PENGUKURAN CAMSHAFT KERAX-380

KESIMPULAN
NO GAMBAR KERJA NAMA COMP. MEDIA INSPEKSI HASIL INSPEKSI
Layak Tidak Layak
3 Camshaft Magnet base Round Out(Lengkungan)
Dial Gauge Repair Limit : 0,03mm Inspeksi Actual :0.02mm Layak
Rotasi 360 ° Journal

Micrometer Cam Lobe


0-100mm Repair Limit Inspeksi actual Layak

IN : 82,38 mm Clyd 1 2 3 4 5 6
IJ : 84,80mm IN 82,50mm 82,48mm 82,40mm 82,42mm 82,48mm 82,40mm
IJ 84,82mm 84,90mm 85,00mm 84,86mm 84,90mm 84,86mm
EX : 74,80mm EX 74,86mm 75,00mm 74.88mm 74,86mm 74,86mm 75,00mm