32 mm 35 mm 45 mm 50 mm 57 mm 63 mm 70 mm 75 mm 82 mm 20 mm (¾") 30 mm (11/8") 75 mm (3") 18M 80 kN 18,000 lbs
13 95 x 95x 6 30 kN 16 kN 11 kN 8.5 kN 7.1 kN 4.9 kN 25 mm (1") 38 mm (1½") 100 mm (4") 37.5M 167 kN 37,500 lbs
20 125 x 125 x 10 111 kN 62 kN 40 kN 31 kN 25 kN 18 kN
20 150 x 150 x 13 266 kN 146 kN 98 kN 71 kN 60 kN 43 kN
25 125 x 125 x 10 169 kN 169 kN 106 kN 80 kN 62 kN 45 kN To order, please specify
25 150 x 150 x 13 169 kN 169 kN 106 kN 80 kN 62 kN 45 kN the following information
32 150 x 150 x 13 165 kN 165 kN 120 kN 85 kN 66 kN 45 kN EXAMPLE
32 200 x 200 x 19 555 kN 555 kN 405 kN 290 kN 220 kN 155 kN Name ....................... Lag Thread Coupler
38 Contact AR Technical Department for details. Rod diameter ........................ 20 mm (3/4”)
System load reduction from increased waler spacing. Quantity ........................................... 200

Consult your AR Area Sales Representative or the AR Technical Department for additional information.

56 57
TYSCRU TYSCRU
ACCESSORIES ACCESSORIES

Plastic Cone-Tight Tycone Cone Removal Wrench (T-Shape and L-Shape)

AR Plastic Cone-Tight Tycones are designed to engage the protruding The AR Cone Removal Wrenches are designed to remove the Plastic
Cone-Tight
coil of a Cone-Tight Tyscru. Actual lengths are greater than the set back plastic cones from Cone Tight Tyscrus. Available for 13 mm, Tycone
requirement. See accompanying chart for dimensions. 20 mm, 25 mm and 32 mm (½", ¾", 1" and 1¼") diameter cones.

Washer Dimensions
Wrench Type
Batter mm (in)
Lagstud T-Shape Cone
Washer T-Shape 13 mm, 20 mm (½" x 3/4") Removal Wrench
L-Shape 25 mm, 32 mm (1" x 11/4")

To order, please specify the following information


EXAMPLE To order, please specify
Name ............................. Plastic Cone-Tight Tycone the following information
Nominal Diameter ............................... 20 mm (3/4”) T-Shape Cone
Tyscru EXAMPLE Removal Wrench
Set back .............................................. 25 mm (1”)
Name ..................... Cone Removal Wrench
Quantity ........................................................... 200
Washer Type ............................................ T-Shape Plastic
Diameter .................................. 20 mm (3/4”) Cone-Tight
Tycone
Quantity ................................................... 2
Tyscru Diameter Set back Nominal Diameter and Depth Taper
mm (in) mm (in) mm (in) mm (in)
ACCESSORIES

ACCESSORIES
TYSCRU

TYSCRU
13 mm (½") 25 mm (1") 13 mm x 35 mm (½" x 13/8")
13 mm (½") 38 mm (1½") 13 mm x 48 mm (½" x 17/8") 25 mm to 32 mm (1" to 1¼") Lag Wrench
13 mm (½") 50 mm (2") 13 mm x 60 mm (½" x 23/8")
20 mm (¾") 25 mm (1") 20 mm x 38 mm (¾" x 1½")
38 mm to 45 mm (17/16 to 111/16")
20 mm (¾") 50 mm (2") 20 mm x 61 mm (¾" x 23/8") The AR Lag Wrench is designed for tightening and removing of AR lag
25 mm (1") 25 mm (1") 25 mm x 38 mm (1" x 1½") bolts when constructing the formwork assembly. The Lag Wrench solid
48 mm to 54 mm (1 7/8" to 2 1/8")
25 mm (1") 50 mm (2") 25 mm x 61 mm (1" x 2 3/8")
25 mm (1") diameter L-shape steel construction is equipped with a
32 mm (1¼") 25 mm (1") 32 mm x 38 mm (1¼" x 1½")
57 mm to 61 mm (2¼" to 2 3/8") 300 mm (12") round handle and a 140 mm (5½") 90°radius. The Lag
32 mm (1¼") 50 mm (2") 32 mm x 61 mm (1" x 2 3/8")
Wrench is supplied as a complete unit: handle and socket. Available
for 13 mm, 20 mm, 25 mm and 32 mm (½", ¾", 1" and 1¼") bolt size.

Plastic Set Back Tyscru Plug To order, please specify


the following information
AR Plastic Set Back Tyscru Plugs are designed to provide an easy and economical EXAMPLE
Name ................................. Lag Wrench
means of sealing 13 mm, 20 mm and 25 mm (½", ¾" and 1") diameter Tycone
Rod diameter ........................ 25 mm (1”)
holes at a required set back. While providing an interesting architectural effect. Quantity ............................................... 1
The Plastic Set Back Tyscru Plugs are available in light gray. Other colours are
available on special order. The plugs may be used in exterior and/or interior
applications. Additional sealing or caulking is optional.
Plastic Coil Setting Plug

Tyscru Plug Diameter Tycone Set Back Approximate Recess


To order, please specify The AR Lag Wrench is designed for tightening and removing of AR lag bolts
mm (in) mm (in) mm (in)
the following information "S" Recess when constructing the formwork assembly. The Lag Wrench solid 25 mm (1")
25 mm (1") 13 mm (½")
EXAMPLE
diameter L-shape steel construction is equipped with a 300 mm (12") round
13 mm (½") 38 mm (1½") 16 mm (5/8 ") handle and a 140 mm (5½") 90°radius. The Lag Wrench is supplied as a
50 mm (2") 20 mm (¾")
Name ......... Plastic Set Back Tyscru Plug
Nominal diameter ................ 13 mm (1/2”) complete unit: handle and socket. Available for 13 mm, 20 mm, 25 mm and
25 mm (1") 16 mm (5/8 ")
20 mm (¾") Colour ..................................... light gray 32 mm (½", ¾", 1" and 1¼") bolt size.
50 mm (2") 32 mm (1¼")
Quantity ........................................... 200
25 mm (1") 6 mm (¼")
25 mm (1") (3 /8 ")
50 mm (2") 10 mm Tyscru

Optional Plastic
Consult your AR Area Sales Representative Sealing Set-Back Plug Consult your AR Area Sales Representative
or the AR Technical Department for additional information. or the AR Technical Department for additional information.

58 59
TYLOOP TYLOOP

Tyloop (2-Strut) Flared 4-Strut Tyloop (TL4)

The AR Standard 2-Strut Tyloop (TL-2) is made of a single looped wire welded to a helix coil in The AR Flared 4-Strut Tyloop is made with two looped wires welded to a helix coil.
13 mm and 20 mm (½" and ¾") nominal diameters. Suitable for light anchorage requirements Suitable for heavy form anchorage in mass concrete construction. The standard length
or as emergency tie, tie down, corner tie, etc. Standard length is 100 mm (4") for 13 mm (½") is 380 mm (15") for 25 mm (1") and 32 mm (1¼") diameters with struts flaring to 75 mm
diameter and 150 mm (6") for 20 mm (¾") diameters. This unit may be fabricated in lengths to (3") diameters. The standard flare unit is supplied unless special size or shaped flares
suit the job site requirements. are requested.
The AR Heavy 2-Strut Tyloop (TL-2-H) is made with heavier wire and are principally used as
anchors for medium heavy construction. The standard length is 150 mm (6") for both 13mm (½")
Sizes
and 20 mm (¾") diameter. The Tyloop can also be fabricated in longer lengths.
LAG inch (mm)
TL4F ½” - 6” (13 - 150)
Tie Application
Standard ¾” - 9” (20 - 225)
2 Strut
Tyloop Heavy 1” - 12” (25 - 300)
Lagstud 2 Strut 1¼” - 15” (32 - 380)
Bolt Tyloop
TWF

Heavy 4-Strut Offset Flared Tyloop (TL4-H)


Washer
Lagstud
Washer
Bolt The AR Offset Flared 4-Strut Tyloop is made of two looped wires welded to a helix coil.
The loops are flared and offset so that the center of anchorage is below the center line
TYLOOP

TYLOOP
of the coil to distribute the load well into the concrete and still keep the coil at or near the
To order, please specify APPROXIMATE SAFE WORKING LOADS 2:1 top of the pour or other boundary restrictions.
the following information Also available as a Cone-Tight and Ferrule Tyloop LAG
EXAMPLE
Name .......................... Tyloop (2-Strut) (TL-2-H) Inside radius “C”
Safe Working Load Sizes
Type Size
kN (lbs) inch (mm)
Type ................................................... Heavy 9M
Nominal Diameter ............................ 20 mm (3/4”) 4.5M ½" Tyloop 13 mm x 102 mm (½" x 4") 20 mm (¾") 22.3 kN (4,500 lbs) 1 x 15 (25 x 380)
Length ........................................... 150 mm (6") 9M ½" Heavy Tyloop 13 mm x 152 mm (½" x 6") 20 mm (¾") 40 kN (9,000 lbs)
TWF 1¼ x 18 (32 x 460)
9M ¾" Tyloop 20 mm x 152 mm (¾" x 6") 29 mm (1 1 /8 ") 40 kN (9,000 lbs)
Coil type ............................................ Cone Tight
12M ¾" Heavy Tyloop 20 mm x 152 mm (¾" x 6") 29 mm (1 1 /8 ") 53.4 kN (12,000 lbs)
TLO4F Other sizes available
Quantity ....................................................... 200
APPROXIMATE SAFE WORKING LOADS 4:1

Flared 2-Strut Tyloop (TL2F) APPROXIMATE WORKING LOADS FOR TYLOOPS


As an Anchor**
Size and Type * As Tie Tension Shear***
AR 2 Strut Flared Tyloops are made with the loop end flared for greater anchorage in the inch (mm) lbs (kN) lbs (kN)
lbs (kN)
concrete. Standard lengths are 9” (230 mm) for 1/2” (13 mm) diameter and 12” (305 mm)
for 3/4” (20 mm) diameter. Can be supplied in special lengths and flares to order. TL2 ½ ” x 4” Standard Tyloop (13 x 100) 1,900 (8.5) 1,125 (5.0) 750 (3.5)
TO ORDER, give nominal diameter, by length, symbol and name. Example: - 1/2” x 9” TL2 ¾ ” x 6” Standard Tyloop (20 x 150) 3,900 (17.5) 2,250 (10.0) 1,500 (7.0)
(13 mm x 230 mm) TL2F 2 Strut Flared Tyloop. TL2-H ¾ ” x 6” Heavy Tyloop (20 x 150) 5,200 (23.0) 2,625 (12.5) 1,875 (8.3)
TL2F ½ ” x 9” Flared Tyloop (13 x 230) — 2,250 (10.0) 750 (3.5)
TL2F ¾ ” x 12” Flared Tyloop (20 x 305) — 3,375 (15.0) 1,875 (8.3)

LAG
TL2F TL4F 1” x 15” Flared 4-Strut (25 x 380) — 6,000 (26.5) 3,375 (15.0)
TL4F 1¼” x 15” Flared 4-Strut (32 x 380) — 6,750 (30.0) 4,500 (20.0)

TWF
Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for
various concrete strengths table on pages 51 and 112 of the Appendix.

60 61
TYLOOP TYLOOP

Flared 6-Strut Tyloop Tyback Tyloop

The AR Flared 6-Strut Tyloop is made with three wires welded to a helix coil. The AR Tyback Tyloop is fabricated with two looped wires welded to a helix coil. The
The three loops are flared to provide greater anchorage in concrete. Tyback Tyloop is specially designed to tie into existing reinforcing bars to form bulkheads
and for dam construction. Available as a 20 mm x 215 mm (¾" x 8½") standard size, the
AR Tyback Tyloop can be custom fabricated to meet job site conditions.
STANDARD HEAVY
APPROXIMATE SAFE APPROXIMATE SAFE To order, please specify
WORKING LOAD WORKING LOAD the following information APPROXIMATE SAFE
207 kN (46,500 lbs) 275 kN (61,800 lbs) EXAMPLE WORKING LOAD
2:1 Safety Factor 2:1 Safety Factor Name ....................................... Tyback Tyloop 80 kN (18,000 lbs)
Diameter ..................................... 20 mm (3/4”) 2:1 Safety Factor
Quantity .................................................... 200
Flared 6-Strut Tyloop
Diameter Length Flare
32 mm (1¼") 380 mm (15") 170 mm (6¾")
38 mm (1½")
Edge condition limitations will govern.
Contact the AR Technical Department for further details.
Other configurations and designs are available.
Coil Length

Flared 2-Strut Standard Tyloop


TYLOOP

TYLOOP
Reinforcing Tyloop
Dowel Diameter Ultimate Strength Coil Length
Washer
Lagstud Including Penetration
Lagstud
2-Strut 13 mm (½") 44.5 kN (10,000 lbs) 40 mm (1½")
Tyloop
13 mm (½") 80.0 kN (18,000 lbs) 50 mm (2")
20 mm (¾") 80.0 kN (18,000 lbs) 50 mm (2")
20 mm (¾") 106.0 kN (24,000 lbs) 60 mm (2 3 /8 ")

Washer Washer
Flared Single and Double Flared Tyloop
Diameter Ultimate Strength Coil Length
Including Penetration Minimum coil penetration
13 mm (½") 80 kN (18,000 lbs) 55 mm (2 1 /8 ")
Offset Flared
20 mm (¾") 106 kN (24,000 lbs) 50 mm (2")
Flared 4-Strut Tyloop 25 mm (1") 133 kN (30,000 lbs) 60 mm (23 /8 ")
Lagstud 4-Strut Tyloop
Bolt
Lagstud 25 mm (1") 213 kN (48,000 lbs) 75 mm (3")
Washer
32 mm (1¼") 267 kN (60,000 lbs) 75 mm (3")

Double Looped Flared Tyloop


Diameter Ultimate Strength Coil Length
Washer Including Penetration
Handle
Lagnut 25 mm (1") 267 kN (60,000 lbs) 75 mm (3")
32 mm (1¼") 267 kN (60,000 lbs) 75 mm (3")

Tybow Anchor
Diameter Ultimate Strength Coil Length
Including Penetration
32 mm (1¼") 80 kN (18,000 lbs) 75 mm (3")
38 mm (1½") 160 kN (36,000 lbs) 75 mm (3")

Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for
various concrete strengths table on pages 51 and 112 of the Appendix. various concrete strengths table on pages 51 and 112 of the Appendix.

