BASE PLATE & ANCHOR BOLT DESIGN FOR PIPE dia 508

LOADING DETAILS
Considering critical loading combinations from STAAD
Case (i) : Max. vertical load and corresponding shear & moments

FY Fx kN Fz kN Mx Mz
kN kNm kNm
Case (i) -164 -45 -45 365 80

PRINCIPLE TOWER SECTION DETAILS


Pipe Section = PIPE 508
outer diameter D = 508 mm
Width B = 508 mm

BASE PLATE DETAILS


outer dia Length d = 900 mm
outer dia Width d = 900 mm
Inner diameter d1 = 508 mm
bolting internal diameter d2 = 800 mm
Assumed base plate Thickness Tp = 32 mm
Strength of plate pyp 275 N/mm2

ANCHOR BOLT DETAILS


Type of bolt = M24
Anchor bolt dia ø = 24 mm
Number of bolts n = 16
Tensile area of bolt At = 361.9 mm2
Tension capacity of bolt Pnom = 88.6 kN (As per Input Data)
Shear capacity of bolt Ps = 11.07 kN (As per Input Data)
Edge distance provided e = 50 mm
Embedded length of bolt La = 750 mm
CONCRETE DETAILS
Grade of concrete = C30
Characteristic compressive strength fcu = 30 N/mm2
Bond coefficient β = 0.3 (BS8110:1997 Table 3.26)
Permissible bearing pressure on conrete wp = 06*fcu
= 18 N/mm2

CHECK FOR BEARING PRESSURE ON CONCRETE


Maximum pressure on concrete = (P/A)+(Mx/Zx)+(Mz/Zz)
= 6.55 N/mm2
< wp SAFE

CHECK FOR THICKNESS OF BASE PLATE


the maximum unit moment (m) in a cantilevered plate subjected to a concented load(P) is given as

= √ -480.9
Base plate Thickness t = 21.9 mm
Assumed B.plate thick > Required Base plate thickness
SAFE

CHECK FOR TENSION IN BOLTS


Moment causing tension on bolts along Z directio = 80 kNm
Lever arm = 800 mm
Direct tension on bolts = -164 kN
Number of bolts in tension side = 8
Push pull force = 100 kN
Total tension on each bolts = 22.75 kN
< Pnom SAFE

Moment causing tension on bolts along X directio = 365.00 kNm


Lever arm = 800 mm
Direct tension on bolts = -164 kN
Number of bolts in tension side = 8
Push pull force = 456.25 kN
Total tension on each bolts = 67.28125
< Pnom SAFE

CHECK FOR SHEAR IN BOLTS


Resultant shear Fs = 63.64 kN
Shear on each bolts = 3.98 kN
< Ps SAFE

CHECK FOR COMBINED SHEAR AND TENSION

(Fs/Ps) + (Ft/Pnom) < 1.4 (BS5950:2000 Cl. 6.3.4.4)


= 1.12
< 1.4 SAFE
CHECK FOR EMBEDDED LENGTH OF ANCHOR BOLT
Design ultimate ahcnorage bond stress fbu = β(fcu)^1/2 (BS8110:1997 Cl. 3.12.8.4)
= 1.64
Maximum tension on each bolts Ft = 67.28 kN
Embedded length required Lreq = Ft/(fbu*PI()*ø)
= 543.06 mm
Provided embedded length of bolt La = 750 mm
> Lreq SAFE

CHECK FOR WELD BETWEEN SECTION & BASE PLATE


Available length of weld Lw = 1596 mm
Design strength of weld pw = 220 N/mm2
Size of weld s = 8 mm
Shear capacity of weld Sw = 0.7*s*pw*Lw
= 1966.2 kN
Actual shear force on weld Fs = 63.64 kN
< Sw SAFE

You might also like