Device information
Device tag Promag
Module name C303
Nominal diameter DN100 / 4"
Device name Promag 300
Order code 5P3B1H-SIMULATION
Serial number SIMULATION
Firmware version 01.05.00
Notes
www.endress.com Page 1
Parameter report
Menu/Operation /
Web server language English
Display language English
Access status Maintenance
Menu/Operation /Display /
Format display 1 value, max. size
Contrast display 50 %
Backlight Enable
www.endress.com Page 2
Parameter report
Menu/Setup /Display /
Value 1 display Volume flow
0% bargraph value 1 0.0000 m³/min
100% bargraph value 1 1.2000 m³/min
Value 2 display None
Value 3 display None
www.endress.com Page 3
Parameter report
www.endress.com Page 4
Parameter report
Menu/Diagnostics /
Actual diagnostics C485 Measured variable simulation (Warning)0d00h03m00s Deactivate
simulation (Service ID 147)
Previous diagnostics Ok
www.endress.com Page 5
Parameter report
www.endress.com Page 6
Parameter report
Menu/Diagnostics /Simulation /
Assign simulation process variable Volume flow
Process variable value 0.0000 m³/min
Current output 1 simulation Off
Pulse output simulation 1 Off
Device alarm simulation Off
Diagnostic event simulation 65533
Diagnostic event category Process
www.endress.com Page 7
Parameter report
Menu/Expert/System/Administration/
Transmitter identifier 300
Activate SW option 36131071
Menu/Expert/Sensor/Process parameters/
Filter options Binomial
Flow damping 4
Median filter depth 1
Noise suppression Off
Response time 95 % 0.5 s
Flow override Off
Conductivity measurement Off
Conductivity damping 0.00 s
Conductivity temperature coefficient 2.10 %/K
Menu/Expert/Sensor/External compensation/
Density source Fixed density
Fixed density 1.0000 kg/l
www.endress.com Page 8
Parameter report
Menu/Expert/Sensor/Sensor adjustment/
Integration time 16.7 ms
Menu/Expert/Sensor/Calibration/
Nominal diameter DN100 / 4"
Calibration factor 0.8200
Zero point 0.0
Conductivity calibration factor 1.0000
Menu/Expert/Sensor/Calibration/Recalibration/
Calibration factor 1.0000
Menu/Expert/Sensor/Calibration/Logbook/
Calibration counter 0
Select calibration log entry 1
Timestamp --------
www.endress.com Page 9
Parameter report
Menu/Expert/Sensor/Testpoints/
Status 0x9
Flow velocity 0.0000 m/s
Raw volume flow 0.0000 m³/min
Filtered volume flow 0.0000 m³/min
Medium temperature -nan °C
Electronic temperature 30.0000 °C
Current difference potential 0.0000 V
Current potential electrode 1 0.0000 V
Current potential electrode 2 0.0000 V
Current potential electrode Pipe GND 0.0000 V
Impedance electrode EPD 0 Ohm
Impedance electrode E1 0 Ohm
Impedance electrode E2 0 Ohm
Current gain mode High
Current measuring period 50.00 ms
Current rise time 6.0850 ms
Current integration time 16.70 ms
Split time coil current 8.00 ms
Coil peak current 91.8850 mA
Current overvoltage 59.9987 V
Current hold voltage 7.7576 V
Coil impedance 85.9035 Ohm
Coil inductance 2.06 H
Power line current synchronisation Asynchronous
Ground connection switch Open
Assign test point 1 0
Test point 1 -nan
Assign test point 2 0
Test point 2 -nan
Assign test point 3 0
Menu/Expert/Sensor/Properties/
Nominal diameter 0.0500 m
Tube inner diameter 0.0500 m
Temperature sensor type No
EPD electrode existing Yes
www.endress.com Page 10
Parameter report
Menu/Expert/Communication/HART input/Input /
Value 0.0000
www.endress.com Page 11
Parameter report
Menu/Expert/Communication/Web server/
MAC address 00-07-05-10-00-00
DHCP client Off
IP address 192.168.1.212
Subnet mask 255.255.255.0
Default gateway 0.0.0.0
Web server functionality On
Menu/Expert/Communication/WLAN settings/
WLAN subnet mask 255.255.255.0
2.4 GHz WLAN channel 6
Menu/Expert/Communication/OPC-UA configuration/
Activate OPC-UA function No
Application URI urn:dev:mac:000705100000
www.endress.com Page 12
Parameter report
Menu/Expert/Communication/OPC-UA configuration/OPC-UA
settings/
Application name Promag
Port 4840
Minimum publishing interval 1000
Menu/Expert/Communication/OPC-UA configuration/OPC-UA
security/
Security policy None
Menu/Expert/Communication/Diagnostic configuration/
Event category 043 Out of specification (S)
Event category 376 Out of specification (S)
Event category 377 Out of specification (S)
Event category 441 Out of specification (S)
Event category 442 Out of specification (S)
Event category 443 Out of specification (S)
Event category 531 Out of specification (S)
Event category 832 Out of specification (S)
Event category 833 Out of specification (S)
Event category 834 Out of specification (S)
Event category 835 Out of specification (S)
Event category 861 Out of specification (S)
Event category 842 Out of specification (S)
Event category 962 Out of specification (S)
Event category 937 Out of specification (S)
Menu/Expert/Application/Inventory counter/
Totalizer value 0.0000 l
Totalizer overflow 0
www.endress.com Page 13
Parameter report
www.endress.com Page 14