You are on page 1of 16

TSC1 Asset Surveyor

™ ®

Release Notes

■ Introduction

■ New Features

■ Installing Asset Surveyor

Version 5.27


Revision A
October 2002
Corporate Office THE WARRANTIES ABOVE STATE TRIMBLE'S ENTIRE
Trimble Navigation Limited LIABILITY, AND YOUR EXCLUSIVE REMEDIES, RELATING TO
Mapping and GIS Division PERFORMANCE OF THE PRODUCTS AND SOFTWARE.
645 North Mary Avenue EXCEPT AS OTHERWISE EXPRESSLY PROVIDED HEREIN,
Post Office Box 3642 THE PRODUCTS, SOFTWARE, AND ACCOMPANYING
Sunnyvale, CA 94085 DOCUMENTATION AND MATERIALS ARE PROVIDED “AS-IS”
U.S.A. AND WITHOUT EXPRESS OR IMPLIED WARRANTY OF ANY
Phone: +1-408-481-8940, 1-800-545-7762 KIND BY EITHER TRIMBLE NAVIGATION LIMITED OR
Fax: +1-408-481-7744 ANYONE WHO HAS BEEN INVOLVED IN ITS CREATION,
www.trimble.com PRODUCTION, INSTALLATION, OR DISTRIBUTION,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
Copyright and Trademarks WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
© 1999–2002, Trimble Navigation Limited. All rights reserved. PARTICULAR PURPOSE, TITLE, AND NONINFRINGEMENT.
The Globe & Triangle logo, TSM, Trimble Survey Controller, THE STATED EXPRESS WARRANTIES ARE IN LIEU OF ALL
and TSC1 are trademarks of Trimble Navigation Limited. OBLIGATIONS OR LIABILITIES ON THE PART OF TRIMBLE
Trimble, the Sextant logo with Trimble, Asset Surveyor, and ARISING OUT OF, OR IN CONNECTION WITH, ANY
GPS Pathfinder are trademarks of Trimble Navigation Limited, PRODUCTS OR SOFTWARE. SOME STATES AND
registered in the United States Patent and Trademark Office. All JURISDICTIONS DO NOT ALLOW LIMITATIONS ON
other trademarks are the property of their respective owners. DURATION OR THE EXCLUSION OF AN IMPLIED WARRANTY,
Release Notice SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This is the October 2002 release (Revision A) of the TSC1 Asset TRIMBLE NAVIGATION LIMITED IS NOT RESPONSIBLE FOR
Surveyor Release Notes. It applies to version 5.27 of the Asset THE OPERATION OR FAILURE OF OPERATION OF GPS
Surveyor® software. SATELLITES OR THE AVAILABILITY OF GPS SATELLITE
SIGNALS.
The following limited warranties give you specific legal rights. Limitation of Liability
You may have others, which vary from state/jurisdiction to TRIMBLE’S ENTIRE LIABILITY UNDER ANY PROVISION
state/jurisdiction. HEREIN SHALL BE LIMITED TO THE GREATER OF THE
Software and Firmware License, Limited AMOUNT PAID BY YOU FOR THE PRODUCT OR SOFTWARE
LICENSE OR U.S.$25.00. TO THE MAXIMUM EXTENT
Warranty PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL
This Trimble software and/or firmware product (the “Software”) TRIMBLE OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT,
is licensed and not sold. Its use is governed by the provisions of SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
the applicable End User License Agreement (“EULA”), if any, WHATSOEVER UNDER ANY CIRCUMSTANCE OR LEGAL
included with the Software. In the absence of a separate EULA THEORY RELATING IN ANY WAY TO THE PRODUCTS,
included with the Software providing different limited warranty SOFTWARE, AND ACCOMPANYING DOCUMENTATION AND
terms, exclusions, and limitations, the following terms and MATERIALS, (INCLUDING, WITHOUT LIMITATION,
conditions shall apply. Trimble warrants that this Trimble DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS
Software product will substantially conform to Trimble’s INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR ANY
applicable published specifications for the Software for a period OTHER PECUNIARY LOSS), REGARDLESS OF WHETHER
of ninety (90) days, starting from the date of delivery. TRIMBLE HAS BEEN ADVISED OF THE POSSIBILITY OF ANY
Warranty Remedies SUCH LOSS AND REGARDLESS OF THE COURSE OF DEALING
Trimble's sole liability and your exclusive remedy under the WHICH DEVELOPS OR HAS DEVELOPED BETWEEN YOU AND
warranties set forth above shall be, at Trimble’s option, to repair TRIMBLE. BECAUSE SOME STATES AND JURISDICTIONS DO
or replace any Product or Software that fails to conform to such NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY
warranty (“Nonconforming Product”), or refund the purchase FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE
price paid by you for any such Nonconforming Product, upon ABOVE LIMITATION MAY NOT APPLY TO YOU.
your return of any Nonconforming Product to Trimble in
accordance with Trimble’s standard return material authorization
procedures.
Warranty Exclusions and Disclaimer
These warranties shall be applied only in the event and to the
extent that: (i) the Products and Software are properly and
correctly installed, configured, interfaced, maintained, stored,
and operated in accordance with Trimble’s relevant operator's
manual and specifications, and; (ii) the Products and Software
are not modified or misused. The preceding warranties shall not
apply to, and Trimble shall not be responsible for defects or
performance problems resulting from (i) the combination or
utilization of the Product or Software with products,
information, data, systems or devices not made, supplied or
specified by Trimble; (ii) the operation of the Product or
Software under any specification other than, or in addition to,
Trimble's standard specifications for its products; (iii) the
unauthorized modification or use of the Product or Software; (iv)
damage caused by accident, lightning or other electrical
discharge, fresh or salt water immersion or spray; or (v) normal
wear and tear on consumable parts (e.g., batteries).
0.1Introduction
Welcome to version 5.27 of the Asset Surveyor® software
(Asset Surveyor 5.27). This software runs on Trimble’s TSC1™ data
collector (the TSC1).
For a tutorial on using Asset Surveyor to collect and maintain data,
refer to Chapter 5 of the TSC1 Asset Surveyor Operation Manual. For
more detailed information on the software, refer to the relevant
sections of the TSC1 Asset Surveyor Software User Guide.

