Professional Documents
Culture Documents
BMU 40
| The Gold Standard | Cardiovascular | BMU 40 | 3 |
Maximum patient safety demands constant monitoring only shows all the relevant patient data clearly, but it also
of their vital blood parameters: The BMU 40 from MAQUET enables touchscreen access to the important settings –
Cardiovascular combines a high degree of measuring within seconds and with a single click.
precision with easy handling and clear organization and
thus helps the user to keep focused on the most important The MAQUET BMU 40 is the first blood analysis monitor to
thing – the patient. deliver precise and reliable data right from the start and can
be calibrated in less than five seconds.*
The latest sensor technology and a unique calibration system
using a ������������������������������������������������
2D-b��������������������������������������������
arcode reader set new standards for continu- MAQUET – The Gold Standard.
ous blood parameter analysis. The clear 10.4" display not
*
Data on file.
| 4 | BMU 40 | Cardiovascular |
EVERYTHING AT A GLANCE
EASY HANDLING OF THE BLOOD MONITORING UNIT BMU 40
*
Data on file.
p aO 2 in mmHg
600
400
∆pO 2= 502 mmHg
300 90 % of ∆pO 2= 451.8 mmHg
200
t 90 = 16.7 sec
100
67.2 mmHg = 90 % of change
17 mmHg = 0 %
0
0 10 20 30 40 50 60 70 80
Time in seconds
Both the arterial BMU Sensor and the venous BMU Cell
are directly integrated into the relevant line, so that
1,5 l/m, 37°C, 1/4"
p aO 2 in mmHg
500
Temperature on the venous and arterial side is measured 400 407 mmHg = 100 %
using noninvasive infrared thermopile sensors. The BMU 40
has no metal parts that come into contact with the blood, 300
∆pO 2= 390 mmHg
which in turn avoids unwanted hemolysis.
90 % of ∆pO 2= 351 mmHg
200
t 9 0 = 20.9 sec
Robust and easy-to-fit probes create a reliable connection
100
between the disposable and the BMU 40. Both the BMU
56 mmHg = 90 % of change
Cell and the BMU Sensor are available sterile-packed sepa- 17 mmHg = 0 %
0
rately or already connected in a tubing set. 0 10 20 30 40 50 60 70 80
Time in seconds
*
Data on file.
| Cardiovascular | BMU 40 | 7 |
PRECISION IN SIGHT
ACCURACY AND RESPONSE TIMES OF THE BMU 40
The benefits of BMU 40 sensor technology at a glance: Venous temperature < 28 seconds*
State-of-the-art accuracy
Oxygen partial pressure < 50 seconds
High stability – no drift
Quick response times Arterial temperature < 29 seconds**
t 90
0 10 20 30 40 50 60
1
Hematocrit is calculated three times the hemoglobin value
2
Source: Southworth R, Sutton R, Mize S, et al. Clinical evaluation of a new in-line continuous blood gas monitor. J Extra Corp Technol. 1998; 4: 166 –170.
Technical Data Blood Monitoring Unit BMU 40 Products and Accessories Code No.
Outside dimension (H x W x D) 220 x 380 x 170 mm incl. probe heads Blood Monitoring Unit BMU 40 70 104 08 52
Weight approx. 5 kg incl. arterial and venous probe
Power supply 100 – 240 V, 50/60 Hz (60 VA) and USB memory stick
Batter y runtime approx. 60 minutes Transport case for BMU 40 70 104 34 38
Display 10.4" TFT touchscreen Holder for BMU 40, 6 mm, 70 104 34 06
Resolution 800 x 600 Pixel incl. assembling plate and screws
Update frequency Arterial every three seconds, Holder for BMU 40, 100 mm 70 104 34 05
venous every six seconds incl. assembling plate and screws
Interfaces 2 x serial RS-232 port for data input Holder for BMU 40, 200 mm 70 104 34 04
and data output incl. assembling plate and screws
1 x USB port for data export on
USB flash disk Disposables Code No.
1 x USB port for printer connection BMU Cell 1/2" (10 pcs. per box) 70 104 08 04
BMU Cell 3/8" (5 pcs. per box) 70 104 08 44
Available sizes 3/8", 1/4" and 3/16" BMU Cell 1/4" (5 pcs. per box) 70 104 08 45
for BMU Sensors BMU Sensor 3/8" (10 pcs. per box) 70 104 08 49
Available sizes for BMU Cells 1/2", 3/8" and 1/4" BMU Sensor 1/4" (5 pcs. per box) 70 104 08 50
BMU Sensor 3/16" (5 pcs. per box) 70 104 08 51
® MAQUET Registered Trademark of MAQUET GmbH & Co. KG · Reg. QUG:MCV-BR-10000642-EN-02 · Copyright by MAQUET, Rastatt · 500 · 03/11 · We reserve the right to make technical and construction changes.
For local contact:
Please visit our website
www.maquet.com
MAQUET Cardiopulmonary AG
Hechinger Straße 38 GETINGE Group is a leading global provider of equipment and
systems that contribute to quality enhancement and cost efficiency
D-72145 Hirrlingen, Germany within healthcare and life sciences. Equipment, service and tech-
Phone: +49 (0) 7478 921-0 nologies are supplied under the brands ArjoHuntleigh for patient
Fax: +49 (0) 7478 921-100 handling and hygiene, disinfection, DVT prevention, medical beds,
therapeutic surfaces and diagnostics, GETINGE for infection control
info@maquet-cp.com and prevention within healthcare and life science and MAQUET for
www.maquet.com Surgical Workplaces, Cardiovascular and Critical Care.