You are on page 1of 11
Day 26 - EXAM | 26-1 Power and Industrial Piant Engineering DAY 26 - EXAM jumping water level and static water vel. A. total head 8. siatichead Cc. pump level ‘D. draw-down 2. An underground formation that contains sufficient saturated permeable material to yield significant quantities of water. aquifer B. wet pit ©. cavitation D. 3. > . NPSH Is the rate of flow of liquid measure per unit of time. A. capacity B. pump work C. velocity D. pump head 4 ‘The reading of a pressure gage at the discharge of the pump plus velocity head at the point of gage attachment. A. total discharge head B. total head . NPSH D. suction head 5. A type of valve installed between the suction of pump and water mains to prevent any return of water to mains when pump is stopped. A. globe valve B. suction valve C. discharge vaive D. check valve 6. A gauge in the form of a glass one tube leg of which is open to the atmosphere, or a straight tube one end of which is open to the atmosphere. A. manometer B. differential 4. The.vertical difference between the C. piezometer D. compound 7. The following are classifications of pumps except . centrifugal reciprocating radial flow rotary VOD> 8 The following are reciprocating pumps, except: A. piston B. peripheral C. plunger D. diaphragm types of 9. The following are types of rotary pumps, except: A. vane B. screw C. gear D. duplex 40. The following are types of centrifugal pumps, except: A. hydraulic B: axial C. mixed D. radial 11. Valve designed = to automatically to relieve pressure. A. check valve B. relief valve C. gate valve D. medium vaive open excess 412. is a hollow product of round or any other cross section having a continuous periphery. A. pipe B. tube C. valve D. coupling 43. A large pipe or drum into which each of a group of boilers is connected. A. muffler 26 -2 | Day 26 - EXAM B. header CS. manifold D. expansion loop 14. Medium pressure, when applied to valves and fittings, implies they are suitable for a working pressure of from kPa, A. 862 to 1207 B. 1207 to 1506 C. 955 to 1345 D. 1345 to 1750 45. All piping shall be run to building walls. A. opposite B. parallel C. inclined D. slope 46. Piping supports shall be placed mm intervals or less. A, 3000 B. 4000 C. 4500 D, 6000 47, Piping color for boiled feed water: A. green B. yellow C, red D. black 48. Piping color for acids: A. yellow B. blue C. orange D. red 49, Piping color for oxygen and oil: A. green B. black C. white D. orange 20. Piping color for low-pressure air: A. green y B. yellow C. white D. orange 21. Piping color for high pressure wali and hot water: A. silver B. yellow C, red D. green 22. Piping color for LPG, ‘high vacuul and producer gas: A. safety red B. orange Cc. red D. no color 23. Which of the following statements) for piping system is correct? A. all piping to headers shall come from below rack B. all piping from headers shall do up above rack C. ali piping shall be reasonably cleaned before installation D. all of these 24, A fitting with a number of branches in line connecting to smaller pipes. A. manifold B. smail pipes C. major pipe D. vaive 25. A large radius bend in a pipe line to absorb longitudinal expansion in the line: due to heat. A, expansion loop B. expansion joint C. compression joint D. compression loop ;. 26. Color bands on pipes to identify pipe color is painted every if A. 2000 mm B, 4000 mm C, 2500 mm D. 4500 mm 27. In practice, the average fluid flow velocity for water is 6 A. 1.5=3 m/s B. 15-30 m/s Day 26 - EXAM | 26-3 Power and industrial Plant Engineering » 10-20 m/s 50 -70 mis . To identify pipe flow, arrows will be Motations, except: arrows shall be in different color as banding atrows shall be stencil type ; arrows shall be readable from floor arrows shall be installed every 4500 As a general requirement for piping, 1 piping ___. and above shall be anged while smaller sizes can be Screwed, 50mm 5. 