SERVICE REPORT
CONTENTS
Bridge monitor
-AFT computer case is faulty and out of service and it does not turn on. Power supply checked,
connections checked and found that the computer is faulty and need to be landed to service and
repaire.
-Also FWD computer case is faulty and need to be landed to service and repaire.
Faulty computer
-InteliGen marine module on STBD engine panel is faulty and need to repaire and service if it is
possible, also its fault couses to prevent data transfer between STBD main engine and bridge
computer of Alarm Monitoring system.
-There are some faults in Modbus connections and Modbus units that needed to be checked.
-LAN connections between FWD and Bridge alarm monitoring system, suddenly loses their
connections and its protocol is not proper for this system.
-The PLC units (AFT and FWD) does not work properly and for more tests and fault finding it need
to be landed to Diaco Pars Co.
PLC units
It recommended, FWD and AFT alarm monitoring computers, PLC units of AFT and FWD panels,
faulty intelliGen module of STBD main engine and inteliGen module of PORT main engine with its
analogue card land to Diaco Pars Co. to more tests, fault finding and repaire.
All sensors of system need to be tested and calibrate.
System need to be test after repaire and above actions.
3 MATERIALS
3.1 Broken / landed
Qty Description: Part No.: Serial number Sent to Responsible
2 Pc panel DIACO
1 OMRON PLC CPU33 DIACO
(AFT)
2 Inteli drive comap Dcu DIACO
marine
1 Comap-i-ain8 DIACO
1 OMRON PLC CPU33 DIACO
(FWD)
5 REMAINING WORK
6 OTHER MATTERS
7 CONFIRMATION OF WORK
Diaco Pars Co. Service Engineer:
8 TIME SHEET
NUMBER TIME
OF
PERSON* Working
Date Onboard DISCRIPTION
Travel Time of Time of
Time Join Disembark Time
Eng Tech
NT OT
Travel from Isfahan –Bandar Amir Abad by
29-NOV-2021 3 11:00 9:00 8 2
car and join to the VSL and work onboard
30-NOV-2021 3 8 0 work onboard
NUMBER TIME
OF
Date PERSON Travel path
Travel Time
Eng Tech
Diaco Pars CO