62 63
SINGLE SIDED SINGLE SIDED
FORMING FORMING
SYSTEM SYSTEM

Single End Welding Tyscru Toggle Ty

The AR Single End Welding Tyscru is made with 2 struts welded to a coil at one end only, AR Toggle Tys are used to anchor a facing
leaving the open end available for field welding, particularly suitable for heavy and special formwork, back to steel or wood sheet piling
applications. Available in 13 mm, 20 mm and 25 mm (½", ¾" and 1") diameters. and require a 35 mm (13/8") diameter hole
through the sheathing to permit entry of the
To order, please specify the following information Single End toggle. Toggle plate sizes are shown below.
Welding Tyscru
EXAMPLE Hooked
Name ............................ Single End Welding Tyscru Rebar
Lagstud
APPROXIMATE SAFE
Nominal Diameter ............................... 20 mm (1/2”) Bolt WORKING LOADS 2:1
Overall length ..................................... 100 mm (4")
Quantity .......................................................... 200
To order, please specify the following information Toggle Ty
Washer EXAMPLE
Name ................................................................ Toggle Ty
APPROXIMATE SAFE WORKING LOADS Type ....................................................... standard 2.25M 35 mm
(1 3/8")
APPROXIMATE SAFE Diameter ....................................................... 13 mm (½") diameter
Diameter Length Safe Working Load Weld Length hole
Length ....................................................... 380 mm (15")
13 mm (½") 100 mm (4") 16.5 kN (3,750 lbs) 32 mm (1¼") WORKING LOAD Plate size ....... 5 mm x 32 mm x 75 mm (3/16" x 1¼" x 3)
20 mm (¾") 150 mm (6") 30.0 kN (6,750 lbs) 38 mm (1½")
2:1 Safety Factor Quantity ..................................................................... 200
25 mm (1") 250 mm (10") 60.0 kN (13,500 lbs) 50 mm (2")
NOTE: Diameter of rebar will influence Single End Welding Tyscru strength. Toggle Ty

Bent Single End Welding Tyscru


SINGLE SIDED

SINGLE SIDED
FORMING

FORMING
SYSTEM

SYSTEM
The AR Bent Single End Welding Tyscru is made with 2 struts
welded to a coil at one end. The other end of the 2 struts is bent at
90° in opposite directions away from the coil. This allows for field
welding onto sheet piling and H-Pile construction. Available in 13 Handle Lagnut Washer

mm, 20 mm and 25 mm (½", ¾" and 1") diameters and may be Lagstud Bolt
fabricated to the required lengths.
TOGGLE SIZE
To order, please specify Type Safe Load Steel Sheating Wood Sheating
the following information
13 mm (½") Standard 2.25M 10 kN (2,250 lbs) 5 mm x 32 mm x 75 mm ( 3/16 " x 1¼" x 3") 10 mm x 25 mm x 115 mm ( 3/8 " x 1" x 4½")
EXAMPLE APPROXIMATE SAFE 13 mm (½") Heavy 3.75M 17 kN (3,750 lbs) 6 mm x 32 mm x 75 mm (¼" x 1¼" x 3") 10 mm x 25 mm x 115 mm ( 3/8 " x 1" x 4½")
Name ........... Bent Single End Welding Tyscru WORKING LOAD
Nominal Diameter ........................ 13 mm (1/2”) H-Pile
Length (L) .................................... 100 mm (4") 2:1 Safety Factor
Leg depth ..................................... 25 mm (1")
Quantity .................................................... 200 Bent Single End
SWL is based on an approximate 2:1 Factor of Safety Welding Tyscru

APPROXIMATE SAFE WORKING LOADS


Diameter L B Shear
mm (in) mm (in) mm (in) Safe Working Load
13 mm (½") 100 mm (4") 25 mm (1") 22 kN (5,000 lbs)
20 mm (¾") 150 mm (6") 38 mm (1½") 22 kN (5,000 lbs)
25 mm (1") 250 mm (8") 50 mm (2") 44 kN (10,000 lbs)

NOTE: Weld both sides of both struts. Field test should be conducted to
establish actual approximate safe working load. Failure will occur in shear.

Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102 Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102
and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart. and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart.

64 65
SINGLE SIDED SINGLE SIDED
FORMING FORMING
SYSTEM SYSTEM

Angle Ty-Bracket T4 Lag Ty

The AR Angle Ty-Bracket is designed to tie single-sided forming to steel The AR T4 Lag Ty is designed to be welded on structural members for single sided forming. The
piles, metal beams, etc. Brackets are available from 13 mm to 25 mm AR Lag Ty consists of a 20 mm (¾") diameter coil with a 75 mm (3") mild steel lag stud fabricated
(½" to 1") diameters as identified in the table below, with lag thread or can together with a typical 4-strut configuration.
be special ordered with NC thread.
The AR Angle Ty-Bracket allows a full 90° of pivot of the form-tie and will APPROXIMATE SAFE Lagstud
exceed the tensile capacity of the form-tie when correctly installed by a WORKING LOAD Bolt

certified licensed welder. 80 kN (18,000 lbs) H-Pile

2:1 Safety Factor


Earth Taper Ty

To order, please specify


Wood Lagging H-Pile the following information
Height

Inside Dim. “L” EXAMPLE


She Bolt Tie Rod
Name ................................. T4 Lag Ty
Quantity ...................................... 200 H-Pile
45˚ 45˚
Double Wales sized Batter Wing Position B Position B
per load requirements Washer Position A NOTE: Field welding to structural members should
Nut
be performed by a certified licensed welder.

Rock Anchor
H-Pile

AR Rock Anchors are used for anchoring with AR Lagstud or NC Rod in


APPROXIMATE SAFE form tying and anchoring of concrete facings to rock excavation. Available
WORKING LOAD
SINGLE SIDED

SINGLE SIDED
in 13 mm, 20 mm and 25 mm (½", ¾" and 1") diameters.
FORMING

FORMING
SYSTEM

SYSTEM
Swivel
Pin Continuous, 2:1 Safety Factor
full length Rock Anchor
fillet weld Lagstud

Pivot To order, please specify Drill Hole


Diameter
Bracket/ the following information
Angle
EXAMPLE
Ty-Bracket
Name ..................... Single End Welding Tyscru Washer Lagstud Bolt Tyscru Hole Depth
Form-Tie, Form-Ty Diameter ....................... 25 mm (1”)
such as a Quantity .................................................... 100
Taper-Ty, Consult the AR Technical Department
She Bolt, APPROXIMATE SAFE WORKING LOADS 2:1 for other thread patterns, other drill hole
Lagstud, Etc. Note: Performance could vary diameters and higher Approximate Safe
Diameter Drill Hole Diameter Hole Depth (minimum) Safe Working Load* Working Load requirements.
based on the quality of weld.
mm (in) mm (in) mm (in) kN (lbs)
13 mm (½") 35 mm (13 /8 ") 150 mm (6") 20 kN (4,500 lbs)
NOTE: Remove temporary plastic band
20 mm (¾") 45 mm (1¾") 200 mm (8") 40 kN (9,000 lbs)
before installation. The lagstud end must
Warning: To ensure proper engagement (final installation) the Form-tie must extend beyond the swivel 25 mm (1") 45 mm (1¾") 250 mm (10") 80 kN (18,000 lbs) be against back-strap then forced to
pin a minimum of 13 mm (½"). An easy way to accomplish this is to line up the swivel pin and the Formtie *AR recommends that all Rock Anchors be tested under job-site conditions to bottom of bore hole before tightening.
in position A and thread the Form-tie through the swivel pin until it contacts the metal piling. determine if ambient stratum conditions will limit approximate safe working load. Do not overtighten. Overtightening
destroys the bond.
APPROXIMATE SAFE WORKING LOADS
AR Rock Anchor Assembly
Form Tie Diameter Bracket SWL kN (lbs.)
Dim. “L”
mm (in) Position A Position B
Transition couplers give the AR mechanical cone shell anchors the ability
13 mm (½") 115 mm (4½") 40 kN (9,000 lbs) 28 kN (6,300 lbs)
to be used with lagstud or National Course thread, for single sided forming
20 mm (¾") 115 mm (4½") 80 kN (18,000 lbs) 56 kN (12,500 lbs)
25 mm (1") 152 mm (6") 140 kN (31,500 lbs) 98 kN (22,000 lbs)
applications.
Refer to AR’s Rock Anchoring and Bolt System catalogue for
Contact AR for non-standard sizes or thread configurations. technical information or consult the AR Technical Department.

Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102 Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102
and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart. and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart.

66 67
SINGLE SIDED SINGLE SIDED
FORMING FORMING
SYSTEM SYSTEM

Drop-In Anchor Formsavers TM

TM
The lag thread AR Drop-in Anchor features an internally threaded all-steel AR Formsaver dowel bar assemblies provide continuity and structural
shell, with an preassembled expansion cone insert. The Drop-In Anchors are integrity to reinforced concrete construction in segmental pour applications.
TM
designed to work as part of the forming system, matched to the thread of The AR Formsaver is designed with our unique tapered thread system,
AR Lagstuds or Lagbolts. The Drop-In Anchors are made from carbon steel factory installed thread protectors, and durable mounting plates for easy
and electroplated galvanized for corrosion protection. The Drop-in Anchor is attachment to forms. The taper threaded design, like the complete family of
used for any application requiring anchorage in solid concrete couplers, provides load path continuity in tension, compression and stress
TM
or homogeneous igneous rock. Ideal for lagging, AR Drop-In Anchors are reversal applications. AR Formsaver mechanical splices provide superior
also effective for hanging bolting or anchoring application with AR Tylags, performance well beyond the yield strength of the reinforcing bar.
Lagstud Bolts or Lagstud. Not recommended for uncured concrete (less
than 7 days old), lightweight concrete or masonry block or brick.
REBAR DESIGNATION Taper Threaded Rebar (Male) 1
Coupler/Rebar Assembly (Female) 2

ASTM Part Length “C” Part Length “D”


Anchor Length
in-lbs mm Type Soft Metric Number mm (in) Number mm (in)
Anchor Drill Bit Thread Thread Length (Minimum Depth
of Embedment) 4 12 m 10 M 13 mm FS4M24 610 mm (24") FS4F20 508 mm (20")
NCA ½LT 5
/8 " ½" - 6 lagthread 20 mm ( ¾ ") 50 mm (2") FS4M36 914 mm (36") FS4F24 610 mm (24")
5 16 mm 15 M 16 mm FS5M24 610 mm (24") FS5F24 610 mm (24")
NCA ¾LT 1" ¾" - 4½ lagthread 35 mm (13 /8 ") 80 mm (3 3/16 ")
FS5M30 762 mm (30") FS5F30 762 mm (30")
FS5M36 914 mm (36") FS5F36 914 mm (36")
Ultimate Shear and Tension Values (kN/lbs) in Concrete 6 20 mm 20 M 19 mm FS6M36 914 mm (36") FS6F24 610 mm (24")
FS6F36 914 mm (36")
Anchor Tension Shear 7 22 mm — 22 mm FS7M36 914 mm (36") FS7F36 914 mm (36")
f’c = 15MPa (2,200 psi) f’c = 30MPa (4,400 psi) f’c = 15MPa (2,200 psi) FS7M48 1219 mm (48")
8 25 mm 25 M 25 mm FS8M48 1219 mm (48") FS8F52 1321 mm (52")
NCA ½LT 15 (3,300) 27 (6,075) 20 (4,500)
9 28 mm 30 M 29 mm FS9M48 1219 mm (48") FS9F52 1321 mm (52")
NCA ¾LT 36 (8,100) 49 (11,000) 42 (9,450) 10 32 m - 32 mm FS10M60 1524 mm (60") FS10F64 1626 mm (64")
SINGLE SIDED

SINGLE SIDED
11 36 mm 35 M 36 mm FS11M60 1524 mm (60") FS11F64 1626 mm (64")
FORMING

FORMING
SYSTEM

SYSTEM
AR suggests a minimum safety factor of 2:1. On site conditions such as, poor concrete, 1
Includes Rebar Thread Protector
placing technique, concentrated loads on the formwork, improper use of cranes or concrete To order, please specify 2
Includes Coupler Thread Protector A E
pumping could increase the risk. If such site conditions exist, the user must increase the the following information
safety factor to compensate.
EXAMPLE D C Z
For anchoring situations not associated with forming, industry practice is to apply a safety B
factor of 4:1 minimum. For applications of greater risk a larger safety factor may be selected. Name .................................... Drop-In Anchor
Specify A, B Specify E, B
For edge distance and load reductions contact AR technical representative. Quantity ................................................. 200
Specify D dimension dimension dimension Specify C dimension
Specifications subject to change without notice. How to Order by Part Number
FS SIZE STYLE LENGTH X LENGTH E
Hole must be cleaned of dust and other material Attached Rebar F indicates coupler/rebar, In mm (inches) Indicates In mm Epoxy
nailer plate size M indicates threaded rebar of “A”, “C” bent rebar (inches) of (optional)
Drop-In Anchor form saver (other styles on request) or “D” (optional) “B” (optional)

Setting Tool
Non standard custom sizes
and lengths available.

Drilled Hole
Highway/
Min depth equals anchor length Bridge
Slabs
1. Drill hole for 2. Insert expansion anchor 3. Using an NCA setting tool, set anchor by driving until
expansion anchor into hole and tap flush shoulder of the setting tool is seated against the anchor

Rebar
Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102
and typical Medium and Heavy Formwork beginning on page 108. See page 51 for approximate safe working load System Chart. Stairwell Form-Saver

68 69
TAPER-TY TAPER-TY
SYSTEM SYSTEM

Welding Lagnut Taper-Ty System

AR Welding Lagnuts are designed to be used in single sided (blind side) forming The AR Taper-Ty System is used where Grip usually form thickness + 4" Wall dimension + 1 1/2" Usually form thickness + 4"
Knock-out
applications or when necessary to secure formwork to steel members. AR welding lagnuts specifications permit the complete Wrench end Large diameter Small diameter end

are extra deep to allow for the welding operation and are only available in removal of the form-tie from the concrete
20 mm (3/4") diameter. A licensed certified welder should perform all welding. wall. Taper-Tys are available with lag W
Field-testing should be conducted to established actual approximate safe working loads. thread and a variety of hardware. While
the system is available in the standard T Taper up to 30" standard S

Diameter Depth of Lagnut Safe Working Load Ultimate APPROXIMATE SAFE diameters shown, variations of these 1" 10" 6" 1"

20 mm (¾") 38 mm (1½") 80 kN (18,000 lbs) 160 kN (36,000 lbs) WORKING LOAD sizes are available on special order. The Overall length
complete system consists of one Taper
2:1 Safety Factor Ty, with 2 square or flat washers and 2 Wing Nut Taper-Ty
Washer

Size Ultimate Strength Page nuts, either lag Hex Nuts, special Handle
Product Reference Lagnuts or Malleable Wing Nuts. The
mm (in) kN (lbs)
standard units are furnished with up to
Lagnut 13 mm (½") 80 kN (18,000 lbs) 750 mm of taper. Other taper lengths
Refer to are available on special order. The larger
20 mm (¾") 160 kN (36,000 lbs)
page 54 diameter end has a square wrench end.
25 mm (1") 333 kN (75,000 lbs)
The smaller diameter end has been Taper-Ty Washer
32 mm (1¼") 435 kN (98,000 lbs) designed with a special end for removal
38 mm (1½") Consult the AR Technical Department for details. without damaging the thread. Other
specifications are shown
Handle 13 mm (½") 80 kN (18,000 lbs) on the detail drawing.
Lagnut 20 mm (¾") 160 kN (36,000 lbs) Refer to Not recommended where watertight walls are essential such
25 mm (1") 333 kN (75,000 lbs) page 54 as exterior walls, water reservoirs, treatment plants, etc. Use Use Handle Lagnut or Wing Nut
32 mm (1¼") 512 kN (115,000 lbs) Waterseal Tyscrus instead.
38 mm (1½") Consult the AR Technical Department for details. Taper Ty Wall Sizing
Diameter Safe Working Loads Length of 1" thread Taper Length Length of 3/4" thread
Wing Nut 20 mm (¾") (large to small) 2:1 Safety Factor
178 kN (40,000 lbs)
TAPER-TY

TAPER-TY
Refer to
SYSTEM

SYSTEM
25 mm (1") page 55 20 mm to 13 mm (¾" to ½") 40 kN (9,000 lbs.)
365 kN (80,000 lbs) Wall Thickness
20 mm to 23 mm (¾" to 7 8 " ) 89 kN (20,000 lbs.)
32 mm (1¼") 512 kN (115,000 lbs) 25 mm to 20 mm (1" to ¾") 84 kN (19,000 lbs.)
32 mm to 25 mm (1¼" to 1") 155 kN (35,000 lbs.)
Flat Washer 95 x 95 x 6 mm (3¾" x 3¾" x ¼") 60 kN (13,500 lbs) 38 mm to 32 mm (1½" to 1¼") 253 kN (57,000 lbs.)
125 x 125 x 10 mm (5" x 5" x 3/8") 222 kN (50,000 lbs) Refer to
Chart based on standard 825 MPa (120,000 psi) material. Taper-Ty
150 x 150 x 13 mm (6" x 6" x ½") 266 kN (60,000 lbs) page 56 Special order materials available on request.
200 x 200 x 19 mm (8" x 8" x ¾") 1,110 kN (250,000 lbs) Overall Taper-Ty Length

Batter Washer 13 x 41 mm (1½" x 1 5/8") Consult the AR Technical Refer to


Department for details. page 57

APPROXIMATE SAFE
WORKING LOADS 2:1
Lag Thread 13 mm (½") 80 kN (18,000 lbs)
Refer to Taper Ty Wall Sizing
Coupler 20 mm (¾") 160 kN (36,000 lbs)
page 57 To order, please specify the following information
25 mm (1") 334 kN (75,000 lbs) Overall length Length of Thread Taper Length Range of Wall Thickness*
EXAMPLE mm (in) 25 mm (1") 20 mm (¾") mm (in) mm (in)
Name .................................................... Taper-Ty
Nominal Size 953 mm (37½") 250 mm (10") 150 mm (6") 540 mm (21½") 100 mm - 405 mm (4" - 16")
Heavy 13 mm (½") 80 kN (18,000 lbs) Calculate Length ...................................... (29½") 1,067 mm (42") 250 mm (10") 250 mm (10") 560 mm (22") 150 mm - 535 mm (6" - 21")
Hex Rod Thread Length 1,219 mm (48") 250 mm (10") 250 mm (10") 710 mm (28") 300 mm - 660 mm (12" - 26")
16 mm ( 5/8") 134 kN (30,000 lbs) Refer to
Coupler page 77 Large diameter end 250 mm ............... (15") *Based on standard forming materials (typical 4x4 studs, walers, ¾" form ply, plate washer and nut assembly).
20 mm (¾") 160 kN (36,000 lbs)
Small diameter end 150 mm .............. (6")
22 mm ( 7/8") 220 kN (60,000 lbs) Diameter ........... 20 mm to 13 mm (3/4" to 11/2") Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102 and
25 mm (1") 334 kN (75,000 lbs) Quantity ........................................................ 200 typical Medium and Heavy Formwork beginning on page 108. See page 51 for Approximate Safe Working
Load System Chart.

