Professional Documents
Culture Documents
for HCiX
HPS-PMC
(Process Measurement and Control)
CMM, JinSoo Seo Honeywell
1/105
Purpose for this training… Honeywell
2/93
Titles Honeywell
1. Features of HCiX
1-1. Product overview of HCiX
1-2. Communication ports
3/93
Product Overview(HCiX) Honeywell
15.0”,
High Resolution Display 1024 X 768
High Color Display (63336 colors, 16bit)
Custom Graphic Display
Ethernet Communication Support (TCP / UDP) as default 12.1”,
HWL and standard Modbus protocol 800 X 600
6/93
Screen Mode Honeywell
Screen Mode
- Run mode(Operating) : Running and operating (interfacing with PLC)
- Menu mode(Configuration) : default and basic for internal parameters
7/93
Screen Mode-Menu Honeywell
8/93
How to go to Menu from RUN mode Honeywell
After turning on HCiX, push this part continuously until the configuration page appears.
9/93
Installation of XDesignerPlus Honeywell
10/93
Running XDesignerPlus Honeywell
Running
- Double Click this icon of XDesignerPlus on desktop
- Run ‘XDesignerPlus’ from Programs
11/93
Running XDesignerPlus Honeywell
12/93
General Honeywell
File menus
Editing screen data
Edit option and tools
Transmitting(Download and Upload)
Menu-Draw with various shapes
Menu-View
Menu-Project
13/93
File Menu Honeywell
14/93
Creation of project Honeywell
Selecting a HCiX
- Series
- Model No and resolution,
Memory type
15/93
Creation of project Honeywell
16/93
Creation of project Honeywell
17/93
Creation of project Honeywell
Communication setup
for Serial comm
- Config for each com. port
- Notice :
whenever downloading, the set data
will be sent to HCiX
18/93
Creation of project Honeywell
19/93
Multi editing-Add a Project Honeywell
20/93
File-Save project Honeywell
21/93
Menu-View Honeywell
Show Name/ID
Project Manager
My Clipboard
List window
Property Window
Memory Manager
Screen
- Basic screen
- Window screen
- Sub screen
- Global Screen(Master/Frame)
Master screen : same as master slide(PPT)
Global Setting
- Data(Logging, Recipe, Alarm, Message, Images List)
- Script : For Global and Local region(similar to ‘C’)
- Text Table for multi-lingual
23/93
View-List Window Honeywell
24/93
Project Honeywell
- Change HCiX
- Change PLC
- CF/SD Card Setting
- PLC ADD(COM2, Ethernet)
- Fieldbus PLC ADD
- Config Comm parameter
- CF card setting
- Use Remote monitoring
26/93
Draw Honeywell
27/93
Draw-Select Honeywell
Select
- Shape to take a filling parameter
- Shape to take a non-filling parameter
28/93
Draw-Select Honeywell
Multiple shapes :
- (shift key) + Left button of mouse/Drag
Entire selection
- (ctrl key) + ‘A’
29/93
Draw-Property Honeywell
Preview
Security
Properties of object
Info.
30/93
Draw-Text(String) Honeywell
- Image Text
- Normal/Text Table
31/93
Draw-Image Honeywell
- Supported Images :
*.bmp, *.jpg, *.jpeg, *.mbs
32/93
Draw-Ruler Honeywell
33/93
EDIT Honeywell
34/93
EDIT-Move/Adjust Magnification/ Honeywell
Move
Using Mouse
- Select a shape/tag, click it on mouse pointer(+).
Using Keyboard
- Select a shape/tag, move it by using a arrow keys of keyboard.
- Space key
: Toggle, press one time, move it by grid value,
press one more time, move it by one pixel.
Magnification
Using Mouse / keyboard
35/93
Edit-options Honeywell
Repeat
- Repeat work on Editing project from last work
- Rows(Y) / Coulmns(X)
- Pixel interval of
Row/Column
- Address Increment
- Direction X, Y
37/93
Edit-others Honeywell
38/93
Edit-Group/Ungroup Honeywell
39/93
Edit-Assigning Honeywell
40/93
Transmitting(downloading project) Honeywell
Transmitting
41/93
Transmission-Transmitter Honeywell
Transmitter
- Execute Transmitter
- option : Ethernet/USB/Serial
- Download : PC HCiX
- Upload : HCiX PC
* Project file : *.zip
* all files are stored in PC with
specific folder
42/93
Transmission-Build Honeywell
Transmitter
- Build(Compiling)
- Option :
* Include project file in Build :
Transmitted with uploadable data
* Transmitter auto run
- Message : Result for compiling
* BUILD SUCCESS or BUILD FAILED
- Size : occupied size when compiled
Max : 26MB, but HCiX05=06MB
43/93
Transmitting-OS, Font(for V2.4) Honeywell
44/93
Add a basic screen in edit proejct Honeywell
Add screen
45/93
Screen Property Honeywell
46/93
Tags(Components) for communication Honeywell
Monitor of data from PLC, or Control to PLC Through communication with PLC.