0.2New Features
Asset Surveyor version 5.27 includes fixes for the following problems:
• If you delete a line or area feature that contains averaged
vertices from the Review list, and then display the Map screen,
error message Mapfeat 3225 appears.
• When you press the I softkey, and the selected line or area
feature has both averaged vertices and an offset applied, error
message Delta 6061 appears.
• Asset Surveyor is unable to track the LandStar L-band satellite
in Europe. Due to a catastrophic failure of the EMS
communication satellite, LandStar services to Europe on
1531.210 MHz have ceased. In September, a new European
beam began operating on 1535.195 MHz. The version 5.27
software includes this new frequency for LandStar users in
Europe.

TSC1 Asset Surveyor Release Notes 3


0.3Installing Asset Surveyor
If you want to install Asset Surveyor 5.27 on an existing TSC1 data
collector (with an earlier version of Asset Surveyor or the Trimble
Survey Controller™ software already installed), then read this section
carefully and follow the instructions it contains.

0.3.1 Equipment Required for Installation


To install Asset Surveyor 5.27 on the TSC1 data collector, you need
the following:
• An IBM-compatible personal computer running Windows 95,
98, Me, XP, or NT, with at least one available serial RS232 port
and at least 8 MB of free hard disk space.
• Your TSC1 data collector.
• The Asset Surveyor 5.27 software. This includes the
WinFLASH software. Download Asset Surveyor 5.27 from the
Trimble website at www.trimble.com/assetsurveyor.html.
• Optionally, a 9-pin to 25-pin converter. This is required if your
personal computer has a 25-pin serial port connector on its
COM1 or COM2 port.
• Optionally, a Trimble Support Module (TSM™). A TSM
provides an external source of power for installation, so that you
do not have to use the TSC1 data collector’s internal battery.
Connect the TSM to the TSC1, using the appropriate adapter
cable for the model of TSM.
Note – You can install Asset Surveyor using power from the
TSC1 internal lithium-ion battery; however, Trimble
recommends that you use a TSM. This prevents accidental
termination of the installation process while running off a
discharged battery.

4 TSC1 Asset Surveyor Release Notes


0.3.2 Installing Asset Surveyor 5.27 on a TSC1
Before installing Asset Surveyor 5.27, perform an option upgrade if:
• the TSC1 is currently running the Trimble Survey Controller
software and does not have a valid license for Asset Surveyor
• the current Asset Surveyor support warranty has expired.
For instructions on how to perform an option upgrade, see Loading
Options on the TSC1, page 14. After upgrading you can install Asset
Surveyor.

C Warning – When Asset Surveyor is installed on the TSC1, it erases the


data collector’s memory. The installation does not begin until you transfer
and delete all data files from the TSC1.

TSC1 Asset Surveyor Release Notes 5


Using a TSM as the power source
To install Asset Surveyor on your TSC1 data collector, using a TSM as
an external power source, connect the equipment listed on page 4. See
Figure 1.

1
3

1 TSM extension cable (P/N 14284)


2 Null modem cable (P/N 18532)
3 TSC1 data cable (P/N 32287-00)

Figure 1 Connecting to a PC – TSM power supply

6 TSC1 Asset Surveyor Release Notes


To connect the TSC1 data collector to your personal computer:
1. Plug the TSM into the wall current (mains).
2. Connect one end of the TSM extension cable (P/N 14284) to the
DATALOGGER port on the TSM.
3. Connect the other end of the TSM extension cable to the TSC1
data cable (P/N 32287-00). This cable connects to either the top
or bottom port of the TSC1.
4. Connect the COMPUTER port on the TSM to the personal
computer’s COM1 or COM2 serial port, using the null modem
cable (P/N 18532).
5. Make sure the TSC1, TSM, and personal computer are turned
on.
Using the TSC1 lithium-ion battery as the power source
To install Asset Surveyor on your TSC1 data collector, using the TSC1
internal lithium-ion battery as the power source, connect the
equipment listed on page 4. See Figure 2.

