FOUNDATIONS:

1. FOUNDATION DESIGN IS BASED ON THE INFORMATION PROVIDED ON THE STRUCTURAL


DRAWINGS FOR THE ORIGINAL STRUCTURE 10mm Ø STRAIGHT BARS
SPACE @ 120mm OC
REINFORCING STEEL:
A B C D
C A B C D
C A B C D
C

L/4

L/4
1. ALL REINFORCING STEEL SHALL BE SUPPORTED ON STANDARD ACCESSORIES, HELD RIGIDLY 10mm Ø CUT BARS
AND ACCURATELY IN PLACE, AND PROTECTED AGAINST DISPLACEMENT BEFORE AND SPACE @ 120mm OC
DURING PLACEMENT OF CONCRETE.
6.0
2. DOWELS AND OTHER MISCELLANEOUS STEEL EMBEDDED ITEMS SHALL BE LOCATED AND
HELD IN SPECIFIED POSITION PRIOR TO PLACEMENT OF CONCRETE AND SHALL NOT BE 2.0 1.5 2.5
3.0 3.0 3.0 3.0
PUSHED INTO CONCRETE FOLLOWING CONCRETE POUR.
1.0 1.0

CONCRETE MASONRY: SECTION 10mm Ø BEND BARS


1 C1
FTB
property line
FTB
C1
1
property line
1
property line

property line

property line

property line
SPACE @ 120mm OC
1. MASONRY WALLS SHALL BE BRACED EITHER BY OTHER INTERSECTING WALLS OR BY F1 F1
ANCHORAGE OR BRACING TO THE STRUCTURE ABOVE, OR TO ADJACENT WALLS, AS
DETAILED ON THE STRUCTURAL DRAWINGS. FTB
FTB

CONCRETE: 2 FTB
2 B1 B1 2 B3 B3
F1 FTB F1 C2 C2
C1 C1
ALL CONCRETE SHALL BE DESIGNED TO MEET THE FOLLOWING CRITERIA FOR USE IN VARIOUS 1.3
ELEMENTS OF THE
28-DAY COMPRESSIVE STRENGTH MAX. SIZE AGGREGATE
6

FTB

FTB

FTB
A. FOOTINGS (WALL & MAT) 3000 3/4" B1 3.4 B3 3.4
B. FOUNDATION WALLS 3000 3/4" S-1 SLAB SECTION DETAIL 4.1
B2 B1
4.1
B3 B3

C. SLAB-ON-GRADE 3000 3/4"


D. ELEVATED FLOORS & BEAMS 4000 3/4"
3.7
SLABS ON GRADE: UNLESS NOTED OTHERWISE, CONCRETE SLABS ON GRADE SHALL BE A 3 3 B2
3 B3
F1 FTB F1 FTB F1 B2 B3
C2 C3 C2
MINIMUM OF 4" THICK, REINFORCED SPECIFIED ON DRAWING. SLABS SHALL BE PLACED OVER C1 C3 C1
12.0
PROPERLY COMPACTED EARTH.

LENGHT
1.6 1.6

FTB

FTB

FTB
3.2 B2 B3
1.9 B1 1.9 B3

L/4

L/4
B1 B3
BEAM SCHEDULE F1 F1 1.0
TERRACE
0.9 0.9

FTB FTB C2 B1 C2 B1 C2 B3 B3
20mm Ø STRAIGHT BARS 3 3 3
TYPE C1 C1
DESCRIPTION
SUPPORT MID. SPAN
REINFORCEMENT SPACE @ 120mm OC

FTB(Existing) 3- 12mm TOP BARS 20mm Ø CUT BARS

property line
SPACE @ 120mm OC

property line

property line
3- 12mm BOTTOM BARS

property line

property line

property line
( 200 X 300mm )
10mm Ø STIRRUPS SPACED @ 5- 50mm
5- 100mm & THE REST @ 200mm CAR PARK
20mm Ø BEND BARS
SPACE @ 120mm OC
B1(Existing) 3- 12mm TOP BARS
3- 12mm BOTTOM BARS
( 200 X 300mm )
10mm Ø STIRRUPS SPACED @ 5- 50mm
5- 100mm & THE REST @ 200mm

property line property line property line


B2 3- 16mm TOP BARS
3- 16mm BOTTOM BARS
( 200 X 300mm )
10mm Ø STIRRUPS SPACED @ 5- 50mm
5- 100mm & THE REST @ 200mm

B3 3- 12mm TOP BARS


4 1 2 3
( 200 X 300mm )
3- 12mm BOTTOM BARS
S-1 CONCRETE SLAB DETAIL S1 S-1 EXISTING GROUND FLOOR S-1 SECOND FLOOR S-1 ROOF FRAMING
10mm Ø STIRRUPS SPACED @ 5- 50mm
5- 100mm & THE REST @ 200mm