47/93
Screen Change Honeywell
By ‘Touch tag’
48/93
Addressing_1 Honeywell
Addressing type
49/93
Addressing_2 Honeywell
50/93
Addressing_3 Honeywell
- Directly input
- Change and indicate the address
51/93
Tags Honeywell
52/93
Touch_1 Honeywell
Purpose
- Give a control action to PLC or monitor
any action.
Type
- Touch(only) : Giving any action only
- Touch+Lamp : multiple action
by any data from PLC.
Features
- 10 action are available on a Touch tag.
53/93
Touch_2 Honeywell
Display
-
InterLock-Locking condition
- activated by condition(bit/word)
Operation
- Bit state
- Word operation
- Key input: characters/numeric keys
- Special Function
Information
54/93
Touch_3 Honeywell
Touch + Lamp
: Touch operation + Indicator
(like Lamp) in on/off.
55/93
Lamp_1(Indicator) Honeywell
Purpose
: Monitors the monitoring address by on/off
from the PLC
Type
- Bit : monitor bit address
- Word : monitor bit address
- N-State : Monitor logical state
from multiple bit address
56/93
Lamp_2 Honeywell
57/93
Lamp_3 (N-State) Honeywell
Visual
: lamp type with var. condition
: 4-lamp, 8-lamp, 16-lamp
Lamp Address
: Bit addresses, 2/3/4
Information
: size and location
58/93
Numeric&String tag_1 Honeywell
Purpose
: Indicate any data from PLC, with word,
Integer/Float, and string data
Type
- Numeric : numbers, integer/float
- String : only ASCII code(Eng)
- Keydisplay : Numeric data+key input
- Keydisplay : String data+key input
59/93
Numeric&String tag_2 (Numeric/String) Honeywell
ITEM
Address
: for Data Processing from PLC
Case
: Color by data range
Disaply
: Font type or decimal type
Information
: size and location on screen
60/93
Numeric&String tag_3 (KeyDisplay) Honeywell
Purpose
: Indicate any data from PLC and sent the specific data into PLC.
Keypad
: can make a special key pad for user’s purpose
61/93
Numeric&String tag_4 (Keydisplay) Honeywell
Setup
Address
: Address for PLC or controller
Input Mode
- When Touch
- Popup ‘Auto Tenkey’
- Selected bit ON
- Use Arrow key
Disaplay
:
Information
:
62/93
Practice- Operation-running Honeywell
63/93
Practice- Assigning special keys Honeywell
Input character
- KeyDisplay for characters : Input
mode- when Touch
64/93
Message Tag_1 Honeywell
Purpose
: any message pre-reserved on [Message Table] is shown by any condition of
data from PLC.
Types
- Bit Message : Depends on bit data
- Word Message : Depends on Word data
65/93
Message Tag_2 (Creating Message Table) Honeywell
66/93
Message_3 (Bit Message) Honeywell
Message
- Set the message No to indicate
Address
- Address for bit data on PLC
Information
- Info for message tag,
- Size, position
67/93
Message_4 (Word Message) Honeywell
Message
- Data Range
- Data Mapping
- Data Indirect
Address
- Address for word data on PLC
Information
- Info for word message
68/93
Window Tag_1 Honeywell
Purpose
Pop up/down the window(s) by any condition and show the tags
Type
- Bit Window : Pop up a window by bit data of address
- Word Window : Call several windows by word data of address
Features
- can be Drawn several windows on main screen, but
the total windows at the same time, totally 8sets are able to show on screen
4 sets for ‘Pop-up’ and 4 sets for ‘Static’
69/93
Window Tag_2 (Bit Window) Honeywell
Window
- Input a condition of bit address
- Input a window to call
Information
- Position and size info on screen
70/93
Window tag_3 (Word window) Honeywell
Window
- Input a condition of word address
- set the range for word address
- Set the indirect address
Information
- Info about window
71/93
Practice- Window screen Honeywell
72/93
Alarm tag_1 Honeywell
Purpose
Alarm, when any activated data by target device is changed ON/OFF, a specific info is
stored in to HMI internally, and this tag makes a message is shown a table in screen.