70 71
TAPER-TY SHE-BOLT
SYSTEM PRODUCTS

Flat Washer She-Bolt

Refer to page 56 AR She-Bolt Assemblies are high strength, adaptable units


suitable for medium and heavy concrete construction.
Manufactured with external lag threads, they provide a
positive system for use with gang forms and/or steel forms.
Tilt Washer The Inside Rods are manufactured with either national
coarse thread or lag thread. If desired, continuous threaded
The AR Tilt Washer is angularly adjustable up to 45°, eliminating the lagstud can be furnished in 1,500 mm or 3,000 mm (5' or 10')
need for wedging on battered walls or when tying across corners. lengths for field cutting to required specifications.
Nail holes are provided for attaching the Tilt Washer to the waler or
strongbacks. Available for 25 mm and 32 mm (1" and 1¼") diameter Variable 2400 mm (8'-0") to 3000 mm (10'-0") Lift Form using She Bolts with High Tensile Lagstud
bolts with nail holes to permit nailing to wales if desired. To order, please specify
the following information EL. 3000 mm (10'-0")
EXAMPLE Screw Anchor Anchor position for 3000 mm (10'-0") pour
Bolt EL. 2700 mm (9'-0")
Name ................................................ She-Bolt
Bolt Diameter Size
Nominal Diameter Anchor position for 2700 mm (9'-0") pour
Type mm (in) mm (in) Inside Rod Diameter .................. 20 mm (¾")
EL. 2400 mm (8'-0")
AR 1 25 mm (1") 160 mm x 133 mm (6¼" x 5¼") Overall Length (O) ..................... 510 mm (20")
Anchor position for 2400 mm (8'-0") pour
AR 1¼ 32 mm (1¼") 175 mm x 150 mm (7" x 6") Outside Thread (T) .................... 250 mm (10")
Inside Thread Type (R) ............................. lag She Bolt
Outside Thread Type ................................. lag
Quantity .................................................... 200
Tilt Washer
Lagstud
To order, please specify
the following information
EXAMPLE Tie-down position for
Name .......................................... Tilt Washer
APPROXIMATE SAFE Wing
Nut
2700 mm (9'-0")
and 3000 mm (10'-0") pour
Nominal Diameter .......................... 25 mm (1") She-Bolt
WORKING LOAD
Quantity .................................................... 200 (contour thread) 2:1 Safety Factor Tie-down position
TAPER-TY
SYSTEM

Wing Nut for 2400 mm


Batter
(8'-0") pour
Washer

PRODUCTS
SHE-BOLT
45˚
30˚
Lag thread R
May be 6"
extended
T 100 mm (4") for
W I
alignment
O (overall length)
3 mm (1/8") less nominal She Bolt diameter
Screw Anchor Tyscru anchorage

She-Bolt Dimension Data

Nominal Diameter Internal Thread Diameter Length O Thread T I W R


mm (in) mm (in) mm (in) mm (in) mm (in) mm (in) mm (in)
25 mm (1") 13 mm (½") 500 mm (20") 250 mm (10") 20 mm (¾") 13 mm (½")
29 mm (11/8 ") 600 mm (24") 300 mm (12") 20 mm (¾") 20 mm (¾")
32 mm (1¼") 500 mm (20") 250 mm (10") 25 mm (1")

(2 x diameter
2 x diameter
plus 6 mm
20 mm (¾") 20 mm (¾")

plus ¼")
35 mm (13 /8 ") 600 mm (24") 300 mm (12") 25 mm (1")
38 mm (1½") 25 mm (1") 600 mm (24”) 250 mm (10") 25 mm (1")
800 mm (32") 300 mm (12") 25 mm (1") 25 mm (1")
460 mm (18") 25 mm (1")

Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102 and typical Medium
and Heavy Formwork beginning on page 108. See page 51 for Approximate Safe Working Load System Chart.

72 73
SHE-BOLT SHE-BOLT
PRODUCTS PRODUCTS

She-Bolt Crimped Anchor

High Tensile Inside Rod AR Crimped Anchors are


used for form anchoring in
mass concrete construction. Approximately 10º
Manufactured in the diameter
Wing Nut and lengths shown with either
She-Bolt national coarse thread or lag
thread.
Flat Washer
Lag Thread Inside Rod Dummy
NC Thread 1500 mm (5'-0")
APPROXIMATE SAFE She-Bolt
WORKING LOAD 2:1
Setting
Bracket
Handle Lagnut
To order, please specify
She-Bolt
the following information Crimped
NC Thread Anchor
EXAMPLE
Name .................................... Crimped Anchor
Flat Washer
Lag Inside Rod Diameter ..................................... 13 mm (1/2")
Thread Lag Thread
Length ....................................... 30 mm (12") Batter
Type of Thread ............................................ NC Washer
Quantity .................................................... 200 She-Bolt

She-Bolt
Handle Lagnut
Lag Thread

Threaded
Inside Rod
Nominal Internal Thread Diameter APPROXIMATE SAFE WORKING LOAD
She-Bolt
Diameter 13 mm (½") 20 mm (¾") 25 mm (1") 2:1 Safety Factor
mm (in) kN lbs kN lbs kN lbs
*Maximum She-Bolt Approximate Safe Working Load capacity at minimum 2:1 Rod Coupling
25 mm (1") 40 9,000 80* 18,000 - -
Safety Factor which is highly recommended for reusable working parts.
29 mm (11/8 ") 40 9,000 80* 18,000 - -
32 mm (1¼") 40 9,000 80 18,000 - -
NOTE: 50 mm (2") available as a special order. Consult your AR Sales Representative
PRODUCTS

PRODUCTS
SHE-BOLT

SHE-BOLT
38 mm (1½") 40 9,000 80 18,000 165* 37,500 or AR Technical Department for more information. Crimped
Crimped Anchor Safe Working Loads Wing
Nut Anchor
Diameter Safe Working Load Ultimate
High Tensile Inside Rod 13 mm (½") 40 kN (9,000 lbs) 80 kN (18,000 lbs)
20 mm (¾") 80 kN (18,000 lbs) 160 kN (36,000 lbs)
25 mm (1") 165 kN (37,500 lbs) 330 kN (75,000 lbs)
AR High Tensile Inside Rods are manufactured with either
National Coarse or lag thread. Inside Rods can be manufactured
with crimps upon request. Rods up to 600 mm (24") long have Thread
Thread Length Standard (Overall) Lengths Set back Number of Crimps
1 crimp. Rods over 600 mm (24") long have 3 crimps. Diameter
13 mm (½") 32 mm (1¼") 450 mm, 600 mm, 750 mm (18", 24", 30") 102 mm (4")
Under 600 mm (24") 3 crimps,
To order, please specify the following information 16 mm ( 5 /8 ") 38 mm (1½") 600 mm, 750 mm, 900 mm (24", 30", 36") 102 mm (4")
Over 600 mm to 916 mm
EXAMPLE APPROXIMATE SAFE 20 mm (¾") 45 mm (1¾") 750 mm, 900 mm, 1,050 mm (30", 36”, 42") 102 mm (4")
(24" to 36") 6 crimps,
Name .................................. High Tensile Inside Rod WORKING LOAD 2:1 22 mm (1") 50 mm (2") 900 mm, 1,050 mm (36", 42") 102 mm (4")
Over 900 mm (36") 9 crimps
Diameter ............................................ 13 mm (1/2") 25 mm (1¼") 57 mm (2¼") 900 mm, 1,050 mm, 1,200 mm (36", 42", 48") 102 mm (4")
Length ............................................. 600 mm (24") Diameter Safe Working Load Ultimate Tension
Crimped or non-crimped .......................... Crimped mm (in) kN (lbs) kN (lbs)
Type Thread .................................................... NC
13 mm (½") 40 9,000 80 18,000
Length of Thread (each end) ............... 75mm (3")
20 mm (¾") 80 18,000 160 36,000
Quantity ......................................................... 200
25 mm (1") 160 37,500 330 75,000

Refer to the Appendix for General Guidelines on page 96, Lateral Pressure information on page 102 and typical Medium Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for
and Heavy Formwork beginning on page 108. See page 45 for Approximate Safe Working Load System Chart. various concrete strengths table on pages 51 and 112 of the Appendix.

74 75
SHE-BOLT SHE-BOLT
PRODUCTS PRODUCTS

Dummy She-Bolt Heavy Hex Rod Coupler

AR Dummy She-Bolts are manufactured slightly oversize for AR Heavy Hex Rod Couplers are used to couple two High Tensile Inside Rods
easy re-entry of standard She-Bolt. Furnished in standard sizes of the same diameter. The Coupler is normally supplied with NC thread and is
for either National Coarse or lag thread High Tensile Inside Rods available with lag thread on request. Standard sizes are shown and other sizes
or Crimped Anchors. are available on request.

APPROXIMATE SAFE
To order, please specify the following information
WORKING LOAD 2:1
EXAMPLE
Name ......................................... Dummy She-Bolt Rod Diameter Overall Length kN (lbs)
Nominal Diameter Length ................ 500 mm (20") To order, please specify the following information
13 mm (½") 45 mm (1¾") 40 kN 9,000 lbs
Type of inside thread ......................................... NC APPROXIMATE SAFE EXAMPLE 16 mm ( 5/8 ") 57 mm (2¼") 67 kN 15,000 lbs
Quantity ......................................................... 200 Name ................................. Heavy Hex Rod Coupler
WORKING LOAD Nominal Rod Diameter ........................ 13 mm (1/2")
20 mm (¾") 57 mm (2¼") 80 kN 18,000 lbs
See table on page 74 22 mm ( 7 /8 ") 64 mm (2½") 135 kN 30,000 lbs
Quantity .......................................................... 200
25 mm (1") 70 mm (2¾") 169 kN 37,500 lbs

Bowlag Anchor
Hex Nut
AR Bowlag Anchors provide an effective and efficient She-Bolt reanchorage for
cantilever and Ty back lift forms. The continuous lag thread and the bow shape
provide good anchorage even in green concrete and consistently outperforms AR Hex Nuts are manufactured with a UNC thread and are available
smooth crimped rods and/or pigtails. The lag thread engagement is quick to from 13 mm to 38 mm (½" to 1½") diameter.
install or disconnect. The bow shape prevents loosening during vibration and
resists rotating or spinning during stripping.

APPROXIMATE SAFE
PRODUCTS

PRODUCTS
SHE-BOLT

SHE-BOLT
WORKING LOAD 2:1 TOP OF LIFT

To order, please specify the following information


EXAMPLE
Name ............................................. Bowlag Anchor Bowlag Anchor
Nominal Diameter .............................. 25 mm (1")
Length ............................................. 900 mm (36")
Quantity ......................................................... 200 D

L
Anchor Working Loads Grip
Length “L” Drop “D” Setback
diameter @ 3.5 MPa (500 psi) @ 4.8 MPa (700 psi)

20 mm (¾") 600 mm (24") 150 mm (6") 53 kN (12,000 lbs) 71 kN (16,000 lbs)


750 mm (30") 150 mm (6") 64 kN (14,500 lbs) 80 kN (18,000 lbs)
22 mm (7/8 ") 750 mm (30") 225 mm (9") 90 kN (20,000 lbs) 102 kN (23,000 lbs)
900 mm (36") 225 mm (9") 98 kN (22,000 lbs) 111 kN (25,000 lbs)
25 mm (1") 900 mm (36") 225 mm (9") 120 kN (27,000 lbs) 135 kN (30,000 lbs)

Refer to the Approximate Safe Working Loads and Ultimate Capacities calculated for
various concrete strengths table on pages 51 and 112 of the Appendix.

76 77
EURO EURO
ROD ROD

Euro Rod Euro Rod Accessories

The AR Euro Rod is a high tensile form tie used in Euro Rod Hex Couplers
industrial formwork systems, lost anchoring solutions,
special connections and applications for cast-in-place. APPROXIMATE SAFE WORKING LOAD 2:1
The rod has two flat sides in the thread pattern which
Rod Diameter Coupler Length
provide a self-cleaning feature and allow a gripping
mm in mm in Box Qty
surface for turning the bar without damaging the threads.
15 5/8" 50 2" 75
Available in 5/8" and 7/8" bar diameters, in standard
19'-1" lengths. Additional sizes available on request. 15 5/8" 100 4" 40

APPROXIMATE SAFE
WORKING LOAD 2:1
Euro Rod Hex Flange Nuts
Diameter
mm (in) kN SWL (lbs) APPROXIMATE SAFE WORKING LOAD 2:1
15 5/8" 19'-1" 22,000
Rod Diameter Flange Nut Length
20 7/8" 19'-1" 38,900 Description
mm in mm in Box Qty
15 5/8" With Bottom Flange 25 1" 125
Euro Rod Accessories 15 5/8" With Hex End 106 4-1/8" 25

Euro Rod Combo Plate Euro Rod She-Bolt Cones

APPROXIMATE SAFE WORKING LOAD 2:1 APPROXIMATE SAFE WORKING LOAD 2:1
Rod Diameter Washer Size Rod Diameter Cone Length
mm in mm in SWL (Lbs) mm in mm in Box Qty
15 5/8" 120x120 4-3/4" 21,900 15 5/8" 75 3" 45
22 7/8" 120x120 4-3/4" 39,200 15 5/8" 100 4" 25

Euro Rod Distance Tube


Euro Rod Single Wing Nut
APPROXIMATE SAFE WORKING LOAD 2:1
EURO ROD

EURO ROD
APPROXIMATE SAFE WORKING LOAD 2:1
Rod Diameter Tube Length
Rod Diameter Size mm in mm in
mm in mm in SWL (Lbs) 15 5/8" 2,000 79"
15 5/8" 90x60 3-1/2"x2-3/8" 21,900 22 7/8" 2,000 79"
22 7/8" 90x60 3-1/2"x2-3/8" 39,200

Euro Rod Distance Cones


Euro Rod Round Wing Nut

APPROXIMATE SAFE WORKING LOAD 2:1 APPROXIMATE SAFE WORKING LOAD 2:1
Rod Diameter Wing Nut Diameter Rod Diameter
mm in mm in SWL (Lbs) mm in
15 5/8" 100 4" 21,900 15 5/8"
22 7/8" 100 4" 39,200 22 7/8"

