Professional Documents
Culture Documents
Precision Heavy-Duty
640 SERIES
• Vacuum ranges through 0 psig to 15,000 psig; absolute ranges from
0 psia to 15 psia through 0 psia to 300 psia
• Standard 4 mA to 20 mA output
• 316 and 17-4PH Stainless Steel wetted parts
• CE compliant to suppress RFI, EMI and ESD
SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire
Pressure ranges Vacuum through 0 psig to 15,000 psig
Absolute from 0 to 15 psia through 0 psia to 300 psia
Accuracy ±0.05% full scale (BFSL); optional ±0.025% full scale (BFSL); (includes the ef-
fects of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Stability ≤ ±0.1% full scale; 5 psi ±0.2% full scale per year
Response time < 300 ms (between 10% to 90% full scale)
Service life > 100,000,000 load cycles
Temperature ranges Compensated 32 °F to 160 °F (0 °C to 70 °C)
Effect: ±0.005% °F (32 °F to 50 °F) to zero point and pressure range no effect
(50 °F to 104 °F) for zero and span
±0.005%/ °F (104 °F to 158 °F) to zero point and pressure range
APPLICATIONS Media - 5 °F to 160 °F (-20 °C to 70 °C)
■ Aerospace equipment Ambient 32 °F to 160 °F (0 °C to 70 °C)
Storage -5 °F to 160 °F (-20 °C to 70 °C)
■ Laboratory & test equipment Power requirement* 9 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire, 0 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
■ Precision measurement Voltage supply via RS232 interface (RS232)
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Proof pressure 3 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
2 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi
Burst pressure 4 times full scale for ranges 0 psi to 5 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi
Measuring element 316 Stainless Steel for vacuum through 300 psi;
17-4PH Stainless Steel for ≥500 psi
Connection 316 Stainless Steel
Housing material 316 Stainless Steel
Environmental rating IP65
Electromagnetic rating CE compliant to EMC norm EN 61326:2014/A1:1998
RFI, EMI and ESD protection
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock 100 g’s according to IEC 60068-2-27
Vibration 15 g’s according to IEC 60068-2-6
Weight Approximately 11 oz.
* Unregulated
WARNING: This product can expose you to chemicals including Nickel, which is known to the State of California to cause
74 cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
640 SERIES ORDERING
INFORMATION
DIMENSIONS
ORDERING INFORMATION
SERIES 640
PRESSURE 30vac -30 inHg to 0 psig 30/300 -30 inHg to 300 psig 150 0 psig to 150 psig 3000 0 psig to 3,000 psig 30A 0 psia to 30 psia
RANGES 30/15 -30 inHg to 15 psig 5 0 psig to 5 psig 200 0 psig to 200 psig 5000 0 psig to 5,000 psig 60A 0 psia to 60 psia
30/30 -30 inHg to 30 psig 10 0 psig to 10 psig 300 0 psig to 300 psig 6000 0 psig to 6,000 psig 100A 0 psia to 100 psia
30/60 -30 inHg to 60 psig 15 0 psig to 15 psig 500 0 psig to 500 psig 7500 0 psia to 7,500 psig 150A 0 psia to 150 psia
30/100 -30 inHg to 100 psig 30 0 psig to 30 psig 750 0 psig to 750 psig 10000 0 psia to 10,000 psig 200A 0 psia to 200 psia
30/150 -30 inHg to 150 psig 60 0 psig to 60 psig 1000 0 psig to 1,000 psig 15000 0 psia to 15,000 psig 300A 0 psia to 300 psia
30/200 -30 inHg to 200 psig 100 0 psig to 100 psig 2000 0 psig to 2,000 psig 15A 0 psia to 15 psia
psig = gauge pressure psia = absolute pressure Other ranges available on request
ACCURACIES 1 ±0.05% full scale (BFSL) 2 ±0.025% full scale (BFSL)
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire analog 5 0 Vdc to 10 Vdc, 3-wire analog
2 0 Vdc to 5 Vdc, 3-wire analog
PROCESS CONNECTIONS 2 1/4″ NPT male 8 1/2″ NPT male; other connections available upon request
ELECTRICAL CONNECTIONS 1 54″ Integral cable 25 M12 x 1 (4-pin)
OPTION ST8 Threaded Orifice
Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.