63.5mm . 60 mm : As a general requirement for piping, piping supports shall be placed on a 3000 mm intervals or less and a inimum factor of safety of for eee pressure applied shall be 31. What is the freezing point pf R-22 at atmospheric? -256 °F B. 150°F . -252 °F 32°F What is the freezing point.of R-134 at 1 atmospheric? A -91.9°F E -141.9°F 41.1°F , -121°F 33. Whatis the freezing point of R-12 at atmosphere? _440r Painted on pipes. All of the following are’ | B. -252°F -C. -101°F D, -460°F 34. The boiling point atmosphere is: A. 79.9°F B. -11°F C. -74.9°F D. 17°F 35. The boiling point of R-22 at 7 atmosphere is: A. -21.4°F B, -61.4°F C. -414°F - D. 70°F RAt at 4 36. The boiling point of R134 at t atmosphere is: A. -61.19F B. 25°F C. 50°F D. -15.08°F 37. The chemical name of Refigsrant 42 is: A. dichlorodifiuoromethane B. trochlorodifluoromethane C. dichloromethane D. methyl chloride 38. The chemical name of R-22 is A. dichloromethane B. chiorcdifluoromethane C. monochlorodifiluorometians D. ethane chloride 39. The chemicalname Of R-134a is: A. chlorotrifluoromethanc B. hydrocarbon C. tetrafluoroethane D. trochloroethane 40. Group B refrigerants are A. toxic B. lethal C. harmful D. all'of the above 26 - 4 | Day 26 - EXAM 41. Which of the following is NOT an oil suitable for use with R-134a? A. Mineral oil-based lubricant B. Polyolester C. Alky! benzene D. Polyalkylene glycot 42. Which of the following is an HFC refrigerant? A. R114 B. R22 C, R-134a D. R-113 43, Which of the following is an HCFC refrigerant? A. R114 B. R-113 Cc. R-22 D. all of these 44, Which of the following is a refrigerant blend? A. azeotropic B. HFCs Cc. CFCs D. HCFCs 45. What is HFC? A. hydrogenfreecarbon B. hydrechlorofluorocarbons C. hydrochlorocarbons D. hydrofiuorocarbons 48. A type of refrigerant which is non- toxic, noncorrosive, nonirritating, and nonflammable. It is a synthetic refrigerant developed for installations that. need a low evaporating temperature. A, Ammonia B. carbon dioxide Cc. R-500 D. R-22 47. A type of tefrigerant which is nontoxic, nocorrosive, and nonflammable. It is used as a replacement for R-12. A refrigerant which is compatible with polyol ester oil. Presently being used as a standard refrigerant in vehicular air conditioning. A. R-134a B, R-717 C. R-502 D, R-123 48, A type of refrigerant which is coloriess and almost _ odorless refrigerant. It is nontoxic, noncorrosive, nonirritating and nonflammable. A, R-14 B. R-507 G, R12 DL NHs 49. The cylinder code color for R-22 is A. white B. yellow C, tan D. light green » 50, The cylinder code color for R-134a is y A. sky blue B. red C. light orange D. white 51. Refrigerant which is a mixture of two or more substance. A. azeotropic B. zeotropic C. hydrocarbon D. monocarbon 52, A type of Group B refrigerants | which is commonly used in industrial” systems. A. methyi chloride B. sulfur dioxide C. R-123 D. Ammonia 3. The boiling temperature of ammonia at atmospheric temperature is 20 B. -108°F Day 26 - EXAM | 26-5 Power and Industrial Plant Engineering , -33F . -150°F Refrigerant ammonia corrodes rand bronze, {t does not corrode stainless steel . chromium |. manganese Cryogenic temperatures ranges m es -250 to -460°F -50 to -100°F . -120 to ~150°F D. 10 to -50°F 56. What does the word “ozone” scribe? a thin layer in the earth's upper josphere: 8. a protective layer for the earth ‘C. A filter for the sun's ultraviolet rays DB. all of the above 57. The service cylinders: are filled with refrigerants up to full for safe limit and to avoid bursting of cylinders. CS. 80% D. 100% 58. Liquid refrigerant expands with a/an in temperature. Cylinders filled with cold or cool refrigerant will burst if allowed to warm up. A. decrease B. normal C. increase D. unknown 