0
Customer Rev. No. 0
Description Designed By
Checked By
Input
Shear Force V= 175 kN.
Axial Force Pu= 1650 kN.
Moment Mu= 376 kN.m
Diametter of Anchor Bolt d= M30 A36
The number of Anchor Bolt n= (4+4) Nos.
Compressive Strength (fc') = 2.5 kN/cm2
Web height (hw)= 550 mm.
Web thickness (tw)= 12 mm.
Flange width (bf)= 450 mm.
Top Flange thickness (tf1) = 25 mm.
Bottom Flange thickness (tf2) = 25 mm.
Base plate thickness (tplate)= 40 mm.
Yeild strength Fy= 34.5 kN/cm2
Base Plate Width (B) = 500 mm.
Base Plate Length (N) = 810 mm.
Numer of bolt colunm at a
2
side
Ultimate strength anchor Fu = 50 kN/cm2
Full stiffener at flange ( stiffener and flange
Yes
= width of plate)
qmax =fp(max) xB
= 69 kN/cm
= 29 cm.
tp(req) = 29.1 mm
t plate = 40 mm>tmin=29.1 mm => Hence safe
Determine the anchor rod size
Since no anchor rod forces exist, use (4+4)M30 A.B
II. Design Procedure for a Large Moment Base.
f = 27.5 cm
= 4624 cm2
2𝑃𝑢 (𝑒 + 𝑓)
= 2403.00 cm2
𝑞𝑚𝑎𝑥
2𝑃𝑢 (𝑒 + 𝑓)
So >=
𝑞𝑚𝑎𝑥 OK
= 20.87 cm
Tu=qmaxY-Pu = -208.49 KN
T bolt = -52.12 KN
At tension interface
x = 7 cm
Maximum moment = -14.03 KNcm/cm
tp(req) = Err:502 mm
Err:502
V 1Bolt = V / n = 21.88 kN
IV. Rod strength from tension & shear combination in case of Large Moment Base Only
ft ≤ min( (𝐹^′ 𝑛𝑡)=[1.3𝐹𝑛𝑡−𝐹𝑛𝑡 /(𝐹𝑛𝑣 )fv], 𝐹𝑛𝑡)
ft = T/𝐴 =
The tensile stress in the anchor rods comes from two sources: Tension from bending & axial tension
The tensile stress, ft = fta + ftb
Where:
fta : axial tension
fta = Pt/A = -7.37 kN/cm2.
ftb : The stress due to bending
Ml/Z (Z=d3/6)
ftb = with
Moment due to shear M l= 45.938 kN.cm
---> ftb = 10.21 kN/cm2
---> ftb =
So, the tensile stress ft = fta + ftb= 2.90 kN/cm2.
fv = 3.10 kN/cm2.
Fnt = 0.75Fu = 37.5 kN/cm2.
Fnv = 0.4Fu = 20 kN/cm2.
𝐹′ 𝑛𝑡 = 30.76 kN/cm2.
𝐹𝑛𝑡 = 28.125 kN/cm2.
Input
Shear Force V= 22 kN.
Axial Force Pa= 95 kN.
Moment Ma= 227 kN.m
Diametter of Anchor Bolt d= M30 A36
The number of Anchor Bolt n= (8+8) Nos.
Compressive Strength (fc') = 1.8 kN/cm2
Web height (hw)= 750 mm.
Web thickness (tw)= 6 mm.
Flange width (bf)= 350 mm.
Top Flange thickness (tf1) = 12 mm.
Bottom Flange thickness (tf2) = 12 mm.
Base plate thickness (tplate)= 30 mm.
Yeild strength Fy= 34.5 kN/cm2
Base Plate Width (B) = 500 mm.
Base Plate Length (N) = 1034 mm.
Numer of bolt colunm at a
2
side
Fu = 50 kN/cm2
Full stiffener at flange ( stiffener and flange
No
= width of plate)
qmax =fp(max) xB
= 31 kN/cm
= 50 cm.
tp(req) = Err:502 mm
Err:502
Determine the anchor rod size
Since no anchor rod forces exist, use (8+8)M30 A.B
II. Design Procedure for a Large Moment Base.
f = 38.7 cm
= 8172.16 cm2
= 1723.97 cm2
So >= OK
= 10.10 cm
Ta=qmaxY-Pa = 214.04 KN
T bolt = 26.76 KN
At tension interface
x = 7 cm
Maximum moment = 7.20 KNcm/cm
tp(req) = 11.81 mm
V 1Bolt = V / n = 1.38 kN
IV. Rod strength from tension & shear combination in case of Large Moment Base Only
The tensile stress in the anchor rods comes from two sources: Tension from bending & axial tension
The tensile stress, ft = fta + ftb
Where:
fta : axial tension
fta = Pt/A = 3.79 kN/cm2.
ftb : The stress due to bending
Ml/Z (Z=d3/6)
ftb = with
Moment due to shear Ml= 2.2 kN.cm
---> ftb = 0.49 kN/cm2