GENERAL
In general, SS GRACE DAHLIA is built by NYK to cater its spot charter cargo. Depends on the charterer
requirement, it can use 100% gas burning, HFO only, LSHFO only, MGO only or dual fire with any
combination of the fuel with gas fire .
The Main Engine is of single screw propulsion and located in the aft part of the ship. It has additional
Intermediate Pressure turbine which is connected to the HP turbine. The maximum rpm on this engine is
76rpm @ 20.5 knot.
At SECA area, the ship will mostly used 100% gas burning while on passage. During maneuvering, dual
fire will be use, either with MGO or LSHFO, depends on charterer. Normally in port, they will use 100%
gas burning. All this will depends on the charterer instructions.
One geared steam turbine fitted as the main turbine and one fixed pitch propeller.
Two main boilers fitted, the heat cycle of the propulsion machinery plant shall be the reheat,
regenerative and gas air heater cycle. The exhaust steam from high pressure turbine of the main turbine
shall be led to main boiler “Reheater” and shall be reheated when steaming above 55rpm.
The boilers produce 120 bar of steam pressure, this 120bar steam goes to the HP turbines and the
exhaust of HP turbine is diverted to boilers “Reheater” before it goes back to IP turbine and eventually
to main condenser. The “Reheater” can only be in use when steaming above 55rpm, at below 55rpm the
exhaust steam is passing the “Reheater” without doing any work. At above 55rpm the “Reheater”
damper can be open to allow flue gas to reheat the exhaust steam from HP turbine in the boilers and
then it will drive IP turbine to increase efficiency. At 72 rpm, the exhaust steam at IP turbine inlet is
approximately 24bar, 540deg C. An increase of about 200degC can be achieved when the “Reheater” is
in used.
The condensate from the main condenser and feed water will be heated through one distilling plant,
one gland condenser, two low pressure feed water heaters, one dearating feed water heater and two
high pressure feed water heaters.
Bleeding of the main turbine is made at five points: H.P, I.P, Crossover and L.P (two points)
The ship is provided with two steam turbine driven electric generators, two diesel engine driven electric
generators and one emergency diesel engine driven electric generator. The power distribution is 6.6kv,
440v and 100v.
The exhaust steam from the generator turbine is led to the main condenser and for emergency used to
the auxiliary condenser.
HFO : 4230Mt
LSHFO : 637Mt
MGO : 160Mt
MDO : 215Mt
If it is required to burn the boil off gas at main turbine stop or low load condition, excess steam shall be
led to main condenser or auxiliary condenser in an emergency.
Scoop system is provided for cooling the main condenser on normal sea going condition.
One low pressure steam generator is provided for oil heating and miscellaneous service system.
Central fresh water cooling system is provided for auxiliary machinery in engine room and cargo
machinery.
The main turbine, propulsive shafting and propeller is designed and sized for MCR power at revolution
between 92% and 103% of those predicted for the clean hull MCR trial.
Domestic Fresh water tank capacity is 550m3 and Distil tank capacity is 420m3, average daily usage for
Domestic FW is 15m3 and Distill is 18m3(HFO in used) / 10m3(Gas only)
Fixed Fire fighting system for the whole of ER is High Expansion Foam. CO2 covers the Main and Cargo
switchboard room, EDG room, Paint Store, Cargo Machinery room and Motor room. Dry Powder is used
on various location on deck.
The main propulsion unit is a cross compound turbines with double reduction gear. The unit consists of
one High Pressure turbine combined with Intermediate Pressure turbine, one Low Pressure turbine
including astern elements, maneuvering valve unit and reduction gear.
The ahead steam from the maneuvering valve is admitted to the High Pressure turbine through nozzles
which are arranged in three groups and fitted with one manual nozzle valve and one operated nozzle
valve. Steam is con controlled by the maneuvering valve unit only.
The astern turbine is capable of operating astern at 70% of the maximum ahead rpm for period of not
exceeding one hour without overheating.