59. is an HCFC used as a replacement for R-11. A. R-707 B. R-110 C. R-501 D. R-123 60. Refrigerant 22 has good solubility in oil. Leaks may be detected by. A. soap solution B. electronic detector C. halide torch D. all of these ‘ 61. The chemical symbol of R-22 is: A. CHCIF2 B. CCIF2 C. CHF D. CHCIHAF 62. The chemical symbol of R-134a is: A. CFCHF2 B. CFsCH2F C. CCHF. D. FCH2CI 63. Ammonia is refrigerant: A. R-505 B. R-717 Cc, R40 D. R502 64. The chemical symbol of R-12 is: A. CChF2 B. CFCIFs Cc, CHCl. D. CHNF2 65. A synthetic chemical refrigerant, which is considered to be low-pressure refrigerant. A. R14 B. R-22 Cc. R-12 D. R-502 26 - 6 | Day 26 - Solution MAY 26 — ANSWER KEY fi or >>O A .D A Cc 3. B dD A |. B 16.A 31.A46.D61.4 32.B47.A62.B $3.B48.C63.8 34.A49.D 64.4 35. C50.A65.A 36.D51.8 37.A52.D 38.863. 39.054.B 40, D55.4 41.A56.D 42.657.C 43,058. C 44.A59.D 45,060.D DAY 26 - SOLUTION 4, The vertical difference between the pumping water level and static water level. A. total head B. static head C. pump level D. draw-down * 2.’ An underground formation that contains sufficient saturated permeable material to yield significant quantities of water. A. aquifer* B. wet pit C. cavitation D. NPSH 3._ Is the rate of flow of liquid measure per unit of time. A. capacity * B. pump work C. velocity D. pump head 4. The reading of a pressure gage the discharge of the pump plus veloci head at the point of gage attachment. A.’ totabdischarge head * B. total head Cc. NPSH D. suction head 5. A type of valve installed between suction of pump and water mains prevent any return of water to mai when pump is stopped. A. globe vaive B. suction valve C. discharge vaive D. check vaive* 6. A gauge in the form of a glass tube leg of which is open to atmosphere, or a straight tube one of which is open to the atmosphere. A. manometer * i B. differential C. piezometer D. compound Day 26 - Solution | 26 -7 Power and Industrial Plant Engineering 7. The following are classifications of pumps except: A, centrifugal B. reciprocating C. radial flow* D. rotary 8. The following are types of reciprocating pumps, except: A. piston B. peripheral « C. plunger D. diaphragm 9. The following are types of rotary pumps, except: A. vane B. screw C. gear D. duplex* 10. The following are types of centrifugal pumps, except: A. hydraulic * B. axial C. mixed D. radial 11. Valve automatically pressure. A. check valve 8. relief valve * C. gate valve D. medium valve designed to to relieve open excess 12. is @ hollow product of round or any other cross section having a continuous periphery. A. pipe B. tube* C. valve D. coupling 13. A latge pipe or drum into which ach of a group of boilers is connected. muffler . header ™ . Manifold . expansion loop COM> 14. Medium pressure, when applied to valves and fittings, implies they are suitable for a working pressure of from kPa. A. 862 to 1207 * ! B. 1207 to 1506 C. 955 to 1345 D. 1346 to 1750 15. All piping shall be run building walls. A. opposite B. parailel* C. inclined D. slope to 16. Piping supports shall be placed mm intervals or less. A, 3000* B. 4000 C. 4500 D. 6000 17. Piping color for boiled feed water: A. green B. yellow* C. red D., black 18. Pipihg color for acids: A. yellow * B. blue C. orange D. red 19. Piping color for oxygen and oil: A. green B. black C. white D. orange * 20. Piping color for low-pressure air A. green* B. yellow C. white D. orange 21. Piping color for high pressure water and hot water: 26 - 8 | Day 26 - Solution A. silver B. yellow * C, ted D. green 22. Piping color for LPG, high vacuum and producer gas: A. safety red B. orange * C. red D. no color 23. Which of the following statements for piping system is correct? A. all piping to headers shall come from below rack 8. alf piping from headers shail do up above rack C, all piping shall be reasonably