LENGHT
COLUMN SCHEDULE
L/4

L/4

DESCRIPTION TYPE REINFORCEMENT


20mm Ø STRAIGHT BARS
SPACE @ 120mm OC
6- 12mm

400.0
C1(Existing) 10mm Ø Lateral ties spaced @ 5 @50mm
6 PCS. - 12mmØ main bars
5 @100mm
10mm Ø STIRRUPS SPACED @ 5- 50mm
L/4

400.0
5 @150mm
( 200 X 300mm )
5- 100mm 5- 150mm & THE REST 20mm Ø BEND BARS & the rest @ 200mm

@ 200mm 10mm Ø VERT. BARS @ 600mm O.C WITH


SPACE @ 120mm OC A B C D
C 10mm Ø HORIZONTAL BARS IN EVERY
THREE LAYER OF CHB

3.0 3.0 A B C D
C 100mm THK. CHB.
GROUND FLOOR LINE
C2 6- 12mm
10mm Ø STIRRUPS SPACED @ 5- 50mm 20mm Ø CUT BARS property line

450.0
( 200 X 300mm ) 1 RIB-TYPE PRE-PAINTED GI SHEET 6 PCS. - 12mmØ main bars NGL

5- 100mm 5- 150mm & THE REST SPACE @ 120mm OC 10mm Ø Lateral ties spaced @ 5 @50mm

property line
WALLCAPPING 5 @100mm
@ 200mm 1 21 x 1 12 Angle 1

650.0
Bar 5 @150mm
WALL 2 - 10mm Ø REINFORCED BARS

WALL CAPPING
& the rest @ 200mm GROUND FLOOR LINE

200.0
75mm C-PURLINS

100.0
SPACED @80mm

450.0
Gutter
NGL
10mm Ø TIES SPACE @ 200mm OC
C3 8- 12mm
10mm Ø STIRRUPS SPACED @ 5- 50mm 2
( 200 X 300mm ) Gutter Gutter
5- 100mm 5- 150mm & THE REST
@ 200mm 2 TIE BEAM
SECTION SHOWING

2300.0
FOOTING

2500.0
L/4

400.0
200.0
1 21 x 1 12 Angle

WALL CAPPING
Bar

WALL CAPPING
6.9 10mm Ø VERT. BARS @ 600mm O.C WITH

3 SECTION 10mm Ø HORIZONTAL BARS IN EVERY


THREE LAYER OF CHB

100mm THK. CHB.


3
GROUND FLOOR LINE

450.0
2000.0
NGL

300.00
6- 16mmØ def. bed bars

600.0
spaced as shown bothways

400.0
300.0 300.0 300.0 300.0 300.0 300.0 300.0 300.0 300.0 300.0 3
3

800.0
180.0
5 WALL FLASHING
SECTION SHOWING
180.0

S-1 CONCRETE SLAB DETAIL S1 SPANISH FLASHING


WALL CAPPING
TIE BEAM
180.0

2000.0

400.0
180.0
180.00

75mm C-PURLINS

property line
180.0

property line
SPACED @80mm
L/4

property line

800.0
property line
180.00

7
LENGTH

S-1 WALL FOOTING DETAIL


1200.0

PLAN
L/4

300.00 300.00

C1 - F1
property line

property line
7
S-1 STAIR DETAIL 0.8 8
COLUMN FOOTING DETAIL
9 S-1
10mmØ BEND & CUT REINF. 0.8 ROOF FRAMING PLAN
1 21 x 1 21 Angle Bar S-1 10
SPACED @ 150mm OC
S-1 ROOFING PLAN
10mmØ TOP DIAG. BARS
1 21 x 1 21 Angle Bar
180.00

SPACED @ 150mm OC

10mmØ BEND DIAG. BARS 6.5 3.0


SPACED @ 150mm OC
10mmØ BOTTOM/TOP BARS

10mmØ BEND & CUT REINF.


150.00
SPACED @ 150mm OC

10mmØ BOTTOM DIAG. BARS


11
SPACED @ 150mm OC
S-1 TRUSS DETAIL

ENGINEER ENGINEER ENGINEER PROJECT TITLE: PROJECT OWNER: SHEET CONTENTS: DESIGNED BY: SHEET NO:

DRAWN BY:
STRUCTURAL FLOOR PLAN
PROPOSED 2-STOREY HOUSE

PRC NO. DATE PRC NO. DATE PRC NO. DATE


IMPROVEMENT
PH:2 BLK:1 LOT:11 SAN ANTONIO SOUTH
BRGY. LANGKIWA, BINAN, LAGUNA
VERNADETTE N. CABRILLAS
SAN VICENTE, BINAN, LAGUNA
SCHEDULE OF BEAMS
AND COLUMNS
CHECKED BY:

APPROVED BY:
S-1
FOOTING DETAIL
REVISION BY:
RTR NO. DATE RTR NO. DATE RTR NO. DATE
T.I.N. PLACE T.I.N. PLACE T.I.N. PLACE STAIR DETAIL DATE REVISED: PROJECT NO: