MED403 Operations of Main and Aux. Mach.

II– Online Supportive Subject X


8.05.2020
(This doc. Is in used base on simulator class tutorials)

EVAPORATORS (FRESH WATER GENERATOR) AND THEIR OPERATIONS

Fresh water production (through Fresh water generator) from seawater for domestic and auxiliary
purposes is an essential requirement aboard ships. A considerable amount of fresh water is
consumed in a ship. The crew consumes an average 100 litres/head/day. In a steamship (a ship
whose main propulsion unit is the steam turbine or a ship which is a large tanker having steam
turbine driven cargo oil pumps) the consumption for the boiler can be as high as 30 tonnes/day.

Sufficient potable water may be taken on in port to meet crew and passenger requirement. But the
quality of this water will be too poor for use in water tube boilers and for filling expansion tanks. It is
common practice to take on only a minimum supply of potable water and make up the rest by
distillation of seawater. The storage space that would have been used for fresh water can hence be
utilized for fuel or extra space made available for cargo when fresh water generator is installed on
a ship. It is a statutory requirement to have a distillation plant for emergency use if otherwise, a
ship has carried sufficient potable water. The equipment used on board for the production of
freshwater from seawater is known as fresh water generator.

Various types of fresh water generators used on board ships are mainly:

- Submerged tube type fresh water generator


- Plate type fresh water generator, and
- Reverse osmosis plant

Whatever type of plant is used, an essential requirement of any fresh water generator is that it
should produce fresh water as economically as possible.

Submerged Tube Type


The shell and tube freshwater generator consists of a heat exchanger, separator shell and
condenser. In addition to this water ejector, ejector pump, distillate pump, salinity indicator,
demister or mesh separator, solenoid valve and water flow meter are also fitted as accessories.

Working Principle
The basic principle of all low-pressure fresh water generator is that boiling point of water can be
reduced by reducing the pressure of the atmosphere surrounding it. By maintaining a low pressure,
water can be boiled at low temperatures say 50 degree Celsius. The source of heat for the fresh
water generator could be waste heat rejected by main engine jacket cooling water.

Hence using energy from a heating coil, and by reducing pressure in the evaporator shell, boiling
can take place at about 40 to 60 degree Celsius. This type of single effect plant is designed to give
better economy than obsolete Boiling Evaporators.

The submerged tube type fresh water generator explained below uses the heat from main engine
jacket cooling water to produce drinkable water by evaporating seawater due to the high vacuum,
which enables the feed water to evaporate at a comparatively low temperature. Steam can also be
used as a heat source instead of main engine jacket cooling water.
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)

This type of fresh water generator is based on two sets of shell and tube heat exchangers, one
acting as evaporator or heater and other as a condenser.

The combined air/brine ejector creates evaporator chamber vacuum condition by driving seawater
pass through air/brine ejector, and seawater supplied by the ejector pump to be delivered to ejector
for taking out the brine (concentrated seawater) and air. A simple fresh water generator diagram is
shown below.

While entering the evaporator chamber temperature of feed water will be around 50 degree
Celsius. Feed water supply rate to the evaporator is fixed by an orifice fitted at the feed inlet.
Because of the vacuum condition inside evaporator feed water evaporates at this temperature. The
water spray and droplets are partly removed from the vapour by the deflector mounted on top of
the evaporator and partly by a build in demister. The separated water droplets fall back into the
brine, which is extracted by the water ejector.
The desalted vapour, which passes through the demister, will come in contact with the condenser,
where it will be condensed by means of incoming cold seawater.

The distilled water is then taken out by an integral freshwater pump (distillate pump) and controlled
by salinometer and solenoid valve. If the salt content of produced water is high, solenoid valve
diverts the freshwater to the shell side of the freshwater generator and issues an alarm signal. In
order to get better suction head, distillate pump is placed at the lowest possible location in the fresh
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)
water generator plant. This is because the fresh water generator shell is at a lower pressure.
Distillate pump gets maximum net positive suction head with the height of the liquid column in the
suction line.