2
1 TSC1 data cable (P/N 32287-00)
2 Null modem cable (P/N 18532)

Figure 2 Connecting directly to a PC – TSC1 internal battery

TSC1 Asset Surveyor Release Notes 7


Note – You cannot install Asset Surveyor using the TSC1 internal
lithium-ion battery if the battery level is below 50%.
To connect the TSC1 data collector directly to your personal
computer:
1. Connect the TSC1 data cable (P/N 32287-00) to the top or
bottom port on the TSC1.
2. Connect the other end of the TSC1 data cable to the null modem
cable (P/N 18532).
3. Connect the other end of the null modem cable to the personal
computer’s COM1 or COM2 serial port.
4. Make sure the TSC1 and personal computer are turned on.
Note – You can install Asset Surveyor using power from the TSC1
internal lithium-ion battery; however, Trimble recommends that you
use a TSM. This prevents accidental termination of the installation
process while running off a discharged battery.

Installing Asset Surveyor


To install Asset Surveyor:
1. Turn on your personal computer.
2. Download the Asset Surveyor 5.27 software from the Trimble
website at www.trimble.com/assetsurveyor.html.
3. Double-click the downloaded file to begin installing the
WinFLASH software, and follow the instructions on the screen.

8 TSC1 Asset Surveyor Release Notes


4. To start WinFLASH, select Start / Programs / WinFLASH /
WinFLASH. The Device Configuration dialog appears:

5. Select TSC1 Data Collector as the device type and specify the
serial port on your PC that your TSC1 is connected to.

TSC1 Asset Surveyor Release Notes 9


6. Click Next. The Operation Selection dialog appears:

10 TSC1 Asset Surveyor Release Notes


7. Select the Software upgrade option and click Next. A TSC1
Software Selection dialog similar to the following appears:

TSC1 Asset Surveyor Release Notes 11


8. Select Asset Surveyor v5.27 as the software version you want to
install on your TSC1 and click Next. A Settings Review dialog
similar to the following appears:

9. Review the current settings and click Finish.


The program initiates communication with the TSC1, and an
installation progress dialog appears:

12 TSC1 Asset Surveyor Release Notes


Note – You cannot install Asset Surveyor if the TSC1 is in File
Transfer mode, a GPS receiver is connected to the TSC1, the
TSC1 contains data files, or you are installing using the TSC1
internal lithium-ion battery when the battery level is below
50%.
The installation takes about five minutes. Typically, Asset
Surveyor transfers to the TSC1 automatically.
When the installation is complete, the following dialog appears
on your personal computer:

10. Click Exit to close WinFLASH.


11. Your TSC1 now performs a cold boot and automatically starts
the newly installed software.
The Trimble logo screen appears just after rebooting. It
identifies the new Asset Surveyor software and shows the
version number, that is, 5.27.
12. If you have just installed Asset Surveyor 5.27 on your TSC1,
reload the data dictionaries, coordinate system sites, and
waypoint files that were erased during installation by
transferring these files from your desktop computer.

TSC1 Asset Surveyor Release Notes 13


0.3.3 Loading Options on the TSC1
Before installing Asset Surveyor, perform an option upgrade on your
TSC1 data collector if:
• the TSC1 is currently running the Trimble Survey Controller
software and does not have a valid license for Asset Surveyor
• the current Asset Surveyor support warranty has expired
The following instructions show how to upgrade the software option
on a TSC1. To upgrade the option you must have a Trimble-provided
password.
Note – Once the option is successfully upgraded, you must install
Asset Surveyor 5.27. For more information, see Installing Asset
Surveyor 5.27 on a TSC1, page 5.
For the option installation using a TSM as an external source of power,
connect the equipment listed on page 4. See Figure 1 on page 6.
For the option installation using the TSC1 internal lithium-ion battery
as the power source, connect the equipment listed on page 4. See
Figure 2 on page 7.
Note – You cannot install Asset Surveyor using the TSC1 internal
lithium-ion battery if the battery level is below 50%.
Note – You can install the TSC1 option using power from the TSC1
internal lithium-ion battery; however, Trimble recommends that you
use a TSM. This prevents the installation from terminating while
running off a discharged battery.
You can now proceed with the option installation:
1. Turn on your personal computer.
2. Download the Asset Surveyor 5.27 software from the Trimble
website at www.trimble.com/assetsurveyor.html.
3. Double-click the downloaded file to begin installing the
WinFLASH software, and follow the instructions on the screen.

14 TSC1 Asset Surveyor Release Notes


4. To start WinFLASH, select Start / Programs / WinFLASH /
WinFLASH. A dialog similar to the following appears:

5. Select TSC1 Data Collector as the device type and specify the
serial port on your PC that your TSC1 is connected to.

TSC1 Asset Surveyor Release Notes 15


6. Click Next. The Operation Selection dialog appears:

7. Select Option upgrade and click Next.


8. WinFLASH prompts you to enter your option password. Enter
the Trimble password exactly, matching the case, and click
Next.
The program initiates communication with the TSC1 and the
option installation completes automatically.

16 TSC1 Asset Surveyor Release Notes