2.95"
(75 mm)
1.06" HEX
(27 mm) 0.51" (13 mm)
1/4" NPT
1.06"
(27 mm)
3-WIRE WIRING
2-WIRE WIRING Wiring M12 Cable
Wiring M12 Cable + Supply 1 Brown
+ Supply 1 Brown Common 3 Blue
+ Output 3 Blue + Output 4 Black
75
A4A Precision Pressure Gauge
FEATURES SPECIFICATIONS
• ±0.1% F.S. accuracy – ASME B40.1, Accuracy: ±0.1% of Span
Grade 4A Includes Calibration Certificate Traceable to NIST.
Meets requirements of MIL-STD-45662 and
• Ranges from 15-100,000 psi ASME B40.1 Grade 4A
• Solid front protective case Repeatability: ±0.02% of Span
• High and low pressure limit stops Hysteresis: <0.1% of Span (1)
• Mirror band dial to eliminate parallax Sensitivity: 0.01% of Span
reading error Pressure Ranges: 0/15 psi through 0/100,000 psi
• Optional temperature compensation ˝Unitized˝ Bourdon Tube Materials
maintains 0.1% accuracy from Pressure Ranges:
Beryllium Copper 0/15 psi thru 0/40 psi
–25 to +125°F
403 SS 0/50 psi thru 0/100,000 psi
Standard Pressure Inlet Type & Location:
1
The Ashcroft precision pressure gauge ⁄4 NPT Female – Back Connect
0/15 psi thru 0/10,000 psi
yields consistent, reliable accuracy 9
⁄16-18 UNF-2B Female –
through the use of state-of-the-art preci- Back Connect Over 10,000 through 100,000 psi
sion machining and the world’s most White Dial, Knife-Edge Pointer, Mirror Ring:
refined bourdon tube technology. This Available Dial Sizes 6˝ 8.5˝ 12˝ 16˝
eliminates the need for a power source Scale Length 18˝ 25˝ 31.5˝ 43.25˝
Pointer Travel 350°*
and precludes the associated problems
*Ranges over 30,000 psi have less travel
such as susceptibility to electronic line
noise, power outage or potential fire haz- OPTIONAL FEATURES
˝Unitized˝ Bourdon Tube Materials/Pressure Ranges:
ard. In addition, this mechanical instru-
Beryllium Copper 0/50 psi through 0/10,000 psi
ment is simple to operate, easy to trouble- 403 0/15 psi through 0/40 psi
shoot, and can be readily flushed or Optional Pressure Inlet Type and Location:
purged to remove foreign matter or (Specify type and location)
1
trapped gas. Accurate and reliable, the ⁄4 NPT Female Bottom
1
Ashcroft A4A sets a new standard for ⁄8 NPT Male or Female–Back or Bottom
1
⁄4 NPT Male or Female–Back or Bottom
precision test gauges. 9
⁄16-18 UNF-2B Female for 1⁄4˝ HP Tubing
MS33649-4 Female Only–Back or Bottom
MS33656-4 Male Only–Back or Bottom
MS-16142 Female Only–Back or Bottom
Mil-G-18997D Male Only–Back or Bottom
Dual Scale: For example, psi & inches of mercury or
inches of water & kPa
Optional Pressure Types: Absolute, Vacuum,
Compound(2)
Bimetallic Temperature Compensator: Eliminates
temperature errors from –25°F to +125°F(3)
Other Engineering Units/Special Scales: For
example, tons on ram
Slotted Link: Protects gauge from damage due to
sudden pressure release
Peak Load Indicator: Tracks the maximum indicated
pressure measurement
Wall Mounting Brackets: Provides simplified wall
mounted installation
(1) Hysteresis may exceed ±0.1% of span for ranges equal to
or greater than 75,000 psi. (±0.3% typical not to exceed
± 0.4% of span).
(2) Absolute gauges require manual settings of barometric
pressure
(3) Recommended for precision applications where ambient
temperature varies more than ±10°F
All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
BULLETIN A4A-1 © 2016 Ashcroft Inc. 01/16 email: info@ashcroft.com • www.ashcroft .com
A4A Precision Pressure Gauge
All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
BULLETIN A4A-1 © 2016 Ashcroft Inc. 01/16 email: info@ashcroft.com • www.ashcroft .com
A4A Precision Pressure Gauge
DIMENSION DRAWINGS
Dim.
