SRP SKID - FOUNDATION BOLT CHECK

MAX LOADS FROM STAAD ANALYSIS

Design code - AISC 360-10


Node No - 970 UNIT Reference
Bolt size = M20
Area of bolt, Ab = 169 mm²
Tensile force, Fy = 60 KN STAAD analysis
Shear force, Fx = 0 KN STAAD analysis
Shear force, Fz = 0 KN STAAD analysis
Resultant Shear force, V = 0.00 KN
Tensile force, T = 60.00 KN
No of bolt, n = 2
Material = Gr 8.8
Yield strength, Fy = 640 N/mm²
futa = min(fu, 1.9*fy, 125 [ksi]) Sec. D.5.1.2
futa = 800 N/mm²
Tensile Strength, Fu = 800 N/mm²
Shear Capacity, Vc = n x Φ x Ab x 0.5 x Fu Eq. D-20
Vc = 101.4 KN
Utility Ratio = 0.00
HENCE SAFE
= V < Vc
Tensile Capacity, Tc = n x Φ x Ab x 0.75 x Futa Eq. D-3
Tc = 152.10 KN
Utility Ratio = 0.39
HENCE SAFE
= T < Tc
Combined Ratio V/Vc+T/Tc = 0.39 < 1.4
= HENCE SAFE