ELECTRONIC TRAP PRIMING DEVICE


S270SM SERIES
DRAWING NUMBER

WITH SURFACE MOUNT ENCLOSURE


WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA

1/2"(13) NPTF Inlet


Electrical Connection Water Connection
Hard Wired Screwdriver Style
Stop Valve
Control Panel
SIZE

SMITH 2669
TRAP PRIMER Vacuum
Breaker
NONE

Surface Mount Enclosure


With Cover TIMER TEST
SCALE:

10(254) x 10(254) x 4(102)


(NEMA 1 Box) Solenoid
Valve
4-24-19

WORKING PRESSURE:
20 PSI (138kPa) to Manifold
DATE:

100 PSI (689 kPa)

Compression Fittings
Shown in Illustration
APPROVED BY:

270SM-08-500-120
JM

REGULARLY FURNISHED:
A Surface Mount, Floor Drain Trap Priming Device consisting of
270SM-XX-XXX-XXX
DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE

Enclosure with Cover, a Solenoid Valve, Vacuum Breaker, a UP


Timer (factory preset to discharge once per twenty-four-hour C
period) and a Manifold with multiple Compression Discharge Voltage
®
CHECKED BY:

Ports (specify number of outlets) allowing the unit to serve Outlet Size FILE 3253
JM

multiple floor drain traps. This device is supplied with hardwired Number of Outlets NRTL
type electrical connections and has provisions to interface with ®
IA
a Building Management System (BMS) where applicable. Surface Mount PM
O
EGS
SPECIFY AC VOLTAGE: HARDWIRED Figure Number C US
24V -024 UL 1951
TBW

120V -120
DRAWN BY:

CSA C22.2 NO 68
240V -240 CSA C22.2 NO 14
SPECIFY NUMBER OF OUTLETS: FILE E10084
VARIATIONS:
04 06 08 10 12 Vandal Proof Cover Screws -U
14 16 Interface with Facilities Energy Management System -EMS
270SM SERIES

SPECIFY OUTLET TYPES:


1/2"(13) OD Compression Fittings -500
5/8"(16) OD Compression Fittings -625
NOTES:
• All wiring must follow and be in accordance with National, State and Local Electrical Codes.
• The outlet of the trap primer valve shall be a minimum of 12"(305) above the finished floor before a 90º elbow can be
installed. See Installation Instructions.
• Dimensions shown in parentheses are millimeters unless otherwise specified. STD. 1044
• Unit must be installed level and be accessible.
J 12-15-20 Revised Reg Furn. /Callout TBW CL
H 04-29-20 Revised ASSE/UPC Conformities MW CL
WEIGHT VOLUME FIGURE NUMBER
POUNDS CUBIC FEET
G 04-23-20 Added UPC MW CL
270SM SERIES
NUMBER
FIGURE

F 02-28-20 Added IAPMO EGS Conformity MW CL


REV. DATE DESCRIPTION BY CKD. BY

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov