REPORT ON SIEVE ANALYSIS

Construction of Central Workshop Building at NRL Site N R L


DATE : REV : Date & Time :
ITP NO : REV DATE : REPORT NO :
00
REFERENCE WMS NO: QAP NO :
DATE OF RECEIPT : Source : Wt of Sample Taken(gm)
A FINE AGGREGATE

WEIGHT ZONE ( AS PER IS 383) REMARKS


SL SIEVE PERCENTAGE CUMULATIVE % FINENESS
RETAINED % PASSING
NO SIZE RETAINED RETAINED MODULUS
(gm) ZONE I ZONE II ZONE III ZONE IV
1 10 mm 100 100 100 100
2 4.75 mm 90-100 90-100 90-100 95-100
3 2.36 mm 60-95 75-100 85-100 95-100
4 1.18 mm 30-70 55-90 75-100 90-100
5 600 µ 15-34 35-59 60-79 80-100
6 300 µ 5 to 20 8 to 30 12 to 40 15-50
7 150 µ 0-10 0-10 0-10 0-15
8 Pan

Reference : Mix-Design Stipulation,IS 2386 Part III,IS 383, Technical Specification/MORTH


Remarks :

RBEIPL (QC) CLIENT/PMC