Size Units A B C D E E1 E2 FM FF G HM HF J K L
in. 77⁄8 7 61⁄2 7 2 17⁄8 11⁄4 49⁄16 41⁄4 31⁄4 13⁄8 11⁄16 327⁄32 5
⁄8 215⁄32
6˝
mm 200 177.8 165.1 177.8 50.8 47.6 31.8 115.8 107.9 82.3 34.9 27 97.6 15.9 62.7
in. 105⁄16 93⁄8 815⁄16 91⁄2 2 17⁄8 11⁄4 543⁄64 523⁄64 31⁄4 13⁄8 11⁄16 41⁄32 5
⁄8 221⁄32
81⁄2˝
mm 261.9 238.1 228.6 241.3 50.8 47.6 31.8 144 136.1 82.3 34.9 27 102.4 15.9 67.4
in. 1321⁄32 123⁄4 123⁄8 91⁄2 2 17⁄8 11⁄4 543⁄64 523⁄64 31⁄4 13⁄8 11⁄16 41⁄32 5
⁄8 221⁄32
12˝
mm 346.9 329.9 314.3 241.3 50.8 47.6 31.8 144 136.1 82.3 34.9 27 102.4 15.9 67.4
in. 1723⁄32 163⁄4 163⁄8 91⁄2 31⁄4 15⁄16 163⁄64 59⁄16 51⁄4 325⁄64 13⁄8 11⁄16 41⁄16 41⁄64 221⁄32
16˝
mm 450.1 425.2 415.9 241.3 82.6 33.3 50.4 141.3 133.4 86.1 35.0 27.0 103.1 16.3 67.4
Inlet Pressure Pressure connection is illustrated in both back and bottom configurations.
Connection* P See page 4 for available fitting types.
Dial Size 6˝ 81⁄2˝ 12˝ 16˝
Approximate Net Weight 41⁄2 lbs. 73⁄4 lbs. 103⁄4 lbs. 141⁄4 lbs.
Weight
Shipping Weight 7 lbs. 10 lbs. 15 lbs. 21 lbs.
*Standard Inlet Fittings: 1⁄4 NPT Female Back Connection for ranges up to and including 10,000 psi.
AMINCO 45-11310 or AUTOCLAVE F-250-C for ranges over 10,000 psi.
All specifications are subject to change without notice. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
All sales subject to standard terms and conditions. Tel: 203-378-8281 • Fax: 203-385-0408
BULLETIN A4A-1 © 2016 Ashcroft Inc. 01/16 email: info@ashcroft.com • www.ashcroft .com
Heavy Duty, All Stainless Steel Gauges
2½” Model - 20S (20SV) ¼“NPT (SV = VIBRAGAUGE® option)
4” Models - 40S (40SV) ¼“NPT & 41S (41SV) ½”NPT
6” Models - 60S (60SV) ¼”NPT & 61S (61SV) ½”NPT
Dry, Liquid Fillable or Pre-Filled. VIBRAGAUGE® Option also available.
VIBRAGAUGE® for Dampening of vibration & pulsation without liquid filling.
- Case pressure-relief grommet (Topside on liguid-fillable models, Backside on dry models).
- White-painted aluminium dial, Black-printed figures.
- Black-anodised aluminium pointer (Micrometer adjustable is standard on 4” & 6” dial sizes).
- AISI 316 Stainless Socket & Element.
- AISI 316 Stainless Steel Case & Bayonet Ring (standard).
- IP CLASS = IP66. Operating temperature range = -4°F to 140°F (-20° to 60°C) without loss of accuracy.
- Orifice Restrictor Screw (standard Ø0.9mm, Ø0.4mm on request).
LENS
Laminated Safety Glass, removable / replaceable - 4mm (0.16” thick)
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.
20S2016111-V2 Engineering modifications may take place without prior notice.
