1 Data Concentrator not working EMD 2 Bus Voltage/Current not available in OWS EMD 3 220 V DC Battery Charger parameters not available in OWS EMD/C&I 4 EERM 1A1 not available EMD/AHD 5 Offsite bus scheme not available in OWS EMD 6 24V battery bank charger/UPS scheme not available in OWS EMD/C&I 7 All buses breaker nomenclature not available in OWS EMD/C&I 8 Module lock of breakers/panels broken EMD 9 ESP hopper heaters taking less current and all are not on EMD 10 220 V DCDB earth fault EMD 11 ESP hopper transformer earthing key removal (Locking) not av EMD 12 ST oil temp high faulty alarm appearing EMD 13 3.3 kv/415v Staion service transformer-2 marshling box supply is not available EMD 14 Oil Lkg in CT transformer-3, UAT-1, GT RY EMD 15 ID Fan-A channel-1 PRV (limit switch) defective EMD 16 ID Fan-B channel-1/2 PRV (limit switch) defective EMD 17 GRAVEL is not available in ID FAN-B channel-1/2 EMD 18 Breather Sillica gel colour is pink in MISC AUX TRF-1 (fire water) EMD 19 LED not working in CT#6DB MCC Module- 1F1, 31F1, 16F1, EMD 20 LED not working in RODM MCC Module- 1F1 EMD 21 LED not working in ODD( fire water) MCC Module- 7R3 EMD 22 LED not working in MISC. 0 QA MCC Module- 1F1 EMD 23 LED not working in UES 6DG MCC Module- 27F1, 15F1, 2F1 EMD 24 LED not working in Station Service ODA MCC Module- 15F1, 12F2 EMD 25 LED not working in Unit Service 6DA MCC Module- 16F1, 16F2, 13F2, 12F1, 10F1, 1F1 EMD 26 LED not working in TURBINE 6KA MCC Module- 17F1 EMD 27 LED not working in 6QA MCC Module- 1F4, 13F4 EMD 28 LED not working in BOILER 6HC MCC Module- 1F4, 6F1 EMD 29 LED not working in BOILER 6HA MCC Module- 1F1, 8F1 EMD 30 LED not working in AC OTA MCC Module- 9F1 EMD 31 ACMCC # OTA Module no- 2F1 is not available EMD 32 AC EMERGENCY MCC # OTB Module no- 1F1 is not available EMD 33 MISC. Service # 0QA module 16F1 is not available EMD 34 UNIT SERVICE ACDB # 6QA Module 7F1 is not available EMD 35 220 DCDB Battery Charger-1 volt meter defective EMD 36 LTMCC Pass-D module 13F1 breaker shutter defective EMD 37 ESP PASS-D TRF-1 WTI reading error EMD 38 TDBFP –A one LOP should be at TMCC EMD 39 TDBFP –B one LOP should be at TMCC EMD 40 One BCW Emergency Fill pump supply should be at DG Board EMD Coal feeder-A,C,E,G,J three phase supply from section-1 and feeder –B,D,F,H Supply from 41 section-2 of 6HC Board EMD Coal feeder-A,C,E,G,J single phase supply from section-1 and feeder –B,D,F,H Supply from 42 section-2 of 6HC Board EMD 43 IAC lube oil pump supply to be provided with 6DG Bus EMD 44 DCS to be commissioned for auto logic( Stage -4 service building DCS) ID Fan EMD Total 03 no. and 02 no. ERVs supply coming from single module of 220V DCDV 45 Board. Each ERV should be supplied from separate EMD 46 PAPH -A and PAPH -B main motor drive should be from 6DG Board EMD Contactor auto logic to be commissioned, if one fail other will pick, Both isolator will 47 be made on EMD All breaker mimic to be provided in DCS, Remote (CCR-6) operation to be provided of 48 Station auxiliary board (Fire MCC) EMD 49 AC plant Incommer-1 (OTA) not avaialble. To be made available at the earliest EMD 50 AC PLANT (OTB), RODM and PT PLANT on single source EMD 51 ESP 415 V Breaker inoperative from remote EMD GT MB supply-1, 2 from section-2 of 6DA and section-2 of ODA bus. ONE source 52 should be from any section of 6DG board. EMD 53 ALL ERV and MS , CRH, HRH releving valve module cable to be provided EMD 54 MVAR transducer to be changed EMD 55 400 KV BUS-1 Voltage tx-1 EMD 56 Offsite and ash handling switch gear breaker remote and auto operation not available EMD 57 H2 drier i/l o/l due point measurement to be provided. EMD/C&I 58 Generator slot temp 13 to 19 erratic EMD/C&I 59 H2 purity meter to be commissioned. Line leakage to be attended EMD/C&I 60 Bus duct pressurization unit not working EMD 61 GCB LA showing zero leakage current EMD 62 Primary Water conical filter choking EMD 63 CT Fan-A7 module not available EMD 64 Generator End winding Vibrations running on higher side EMD 65 Generator Field Voltage and Current value not availble in OWS EMD 66 415V Fuel Oil MCC (0DB) Incomer-1 &2 are crossed EMD 67 415V Service Building MCC (0DC) Incomer -1 & 2 are crossed EMD 68 415V Make Up Water MCC (0DE) Incomer -1 & 2 are crossed EMD 69 3.3KV Miscelleneous MCC (0CA) Incomer-1 & 2 are crossed EMD 70 415V Fire Water MCC (0DD) Incomer -1 & 2 are crossed EMD 71 415V ESP LT MCC-C (6DE) Incomer -1 & 2 are crossed EMD 72 415V CT MCC (6DB) Incomer -2 & 3 are crossed EMD