78 79
NOTES

FORMING
ACCESSORIES
80 81
GENERAL GENERAL
FORMING FORMING
ACCESSORIES ACCESSORIES

Hook Anchor Bolt Pig Tail Anchor Bolt

The AR Hook Anchor Bolt is manufactured with either lag The AR Pig Tail Anchor Bolt is manufactured with either lag
thread or national course threads and is typically supplied thread or national course threads. AR can accommodate
with a 90° radius. AR can supply custom bent bolts when special orders in black, plated or hot dipped galvanized.
provided with detailed specifications and drawings. AR can Available in 13 mm, 20 mm, 25 mm and 32 mm (½", ¾",
accommodate special orders in black, plated, hot dipped 1" and 1¼") diameter.
galvanized or stainless steel. Available in 13 mm, 20 mm,
25 mm and 32 mm (½", ¾", 1" and 1¼") diameter.
To order, please specify the following information
EXAMPLE
To order, please specify the following information Name ....................................... Pig Tail Anchor Bolt
EXAMPLE Diameter ............................................... 25 mm (1")
Name ......................................... Hook Anchor Bolt Quantity ........................................................... 200
Diameter ............................................... 25 mm (1")
Quantity ........................................................... 200

Wall Plate Anchor Post Holders

AR Wall Plate Anchors are manufactured with The AR Post Holders are designed to attach wooden posts to concrete,
Unified National Coarse (UNC) thread and are made of heavy gauge steel and provide strength and stability to outdoor
supplied complete with a nut and washer. AR T decks. All post holders are coated (black) for corrosion protection and are
can accommodate special orders in black, D available in sizes: 4”x4”, 4”x6” and 6”x6”.
plated, hot dipped galvanized or stainless L
steel. Available in 10 mm to 50 mm (3/8" to 2")
diameter. Custom orders available on request. To order, please specify the following information
EXAMPLE
Name .................................................. Post Holders
C Size .............................................................. 6" x 6"
To order, please specify the following information Quantity ............................................................. 20
EXAMPLE
Name ........................................ Wall Plate Anchor
Diameter ............................................ 13 mm (1/2")
ACCESSORIES

ACCESSORIES
Length ............................................ 300 mm (12")
FORMING

FORMING
GENERAL

GENERAL
Thread ........................................................... UNC
Type of steel .............................. mild black steel
Quantity ......................................................... 200

82 83
GENERAL GENERAL
FORMING FORMING
ACCESSORIES ACCESSORIES

Anchor Sleeve AR Form Tubes

AR Anchor Sleeves are a plastic void form made of high density polyethylene that is non- AR concrete forming tubes are built to withstand
rusting and non-conductive. They expedite the mounting of machinery and equipment, and the rigors of construction. Designed to hold the full
are maintenance free and easy to use. When using the AR Anchor Sleeve, initial material and hydrostatic pressure load of concrete in a single
installation costs are greatly lowered, and all welding, pipe cutting, packing, bending, forming, continuous pour, AR tubes have earned their mark
cleaning and chipping out are eliminated. as a “go to” standard for the most demanding
construction projects. Shields against moisture
and adverse weather conditions to help keep
the elements from impacting your construction
Projection Projection schedule. Manufactured with 100% recycled
Top of To order, please specify
Top of as required as required paperboard. Available in diameters from 6 inches to
concrete
concrete the following information
60 inches. Standard wall thickness to 12 feet, heavy
EXAMPLE
wall thickness to over 30 feet.
Wilson Name .................. AR Anchor Sleeve
Anchor Wilson
Sleeve 8d Anchor 8d Anchor Bolt Diameter ... 13 mm (1/2")
minimum Sleeve minimum Quantity ................................... 200
Grout
Grout
Handyform Tube
A
Anchor Bolt Material and Testing Data
Anchor Bolt
A
AR Handyform tubes are built to be used in smaller projects by contractors and
Length Plastic: High density polyethylene
Length weekend warriors. Designed to hold the full hydrostatic pressure load of concrete
Density, gms/cc: ASTM D 1505-68 .956
d
Vicat softening point °F (°C): ASTM D 1525-70 256°F (124°C)
in a single continuous pour, AR tubes have earned their mark as a “go to”
d
Brittleness temp. °F (°C): ASTM D 746-70 -180°F (-119°C) standard for the most demanding construction projects. Shields against moisture
Washer Torch application: Slow burn and adverse weather conditions to help keep the elements from impacting your
H and nut
Wall Plate Compression test: 12.7 kg (180 psi) per square inch construction schedule. Manufactured with 100% recycled paperboard.
Anchor
Each Sleeve is approximately twice the bolt diameter with a depth of 8 bolt diameters, minimum. Available in diameters from 10 inches to 36 inches, and length of 12 feet.

TABLE — GROUT VOLUME REQUIRED


Preparatory Work: None
Bolt Diameter Sleeve Size Litres of Cubic inches # sleeves kgs (lbs)
Limitations: The AR Anchor Sleeve Series
mm (in) mm (in) grout per shell per shell per carton per bundle
is not recommended where high heat
13 mm (½") .26
is used, such as inside an oven.
20 mm (¾")
AX
AX
50 mm x 130 mm
50 mm x 130 mm
(2" x 5")
(2" x 5") .25
15.95
15.16
100
100
4
4
AR Nails
Caution: When using the AR Anchor Sleeve
16 m ( 5/8 ") A 50 mm x 180 mm (2" x 7") .35 21.41 100 5
outdoors or under freezing conditions, the 20 mm (¾") A 50 mm x 180 mm (2" x 7") .34 20.50 100 5
sleeve must be sealed around the bolt to 25 mm (1") B 75 mm x 255 mm (3" x 10") 1.06 65.80 50 6 AR Nails feature a round smooth shank which reduces wood
prevent moisture penetration or filled with 32 mm (1¼") B 75 mm x 255 mm (3" x 10") 1.00 61.40 50 6 splitting. Nails are available as common nails and duplex
Antifreeze. 38 mm (1½") C 100 mm x 380 mm (4" x 15") 2.75 167.60 20 6 (double head) nails, commonly used for interior and exterior
ACCESSORIES

ACCESSORIES
FORMING

FORMING
GENERAL

GENERAL
Installation: The bottom of the sleeve 42 mm (1¾") C 100 mm x 380 mm (4" x 15") 2.60 158.00 20 6
construction and framing. Available from 2” to 3½” in ¼”
is passed over the top of the bolt until 50 mm (2") D 100 mm x 460 mm (4" x 18") 2.90 176.76 20 7
57 mm (2¼") D 100 mm x 460 mm (4" x 18") 2.66 161.82 20 7 increments, 50 lb boxes. Nails conform to ASTM F1667
the threaded portion engages the self-
threading top of the sleeve. The sleeve 64 mm (2½") E 150 mm x 610 mm (6" x 24") 9.50 575.28 10 8 standard.
76 mm (3") E 150 mm x 610 mm (6" x 24") 8.80 523.44 10 8
is turned until the proper projection is
obtained. The entire assembly is cast NOTE: Grout estimate based on .46 cu/ft yield per 55 lb of non-corrosive grout.
into the concrete, with the top of the AR Concrete Nails
sleeve at foundation level. When the
anchor bolt is ready for adjustment, STEP 1 Bolt STEP 2 STEP 3 STEP 4 STEP 5
Nut
the top of the sleeve is cut off and Thread Template
AR Concrete Nails feature a round smooth shank which
Length
discarded. The bolt may now be Grout
reduces wood splitting. Available in 2” and 3”, 4.5 lb packs.
Template
adjusted within the sleeve. Flush
Nails conform to ASTM F1667 standard.
Expansion or non-shrinking grout is cast
into the sleeve around the bolt when
equipment is set. Other applications are
done in a similar fashion.
See table for hole size in Screw bolt through sleeve bottom Insert sleeved bolt into template. Before installing equipment, Install equipment: grout
template up to top to thread length spec. Hand tighten nut to secure in place. cut out top of sleeve

84 85
GENERAL GENERAL
FORMING FORMING
ACCESSORIES ACCESSORIES

Falsework Support Bracket Guardrail Base

AR Falsework Support Brackets are used with 32 mm (1¼") AR Screw The single component AR Guardrail Base provides set back
Anchors and Bolts to support pier cap forms. The use of Falsework Support requirements. The solid galvanized steel construction is
Bracket eliminates posting or scaffolding which can be expensive and time significantly stronger than typical wood fabrications and adds
consuming to erect. Brackets can be manufactured with 2, 4 or 6 holes. safety and reliability. The Guardrail Base is reusable and fast
and simple to install on plywood or concrete surfaces.
Falsework Support Safe Working Load Required
Meets Load Requirements of Section 26.3 of the Ontario
Bracket kN (lbs) Screw Anchors
Health and Safety Act and Regulations for Construction Projects
2 hole 89 kN (20,000 lbs) two 32 mm (1¼") diameter (ISBN 0-7778-9412-2 Rev 06/00), when assembled with other
4 hole 178 kN (40,000 lbs) four 32 mm (1¼") diameter components to form guardrail system complying with the Act.
6 hole 267 kN (60,000 lbs) six 32 mm (1¼") diameter

APPROXIMATE SAFE To order, please specify


the following information
WORKING LOAD
EXAMPLE
3:1 Safety Factor
Name ....................................... Guardrail Base
Quantity .................................................... 200
To order, please specify the following information
EXAMPLE
2X4
Name ......................... Falsework Support Bracket
Number of Holes ................................................. 4
Quantity ......................................................... 200

Guardrail
Base

Determining total load


To determine the total load to be supported by each falsework bracket, compute the total mass (weight of concrete)
plus the liveload (weight of form and other temporary loads) and divide by the number of brackets to be used.
Wood
Example: Screws
The dimension of a concrete beam to be poured over two columns and supported by 4 brackets is as follows:
Plywood or
concrete
750 mm wide x 1200 mm high x 18500 mm long (30" wide x 48" high x 740" long)
ACCESSORIES

ACCESSORIES
FORMING

FORMING
GENERAL

GENERAL
Density of concrete assumed = 2,400 kg/m3 (150 lb/ft3)
Live load or mass per unit area assumed = 365 kg/m2 (75 lb/ft2)
AR Anti-Impalement Rebar Cap
Mass of beam .75 m x 1.2 m x 18.5 m x 2400 = 39,900 kg (18,100 lbs)
Mass of live load .75 m x 18.5 m x 365 = 5,065 kg (2,300 lbs)
The AR Anti-Impalement rebar protection cap is a safety cap with a metal
44,964 kg (20,400 lbs) dome plate, used to prevent rebar from impaling workers in case of falls.
The cap is OSHA compliant and is available for #3 (10 mm) to #8 rebar
Force exerted by mass = 44,964 x .00981 = 441.10 kN (99,100 lbs)
(25 mm), 25 pieces per box.
Force per bracket: 441.10 = 110.28 kN (24,800 lbs)
4
Therefore use 4 hole bracket with four 32 mm (1¼") diameter Screw Anchors.
NOTE: 1 kilogram = .00981 kiloNewtons

86 87
GENERAL GENERAL
FORMING FORMING
ACCESSORIES ACCESSORIES

Reinforcing Bar Supports (SB) Slab Bolster

Reinforcing Bar Supports are used to support and space reinforcing steel. AR Bar Supports are manufactured Used for supporting lower slab steel from slab form.
according to specifications published by the Concrete Reinforcing Steel Institute. To eliminate rust spots or similar Corrugations spaced 1” (25 mm) on centres serve as
blemishes on the concrete surface specify AR’s Plastic Bar Supports. guides for spacing bars. Legs are spaced 5” (127 mm)
on centre. Stocked in 3/4”, 1”, 1 1/2”, 2” (20, 25, 38
and 50 mm) in heights in 5’ (1525 mm) lengths.
Linden Chairs

Corrosion free All Plastic Linden Chairs are used in slabs for supporting all types of reinforcing steel. Excellent for
supporting epoxy coated rebar in bridge deck construction, or where-ever a corrosion free support is required. The
high sizes have an arch design for straddling lower mats of rebar. The chair is made of High Impact polypropylene (PSB) Slab Bolster And All Plastic Continuous High Chair
and its design gives it the strength of steel. Linden chairs are strong yet light in weight and packaged in poly bags
for convenience of carrying around job sites.
AR Plastic Slab Bolster is used for supporting lower slab steel from slab form. HEIGHT
Corrugations spaced 1” (25 mm) on centres serve as guides for spacing bars. in (mm) in (mm)
LINDEN CHAIRS SIZES AND PACKAGING WEIGHTS Legs are solid plastic 4” (100 mm) on centre. Supporting cross bar is made from 34 (20) 23 4 (70)
high strength plastic coated steel. Corrosion-proof and lightweight for handling. 1 (25) 3 (76)
inch mm PCS/BAG LBS/MFT CTN SKID SKID QTY
1 25 500 30 40 20,000 11 4 (32) 5 (125)
11 4 32 500 35 40 20,000 11 2 (38) 51 2 (138)
11 2 40 250 46 40 10,000 13 4 (44) 6 (150)
13 4 45 250 50 40 10,000 (50)
2 61 2 (163)
2 50 250 62 40 10,000
21 2 (63) 7 (175)
21 4 58 200 78 40 10,000
21 2 63 200 82 40 8,000
23 4 70 300 84 25 7,500
3 75 300 85 25 7,500
31 4 77 300 88 25 7,500
31 2 85 300 90 25 7,500
33 4 92 200 93 25 5,000
4 100 200 95 25 5,000 LINDEN CHAIR DATA SHEET
41 4 108 200 98 25 5,000
41 2 110 200 112 25 5,000 Size Available 1-10 inches (25-254 mm)
43 4 120 200 119 25 5,000
every 1/4” (6 mm) (CHC) Continuous High Chair
5 125 200 120 25 5,000 Colour concrete grey
51 4 133 200 125 25 5,000
Material reinforced, high impact polypropylene Continuous High Chairs provide support for
51 2 140 200 130 25 5,000
ACCESSORIES

ACCESSORIES
53 4 146 200 148 25 5,000 Strength a minimum 400 lbs. (180 kg) / chair upper slab steel from slab form, eliminating
FORMING

FORMING
GENERAL

GENERAL
6 150 100 155 25 2,500 Chemical Resistancy excellent carrier bars required with individual supports.
61 4 158 100 160 25 2,500
Packaging in heavy-duty uv protected poly bags Fabricated with plain steel legs (CHC) or with
61 2 165 100 177 25 2,500 Quantity varies by size plastic tipped legs (PCHC). Supplied to order
63 4 170 100 184 25 2,500 in heights from 2” to 12” (50 mm to 300 mm)
7 175 100 195 25 2,500 Installation good for both Black and Corrosion in 1/4” (5 mm) increments and in 5’ (1525 mm)
71 4 183 75 255 25 1,875 resistant rebar place chairs on deck lengths with legs spaced at 6” (150 mm) o.c.
71 2 190 75 310 25 1,875 forms can straddle bottom steel bars
73 4 195 75 338 25 1,875 spacing depends on loads standard
8 200 75 343 25 1,875 spacing is every 3-4 feet (0.9 - 1.2 m)
81 4 210 75 350 25 1,875
81 2 215 50 365 25 1,250
83 4 220 50 378 25 1,250
9 228 50 400 25 1,250
91 4 235 50 415 25 1,250
91 2 240 50 424 25 1,250
93 4 247 50 430 25 1,250
10 254 50 440 25 1,250

88 89
GENERAL GENERAL
FORMING FORMING
ACCESSORIES ACCESSORIES

Tie Wire Formwork Pry Bar

The AR Tie Wire is a fully annealed wire for use The AR Formwork Pry Bar is a heavy duty pry bar ideally suited
in general construction. It is packaged in Wire for use by tilt-up erectors and form setters to strip forms and to
Loop Ties and Rolls designed to fit in standard “jockey” a panel into position or assist in removing forms. The
reels. Available in 16 or 16.5 ga. Pry Bar is available with a 75 mm (3") blade widths.