Heavy Duty, All Stainless Steel Gauges
2½” Model - 20S (20SV) ¼“NPT (SV = VIBRAGAUGE® option)
4” Models - 40S (40SV) ¼“NPT & 41S (41SV) ½”NPT (or Non-Fillable Case = 44S & 44SV or 45S & 45SV)
6” Models - 60S (60SV) ¼”NPT & 61S (61SV) ½”NPT (or Non-Fillable Case = 62S & 62SV or 63S & 63SV)
Rear Flange Wall Mounting (R) Direct Mounting (Standard. no code)
Front Flange Panel Mounting (FP) & (LB) Clamp Fixing Panel Mounting (C)
Gas & Steam in excess of 400 psi (25 bar) pressure can represent danger if there is a rupture in the Bourdon Tube measuring this gas.
To minimize the danger, gauges in this application should be Solid Front type, having solid front between Bourdon tube & dial, safety window & blow-out back
to allow any discharge to release to the rear of the gauge.
Athough there is not necessarily any great risk in the use of gauges for gases at pressure less than 400psi (25 bar), a blow-out valve should be incorporated
& the purchaser should have regard to the nature of the gas & the installation conditions &, if necessary, order a gauge of the Solid Front type.
The essence of this type of gauge is safety.
(Surface mounted rear flange gauges of the “Solid Front Type Case” should be fitted with distance pieces of not less that 3/4” (20mm) long to allow them to be mounted away from wall or panel)
VIBRAGAUGE® dampened movement option provides twice the life of dry gauges, without liquid filling. Eliminates pointer flutter & liquid fill lines.
Before use please consult our recommendations regarding selection & installation or consult ASME B40.100.
STEWARTS - USA
6786 Tipperary
HOUSTON, TX 77061 USA
Phone: 713-643-1022
Fax: 713-643-2855
Toll Free: 1-800-901-1316
Web: stewartsusa.com
16 Reguladores de presión serie K
Dimensiones
Las dimensiones, en milímetros (pulgadas), son como referencia únicamente y susceptibles de cambio.
Máx. espesor del panel, 10,0 (0,39)
con 2 tuercas de bloqueo
Máx. espesor del panel, 16,0 (0,63)
con 1 tuerca de bloqueo
Orificio en panel, 35,0 (1,38) de diá.
19,0
(0,75)
Información de pedido
Construya la referencia del regulador serie KPP combinando los indicadores en la secuencia que se muestra a continuación.
4 5 6 7 8 9 10 11 12 13 14 15 16
KPP 1 L W A 4 2 2 P 2 0 0 0 0
4 Material del cuerpo 7 Configuración de puertas 12 Mando, Montaje
1 = Acero inoxidable 316 A, B, C, E, F, H, K, L, M, N 2 = Redondo
A = Acero inoxidable 316 con limpieza Consulte Configuraciones de puertas, en 3 =Tuerca antisabotaje de acero
según ASTM G93 Nivel E la página 52. inoxidable 316
6 = Redondo, para montaje en panel
5 Rango de control de presión 8 Puertas 7 =Tuerca antisabotaje de acero
L = 0 a 68,9 bar (0 a 1000 psig) 4 = 1/4 pulg NPT hembra inoxidable 316 para montaje en panel
M = 0 a 103 bar (0 a 1500 psig) Para opciones de colores de los mandos
N = 0 a 137 bar (0 a 2000 psig) 9 Asiento, Materiales de las juntas redondos, vea la página 56.
P = 0 a 206 bar (0 a 3000 psig)➀ 2 = PEEK, PTFE
R = 0 a 248 bar (0 a 3600 psig)➀ 13 Válvulas de aislamiento
10 Coeficiente de caudal (Cv) 0 = Sin válvulas
➀ No disponible con máxima presión de entrada de
137 bar (2000 psig). 1 = 0,02 Para las opciones de válvulas de aislamiento,
2 = 0,06 consulte la página 54
6 Máxima presión de entrada➀
N = 137 bar (2000 psig) 11 Mecanismo sensor, Venteo 14 Conexiones de botella
S = 275 bar (4000 psig) P =Pistón de acero inoxidable 316, 0 = Sin conexiones
W = 413 bar (6000 psig) sin venteo
➀ Para mejorar la resolución y el control, seleccione V =Pistón de acero inoxidable 316, 15 Manómetros
la presión de entrada más próxima a la presión del venteo conducido, sin auto venteo 0 = Sin manómetros
sistema.
Para las opciones de manómetros en
la entrada y en la salida, consulte la
página 54.