Type
- Alarm : Shows an alarm on real time
- AlarmEx : shows an alarm on real time with several useful functions
73/93
Alarm tag_2 (Setting alarm list) Honeywell
74/93
Alarm tag_3 (Alarm) Honeywell
Alarm A type
- Current alarm
- Alarm History
- Alarm History(CF/SD)
- Other settings
Display
- Shape of alarm tag
Information
- Alarm tag info, size, positions
75/93
Alarm tag_4 – (AlarmEx) Honeywell
Display
- Table of shape
Alarm setting
- Data to show
- Useful keys
- New functions(handling,…)
Information
- Alarm tag info, size, position
76/93
Practice- Alarm screen Honeywell
Alarm History
- Alarm tag/ AlarmEx
77/93
Graph tag_1 Honeywell
Purpose
Show a data on graph tag, data type=Word.
Type
78/93
Graph tag_2 (Bar graph) Honeywell
Purpose
: Make the data(Word) over below type and show
79/93
Graph tag_3 (Bar graph) Honeywell
Graph
- Type of graph
- Address to indicate
- Max, Min
Display
- Color for each data
Information
- Tag information, size, position
80/93
Graph tag_4 (Linear graph) Honeywell
Purpose
- Show the data with linear(line) between data on real time.
- Show the several data in one graph
81/93
Graph tag_5 (Linear graph) Honeywell
Display
- Graph shape
Graph
- Setting address (Max 10)
Information
- Graph
82/93
Practice- Graph Honeywell
Bar graph
- bar graph
Linear graph
- Linear graph
83/93
Calculation tag Honeywell
Purpose
Make it to run a specific
function by any condition.
84/93
Communication tag Honeywell
85/93
Clock Honeywell
Purpose
: Display real time clock over
several format
86/93
Logging_1 (Logging setting) Honeywell
Function
: Save the actual data by any condition, into internal memory or external
memory like CF card or SD.
Config
: [Project]-[Logging setting] on Menu
- Log condition
- Log Action
87/93
Logging_2 (Alignment on external memory) Honeywell
Memory Alignment
88/93
Logging_3 (Log table) Honeywell
Function
: Show the logged data on table on real time.
89/93
Logging_4 (Graph Ex & Record) Honeywell
Function
: show the data on graph.
90/93
Security Honeywell
How to set
: [Project] [Security setting] on Menu
Purpose
- Set the password for each screen
- Set the security to access for all tags
- Settable security level to access
92/93
Security Setting-2 Honeywell
How to use
: Input PW data over window
Purpose
- Set the password for each screen
- Set the security to access for all tags
- Settable security level to access
93/93
Recipe_1 Honeywell
94/93
Recipe_2 (Setting) Honeywell
Config
: [Project]-[Recipe setting] on menu
- Condition of movement
: Variable, Bit
- Target address where recipe move
95/93
Grouping tags Honeywell
Function
: Make several shapes and Tags into a group
Config
: Select tags or shapes to make a group
press right button on mouse like picture
choose [Group]-[Group] or [UnGroup]
96/93
Animation-Rotating,Moving the object Honeywell
Function
: Make an object to ‘visible’ or ‘invisible’
: Set an object to ‘move’ or ‘rotate’
in screen
Config
: Select an object, press right-button
of mouse, select the special function
97/93
Animation-Rotating,Moving the object Honeywell
Function
: Make an object to ‘visible’ or ‘invisible’
: Set an object to ‘move’ or ‘rotate’ in screen
Config
: Select an object, press right-button of mouse, select the special function
98/93
Script (Programming) Honeywell
Function
: make a special program to activate(run) by unique action condition
Config
: [Project]-[Script] on Menu
Type
- Local script : run on specific screen
- Global script : run on all screens
99/93
Multi-lingual Honeywell
Function
: show any texts(message) to indicate on
screen to support on MS-Windows system
Config
- [Project]-[Text Table] on menu
- set a texts on each tag
- change the text over
Special buffer ‘_MULTI_LANG’
100/93
Simulator Honeywell
Function
: A function to check the project file easily without controller and HCi
Config
: [Tool]-[Run Simulator]
or press ‘F12’ key
101/93
Special-Slide tag Honeywell
Function
: show some images with particular
time-period, animation with images
Config
: [Tag]-[Slide]
102/93
Special-FileManager Honeywell
Function
: A function to move or copy the stored data
into external memory(CF)USB or USBCF
Config
: Add a ‘Window’
103/93
Tool-Password for security Honeywell
Function
: Able to assign an authority to access for each member(worker)
Config
- Add Default Password
- make sure the screen=65533
- editable
104/93
Tool-Remote view and control Honeywell
TopView Client
Function
: Able to do remote-view and remote-control
Config
- Select two options to use
105/93
Tool-Remote view and control Honeywell
TopView Client
Config
- Create Rview Client
- check the execution file on patch
106/93
XDesignerPlus training for HCiX Honeywell
Thanks.
107/93