You are on page 1of 3

A4: Generator Input-Output Characteristics

Mark Jaworski Cadayong


October 08, 2021

Case A: Plot input-output Characteristics with the assumptions of 20MW to 100MW.

P1 H1 H2 Problem A: Input-Output Characteristics


20 240.96 256.00 1200.00
25 281.50 295.00
1000.00
30 322.16 336.00
35 362.94 379.00 800.00
40 403.84 424.00
600.00
45 444.86 471.00
50 486.00 520.00 400.00
55 527.26 571.00 200.00
60 568.64 624.00
65 610.14 679.00 0.00
0 20 40 60 80 100 120
70 651.76 736.00
75 693.50 795.00 H1 H2
80 735.36 856.00
85 777.34 919.00
90 819.44 984.00
95 861.66 1051.00
100 904.00 1120.00
A4: Generator Input-Output Characteristics
Mark Jaworski Cadayong
October 08, 2021

Case B: Calculate net Heat Rate in BTU/KwHr

P1 NHR1 NHR2
20 12,048.00 12,800.00
25 11,260.00 11,800.00
Problem B: Net Heat Rate Characteristics
30 10,738.67 11,200.00 14,000.00
35 10,369.71 10,828.57 12,000.00
40 10,096.00 10,600.00 10,000.00
45 9,885.78 10,466.67
8,000.00
50 9,720.00 10,400.00
6,000.00
55 9,586.55 10,381.82
60 9,477.33 10,400.00 4,000.00
65 9,386.77 10,446.15 2,000.00
70 9,310.86 10,514.29 -
75 9,246.67 10,600.00 0 20 40 60 80 100 120
80 9,192.00 10,700.00
NHR1 NHR2
85 9,145.18 10,811.76
90 9,104.89 10,933.33
95 9,070.11 11,063.16
100 9,040.00 11,200.00
A4: Generator Input-Output Characteristics
Mark Jaworski Cadayong
October 08, 2021

Case C: Calculate the Increment production cost in $/MWh

P1 IPC1 IPC2
20 18.07 19.20 Problem C: Incremental Production Cost
25 16.89 17.70 25.00
30 16.11 16.80
35 15.55 16.24 20.00

40 15.14 15.90
15.00
45 14.83 15.70
50 14.58 15.60 10.00
55 14.38 15.57
60 14.22 15.60 5.00
65 14.08 15.67
0.00
70 13.97 15.77
0 20 40 60 80 100 120
75 13.87 15.90
80 13.79 16.05 IPC1 IPC2
85 13.72 16.22
90 13.66 16.40
95 13.61 16.59
100 13.56 16.80