Thermometers are installed for control of seawater to the condenser and jacket cooling water to the
evaporator. These thermometers permit control of both heating and cooling of these units. The
salinometer or salinity indicator is connected to remote alarm so that very high salinity is
immediately registered at the engine control room of the ship.

Plate Type FWG


Working principle of plate type fresh water generator is same as that of submerged tube type.
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)

Plate Type Fresh Water Generator


type of heat exchangers used. Here plate type heat exchangers are used for condenser and
evaporator unit. Heat from the diesel engine cooling water is used to evaporate a small fraction of
the seawater feed in the plate type freshwater generator or evaporator. Unevaporated water is
discharged as brine (by combined air /brine ejector). The evaporated water passes through the
demister to the plate type vapour condenser. Here, after condensation, it is discharged to fresh
water storage tank by freshwater distillate pump. During the entire operation, the feed rate to the
evaporator is fixed by the orifice plate at the feed inlet to the evaporator. A typical plate type
freshwater generator line diagram is shown below.

In the event of salinity of fresh water exceeding a predetermined value (maximum usually 10 ppm)
the solenoid controlled dump valve diverts the flow back to the shell. This prevents contamination
of the made water. Excess salinity could be used by many factors include leakage of seawater at
condenser or priming of evaporator or malfunctioning of demister or many other reasons.

What cannot be condensed at the condenser are called ‘incondensable gases’ like air and these
gases are continuously ejected out by air/brine ejector. This way the shell of the freshwater
generator is maintained at high vacuum, a must requirement to boil water at low temperatures.

Materials of Construction for Fresh Water Generator


The shell is usually fabricated steel (or non-ferrous metal like cupro-nickels) which has been shot
blasted then coated with some form of protection. One type of coating is sheet rubber which is
rolled and bonded to the plate then hardened afterwards by heat treatment. The important points
about protective coatings are:

1-) They must be inert and prevent corrosion.


2-) They must resist the effect of acid cleaning and water treatment chemicals
3-) They must have a good bond with the metal

4-) The heat exchanger uses aluminium brass tubes and Muntz metal tube plate in the case of tube
type fresh water generator. For plate type, titanium plates are used for condenser and evaporator.
The demister is made of layered knitted wire of monel metal.
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)

Operation

Extreme care must be taken during the operation of fresh water generator onboard ships. Operate
all the valves gradually. Sudden opening and closing of valves may result in thermal shock to the
main engine. Also, make sure that distillate pump never runs dry.
Freshwater Generator Starting Procedure

1-) Make sure seawater ejector pump suction, discharge and overboard valves are open. Start the
ejector pump. Seawater pressure at the air ejector must be 3 bar or more.
2-) Wait for the vacuum to build up inside fresh water generator shell. (About 92 % vacuum).
3-) Open the feed water valve to feed seawater to the evaporator. Adjust the feed water pressure.
Normally marking is provided on the pressure gauge for desired feed water pressure.
4-) Open main engine jacket cooling water inlet and outlet to the evaporator gradually.
5-) Open the air vent clock at the top of the evaporator to make sure the evaporator is filled with
jacket cooling water. Air must be purged out if any.
5-) Switch on the salinity alarm panel for measuring the purity of the freshwater produced.
There will be a sight glass provided at the suction line for the distillate pump. Make sure
condensed water is coming to the suction line. Now start the distillate pump and open discharge
valve to lead generated water to specified storage tanks.
6-) Do checks While Running Freshwater Generator
7-) Through the sight glass provided in the evaporator shell, observe flashing of water.
8-) Also, check for the brine level inside. It should not be too high or too low.
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)
9-) Shell temperature must be around 50 deg cel.
10-) Make sure shell vacuum is more than 90% from the vacuum gauge.
11-) Check seawater inlet and outlet temperature to the condenser.
12-) Ensure seawater pressure at air ejector inlet more than 3 bars.
13-) Check for distillate pump pressure and water flow meter.
14-) Check salinity of fresh water produced.
15-) Check level and flow of dosing chemical.
16-) Check ampere of ejector pump and distillate pump motor.