Connections are provided to permit independent operation of either High Pressure turbine and
Intermediate pressure turbine or the Low Pressure turbine for an emergency purpose. This is accomplish
by an emergency steam supply from the desuperheated steam line to the Low Pressure turbine or an
emergency exhaust connection from the cross over pipes to the Low Pressure turbine exhaust casing.
The turbine gland is of steam sealed, spring backed labyrinth type.
The motor driven turning gear is fitted on the reduction gear casing.
The turbine is fitted with “Warming up System” which can warm up the turbine up to the required
temperature.
MAIN TURBINE
3) Maneuvering Valve
The maneuvering valve consists of the Ahead Throttle valve, Astern Throttle valve and Operating
Hydraulic cylinder. The Throttles valve is actuated by the Hydraulic cylinder. The Mechanical
gears is arranged for an emergency operation of throttle valve on failure of the hydraulic system
The reduction gear is Tandem Articulated Type. Each turbine is connected by a flexible coupling to the 1 st
reduction pinion of reduction gears.
The aft end of HP 1st reduction pinion shaft has extensions for motor driven turning gear.
Main thrust bearing of Tilting Pad type and fitted in separate casing located aft of the main reduction
gear. This bearing is supplied with ol from the main lubricating system.
MAIN CONDENSER
The Main Condenser I of straight tube, reheating, surface cooling type arranged for single pass of
circulating water and provided with an air cooling section and condenser hot well.
The inside surface of water covers is lined with neoprene of approx. 3mm thickness.
A connection of the shell through which high velocity steam or drain may enter is provided with baffles
to protect the tubes from impingement damage.
Generator turbine exhaust steam line and steam Dump line is connected to the main condenser.
Iron plate anodes are provided in the water boxes for corrosion protection of the condenser tubes.
The main condenser is served by the vacuum pumps which is Horizontal water ring type.
MAIN ENGINE
STEAM GENERATING PLANT
The main Boiler is of two –drum complete membrane water tube wall, single casing, marine reheat
boiler. The boiler is consist of roof firing wholly water walled furnace, screen tubes, horizontal
convection superheaters and reheaters, extended surface integral economizers and shall be arranged
for burning fuel oil and fuel gas under forced draught.
MAIN BOILER
DRUM
The steam and water drum is of boiler steel plate fusion welded construction. The steam drum is fitted
with steam separator baffles, swash plate, feed water distribution pipe, superheater steam temperature
control desuperheater (attemperator), surface blow-off pipe, chemical feed pipe, dumping chamber for
feed water regulator and sampling pipe.The water drum is fitted with auxillary desuperheater and
bottom blow off pipe.
BOILER TUBES
1) Membrane Walls
Furnace water wall, exhaust gas path water wall, division water wall and center water wall.
Membrane tube walls is provided for the side wall, front wall, rear wall, roof and bottom of
furnace, and also side wall , front wall, rear wall and bottom wall of exhaust gas path.
Membrane tube division wall is fitted between furnace and exhaust gas path.
Membrane tube center wall is provided between superheater path and reheater path in the gas
path.
2) Screen Tubes
Lower parts of division water wall do not have fins between the tubes and this will allow the
exhaust gas to come into superheater gas path and reheater gas path.
5) Economizer
The intergral economizer is arranged in exhaust gas path above the superheater and reheater.
The tube elements consist of seamless carbon steel tubes fitted with steel fins, and welded to
the feed water inlet header and outlet header. The outlet header is led to the steam drum with
an external pipe.
REHEATER DAMPER
Each Boiler is fitted with an exhaust gas damper for the reheated steam temperature control and
reheater protection. The system is consist of a control Damper, a protection damper and a seal air
damper, and the damper is installed between the economizer and gas air heater.
The control damper shall regulate the exhaust gas quantity passing through the reheater gas path for
controlling the reheated steam temperature un the reheat condition.
The reheat condition is only applicable for Main Engine speed above 55RPM. It requires 40 minute for
warming up, meaning the speed need to be stagnant at 55RPM until it is properly warm up to further
increase the speed . Same apply to slowing down, it requires the speed to stagnant at 55RPM, to cool
down before the speed can reduce further.
