Doosan Power Systems India Pvt. Ltd.

18/2A, Senneerkuppam, By pass Road.,


Poonamallee, Chennai-600 056
T : 91-44-6645-5555
F : 91-44-6545-5500~1

NTPC Ref. No. : CC:PE:9548:102:4108 / Date : 06 Mar, 2014


SUPPLIER'S REPLY SHEETS
Doosan Ref. No. : LR-R-DS/NT-0426 / Date : 11 Apr, 2014
NTPC Doc No. : 9548-102-PVM-L-002 / Rev. 03 / CAT : II
DOC / DWG TITLE : P&I DIAGRAM ECONOMIZER SYSTEM
Doosan Doc No. : DT12007-PI-D7205 / Rev. D
ITEM COMMENTS DOOSAN's REPLY REMARKS
1 Doosan to clarify about the flow value shown in the below The spray water flow for SH has been extracted before ECO. Inlet.
table.Why the cumulative flow of point 2 and 3 is not 2550 T/hr??? This flow parameter is indicated on DWG 'CAGE & PRIMARY
SUPERHEATER'_(9548-102-PVM-L-006), Pamrameter No. 3

2 Doosan to match the line with respective vendor's line. This Comment is not related to P&ID. This issue is already discuessed
with NTPC during 4th TCM.

3 295.4 as per Interface MOM. Noted.

4 Doosan to clearly define in notes that the parameters mentioned Revised.


here are operating parameters or design parameters.

1 of 1