Regulating the Capacity of Freshwater Generator


The capacity of a freshwater generator means the quantity of fresh water produced by it per day.
The capacity of fresh water generator can be varied by reducing or increasing the amount of jacket
cooling water to the evaporator. The quantity of jacket cooling water to the evaporator can be
adjusted by adjusting the bypass valve provided. When the temperature of jacket cooling water is
comparatively low, the quantity to the evaporator to be increased a bit. At the same time cooling
seawater pressure to the condenser also to be regulated accordingly.

During very low seawater temperatures, evaporation temperature can fall to a lower value. In that
case, adjust vacuum adjusting valve to control vacuum inside the shell. Cooling seawater quantity
to the condenser also can be reduced to increase the evaporator temperature. During high
seawater temperatures, evaporation temperature can go up. In that case, increase the quantity of
seawater to the condenser for reducing evaporation temperature.

Too high evaporation temperature causes scale formation in the heat exchanger. On the other
hand, too low evaporation temperature results in seawater carry over which increases the salinity
of fresh water produced.

The distillate pump discharge to be throttled so that pump should not run dry. The rate of distillate
pump discharge and rate fresh water produced in the condenser should match. When distillate
pump is not able to extract the freshwater at the rate of production, level of freshwater increases in
the condenser and effective cooling area of the condenser reduces. This finally results in reduced
evaporation quantity.

Freshwater Generator Stopping Procedure


When the ship approaches the port, shallow water, etc. it is desirable to stop the fresh water
generator. This is because the seawater may contain harmful bacteria which can enter the
freshwater produced. Operation of freshwater should be carried out in consultation with bridge
watchkeeper. Following procedure may be adopted for stopping fresh water generator.

1-) Slowly open bypass valve for main engine jacket cooling water.
2-) Ensure that main engine jacket cooling water temperature is within normal limits.
3-) Close jacket cooling water inlet and outlet valves for the freshwater generator respectively.
4-) Close the feed water chemical dosing valve.
5-) Stop the distillate pump and shut discharge valve.
6-) Switch off salinity meter.
7-) Close filling valve to freshwater tanks.
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)
8-) Wait for evaporator shell temperature to drop below 50 deg cel.
9-) Close the feed water valve to the evaporator.
10-) Stop ejector pump. Shut fresh water generator overboard valve.
11-) Open the vacuum breaker valve to make shell side pressure equal to atmospheric pressure.
12-) Open the drain valve of the evaporator to drain all the seawater from the fresh water
generator.

Note: Osmosis model is mostly applicable for the pleasure crafts and yachts. They will not be
explained here in this tutorial.

Precautions for Operation of Freshwater Generator

- Seawater pressure at the inlet of air ejector must be 3 bar or more.


- The pressure at ejector outlet should not exceed 0.8 bar.
- Never start fresh water generator distillate pump in dry condition.
- Operate jacket cooling water valves to the fresh water generator gradually to avoid thermal shock
to the main engine.
- Feed water to be supplied for a few minutes to cool down the evaporator before stopping.
- Never open the drain valve of evaporator before opening vacuum breaker. Otherwise,
atmospheric pressure causes seawater inside to hit the deflector.
- How Scale Formation Occurs in Fresh Water Generator
The performance of freshwater generator reduces with the formation of scales because of
reduction in heat transfer efficiency. Three scales which are normally found in freshwater
generators are:

* Calcium Carbonate, CaCO3


* Magnesium Hydroxide, Mg(OH)2
* Calcium Sulphate, CaSO4
Calcium carbonate and magnesium hydroxide scale formation mainly depend on the temperature
of operation. Calcium sulphate scale formation depends mainly on the density of the evaporator
contents or brine. The reaction takes place when sea water heated are:

Ca(HCO3)2 ————> Ca + 2HCO3


2HCO3 ————> CO3 + H2O + CO2
If heated up to approx. 80 degree Celsius

CO3 + Ca ————> CaCO3


If heated above 80 degree Celsius

CO3 + H2O ————> HCO3 + OH


Mg + 2OH ————> Mg(OH)2

Hence if the sea water in the fresh water generator is heated to a temperature below 80 degree
Celsius, calcium carbonate scale predominates. If seawater is heated above 80 degree Celsius,
magnesium hydroxide scale is deposited.
MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)
If the density of evaporator contents is in excess of 96000 ppm, calcium sulphate scales are
formed. But fresh water generator brine density is normally 80000 ppm and less. Hence scale
formation due to calcium sulphate is not a problem.