Under the non reheat condition, the control Damper and the protection damper is closed and seal air is
supplied to the space between these two dampers through the seal air damper to prevent overheating
or reheater tubes caused by the exhaust gas flow.
GAS AIR HEATER
A Gas Air Heater of vertical, continuous counter flow type is provided for both boilers.
The materials of cold layer heating element is consist of enamelled steel and the material of hot layer
heating elements shall be of corrosion resistant alloy. The gas air heater is assembled with casing, rotor
driving gear, an electric motor, an emergency air motor, integral air by-pass, heat transfer elements and
sootblower for gas side. The air side by-pass damper is remotely and automatically operated.
Sootblowing operations is recommended to be carry out every 50ton of HFO used, this is to prevent the
Gas Air Heater from clogging.
BOILER FITTINGS
1) Safety valves
Two steam drum safety valves and one superheater outlet safety valves and one Reheater outlet
safety valves, on each boiler.
In addition, a solenoid operated pressure relief valve is fitted at superheater outlet of each
boiler.
2) Burner
Each boiler is fitted with burners with air registers. Each burner consist of steam atomizing type
fuel oil burner and a multi-nozzle type boil-off gas burner. The burner is of Double Swirler type
3) Sootblower
The sootblower is of electric driven, steam jet type. Horizontal, long retractable ype sootblower
is provided for superheaters and reheaters. Stationeryand rotary type sootblowers is provided
for economizer.
The sootblower is a Valve-in Head type and is operated with the supply of desuperheated
steam.
4) Water Level Gauge
Two sets of transparent type(multi-port type) water level gauge is fitted at the fore end of the
steam drum for each boiler.
7) Combustion Control
The combustion control system shall regulate the fuel and air ratio to the boiler, in accordance
with the steam demand, by maintaining the steam pressure at the superheater outlet of the
boiler within predetermined limits.
The fuel oil and gas flow quantity is controlled by diaphragm valves in fuel lines.
The fans take suction from upper part of engine room and discharge to main boiler air casing through
the gas air heater .Dampers and ducts can be arranged so that one of three fans can be used as a
common standby for two working fans.
The low pressure steam generator is provided with a thermometer and a pressure gauge on heating
steam (tube) side, a pressure gauge , a safety valve, an air vent and a drain valve on generating
steam(shell) side, and a drain tank with drain level control device.
The drain cooler is provided with a thermometer on the inlet and outlet of the steam drain (tube) and
feed water (shell), an air vent valve and a drain valve.
GENERATOR TURBINE
The Generator turbine is a single cylinder, multi-stage impulse, condensing type with reduction gear.
The reduction gear is of the single helical single reduction type. The turbine rotor and reduction rear
shaft is coupled with flange and shall be supported by three bearings.The turbine reduction gear and
generator is mounted on the common bed structure in which a luboil sump tank is incorporated.
The turbine is equipped with a governor which regulates the governing valve. The governor shall control
the turbine speed within the range of 10% of the rated speed for momentary variation and 5% for
permanent variation.
The turbine packing steam pressure is controlled automatically by the air operated packing steam
control valve. Gland leak –off steam shall be led to the gland steam condenser.
The diesel engine luboil sump tank shall be incorporated in the common bed.
The cylinder jackets, cylinder covers, air cooler and luboil cooler is cooled by fresh water.
The governor shall controlled the speed of engine within the range of 10% of the rated speed for
momentary variation (at the load change required by the Classification Society) and 5% for permanent
variation.
AUXILLARY MACHINERY
DISTILLING PLANT
AIR COMPRESSOR
Th
e ship Service and Control Air Compressor is of air cooled type, and be driven by electric motor through
v-belts.All the compressor and electric motor is mounted as a unit and it have a self contained
lubricating system.
PUMPS
Pump, gear and electric motor is mounted on the common bedplate. The pump and gear, gear and
electric motoris connected by a flexible coupling respectively.Each electric motor is equipped with a
speed control device.
Maker: SHINKO IND. LTD
Type: Centrifugal
Model: DMG100-4AG
Motor Kilowat/RPM : 1050/1800
PURIFIER