cleaned before installation D, all of these * 24. A fitting with a number of branches. in line connecting to smailer pipes. A. manifold * B. small pipes C. major pipe D. valve 25. A large radius bend in a pipe fine to absorb longitudinal expansion in the fine due to heat. A. expansion loop * B. expansion joint C. compression joint D. compression loop 26. Color bands on pipes to identify pipe color is painted every A. 2000 mm B. 4000 mm CG. 2500 mm D. 4500 mm* 27. In practice, the average fluid flow velocity for water is i A. 15-3 mis * . B. 15-30 m/s C. 10-20 mis D. 50-70 mis 28. To identify pipe flow, arrows will be painted on pipes. All of the following are notations, except: A. arrows shall be in different color as pipe banding * B. arrows shall be stenciltype —_* C. arrows shall be readable from floor D, arrows shall be installed every 4500 mm. 29. As a general requirement for piping, all piping and above shall be flanged while smaller sizes can be screwed. A. 50mm B. 63.5 mm * Cc. 60mm D. 93.5mm 30. As a general requirement for piping, piping supports shall be placed on a 3000 mm intervals or less and a minimum factor of safety of for working pressure applied shall be used. A. two. B. four* C. three D. five 31. What is the freezing point pf R-22 at 4 atmospheric? A. -256°F * B. 150°F , =252°F 032 32. What is the freezing point of R-134 at 1 atmospheric? A. -91.9°F B. -141.9°F * C. 41.1°F D. -121°F 33. What is the freezing point of R-12 at 4 atmosphere? AL -41°F B. -252°F* CG. ~101°F D. -460°F Day 26 - Solution | 26 - 9 Power and Industrial Plant Engineering § The boiling point R-11 at 1 sphere is: 79.9 °F * 11°F -74.9°F ‘ie The boiling point of R-22 at 1 josphere is: -21,.4°F -61.4°F -41.4°F * 70°F The boiling point of R-134 at 1 josphere is: -61.1°F 25°F B50°r -16.08°F * . The chemical name of Refrigerant ist dichlorodifluoromethane * trochlorodifluoromethane . dichloromethane methyl chloride . The chemical name of R-22 is: dichloromethane chlorodifluoromethane * . monochlorodifiluoromethane . ethane chloride 32. The chemicalname Of R-134a is: ‘A. chlorotrifluoromethane 8B. hydrocarbon ©. tetrafiuoroethane * ‘BD. trochloroethane 40. Group B refrigerants are A. toxic 6. lethal . harmful 'D. all of the above * 44. Which of the following is NOT an oil suitable for use with R-134a? A. Mineral oil-based lubricant * B. Polyolester C. Alkyl benzene D. Polyalkylene glyco! 42. Which of the following is an HFC refrigerant? A. R-114 « B. R-22 C. R-134a* D. R-113 43. Which of the following is an HCFC refrigerant? A. R-114 B, R-113 C. R-22* D. ail of these 44. Which of the following is a refrigerant blend? A. azeotropic * B. HFCs C. CFCs D. HCFCs 45, What is HFC? A. hydrogenfreecarbon B. hydrochlorofluorocarbons G. hydrochlorocarbons D. hydrofluorocarbons * 46. A type of refrigerant which is non- toxic, noncorrosive, nonirritating, and nonflammabie. it is a synthetic refrigerant developed for installations that need a iow evaporating temperature. A, Ammonia B, carbon dioxide G. R-500 D. R-22* 47. A type of refrigerant which is nontoxic, nocorresive, and nonflammable. lt is used as a replacement for R-12. A refrigerant which is compatible with polyol ester oil. Presently being used as a standard refrigerant in vehicular air conditioning. A, R-134a* B. R-717 26-10 | Day 26 - Solution CG. R502 D. R-123 48. A type of refrigerant which is colorless and almost odorless refrigerant. It is nontoxic, noncorrosive, nonirritating and nonflammabie. A. R-11 B. R-507 Cc, R-12* D. NHs 49, The cylinder code color for R-22 is A. white B. yellow C. tan D. light green * 50. The cylinder code color for R-134a is ‘ A. sky blue* B. red C. light orange D. white 51. Refrigerant which is a mixture of two or more substance. A. azeotropic B. zeotropic* C. hydrocarbon D. monocarbon 52.

You might also like