You are on page 1of 7

PROCESS FLOW DIAGRAM Doc.No.

QMS-F-15
Capillary tube assy (3P355507-1A) Rev.Date-00/01-10-13
Receiving of Raw Material Receiving of Raw Material
Cu 6.35*0.7,6.4*0.8 mm(C1220TS-O) Capill OD 3.2*ID-1.8 mm(C1220T-OL)

IQC IQC
Reject
Not OK Not OK
OK Ok

Cutting Cutting

PQC PQC
Reject
Not OK Not OK
OK Ok

De Burring De Burring

Air Blowing
Air Blowing

PQC PQC
Reject
Not Ok
OK Not ok Ok

Expanding
Beading

Ok
Not Ok PQC
PQC Reject
Not Ok
OK
Blockage
Not Ok Testing
Reject
Expanding
Ok
Bending

PQC Not Ok PQC


Reject

Cleaning & N2 Blowing

To (A)

PQC
PROCESS FLOW DIAGRAM Doc.No.QMS-F-15
Capillary tube assy (3P355507-1A ) Rev.Date-00/01-10-13 TO
(A) TO
(B)

Brazing
Final Fitment
(Reducer+Capill)

Contamination testing
PQC 25mg/m²
Reject

Ok Not ok Not OK
OK

Blockage Testing
N2 Blowing & End
Reject Capping /Packing
Not OK
OK

Leakage Test
OK

OQC
O
Gauging Reject
Not OK
Ok
PQC Not OK
OK

QC Certify & Despatch


Capillary flow testing
11L/min

PQC Not ok Reject


Ok

To (B)

LEGEND:
IQC : INCOMING QUALTIY CONTROL
PQC: PROCESS QUALTIY CONTROL
OQC: OUTGOING QUALTIY CONTROL

REV.NO DATE AMENDMENTS

PREPARED BY CHECKED BY APPROVED BY


PROCESS FLOW DIAGRAM Doc.No.QMS-F-15
Auxiliary inlet pipe assy (3P357458-1) Rev.Date-00/10-09-13

Receiving of Raw Material Receiving of Raw Material


Cu 6.35 *T 0.7 mm(C1220T-O) Capill OD 4.76*Th-0.7 mm(C1220T-O)

IQC IQC
Reject
Not OK Not OK
OK Ok

Cutting Cutting

PQC PQC
Reject
Not OK Not OK
OK Ok

De Burring De Burring

Air Blowing
Air Blowing

PQC PQC
Reject Not ok
Not Ok
OK Ok

Bending Expanding

Gauging
PQC

Not Ok Reject Not Ok Ok


OK PQC

Bending

Reject Not Ok PQC

Ok
Cleaning & N2 Blowing

PQC
PROCESS FLOW DIAGRAM Doc.No.QMS-F-15
Auxiliary inlet pipe assy (3P357458-1) Rev.Date-00/10-09-13
To(A)

TO (A) TO (B)
Dimple

Final Fitment
PQC

Not ok
Ok PQC
Reject
Brazing
Ok No
(Reducer+Capill+Distributor+Cu Not OK
tube OK
D)

N2 Blowing & End


Capping /Packing
PQC
Reject
Not ok

OK

Leakage Test OQC


O
Reject
Not OK
Not OK
OK
OK
Chock Testing
QC Certify & Despatch

Gauging

PQC Not ok Reject

LEGEND: To (B)
IQC : INCOMING QUALTIY CONTROL
PQC: PROCESS QUALTIY CONTROL
OQC: OUTGOING QUALTIY CONTROL

REV.NO DATE AMENDMENTS

PREPARED BY CHECKED BY APPROVED BY


PROCESS FLOW DIAGRAM Doc.No.QMS-F-15
Capillary tube assy (4PN16086-1) Rev.Date-00/10-09-13

Receiving of Raw Material Receiving of Raw Material


Cu 6.35 *T 0.7 mm(C1220TS-O) Capill OD 3.3*ID-2.2 mm(C1220T-O)

IQC IQC
Reject
Not OK Not OK
OK Ok

Cutting Cutting

PQC PQC
Reject
Not OK Not OK
OK Ok

De Burring De Burring

Air Blowing
Air Blowing

PQC PQC
Reject
Not Ok
OK Not ok Ok

Reducing
Beading

Ok
Not Ok PQC
PQC Reject
Not Ok
OK
Blockage
Not Ok Testing
Reject

Ok
Bending

Not Ok PQC
Reject
PROCESS FLOW DIAGRAM Doc.No.QMS-F-15
Capillary TubeCleaning
Assy &(4PN16086-1)
N2 Blowing Rev.Date-00/10-09-13

PQC
TO (A) TO (B)

Brazing
Final Fitment
(Reducer+Capill)

Contamination testing
PQC 25mg/m²
Reject

Ok Not ok Not OK
OK

Blockage Testing
N2 Blowing & End
Reject Capping /Packing
Not OK
OK

Leakage Test
OK

OQC
O
Gauging Reject
Not OK
Ok
PQC Not OK
OK

QC Certify & Despatch


Capillary flow testing
11L/min

PQC Not ok Reject


Ok

Ok To (B)

LEGEND:
IQC : INCOMING QUALTIY CONTROL
PQC: PROCESS QUALTIY CONTROL
OQC: OUTGOING QUALTIY CONTROL

REV.NO DATE AMENDMENTS


PREPARED BY CHECKED BY APPROVED BY

You might also like