· 50 lbs. Coils
To order, please specify the following information
· 3.5 lbs. Coils
EXAMPLE
· Wire Loop Tys
Name ........................................ Formwork Pry Bar
· Coated & Uncoated Quantity .............................................................. 2
Blade

Plastic Form Spreader

The AR Plastic Form Spreader eliminates


the need of cutting and placing wood strips
and reduces patching and grouting needs. 90 mm
The Form Spreader is corrosion free and (3 1/2")
reduce water penetration. Available in
Tie Wire Twister 150mm, 200 mm, 250 mm and 300 mm
(6", 8", 10" and 12"). 45 mm (1 3/4")
The AR Tie Wire Twister is offered in a compact size that
allows the tool to be used in tight spaces. Safely and easily To order, please specify the following information 25 mm (1")
twists wire bar ties with a durable design. EXAMPLE
Name .................................. Plastic Form Spreader
Quantity .......................................................... 200

PVC - Single Chamfer


ACCESSORIES

ACCESSORIES
FORMING

FORMING
GENERAL

GENERAL
Product Name Width A Height B Chamfer Angle Form
Snap Single Chamfer 3/4” With Tape 0.75" 0.75" 45° Handle Spreader
LC Single Chamfer 3/4” With Tape 0.5" 0.75" 45° Lagnut
LC Single Chamfer 1/2” With Tape 0.5" 0.5" 45°
Single Chamfer 3/4” Top / Inside Chamfer 0.75" 0.75" 45°
Single Chamfer 1/2" x 45 Degree 0.5" 0.5" 45°
LC Single Chamfer 1” With Tape 1” 1” 45°

NOTE: Wood chamfer also available. Consult your


AR Sales Representative or AR Technical Department
for more information.
B
Form
Spreader

A
DURING POUR SETTING FORMWORK

90 91
GENERAL GENERAL
FORMING FORMING
ACCESSORIES ACCESSORIES

Rich-Cote Form Release - Summer & Winter Grade Curb Clamp

A premium liquid debonding agent developed especially for concrete. AR Curb Clamps are strong and durable with special fast thread
25 x 25 mm (1 x 1”)
Through a chemical reaction, RICH-COTETM produces a smooth, white, for adjustment up to 385 mm (15") for securing curb on gutter forms.
flat concrete surface which is free of voids and will bond with paint, Custom sizes are available on request. 230 mm
plaster, tiles and any other coating applied directly to the concrete. (9”)
RICH-COTETM reacts positively with the alkalies in the concrete forming
a water resistant barrier with the concrete that prevents it from binding To order, please specify
to the forms. the following information
RICH-COTETM waterproofs plywood forms preventing the alkalies in the EXAMPLE
concrete from being absorbed and rotting the wood. It is compatible with Name ............................ Curb Clamp
Quantity ..................................... 200
any pre-oiling done at the mill or any other substance previously used
for treating forms. It will not wick out or wash off. Continued use makes 385 mm (15”)
forms completely waterproof and extends their life considerably.
RICH-COTETM can be sprayed at sub-freezing temperatures. It will not
stain and will reduce finishing time by 50%. RICH-COTETM makes form
stripping easier and faster. For the most effective and economical method
of application use the AR Form Sprayer.
Corner Clamp
Drying Time:
1 - 2 hours — leaving a completely workable, non-slip surface.
The AR Corner Clamp is fabricated of 6 mm x 95 mm (1/4" x 33/4") flat steel
Coverage: washer stock bent to form a wedge block with ample bearing flanges drilled
12-18 square metres per litre on most forms. for nailing to the wales. Its principal use is to provide bearing against the
18 - 25 square metres per litre on plastic coated and steel forms. wales for the Tyholders on a diagonal corner tie. Most commonly used with
Lag Rods.

To order, please specify


the following information Corner
Clamp
EXAMPLE
Name ......................... Corner Clamp
Quantity ..................................... 200

Form Sprayer

The AR Form Sprayer is an industrial style Tri-Poxy coated metal


ACCESSORIES

ACCESSORIES
unit with a capacity of 13.2 litres. The AR Form Sprayer comes
FORMING

FORMING
GENERAL

GENERAL
complete with:
· 1200 mm (48") heavy duty hose
· 600 mm (24") brass extension
· three point closures
· lock-in features for continuous spray
· threaded fitting for easy changing of hose, shut-off and nozzle

To order, please specify


the following information
EXAMPLE
Name .......................... Form Sprayer
Quantity ......................................... 2

92 93
GENERAL
FORMING
ACCESSORIES

Barrier Wall Control Joint

The AR Barrier Wall Control Joint is a pre-manufactured


extruded PVC forming insert used in controlling the location
of shrinkage cracks in concrete barrier walls. The Barrier
Wall Control Joint is installed by mechanically attaching it
to the edge of the concrete form at a predetermined joint
spacing specified by the engineer. The spacing and location
of the Barrier Wall Control Joint is calculated based on
the concrete mass and length of wall cast. Comes as a 3
metre (10') length. Available in steel as a special order upon
request.

NOTE: If properly installed may be reused a number of times. Referred in


the OPSS904 specification as special provision 109S25. ¾" Plywood

To order, please specify


the following information
EXAMPLE
Name ........ Barrier Wall Control Joint
Quantity ..................................... 200

Barrier Wall
Control Joint

Expanded Metal Form

AR Expanded Metal Form is adaptable to site conditions for Collar of 1 X 6 for


stay-in-place forming. Use in applications such as bulkheads, above grade finish

blind sided walls, grade beams and pile caps. Expanded Metal
Rod ties sized
Form reduces labour costs in difficult forming applications. to suit
Supplied pre-galvanized for job site storage.
ACCESSORIES
FORMING
GENERAL

Expanded Metal Form sheet size:


685 mm x 244 mm (27" x 8'-0")

APPENDIX
For corners, notch ribs 3/8" Wire-tie all laps and
deep with "V" contoured back with supports.
rotary cut-off blade and
bend to 90 degrees. 90˚

Rod clamps
securing ties
To order, please specify the following information
Wood strong backs
EXAMPLE spaced and sized
Name ................................... Expanded Metal Form to suit load
Quantity ................................................. 10 sheets

94 95
GENERAL GENERAL
GUIDELINES & GUIDELINES &
CONDITIONS CONDITIONS

General Guidelines and Conditions General Guidelines and Conditions

Approximate Safe Working Loads: The Approximate Safe Working Loads published in this brochure can only be Ty cones and metal washers are
obtained when AR products and accessories are used together. Products must be installed correctly to obtain the used to act as form spreaders only. Metal washers will bend and
plastic cones will shatter
full strength development as illustrated below. The wedge should not be
overtightened by any method.
Ensure that internal vibration has Attempting to draw-up warped
not caused Snap-Ty Wedges to Wedge properly positioned Improperly positioned wedges
wales with the wedge should not be
will loosen and fall off
bounce around, loosen or fall off. attempted. Metal spreader washers
It is important to properly will bend out of shape and plastic
position the Snap-Ty head and cones will break if over tightening
the wedge. is attempted, resulting in incorrect
wall thickness.
Ty is at midpoint of wedge slot
Ty is too high in the wedge slot

CORRECT

CORRECT
The Ty Head must not be To achieve proper form structures,
The ty head must be positioned at the Ty wedge positioned too high
positioned lower than the midpoint it is important that all form tys are
midpoint (or higher) of the wedge slot.
of the wedge. The proper Ty Head installed and used properly.
position is at the midpoint of the Excessive loads will be transferred
wedge slot, or higher. to adjacent tys and can result in form
failure if tys and/or their required
hardware are omitted.
Midpoint
of Ensure that form tys are properly
wedge slot aligned. Increased loads placed
Ty Head on form tys because of
misalignment may cause form Tys have
failure to occur. Also, reduced been
load capacities can result from left out
Wedge The ty head must not be positioned lower
than midpoint of the wedge slot. form tys damaged because of
misalignment during installation.
CORRECT

Walers spaced too far apart may


cause crushing of the wales or Break Back Walers will become damage

CONDITIONS
CONDITIONS

GUIDELINES
GUIDELINES

GENERAL
GENERAL

bending of the wedge, causing


the form to bulge outward.
Incorrect wall thicknesses will
result and cause the Ty Spreader
Washers or Cones to become CORRECT
embedded in the concrete.
Embedded Ty Washers or Cones
will make it difficult to break
back the Tys.
Correct spacing between walers is Walers are Spreader washer
15 to 20 mm (5/8” to 3/4”) too far apart or cone embedded
in concrete
CORRECT
96 97
GENERAL GENERAL
GUIDELINES & GUIDELINES &
CONDITIONS CONDITIONS

General Guidelines and Conditions General Guidelines and Conditions

The maximum space between Do not force tys into position.


double walers should be 13 mm (½") Forcing the tys may damage
more than the nominal diameter the ty and result in form failure.
of a forming device being used Do not use incorrect length Tys
ie He-Bolts, Taper-Tys, She-Bolts and do not mix incorrect form
and Lagstud Bolts. Ty lengths with correct ones.
Doing so will cause a transfer of Liquid Concrete
lateral pressure to adjacent tys Liquid Concrete:
and may result in form failure. Full hight
of the form
Do not use the form tys for climbing.
Impact wrenches should not be
used to tighten form tying devices.
Do not vibrate the concrete Concrete is properly
excessively or the concrete at stiffened and lateral
the bottom of the form will stay pressure is reduced.
in liquid state longer than should
be expected. The liquid state will
cause a higher than expected
lateral form pressure and could
cause a form failure. CORRECT
CORRECT
The recommended rate of placement
Wales may be crushed or washers should not be exceeded. If the
may bend if too much space is allowed Walers will become demaged concrete at the bottom of the form is
between the walers. Too much space still in liquid state do not continue to
causes the form to move outward and place concrete. Form failure may result.
will result in incorrect wall thickness Working parts below the specified
and spreader cones becoming trapped requirements should not be used
in the concrete. Incorrect wall thickness with forming accessories.
can also be caused from washers Washer
Use accessories and hardware
being deflected due to the increased Walers are Cone embedded
of proper length, diameter and
too far apart in concrete
lateral form pressure. capacity. If it is necessary to use
CORRECT a greater safety factor, the safe Actual rate
working load must be reduced of placement
accordingly.
Lag stud bolts and other lag thread
products must have proper lag Use caution when welding any
forming system component.

CONDITIONS
penetration. A minimum of one
CONDITIONS

GUIDELINES
GUIDELINES

GENERAL
GENERAL

Unsufficient coil
diameter of the bolting device past penetration
Material properties may be
Recommended
the coil is the proper penetration. affected by welding and result
See chart for rate of
As an example, a lagstud bolt that minimum coil in lower product performance. placement
is 25 mm (1") in diameter should extend
penetration A good working knowledge of
a minimum of 25 mm (1") past the coil. materials, heat treating and
Form failure can result if threaded items welding procedures is required
Part Failure
are penetrated incorrectly. Excessive wear before welding any forming
Bolt
on the bolt’s first few threads are caused Diameter
accessory. National Concrete
from improper penetration and the entire Accessories does not guarantee
bolt load is placed on a smaller portion any product altered in any way
of the coil welds. The coil welds can fail
CORRECT after leaving the factory.
and cause form failure because of this
increased load.
98 99
INDUCED SNAP-TYS
TENSION STRIPPING
LOADS & BREAK BACK

Induced Tension Loads Stripping of Snap-Tys and guidelines for break back

Induced Tension Loads AR Snap-Ty break backs are manufactured to exacting standards
Pressure
When tying at an angle be aware that that ensure that they perform to load requirements while providing
Angle
an increase in the tension applied to an Angle Multiplication Factor a consistent and reliable breaking point. However, many factors
angled ty is increased. Sample angles 15º 1.04 affect the performance of the break backs.
and the corresponding multiplication 30º 1.16 Ten
sio
factors for calculating the tension load 45º 1.42 n · Snap-Tys must not be bent during installation as the break back
on an angled ty are shown in the table. 60º 2.00 could be adversely affected.
· For best results, Tys are not to be removed until concrete has
gained sufficient strength to prevent the Ty upset from rotating —
typically 2 to 3 days. Attempting to break the Ty in green concrete
may result in the Ty rotation in the concrete and make it difficult to
break the Ty.
Induced Shear Loads · Only Space-Tys have a guaranteed break back.
· Other Snap-Ty products are designed to provide a consistent
break back, but can be affected by the concrete, which could
It is important to note the .71 X tie down load = shear load generate difficulties in achieving a consistent break back.
illustration showing ty downs · Products like the Steel Washer, No Washer and No Spreader
placed at an angle and the shear Snap-Tys where the break back could be contained within the
loads produced. Total shear load concrete require extra attention. With increased bond length AR
may be many times greater than 45˚ cannot guarantee that the Ty will consistently provide the proper
the shear load produced by the break back. For these products, this is especially important where
form weight alone. .50 X tie down load = shear load break backs of over ¾" (20 mm) are desired. A good quality
When deciding which form ty release agent/grease (acceptable non-staining) applied between

Te
ns
system to use for a forming the break back and the face of formwork (grease wire to be

ion
30˚

Tie
application, consider both the embedded, that will be removed — do not grease head area) may

Do
tension and the shear load.

wn
facilitate more consistent results. On site tests should be
.26 X tie down load = shear load Space-Ty Wrench

Lo
conducted to identify if consistent results can be achieved with

ad
15˚
the concrete mix and Ty.
· If the washer or cone is not free of the concrete, chip away
the concrete using a hammer, screwdriver or drill to free the
embedded components. Failure to free up the embedded
Total shear load components could result in the break back closer to the
surface of the concrete instead of the desired break back
location.

Use of the AR Snap-Ty and Space-Ty wrenches will assist


Combined Shear and Tension Loads with consistency, reduce risk of injury and speed up removal
(see pages 22 and 23).

The equation shown should be If in doubt, contact AR’s technical department for assistance.
satisfied for form accessories

BREAK BACK
STRIPPING &
and inserts subjected to combined

SNAP-TYS
INDUCED
TENSION
LOADS

shear and tension loading.

5 5

( ) ( )
3 3
ft fv < 1.0 Where:
+
Ft Fv
=
ft = induced tension load Snap-Ty Wrench
Ft = insert tension Approximate Safe Working Load or bolt tension Approximate Safe
Working Load, whichever is less
fv = induced shear load
Fv = insert shear Approximate Safe Working Load or bolt shear Approximate Safe Working
Load, whichever is less

100 101
CONCRETE CONCRETE
LATERAL LATERAL
PRESSURES PRESSURES

Concrete lateral pressures for wall form design - PUMPED Concrete lateral pressures for wall form design - BUCKET

— Table conforms to CAN/CSA-S269.3-M92. — Table conforms to CAN/CSA-S269.3-M92.

