Cartonator DQ observation against DQ

1. Page no 11/40 along with operation manual, service or maintenance manual


should be include.
2. Page no 23/40 Output should be 180carton/minute but they mention 150
carton/minute. As per URS need to update.
3. Page no 23/40 carton size length should be changed as per URS.
4. Page no 26/40 layout shall be attached in DQ.
5. Page no 23/40 Dimension of Equipment not mentioned in DQ against GA
Drawing.
6. Machine intend to use 7 to 7:30 hrs. in a shift of 8hrs. not available in DQ
7. Non flame proof electrical panel shall be mention in DQ.
8. Regulatory requirement of Equipment shall be mentioned for local FDA, EU-
GMP also.
9. Leaflet rejection % limit not mentioned in DQ.
10. Machine performance percentage not mentioned in DQ.
11. About camera performance mention in separate table and 21CFR not
mentioned.
12. List of spares not mention or not given in DQ.

Cartonator DQ observation against ACG DQ

1. Page no 11/40 along with operation manual, service or maintenance manual


should be include.
2. Page no 23/40 Output should be 180carton/minute but they mention 150
carton/minute. As per URS need to update.
3. Page no 23/40 carton size length should be changed as per URS.
4. Page no 26/40 layout shall be attached in DQ.
5. Page no 23/40 Dimension of Equipment not mentioned in DQ against GA
Drawing.
6. Machine intend to use 7 to 7:30 hrs. in a shift of 8hrs. not available in DQ
7. Non flame proof electrical panel shall be mention in DQ.
8. Regulatory requirement of Equipment shall be mentioned for local FDA, EU-
GMP also.
9. Leaflet rejection % limit not mentioned in DQ.
10. Machine performance percentage not mentioned in DQ.
11. About camera performance mention in separate table and 21CFR not
mentioned.
12. List of spares not mention or not given in DQ.
Cartonator DQ observation against ACG DQ

1. Page no 11/40 along with operation manual, service or maintenance manual


should be include.
2. Page no 23/40 Output should be 180carton/minute but they mention 150
carton/minute. As per URS need to update.
3. Page no 23/40 carton size length should be changed as per URS.
4. Page no 26/40 layout shall be attached in DQ.
5. Page no 23/40 Dimension of Equipment not mentioned in DQ against GA
Drawing.
6. Machine intend to use 7 to 7:30 hrs. in a shift of 8hrs. not available in DQ
7. Non flame proof electrical panel shall be mention in DQ.
8. Regulatory requirement of Equipment shall be mentioned for local FDA, EU-
GMP also.
9. Leaflet rejection % limit not mentioned in DQ.
10. Machine performance percentage not mentioned in DQ.
11. About camera performance mention in separate table and 21CFR not
mentioned.
12. List of spares not mention or not given in DQ.
Cartonator DQ observation against ACG DQ

1. Page no 11/40 along with operation manual, service or maintenance manual


should be include.
2. Page no 23/40 Output should be 180carton/minute but they mention 150
carton/minute. As per URS need to update.
3. Page no 23/40 carton size length should be changed as per URS.
4. Page no 26/40 layout shall be attached in DQ.
5. Page no 23/40 Dimension of Equipment not mentioned in DQ against GA
Drawing.
6. Machine intend to use 7 to 7:30 hrs. in a shift of 8hrs. not available in DQ
7. Non flame proof electrical panel shall be mention in DQ.
8. Regulatory requirement of Equipment shall be mentioned for local FDA, EU-
GMP also.
9. Leaflet rejection % limit not mentioned in DQ.
10. Machine performance percentage not mentioned in DQ.
11. About camera performance mention in separate table and 21CFR not
mentioned.
12. List of spares not mention or not given in DQ.