INSTRUMENT FORM

Maintenance Dept. - Instrument Section

Form Type Project Shut Down Maintenance


DISMANTLE MO Number
& Work Package
RE-INSTALL Area

Tag No. : Manufacture :


Equipment Type : Serial Number :
Service : Type / Part No. :

No. Description Finish Remark

DISMANTLE
Power position off
1
Power dalam posisi "non-aktif"
Cable Terminal, stanchion, and process conestion is marked
2
Kabel terminal, tiang, dan proses koneksi diberi tanda
Add label for switch status (No/NC)
3
Beri tanda status switch (NO/NC)
Use the proper tools
4
Gunakan peralatan yang sesuai
Isolate line close black to switch
5

RE-INSTALL
Cable is connected to verify connection
1
Hubungkan kabel ke terminal yang bersesuaian
Remove label and handle the waste
2
Lepas label dan buang pada tempatnya
Tighten connection, bolt, and nuts
3
Kencangkan sambungan, mur, dan baut
Normalizer line
4
Normalisasi line
Open Valve to switch
5
Buka Valve ke switch
Painting cover switch
6
Cat pelindung switch
Tagging Metal name plate
7
Pasang tanda plat nama dari metal
Calibration sticker AKTI
8
Beri stiker kalibrasi AKTI

Note :

Dismantled By, Re-installed By, Approved By,

Name Name Name


Date Date Date
Form No. :
AKTI Job Code :
PT. ASAHI KOKUSAI TECHNEION INDONESIA
Report No. :
Sheet No :
FLOW TRANSMITTER CALIBRATION REPORT

1. INSTRUMENT DATA
1. TAG No.: : 9. CALIBRATION INFORMATION:
2. MFR./MODEL : MAKER SERIAL NO. EQUIPMENT NAME
SUFFIX :
3. TYPE :
4. SERIAL NO. :
5. SERVICE :
6. CAL. RANGE :
7. OUTPUT SIGNAL :
8. CALIB. DATE : WEATHER : ROOM TEMP : o
C

2. CALIBRATION DATA
Input Unit :
Output Unit :
Accuracy % F.S :

INPUT OUTPUT (TRANSMITTER)


REMARKS
TEST LIQUID PRESSURE TEMP. FLOWRATE FLOWRATE mA

REMARKS

3. NOTES
PT. ASAHI KOKUSAI TECHNEION INDONESIA CLIENT :
Calibrated by: Checked by : APPROVED

Name : Name : Name :

file:///conversion/tmp/activity_task_scratch/566369063.xlsx
SHUTDOWN PT. CABOT 2021
PHOTO REPORT

Tag No :

Before
SHUTDOWN PT. CABOT 2021
PHOTO REPORT

Tag No :

Before
SHUTDOWN PT. CABOT 2021
PHOTO REPORT

Tag No :

AFTER
Form No. :
AKTI Job Code :
Report No. :
Sheet No. :
DP TRANSMITTER CALIBRATION REPORT
ept. - Instrument Section
1. INSTRUMENT DATA
1. TAG No.: : 9. CALIBRATION INFORMATION:
2. MFR./MODEL : MAKER SERIAL NO. EQUIPMENT NAME
SUFFIX :
3. TYPE :
4. SERIAL NO. :
5. SERVICE :
6. CAL. RANGE :
7. OUTPUT SIGNAL :
8. CALIB. DATE : WEATHER : ROOM TEMP : C
o

2. CALIBRATION DATA
Input Unit : Pa / kPa / Bar / atm / mmHg / mmH2O / Kgf/cm 2 / Lbf/in2 / dyn/cm2 / mA / mV / Abs/ mm
Output Unit : A / mA / volt / mVolt / Hz
Accuracy % F.S :

BEFORE ADJUSTMENT

Calibration point Input Value Output Indication


Remarks
% mmH2O / Kgf/cm / Bar / kPa
2
mA value (STD) Reading value (mA) % Error

0 4.00

25 8.00

50 12.00

75 16.00

100 20.00

75 16.00

50 12.00

25 8.00

0 4.00

AFTER ADJUSTMENT

Calibration point Input Value Output Indication


Remarks
% mmH2O / Kgf/cm2 / Bar / kPa mA value (STD) Reading value (mA) % Error

0 4.00

25 8.00

50 12.00

75 16.00

100 20.00

75 16.00

50 12.00

25 8.00

0 4.00

3. Notes
PT.ASAHI KOKUSAI TECHNEION INDONESIA CLIENT :
Calibrated by: Checked by : (QA.QC) APPROVED

Name : Name : Name :