PUMPED BUCKET
CONCRETE TEMPERATURE DURING POUR CONCRETE TEMPERATURE DURING POUR
Rate of pour 5° C (40° F) 10° C (50° F) 15° C (60° F) Rate of pour 5° C (40° F) 10° C (50° F) 15° C (60° F)
kPa PSF kPa PSF kPa PSF kPa PSF kPa PSF kPa PSF
1 metre per hour 3'0" per hour 86 1810 72 1500 62 1290 1 metre per hour 3'0" per hour 69 1450 58 1200 50 1030
1.5 metre per hour 4'0" per hour 92 1900 77 1550 67 1325 1.5 metre per hour 4'0" per hour 74 1520 62 1240 54 1060
2 metres per hour 5'0" per hour 99 1975 82 1625 71 1410 2 metres per hour 5'0" per hour 79 1580 66 1300 57 1130
2.5 metres per hour 6'0" per hour 106 2075 88 1680 76 1460 2.5 metres per hour 6'0" per hour 85 1660 71 1350 61 1170
3 metres per hour 7'0" per hour 112 2125 93 1760 81 1525 3 metres per hour 7'0" per hour 90 1700 75 1410 65 1220
3.5 metres per hour 8'0" per hour 2250 132 1840 113 1590 3.5 metres per hour 8'0" per hour 128 1800 106 1470 91 1270
4 metres per hour 9'0" per hour 2331 144 1910 128 1640 4 metres per hour 9'0" per hour 144 1870 120 1530 103 1310
4.5 metres per hour 10'0" per hour 2425 1975 144 1675 4.5 metres per hour 10'0" per hour 1940 134 1580 115 1340

CONCRETE TEMPERATURE DURING POUR CONCRETE TEMPERATURE DURING POUR


Rate of pour 20° C (70° F) 25° C (80° F) 30° C (90° F) Rate of pour 20° C (70° F) 25° C (80° F) 30° C (90° F)
kPa PSF kPa PSF kPa PSF
kPa PSF kPa PSF kPa PSF
1 metre per hour 3’0” per hour 48 1000 48 1000 48 1000
1 metre per hour 3'0" per hour 48 1000 48 1000 48 1000
1.5 metre per hour 4’0” per hour 48 1000 48 1000 48 1000
1.5 metre per hour 4'0" per hour 58 1000 48 1000 48 1000
2 metres per hour 5’0” per hour 51 1000 48 1000 48 1000
2 metres per hour 5'0" per hour 63 1130 48 1000 48 1000
2.5 metres per hour 6’0” per hour 54 1030 48 1000 48 1000
2.5 metres per hour 6'0" per hour 67 1290 51 1000 48 1000
3 metres per hour 7’0” per hour 57 1080 51 1000 48 1000
3 metres per hour 7'0" per hour 71 1350 63 1130 51 1000
3.5 metres per hour 8’0” per hour 80 1120 71 1010 65 1000
3.5 metres per hour 8"0' per hour 100 1400 88 1260 81 1000
4 metres per hour 9’0” per hour 90 1150 81 1030 73 1000
4 metres per hour 9'0" per hour 112 1440 101 1290 91 1000
4.5 metres per hour 10’0” per hour 101 1170 90 1040 81 1000
4.5 metres per hour 10'0" per hour 126 1460 112 1300 101 1000
NOTES: The above table is controlled rate of pours (concrete using type 10 or 30 cement, with no NOTES: The above table is controlled rate of pours (concrete using type 10 or 30 cement, with no
admixtures, ie. superplasticizer) plus 25% for pumped concrete. admixtures, ie. superplasticizer).
PRESSURE

PRESSURE
LATERAL

LATERAL
102 103
MAXIMUM MAXIMUM
LATERAL LATERAL
PRESSURES PRESSURES

Maximum lateral pressure for design of COLUMN FORMS Maximum lateral pressure for design of WALL FORMS

— Based on ACI Committee 347 pressure formula — Based on ACI Committee 347 pressure formula

Applies only for normal weight concrete made with type 1 cement, no admixtures or pozzolans, slump no more than Applies only for normal weight concrete made with type 1 cement, no admixtures or pozzolans, slump no more than
4 inches and vibration depth limited to 4 feet or less. 4 inches and vibration depth limited to 4 feet or less.

P. maximum lateral pressure, psf, for temperature indicated. P. maximum lateral pressure, psf, for temperature indicated
Rate of placement 40° F 50° F 60° F 70° F 80° F 90° F Rate of placement 40° F 50° F 60° F 70° F 80° F 90° F

1 foot per hour 1 foot per hour


2 feet per hour 2 feet per hour 600 psf
600 psf minimum minimum
3 feet per hour 825 690 3 feet per hour 825 690 governs
governs
4 feet per hour 1050 870 750 664 4 feet per hour 1050 870 750 664
5 feet per hour 1275 1050 900 793 712 650 5 feet per hour 1275 1050 900 793 712 650
6 feet per hour 1500 1230 1050 921 825 750 6 feet per hour 1500 1230 1050 921 825 750
7 feet per hour 1725 1410 1200 1050 938 850 7 feet per hour 1725 1410 1200 1050 938 850
8 feet per hour 1950 1590 1350 1178 1050 950 8 feet per hour 1795 1466 1246 1090 973 881
9 feet per hour 2175 1770 1500 1307 1163 1050 9 feet per hour 1865 1522 1293 1130 1008 912
10 feet per hour 2400 1950 1650 1436 1275 1150 10 feet per hour 1935 1578 1340 1170 1043 943
12 foot per hour 2850 2310 1950 1693 1500 1350 NOTE:Form pressure is based on concrete weighing 150 lb/ft2.
14 feet per hour 2670 2250 1950 1725 1550 Do not use design pressures in excess of 150 x height of fresh concrete in forms.

16 feet per hour 3000 2550 2207 1950 1750


18 feet per hour 2850 2464 2175 1950
ACISpec CAN/CSA-S269.3-M92
20 feet per hour 3000 2721 2400 2150 Wall up to 7 feet 150 = (9000*R)/T
150 + (43400/T) = (2088*R)/T
22 feet per hour 2979 2625 2350 Wall between 7 and 10 feet 150 + (43400/T) = (2088*R)/T
Maximum form pressure 2000 PSF 3000 PSF
24 feet per hour 3000 2850 2550 Miminum form pressure 600 PSF 1000 PSF
26 feet per hour 3000 2750 Up to 4'-0" wall 600/150 = 4 feet Full Liquid Head Pour Full Liquid Head
28 feet per hour 2950 Comments ACI formula for pour rate up to Higher form pressure
7 feet/hour is more conservative between 0 to 7 feet/hour
30 feet per hour 3000 psf maximum 3000 Lower maximum form pressure Higher maximum form pressure
governs
Lower miminum form pressure Higher minimum form pressure
NOTE:Form pressure is based on concrete weighing 150 lb/ft2.
Do not use design pressures in excess of 150 x height of fresh concrete in forms.
PRESSURE

PRESSURE
LATERAL

LATERAL
104 105
LATERAL LIGHT
PRESSURE FORMWORK

Lateral Pressure Light Formwork

Wall Thickness As Concrete Cures Typical 3050mm (10'-0") High Wall Formwork, Typical 3050 mm (10'-0") High Wall Formwork,
CONTROLLED RATE OF POUR FULL LIQUID HEAD
Snap-Ty Wall
Wall Form pressure kPa (PSF) Snap-Ty
150 mm 300 mm 600 mm Concrete in Once bottom Once second foot of Form pressure kPa (PSF)
thickness W6
thickness
10 kN (2,250 lbs) 10 kN (2,250 lbs)
(6') (12') (24') plastic state foot is cured concrete is cured 0 (0) 0 (0)
W5 spacing: spacing:
Millimeters PSF KPa PSF KPa PSF Feet W1, W2 and W3 W1, W2 and W3

(2'-0")
3,000 10'

610
@ 305 (12") @ 305 (12")

610 (2'-0")
150 68 150 68 150 W5
2,700 9' on centre on centre
300 136 300 136 300
W4
2,400 8'

2032 (6'-8")
W4 and W5 W4 @ @ 406

(2'-0")
450 204 450 204 450

610
2,100 7' @ 610 (2'0") (1'-4") on centre

610 (2'-0")
W4
600 272 600 272 600
on centre

3050 (10'-0")
1,800 6' W5, W6

3050 (10'-0")
750 340 750 340 750 W3
1,500 5' Space-Ty TM @ 610 (2'-0")

(2'-0")
610
900 408 900 408 13.4 kN (3,000
900
on centre

610 (2'-0")
1,200 4' W3
1050 476 476 1050 48 lbs) spacing:
900
1050
3' W2 Space-Ty TM
W1, W2 and W3

(1'-4")
1200 544 544 1200 (1000) 13.4 kN (3,000

406
1200 W2
600 2' @ 406 (1'-4")
680 680 lbs) spacing:

610 (2'-0")
1350 1350

1018 (3'-4")
68 Kg 68 Kg 68 Kg
300 1' A on centre A
W1, W2 and W3

(1'-4")
(150 lbs) (150 lbs) (150 lbs)

406
1500 748 748 W1 B W1 G
W4 and W5 C
@ 406 (16")
C
D
@ 610 (2'-0") 72 D on centre
48
on centre E
Plastic concrete exerts the same pressure on (1000)
E (1500) W4, W5 and W6

(10")
MAX.
250
(10")
MAX.
250
F @ 610 (2'-0")
forms regardless of their width. Lateral pressure decreases from bottom as concrete cures. F
on centre
Typical 6100 mm (20'-0") High Wall Formwork, Typical 6100 mm (20'-0") High Wall Formwork,
CONTROLLED RATE OF POUR FULL LIQUID HEAD
Wall Wall
Form pressure kPa (PSF) Form pressure kPa (PSF) thickness
thickness
Increased Wall Height As Concrete Cures 0 (0)
0 (0) W13 Snap-Ty Space-Ty TM
W15
10 kN (2,250 lbs) 13.4 kN (3,000
Millimeters Feet PSF KPa Concrete in Once bottom Once second foot of spacing: lbs) spacing:

(2'-0")
610

(2'-0")
plastic state foot is cured concrete is cured W12

610
3,000 10' W1 to W10 @ 305 W14 W1 to W12 @ 305
150 68 Millimeters PSF KPa PSF KPa PSF Feet (12") on centre (12") on centre
2,700 9'

(2'-0")
3,000 10'

610
3050 (10'-0")
136

(2'-0")
300
W11 W11 @ 406 W13 @ 406 (1'-4")

610
150 68 150 68 150
2,400 8' 2,700 9' W13
450 204 300 136 300 136 300 (1'-4") on centre on centre
2,100 7' 8'

(2'-0")
2,400

610

(2'-0")
600 272 W10 W12 and W13 W14 and W15

610
450 204 450 204 450
1,800 6' 2,100 7' W12
750 340 @ 610 (2'-0") @ 610 (2'-0")
272 272

(1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4") (1'-4")


600 600 600 W9

406 406 406 406 406 406 406 406 406


1,500 5' on centre on centre

(1'-0") (1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0")(1'-0") (1'-4") (1'-4")


1,800 6' W11

305 305 305 305 305 305 305 305 305 406 406
900 408
750 340 750 340 750

6100 (20'-0")
1,200 4' 1,500 5' Space-Ty TM

6100 (20'-0")
476 W8
1050 900 408 900 408 900 72 W10
900 3' 1,200 4' 13.4 kN (3,000
1200 544 476 476
(1500) W7
600 2'
1050 1050 1050 lbs) spacing: W9
680 900 3'
1350 1200 544 1200 544 1200
W6
W1 to W11 W8
300 1' 600 2'
1500
748
1350 680 1350 680
@ 457 (1'-6")
W7
300 1' W5 on centre
1500 748 748 W6
W12 and W13

3050 (10'-0")
W4
@ 610 (2'-0") W5
As you increase the height of plastic concrete SEE LEGEND
W3 A on centre W4 A
to the forms, the pressure will build at a rate ON PAGE 109
of 150 PSF per foot of depth. This will be true Lateral pressure decreases from bottom as concrete cures. W2
G W3 H

C SEE GENERAL
as long as all concrete remains in a plastic state. W2
C NOTES ON
W1 D
W1 D
E
144 E
PAGE 109
Example: Ten feet of fluid or plastic concrete 72

250 (10")
(3000)

MAX.
150
(6")
(1500)

MAX.
bears on the bottom foot of forms with a

FORMWORK
PRESSURE

F
LATERAL

LIGHT
pressure of 10 X 150 lbs/ft3 or 1500 PSF.
CHART — MAXIMUM RISE OF CONCRETE IN FORMS IN METRES (FEET) PER HOUR
Liquid Head 5°C (40°F) 10°C (50°F) 15°C (60°F) 20°C (70°F) 25°C (80°F)
3050 mm (10'-0") High Wall, Controlled Rate of Pour N/A N/A N/A N/A 1 (3) 2 (5) 3.5 (8)
3050 mm (10'-0") High Wall, Full Liquid Head N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
6100 mm (20'-0") High Wall, Controlled Rate of Pour N/A N/A N/A N/A 2 (6) 3.5 (8) 4.5 (10)
6100 mm (20'-0") High Wall, Full Liquid Head N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

106 107
MEDIUM HEAVY
FORMWORK FORMWORK

Medium Formwork Heavy Formwork

Typical 3050 mm (10'-0") High Wall Formwork, Typical 3050 mm (10'-0") High Wall Formwork, Typical 6100 mm (20'-0") High Wall Formwork Typical 6100 mm (20'-0") High Wall Formwork,
CONTROLLED RATE OF POUR
TY and WALER OPTIONS FULL LIQUID HEAD CONTROLLED RATE OF POUR FULL LIQUID HEAD
Wall Wall Option #1 Option #2
Form pressure kPa (PSF)
thickness
Tyscru spacing Form pressure kPa (PSF) Option #1 Option #2
thickness
W4 Form pressure kPa (PSF)
0 (0) W4
Waler T2 T2 T2 T2 0 (0) Form pressure kPa (PSF) T6 T7
T6 T7
Options 4.5 M 6.75 M 9 M 18 M 0 (0)
0 (0)

914 (3'-0")
LAYOUT and TY OPTIONS:

914 (3'-0")

1220 (48")
1220 (4'-0")
914 (3'-0")

3050 mm (10'-0") High Wall 6100 mm (20'-0") High Wall

(4'-0")
1220
T5
Controlled Rate of Pour
2032 (6'-8")

Controlled Rate of Pour T5


W3 Diameter of Ty Options T6
Two 89x89 610 T6 Layout
- - -

1220 (4'-0")
3050 (10'-0")
W3
(4x4) (2'-0") Options Tyscru Taper Ty

3050 (10'-0")

1220 (4'-0")
3050 (10'-0")

914 (3'-0")
762 (2'-6")

Two Aluminum 762 Option - 25 - 32

(3'-0")
- - - T4-27M

914
762 (2'-6")
Channel Beams (30") #1 - (1"-1¼") T4 T5
W2 T4 T5
48 Two C4 914 1220 W2 Option 20 - 25 25 - 32
- - T4-18M

914 (3'-0")
(1000) x 5.4 lb/ft (36") (48") #2 (¾"-1") (1"-1¼")

1220 (4'-0")
762 (2'-6")

6100 (20'-0")
1220 (4'-0")

(3'-0")
610 (2'-0")

914
A A
1018 (3'-4")

6100 (20'-0")
T4
I M 72
W1 W1 T4
J
3050 (10'-0") mm High Wall J (1500) T3

914 (3'-0")
K Full Liquid Head K
T3 6100 mm (20'-0") High Wall
48 72
Full Liquid Head

(3'-0")
Two 89x89 457 610

914
L L

1220 (4'-0")
- - (1500) T3

(10")
(1000)

250
(10")
MAX.