Hence it is recommended to operate fresh water generator at its rated capacity, not more. More
production of water than rated capacity means a higher concentration of brine and more scale
formation. Similarly higher shell temperatures result in the formation of hard scales which will be
difficult to remove. All these together will reduce the plant efficiency drastically.

How to Minimize Scale Formation

Scale formation in the freshwater generator can be controlled and minimized by continuous
chemical treatment. Polysulphate compounds (like sodium polysulphate) with anti foam is preferred
by marine engineers and is extensively used on ships. Their trade name is different, as an
example:

Vaptreat (by “UNITOR”)


Ameroyal (by “DREW CHEMICALS”)

These chemicals minimize calcium carbonate scale formation and the possibility of foaming. the
compound is non-toxic, no-acidic, and can be used in freshwater generator producing water for
drinking purposes. If would be continuously fed into the feed line using a metering pump or by
gravity. Amount of chemical to be dosed depends on the capacity of fresh water produced.
Important thing is that this chemical is effective only on low-pressure fresh water generators. The
sea water temperature to be less than 90 degrees. Fresh water generator chemical treatment to be
religiously carried out to maintain its performance.

Faults in fresh water generator


Faults in fresh water generator reduce performance of the system, thereby reducing quality and
quantity of freshwater produced on ships. These irregularities must be identified and rectified
immediately to ensure that the optimum performance of the fresh water generator is achieved.

Typical faults in fresh water generator are:

- Loss of Vacuum or Over-pressure of Shell


The shell pressure of the fresh water generator rises and rate of freshwater produced reduces. The
reasons are:

- Air leaks into the evaporator shell in large quantities and air ejector cannot cope.
- The cooling water flow through the condenser is reduced or cooling water temperature is high.
This cause saturation temperature and hence saturation pressure within the condenser to rise.
Malfunctioning of the air ejector.
- The flow rate of the heating medium increased and excess water vapour produced. Since this
excess vapours cannot be condensed, shell pressure increases or vacuum falls.

Salt Water Carry Over


MED403 Operations of Main and Aux. Mach.II– Online Supportive Subject X
8.05.2020
(This doc. Is in used base on simulator class tutorials)

Salt water may be carried over in large quantities during operation of the fresh water generator.
This is called priming. General reasons of the priming are:

- Level of salt water inside the shell is high. When the water level is high agitation due to boiling
occurs and salt water may carry over along with the vapours.
When the salt water brine density is too high, agitation of salt water occurs which results in
priming.
- Increased evaporation rate.

Gradual Increase in Level of Brine

For the satisfactory operation of the fresh water generator, a constant level of brine to be
maintained in the shell. Brine is the concentrated seawater after the liberation of water vapours.
This brine is gradually extracted from the shell. Usually, this is achieved by the combined air-brine
ejector. It extracts air as well as brine from the shell. Any fault in the ejector or brine extraction
pump (in some models) cause the increase in the brine level.
Increase in Salinity of Freshwater

Possible causes are:

Brine level inside shell too high.


Leaking condenser tubes or plates.
Operation of evaporator near shore with contaminated feed water.
Shell temperature and pressure too low.
Increased solubility of CO2 generated from the salt water due to reduced seawater temperature.
This dissolved CO2 makes water acidic and conductivity of water increases. Hence salinometer
shows increased salinity, which is a measure of conductivity and not the presence of salt.

References:
Diesel Ship
Marinedesk portal
Marine online

Additional supportive materials: (Pls. kindly watch them!!)


https://www.youtube.com/watch?v=IPvZsNUopJ0
ALFA LAVAL https://www.youtube.com/watch?v=kTJRm7daRls
Simulation of operation: https://www.youtube.com/watch?v=JoAPhr1K--E

Cleaning: https://www.youtube.com/watch?v=_BgBYl9Mhno
https://www.youtube.com/watch?v=_qceKrGI5B8
https://www.youtube.com/watch?v=zB-mFlJhfpo

You might also like