MAX.
250

(4x4) (1'- 6") (2'-0") Layout Diameter of Ty Options

1220 (4'-0")
F F T3
A
Two Aluminum 762 Options Tyscru Taper Ty

914 (3'-0")
- - -

3050 (10'-0")
Channel Beams (2'-6") A Option 25 - 32 T2
T4-27M -

(3'-0")
Typical 6100 mm (20'-0") High Wall Formwork, T2
#1 (1"-1¼")

914
Typical 6100 mm (20'- 0") High Wall Formwork, T2
Two C4 914 1220
CONTROLLED RATE OF POUR - - FULL LIQUID HEAD R

1220 (4'-0")
Wall T2
Wall
x 5.4 lb/ft (3'-0") (4'-0") Option 20 - 25 25 - 32
Form pressure kPa (PSF) Form pressure kPa (PSF) thickness T4-18M

1220 (4'-0")
thickness

914 (3'-0")
W9 W14 #2 (¾"-1") (1"-1¼")
O
0 (0) 0 (0)

(3'-0")
S

914
6100 (20'-0") mm High Wall T1 T1
P

(30")
762
Controlled Rate of Pour T1 T1 144 Q

200 (8")
W13
(4'-0")
1220

MAX.
72 (3000)
Two 89x89 457 610

200
Q

(8")
- -

MAX.
(1500)

200
(8")
(4x4) (1'-6") (2'-0")

200
(8")
(2'-0")
610
W8 F
3050 (10'-0")

W12
Two Aluminum 762 F
- - -
Channel Beams (2'-6")
(2'-6")

LEGEND A = 19mm (¾") plywood B = 38X89 (2X4) studs @ 200 (8") on centre C = Two 38X89 (2x4) walers D = Tywedge (sweg-H)
(2'-0")
762

610

W11
W7
Two C4 914 1220 E = Snap-ty or Space-TyTM F = Footing G = 38X89 (2x4) studs @ 150 (6") on centre H = 38X89 (2x4) studs @ 100 (4") on centre
- - I = 89X89 (4x4) studs @ 250 (10") on centre J = Double waler K = Lagstud bolt, Washer and Nut L = Cone-Tight Tyscru
(1'-6") (1'-6")

x 5.4 lb/ft (3'-0") (4'-0")


457

W10
M = 89X89 (4x4) studs @ 200 (8") on centre N = 89X89 (4x4) studs @ 150 (6") on centre O = Aluminum horizontal walers @ 254 (10") on centre
(2'-0")
610

W6
P = Double strongbacks @ 1220 (4'-0") on centre Q = Form-ty (refer to Laout Options in table above)
6100 (20'-0")

6100 (20'-0")

457

W9
72
6100 (20'-0") mm High Wall R = Aluminum beam or CB walers @ 200 (8") on centre S = Double strongbacks @ 610 (2'-0") on centre
(2'-0")
610

(1500)
(1'-0") (1'-0")(1'-0")(1'-0") (1'-4") (1'-4") (1'-4") (1'-6")

W5 Full Liquid Head


457

W8
Two 89x89 457 610 CHART — MAXIMUM RISE OF CONCRETE IN FORMS IN METRES (FEET) PER HOUR
- -
(2'-0")

305 305 305 305 406 406 406


610

(4x4) (1'-6") (2'-0") W7


W4 Liquid Head 5°C (40°F) 10°C (50°F) 15°C (60°F) 20°C (70°F) 25°C (80°F)
Two Aluminum 762 W6 6100 mm (20'-0") High Wall, Controlled Rate of Pour N/A N/A N/A N/A 2.5 (6) 3.5 (8) 4.5 (10)
- - -
(2'-0")

Channel Beams (2'-6")


3050 (10'-0")

610

W3 6100 mm (20'-0") High Wall, Full Liquid Head N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
W5
Two C4 914 1220
A - - A
x 5.4 lb/ft (3'-0") (4'-0")
(2'-0")

W4
610

M
W2
J N
NOTES: 5) Wood design is based on CAN3-086-M84 to 70° F, 1.5 hours @ 50° to 60° F, 1 hour @
W3
K J
1) All lumber to be SPF, No. 2 grade or equal Engineering Design in Wood (working stress 70° to 80° F
except for 4"x4"s and 2"x4"s to be SPF, design). Wallform and product design is based on
(2'-0")

SEE LEGEND ON PAGE 109 W2


610

W1 L
W1 K construction grade or equal. 6) Formwork design based on CAN/ the following assumptions:
72
SEE GENERAL NOTES 144 2) Construction live load not to exceed: CSAS269.3- M92 concrete formwork — — Concrete is placed by bucket from top
FORMWORK

FORMWORK
L
ON PAGE 109
MEDIUM

· 75 PSF (3.6 KPa) on deck National Standard of Canada. of form (not pumped)

HEAVY
(1500) (3000)
(10")
250

150
(6")
MAX.
MAX.

F F
· 50 PSF (2.4 KPa) on work platform Wallform Pouring Information Form — Concrete pressures are full liquid head
CHART — MAXIMUM RISE OF CONCRETE IN FORMS IN METRES (FEET) PER HOUR 3) Contractor to verify with structural Tys are spaced for maximum concrete unless a maximum concrete pressure is
engineer the capacity of structure to sustain pressure of 1500 PSF at safe load specified above
Liquid Head 5°C (40°F) 10°C (50°F) 15°C (60°F) 20°C (70°F) 25°C (80°F) imposed loads. values of Tys. Assumed pouring rate for — Concrete mix using type 10 or type 30
3050 mm (10'-0") High Wall, Controlled Rate of Pour N/A N/A N/A N/A 1 (3) 2 (6) 3.5 (8) 4) Wallform concrete pour design based “Portland Cement” concrete only at various cements maximum slump of 100mm (4") for
3050 mm (10'-0") High Wall, Full Liquid Head N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A on full liquid head pressure (unrestricted temperatures as indicated in above charts. controlled pours
6100 mm (20'-0") High Wall, Controlled Rate of Pour N/A N/A N/A N/A 2.5 (6) 3.5 (8) 4.5 (10) rate of pour) unless indicated otherwise at Estimated time of set for charts: — Compliance with “Concrete Formwork”
6100 mm (20'-0") High Wall, Full Liquid Head N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A pouring information below. 1.75 hours @ 40° to 50° F, 1.25 hours @ 60° standard CAN/CSA-S269.3-M92

108 109
SAFE SAFE
WORKING WORKING
LOADS LOADS

Approximate Safe Working Loads & Ultimate Capacities calculated for various concrete strengths Approximate Safe Working Loads & Ultimate Capacities calculated for various concrete strengths

3.4 MPa (500 psi)


3.4 Concrete
MPa (500Strength
psi) Concrete Strength 4.8 Concrete
4.8 MPa (700 psi) MPa (700Strength
psi) Concrete Strength 10.3 MPa (150010.3
psi) MPa (1500Strength
Concrete psi) Concrete Strength
Safe Working Load
Safe2:1
Working Load 2:1 Ultimate Ultimate Safe2:1
Safe Working Load Working Load 2:1
Ultimate Ultimate Safe2:1
Safe Working Load Working Load 2:1
Ultimate Ultimate
Type of Anchor Type of Anchor Anchor Dimension
Anchor Dimension kN lbs
kN lbs kN lbs
kN lbs kN lbskN lbs
kN lbskN lbs kN lbs kN lbs
kN lbskN lbs

Tyloop Tyloop Tyloop Tyloop


Flared Flared
25 x 375 25
1" xx 375
15" 1" x 15" 66 15,00066 15,000
133 133
30,000 30,000
4 strut 4 strut
25 x 450 25
1" xx 450
18" 1" x 18" 75 17,00075 17,000
151 151
34,000 34,000

Flared 4-strut Flared


324-strut
x 375 32 x 375
1¼" x 15" 1¼" x 15" 66 15,00066 15,000
133 133
30,000 30,000
and Offset and Offset
32 x 450 32 x 450
1¼" x 18" 1¼" x 18" Not recommended
Not recommended
in weak concrete
in weak concrete Not recommended
Not recommended
in weak concrete
in weak concrete 75 17,00075 17,000
151 151
34,000 34,000

Offset Offset32 x 600 32 x 600


1¼" x 24" 1¼" x 24" 106 106
24,000 24,000
213 213
48,000 48,000
4-strut 32 x 750
4-strut 32 x 750
1¼" x 30" 1¼" x 30" 133 133
30,000 30,000
266 266
60,000 60,000
32 x 900 32 x 900
1¼" x 36" 1¼" x 36" 133 133
30,000 30,000
266 266
60,000 60,000

Ty-Anchor Ty-Anchor 25 x 300 25


1" xx 300
12" 1" x 12" Not applicableNot applicable 60 13,50060 120
13,500 27,000
120 27,000 Ty-Anchor Consult the National
Ty-Anchor ConsultConcrete
the National
Accessories
Concrete Accessorie
32 x 375 32
1¼"x 375
x 15" 1¼"53x 15" 12,000
53 12,000 68 24,000
68 24,000 68 15,50068 138
15,500 31,000
138 31,000 Technical Department
Technical
(www.nca.ca)
Departmentwhen (www.nca.ca) whe
2-strut 2-strut 2-strut 2-strut
32 x 435 32
1¼"x 435
x 18" 1¼"68x 18" 15,500
68 15,500 137 31,000
137 31,000 86 19,50086 173
19,500 39,000
173 39,000 concrete strengths
concrete
are less
strengths
than 3.4 areMPa
less than 3.4 MPa
32 x 500 32
1¼"x 500
x 20" 100x 20"
1¼" 22,500
100 22,500 200 40,000
200 40,000 120 27,000
120 240
27,000 54,000
240 54,000 (500 psi). Estimated
(500 psi).
practical
Estimated
load values
practical load values
are shown for various
are shown
strengths
for various
of strengths of
4-strut 4-strut
32 x 600 32 x 600
1¼" x 24" 111x 24"
1¼" 25,000
111 25,000 222 50,000
222 50,000 151 34,000
151 302
34,000 68,000
302 68,000
4-strut 4-strut concrete. Safetyconcrete.
factors (ultimate
Safety factors
load: (ultimate load:
working load) isworking
determined
load)atis 2:1.
determined at 2:1.

Crimped Anchor Crimped Anchor 19 x 600 19


¾"x x60024" ¾" 80
x 24" 18,000
80 18,000 160 36,000
160 36,000 80 18,00080 160
18,000 36,000
160 36,000 Crimped Anchor Crimped Anchor
Use lighter anchor
Use unit
lighter
in concrete
anchor unit
above
in concrete above
19 x 750 19
¾"x x75030" ¾" 80
x 30" 18,000
80 18,000 160 36,000
160 36,000 80 18,00080 160
18,000 36,000
160 36,000
4.8 MPA (700 psi)
4.8 for
MPAsame
(700load
psi)capacity.
for same load capacity.
19 x 900 19
¾"x x90036" ¾" 80
x 36" 18,000
80 18,000 160 36,000
160 36,000 80 18,00080 160
18,000 36,000
160 36,000
32 x 1050 32
¾"x x1050
42" ¾" 80
x 42" 18,000
80 18,000 160 36,000
160 36,000 80 18,00080 160
18,000 36,000
160 36,000
Loads based Loads based Loads based Loads based A good formingApracticegood forming
is to preload
practice is to preload
25 x 750 25
1" xx 750
30" 1" x 30" Not applicableNot applicable 120 27,000
120 240
27,000 54,000
240 54,000
on mechanical on mechanical re-anchorage units re-anchorage
to safe working
units toload
safe working load
on mechanical on mechanical
properties only properties only 25 x 900 25
1" xx 900
36" 1"120
x 36" 27,000
120 27,000 240 54,000
240 54,000 120 27,000
120 240
27,000 54,000
240 54,000 properties only properties only prior to pouringprior
lift. Slippage
to pouringwill
lift.indicate
Slippage will indicate
25 x 1050 25
1" xx 1050
42" 1"120
x 42" 27,000
120 27,000 240 54,000
240 54,000 120 27,000
120 240
27,000 54,000
240 54,000
inadequate concrete
inadequate
strength.
concrete
This strength. This
25 x 1200 25
1" xx 1200
48" 1"120
x 48" 27,000
120 27,000 240 54,000
240 54,000 120 27,000
120 240
27,000 54,000
240 54,000
practice is especially
practicecritical
is especially
in concrete
critical in concrete
under 3.4 MPa under
(500 psi).
3.4 MPa (500 psi).
T2 20 xT2
450 20¾"
x 450
x 18" ¾"44x 18" 10,000
44 10,000 88 20,000
88 20,000 92 15,00092 184
15,000 30,000
184 30,000
Tybow Tybow Tybow Tybow
T2 25 xT2
450 25 1"
x 450
x 18" 1"44x 18" 10,000
44 10,000 88 20,000
88 20,000 92 15,00092 15,000
184 30,000
184 30,000
T2 32 xT2
450 32 x 450
1¼" x 18" 1¼"44x 18" 10,000
44 10,000 88 20,000
88 20,000 15,00092 15,000
184 30,000
184 30,000 These are guideThese
figures
aredrawn
guide from
figures drawn from
92
T2 T2 T2 T2 comprehensivecomprehensive
tests and accumulated
tests and accumulated
102 102 data, and performance
data, andwill
performance
vary will vary
T4 32 xT4
450 32 x 450
1¼" x 18" 1¼"60x 18" 13,500
60 13,500 120 27,000
120 27,000 23,000 204
23,000 46,000
204 46,000
153 153 somewhat under somewhat
different under
conditions.
different conditions.
T4 34 xT4
600 34 x 600
1½" x 24" 1½"88x 24" 20,000
88 20,000 177 40,000
177 40,000 30,000 306
30,000 60,000
306 60,000
T4 T4 162 162 T4 T4 For specific jobFor
conditions
specific ajob
check
conditions
test a check test
is recommended is recommended
under field conditions
under field conditions
T6 38 xT6
600 38 x 600
1½" x 24" 120x 24"
1½" 27,000
120 27,000 240 54,000
240 54,000 36,000 324
36,000 72,000
324 72,000
T6 T6 T6 T6 after a selectionafter
is made.
a selection
It is not
is made. It is not
considered desirable
considered
to plan
desirable
canteliver
to plan canteliver
Bow-lag Bow-lag
19 x 600 ¾"19 x 24"
x 600 ¾" x 24" 53 12,000
53 12,000 106 24,000
106 24,000 71 16,00071 16,000
142 32,000
142 32,000 Bow-lag operation
Bow-lag below operation
2.7 MPa below
(400 psi).
2.7 MPa (400 psi).
19 x 750 ¾"19 x 30"
x 750 ¾" x 30" 64 14,500
64 14,500 128 29,000
128 29,000 80 18,00080 160
18,000 36,000
160 36,000 Type 50, cement Type
jobs50,
have
cement
run asjobs
lowhave run as low
22 x 750 7
/8 "22x 30"
x 750 7
/8 " x 30"
88 20,000
88 20,000 177 40,000
177 40,000 102 23,000
102 204
23,000 46,000
204 46,000 as 450 psi @ 7as days.
450Below
psi @ 4007 days.
psi, Below 400 psi,
22 x 900 7
/8 "22x 36"
x 900 7
/8 " x 36"
97 22,000
97 22,000 196 44,000
196 44,000 111 25,000
111 25,000
222 50,000
222 50,000 cycle increasescycle
for 400
increases
psi minimum
for 400 psi minimum
25 x 900 1" 25
x 36"
x 900 1" x 36"
240 54,000
240 54,000 240 54,000
240 54,000 133 30,000
133 30,000
266 60,000
266 60,000 are indicated asaregood
indicated
procedures.
as good procedures.
WORKING

WORKING
LOADS

LOADS
SAFE

SAFE
110 111
CONVERSION CONVERSION
TABLE TABLE

CONVERSIONS CONVERSIONS

CONVERSION CHART METRIC CONVERION FACTORS


Area of rectangle = length x width APPROX. CONVERSION TO APPROX. CONVERSION FROM
Area of triangle = base x 1/2 altitude METRIC MEASURES METRIC MEASURES
Area of parallelogram = base x altitude When You Multiply To When You Multiply To
Area of trapezoid = altitude x 1/2 the sum of parallel sides Know By Find Know By Find
Length Length
Circumference of circle = diameter x 3.1416 inches 2.5 centimetres centimetres 0.4 inches
Diameter of circle = circumference x 0.3183 feet 30.0 centimetres metres 3.3 feet
Radius of a circle = circumference x 0.159155 yards 0.9 metres metres 1.1 yards
Area of a circle = square of diameter x 0.7854 miles 1.6 kilometres kilometres 0.6 miles
Area Area
sq. inches 6.5 sq. centimetres sq. centimetres 0.16 sq. inches
APPROXIMATE WEIGHT OF DRY MATERIALS sq. feet 0.09 sq. metres sq. metres 10.76 sq. feet
Per Per Per sq. yards 0.8 sq. metres sq. metres 1.2 sq. yards
Materials
Cubic Metre Cubic Yard Cubic Foot sq. miles 2.6 sq. kilometres sq. kilometres 0.4 sq. miles
Sand 1600 kg 2700 lbs. 100 lbs. acres 0.4 hectares hectares 2.5 acres
Gravel 1760 kg 3000 lbs. 110 lbs. Mass (weight) Mass (weight)
Crushed Stone 1475 kg 2500 lbs. 92 lbs. ounces 28.0 grams grams 0.035 ounces
Slag 1185 kg 2000 lbs. 74 lbs. pounds 0.45 kilograms kilograms 2.2 pounds
Cinders 770 kg 1300 lbs. 48 lbs. short tons 0.9 metric ton metric ton 1.1 short tons
Limestone 1715 kg 2900 lbs. 107 lbs. Volume (U.S. measure) Volume (U.S. measure)
Cement 1505 kg 2550 lbs. 94 lbs. cubic inches 16.0 millilitres millilitres 0.06 cubic inches
Concrete: fluid ounces 30.0 millilitres millilitres 0.03 fluid ounces
Cinder 1361-1762 kg 2300 - 3000 lbs. 85 -110 lbs. cups 0.24 litres litres 0.036 cups
pints 0.47 litres litres 2.1 pints
Gravel or Limestone 2400 kg 4050 lbs. 150 lbs.
quarts 0.95 litres litres 1.06 quarts
Trap Rock 2485 kg 4200 lbs. 155 lbs. gallons 3.8 litres litres 0.26 gallons
Slag 2240 kg 3800 lbs. 140 lbs. cubic feet 0.03 cubic metres cubic metres 35.0 cubic feet
cubic yards 0.76 cubic metres cubic metres 1.3 cubic yards
CONCRETE ESTIMATOR Pressure
One Cubic Metre of Concrete Will Place p.s.f. 47.8802 Pa Pa 0.020885 p.s.f.
k.s.i. 6.89475 MPa MPa 0.145 k.s.i.
Thickness m2 Ft 2 Thickness m2 Ft 2 Thickness m2 Ft 2 Kips 4.44822 kN kN 0.2248 Kips
25mm (1˝ ) 39.4 424 125mm (5˝ ) 7.9 85 225mm (9˝ ) 4.4 47 Torque
50mm (2˝ ) 19.7 212 150mm (6˝ ) 6.5 70 250mm (10˝ ) 3.9 42 Foot-Pounds 1.35581 Nm Nm 0.73776 Foot-Pounds
75mm (3˝ ) 13.1 141 175mm (7˝ ) 5.6 60 275mm (11˝ ) 3.6 38
Temperature (exact) Temperature (exact)
100mm (4˝ ) 9.8 106 200mm (8˝ ) 4.8 52 300mm (12˝ ) 3.2 35
°F = °C x 9 +32 °C = (°F - 32) x 5
5 9
112 113
CONVERSION CONVERSION
TABLE TABLE

CONVERSIONS CONVERSIONS

CONVERSIONS FACTEURS DE CONVERSIONS MÉTRIQUES


Surface d’un rectangle = longueur x largeur CONVERSIONS APPROXIMATIVES CONVERSIONS APPROXIMATIVES
Surface d’un triangle = base x 1/2 hauteur JUSQU’AUX MESURES MÉTRIQUES À PARTIR DES MESURES MÉTRIQUES
Surface d’un parallélogramme = base x hauteur Si vous Mult. pour trouver Si vous Mult. pour trouver
Surface d’un quadrilatère irrégulier = hauteur x la 1/2 de la connaissez par connaissez par
Longueur Longueur
somme des côtés parallèles les pouces 2.5 les centimètres les millimètres 0.04 les pouces
Circonférence d’un cercle = diamètre x 3.1416 les pieds 30.0 les centimètres les centimètres 0.4 les pouces
Diamètre d’un cercle = circonférence x 0.3183 les verges 0.9 les mètres les mètres 3.3 les pieds
les mètres 1.1 les verges
Rayon d’un cercle = circonférence x 0.159155 les milles 1.6 les kilomètres
les kilomètres 0.6 les milles
Surface d’un cercle = carré du diamètre x 0.7854
Surface Surface
les pouces carrés 6.5 les centimètres carrés les centimètres carrés 0.16 les pouces carrés
POIDS APPROXIMATIF DES MATÉRIAUX SECS les pieds carrés 0.09 les mètres carrés les mètres carrés 10.76 les pieds
Par Par Par les verges carrés 0.8 les mètres carrés les mètres carrés 1.2 les verges carrés
Matériaux
mètre cube verge cube pied cube les milles carrés 2.6 les kilomètres carrés les kilomètres carrés 0.4 les milles carrés
les acres 0.4 les hectares les hectares 2.5 les acres
Sable 1 600 kg 2 700 lb 100 lb
Gravier 1 760 kg 3 000 lb 110 lb Poids (masse) Poids (masse)
les onces 28.0 les grammes les grammes 0.035 les onces
Pierre concassee 1 475 kg 2 500 lb 92 lb les livres 0.45 les kilogrammes les kilogrammes 2.2 les livres
Scories 1 185 kg 2 000 lb 74 lb les tonnes courtes 0.9 les tonnes métriques les tonnes métriques 1.1 les tonnes courtes
Mâchefer 770 kg 1 300 lb 48 lb
Volume Volume
Chaux 1 715 kg 2 900 lb 107 lb les pouces cubes 16.0 les millilitres les millilitres 0.06 les pouces cubes
Ciment 1 505 kg 2 550 lb 94 lb les onces liquides 30.0 les millilitres les millilitres 0.03 les onces liquides
Béton: les tasses 0.24 les litres les litres 0.036 les tasses
mâchefer 1 361- 1 762 kg 2 300 - 3 000 lb 85 - 110 lb les chopines 0.47 les litres les litres 2.1 les chopines
gravier ou chaux 2 400 kg 4 050 lb 150 lb les pintes 0.95 les litres les litres 1.06 les pintes
les gallon 3.8 les litres les litres 0.26 les gallons
basalte 2 485 kg 4 200 lb 155 lb les pieds cubes 0.03 les mètres cubes les mètres cubes 35.0 les pieds cubes
scories 2 240 kg 3 800 lb 140 lb les verges cubes 0.76 les mètres cubes les mètres cubes 1.3 les verges cubes
Pression
ESTIMATION POUR BÉTON lb/po 47,8802 Pa Pa 0,020885 lb/po
Un mètre cube de béton couvrira k/po 2 6,89475 MPa MPa 0,145 k/po 2
Kip 2 4,44822 kN kN 0,2248 kip 2
Épaisseur m2 pi 2 Épaisseur m2 pi 2 Épaisseur m2 pi 2
25mm (1 po) 39.4 424 125mm (5 po) 7.9 85 225mm (9 po) 4.4 47 Torque
50mm (2 po) 19.7 212 150mm (6 po) 6.5 70 250mm (10 po) 3.9 42 livre-pied 1.35581 Nm Nm 0,73776 livre-pied
75mm (3 po) 13.1 141 175mm (7 po) 5.6 60 275mm (11 po) 3.6 38 Température (exacte) Température (exacte)
100mm (4 po) 9.8 106 200mm (8 po) 4.8 52 300mm (12 po) 3.2 35 °F = °C x 9 +32 °C = (°F - 32) x 5
5 9
114 115
CONCRETE CONCRETE
POURING POURING
RATE RATE

Round Fibre Forming Tube - Pouring Rate Tube de Formation de Fibres Rondes - Taux de Coulée

SUGGESTED RATE OF POUR - PER HOUR TAUX DE DIFFUSION SUGGÉRÉ - PAR HEURE

Heavy Wall Light Wall Murs Lourds Murs Léger


Up to 12" ID Pour at any convenient rate Jusqu'à 12" ID Verser à n'importe quel taux convenable
Up to 24" ID 18 ft/hour 15 ft/hour Jusqu'à 24" ID 18 ft/heure 15 ft/heure
Up to 36" ID 11 ft/hour 9 ft/hour Jusqu'à 36" ID 11 ft/heure 9 ft/heure
Up to 42" ID 7 ft/hour 6 ft/hour Jusqu'à 42" ID 7 ft/heure 6 ft/heure
Up to 48" ID 6 ft/hour 5 ft/hour Jusqu'à 48" ID 6 ft/heure 5 ft/heure
Slump should not exceed 6" - max. pour hight on light wall - 12 ft La profondeur ne doit pas dépasser 6 "- max. verser la hauter sur un mur léger - 12 ft

CONCRETE REQUIREMENTS BÉTON EXIGENCES


Cubic Yards Concrete per Cubic Yards Béton par
Tube Diameter Diamètre du Tube
Foot of Column Height ft de hauteur de colonne
6" .0073 6" .0073
8" .0129 8" .0129
10" .0202 10" .0202
12" .0291 12" .0291
14" .0396 14" .0396
16" .0571 16" .0571
18" .0654 18" .0654
20" .0808 20" .0808
22" .0978 22" .0978
24" .1164 24" .1164
26" .1368 26" .1368
28" .1584 28" .1584
30" .1818 30" .1818
36" .2618 36" .2618
48" .4654 48" .4654
For total concrete requirements per column: Pour les besoins totaux en béton par colonne:
take figure beside diameter of tube and multiply by column height. Utiliser la figure à côté du diamètre du tube et multiplier
par la hauteur de colonne.

116 117
GENERAL GENERAL
INFORMATION INFORMATION

GENERAL INFORMATION GENERAL INFORMATION

1. A qualified person must accurately calculate the applied loads and select the appropriate form tying products and PRODUCT SAFETY AND INSTALLATION
determine compatible tie spacings. The approximate safe working loads included in this publication were established based on all items are new or “as
2. In form tying operations, proper installation practices must be maintained. Failure to follow approved practices, new” condition. Inserts are installed correctly and embedded in sound concrete suited for the application so that
such as missing form ties, misalignment of form ties, incorrect form tie lengths, excessive pour rates, etc., can cause the vertical axis of the insert is perpendicular to the lifting surface. Installed hardware shall have full bearing on the
form failure. concrete surface. Caution must be taken to prevent side loading which will cause additional stresses. Attachment and
3. AR recommends the user of the information contained herein and the installer of our products adhere to the erection bolt must be installed using the proper length and penetration to prevent hardware accessories from slippage
Canadian Standards Association CAN /CSA - S269.3 -M92 Concrete Formwork and American Concrete Institute or bending. Caution must be observed and loads not imposed until such time as the concrete strength has reached
-ACI 347 Guide to Formwork. The applied safety factor for a product will depend on the degree of hazard or risk the specified strength required for the insert. Inserts must be properly situated in relation to the edge, corner and
involved in the product application. This safety factor is governed by National Codes, local codes and / or by design openings so as to achieve the full capacity of concrete shear cone. The tensile loads applied to the insert included
professionals. With regards to concrete construction, onsite conditions such as, poor concrete placing technique, both axial and transverse loads transferred to the hardware from crane cables. Impact wrenches are not to be used
concentrated loads on the formwork, improper use of cranes or concrete pumping could increase the degree of for pre cast elements. Welding may cause embrittlement and could result in sudden failure. A metallurgical engineer
risk. If such site conditions exist, the user must increase the safety factor to compensate. For most applications AR must approve the process prior to any welding is undertaken. AR will not warrantee any modification or alterations
suggests a minimum 2:1 safety factor for hanging accessories and stresses that this safety factor should be strictly made to its products.
adhered to or the application be reviewed by a design professional. The material included in this publication indicate
the safety factor for convenience but also provides the ultimate capacities so other safety factors may be used SAFETY FACTOR
where applicable. WARNING: Improper, careless and/or haphazard use of the products shown in this document can The following chart is the suggested Safety Factors used by industry standard for the degree of risk for the
expose workers to extreme danger, injury and death. If uncertain about installations or use of any AR product, contact application. For the precast industry, the degree of risk involved can increase because of the adhesion to the
the nearest AR Sales office or Technical Department for explanations and/or recommendations. National Concrete form, jerking movement, transportation over rough terrain or roads. Safety Factors should be increase to suit the
Accessories products are manufactured according to strict specifications and are subject to numerous tests conditions. The minimum Safety Factors as suggested by OSHA (Occupational Safety and Health Administration),
under a stringent quality control program. These products are designed to be capable of meeting or exceeding all ANSI (American National Standards Institute and the CPCI (Canadian Precast Prestress Concrete Institue) is as
necessary safety requirements for the concrete construction and forming industry. All product test data shown, were followed:
obtained through an independent testing facility or tests conducted by AR. However, the performance of a quality
product can be affected by the manner in which it is used in the field. Therefore, the following precautions should be SAFETY FACTOR INTENDED PRODUCT USE
taken by all involved persons. 2 to 1 Brace Anchors
4. To avoid crushed wales and/or bent Tyholders when using a double waler system, maintain a spacing between the 3 to 1 Permanent Connection
walers comparable to the tie diameter being used plus 13 mm (1/2”). 4 to 1 Insert used for lifting and handling
5. Any welding should be performed by a certified welder. Bending or welding of high tensile steel products should 5 to 1 Hardware used for lifting and handling
not be permitted. Welding of precast accessories can be dangerous and should not be. Note: AR does not warrant
any product that has been welded, altered or modified in any way after leaving an AR plant or warehouse. After For Safety Factors requirement that are different than included in this publications, approximate safe working loads
final inspection of location and alignment, telltale devices should be installed in strategic places on the formwork to must be adjusted by the user. The following equation is used to increase or reduce the approximate safe working load
facilitate detection of formwork movement during concrete placement. During concrete placement, the formwork by the following: SWL + Publication Factor of Safety = New approximate safe working load Required Factor of Safety.
should be continuously monitored by competent persons. These monitors should have a reasonable area of safety
and a means of communicating problems or emergencies to the placement crew. The information contained herein supersedes all previous versions printed prior to this edition and is based on data
6. Never exceed listed product approximate safe working loads. Note that all product load ratings shown in this and knowledge considered true and accurate. AR reserves the right to update information without notice. Please read
bulletin are ratings for new or “as new” products only. Extreme caution must be exercised when using any product all statements, recommendations or suggestions in conjunction with AR’s condition of sale which apply to all goods
that is in other than new condition. Any reusable product that shows wear, misuse, overloading, corrosion or any supplied by AR. No statement, recommendations or suggestions is intended for any use that would infringe
other factor that would compromise its approximate safe working load should be discarded. any patent or copyright.
7. Caution must be exercised when using washer devices to span double wales. Waler gaps are excessive when the
washer device does not bear directly on the primary waler members. NOTE: For applications not specifically identified herein, approval in writing is required by the AR Technical
8. AR products are not to be applied or installed until the user and/or the installer has a clear understanding of the Department for special applications and uses of AR products.
information contained within the appropriate product publication. All contractors must instruct their employees in the
appropriate use and installation of AR products. To avoid injury and possible form tie problems DO NOT CLIMB ON
FORM TIES. Over-vibration or re-vibration will cause lower concrete to remain in a liquid state for an extended period
of time. This can cause excessive lateral form pressure and possible form failure Plumbing of the form, after concrete
placement, should not be attempted. It is virtually impossible to force a form back into position if it is misaligned or
has bulged during concrete placement. Runways for moving equipment should be provided with struts or legs as
required and be supported directly on the formwork or structural member. Formwork must be suitable to support
such runways without intolerable deflection, vibration or lateral movement.
9. Do not interchange products supplied by other manufacturers with those supplied by AR. AR cannot guarantee
that products supplied by others will be compatible and/or interchangeable with AR’s quality concrete accessories.
10.Drawings and/or sketches shown in this bulletin are for illustrative purposes only. Check actual forming conditions
for specific applications. Metric values listed are a soft conversion of imperial values.
118 119
Acrow Richmond specializes in manufacturing hardware and accessories for
the concrete construction industry. With our in-house engineering departments
and over 100,000 square feet dedicated to manufacturing, we produce high
quality Canadian made products.

We manufacture a full line of:

· Concrete forming hardware products for a wide range of forming systems


· Preset Anchoring systems ranging from street signs to high mast light systems
· Precast products for forming, lifting and connecting
· Rock Bolts for reinforcing severe slopes and tunnels
· Bridge deck forming hardware

In addition to a full line of traditional configurations and sizes, we offer


custom fabrication services to meet the most demanding specifications
or creative designs. Our team of experts can work with your project
drawings to provide cost effective solutions that meet your load demands.

AR strives to be your first and only call for all of your construction needs.

You can find Acrow-Richmond products on all National Concrete Accessories


branches across Canada.

For catalogue updates go to:


www.nca.ca

Contact us at:
1-888-777-9272
sales@nca.ca
Social icon

Rounded square
Only use blue and/or white.

For more details check out our


Brand Guidelines.

@NationalConcreteAccessories

Version 3 - August 2018


120