16 Opciones
0 = Sin opciones
XFC Series - Filtro Regulador + Lubricador
Unidades de 2 piezas, para ser usadas donde el espacio disponible no permite la instalación de las
unidades de 3 piezas, en esta unidad están integrados en una sola pieza filtro y regulador, pueden ser
separadas la piezas, fácil de operar, fácil de montar y desmontar, eliminando las partículas sólidas
y condensados del aire comprimido, regulando la presión deseada de trabajo y proporcionando el
volumen adecuado de lubricación en los equipos que se requiera ya que puede regularse este volumen
en el lubricador, el vaso del filtro fabricado en policarbonato está protegido con un vaso metálico, su
drene puede ser manual o automático. Además, puede ser instalado en línea o modular.
Cómo Ordenar
Diagrama gráfico
Serie Conexión Tipo de Purga Manómetro Tamaño
XFC 15 D G MIDI
06 - 1/8" En Blanco: G: Con manómetro MINI
08 - 1/4" Manual En banco: Sin manómetro MIDI
10 - 3/8" MAXI
15 - 1/2"
20 - 3/4" Con Marca:
XFC-SERIES 25 - 1" D : Automática
X SERIES
Diagrama de flujo
XFC-08-MINI XFC-15-MIDI XFC-25-MAXI
44
XFC Series - Filtro Regulador + Lubricador
X SERIES
Dimensiones de las figuras
Dimensiones en mm
XF-SERIES XF-SERIES1
Modelo Conexión B1 B2 B3 B4 B5 B6 B7 D1 D2 D3 D4 D5 D6 D7 H1 H2 H3 H4 H5 L1 L2 L3 T1
XL-06-
1/8" 104 92 40 96 77 39 2 1/8" 31 M36X1.5 M4 4.3 39 38 20 43 35 11 17.5 194 1 69 7
MINI
XL-08-
1/4" 104 92 40 96 77 39 2 1/4" 31 M36X1.5 M4 4.3 39 38 20 43 35 11 17.5 194 1 69 7
MINI
XL-10-
3/8" 110 125 55 113 94 47 3 3/8" 50 M52X1.5 M5 5.3 51 52 32 70 60 22 24.5 250 2 98 8
MIDI
XL-15-
1/2" 140 125 55 113 94 47 3 1/2" 50 M52X1.6 M5 5.3 51 52 32 70 60 22 24.5 250 2 98 8
MIDI
XL-20-
3/4" 162 146 66 125 105 53 3 3/4" 31 M36X1.5 M5 5.3 62 62 32 70 60 22 24.5 252 2 80 11
MAXI
XL-25-
1" 182 157 66 125 105 53 3 1" 31 M36X1.5 M5 5.3 62 62 40 70 60 22 24.5 252 2 80 11
MAXI
» www.dewitneumatica.mx
» contacto@dewitneumatica.mx 45
Valvulas Solenoide
Línea de productos GNC
D i s p e n s e r / In d iv id u a l
2094 2094LP3R
2 vías, Normalmente Cerrada. 2 vías, Normalmente Cerrada.
Acción Servo-operada. Válvula de retención incorporada.
Cuerpo: Latón. Cuerpo: Aluminio. Pistón y Asientos: PEEK.
Pistón y Asientos: Acero Inoxidable-Delrin. Conexiones: SAE 6 (UNF 9/16”-18)
Conexiónes:1/4”, 3/8” y 1/2” NPT. Presión: 10 a 350 bar. (145 a 5000 Psi).
Presión: 10 a 250 bar. Factor de Flujo:
(145 a 3700 Psi). Sin valvula de retención: 0.99 Kv (1.16 Cv).
Factor de flujo: 1.5 Kv (1.76 Cv)
2094LP3 Con valvula de retención: 0.89 Kv (1.04 Cv).
Tensiones: 50Hz: 24, 110 y 220 V. Sin Válvula de retención Tensiones: 50Hz: 24, 110 y 220 V.
60Hz: 24, 110, 120, 220 y 240 V. 60Hz: 24, 110, 120, 220 y 240 V.
Opcionales: Opcionales: Válvula de gran Caudal.
D i s pe n s e r / M a n if o ld
2094LP3-12 2094LP3-21/31
Normalmente Cerrada. Normalmente Cerrada.
Válvulas de retención incorporadas. Válvulas de retención incorporadas.
1 Entrada 2 Salidas. 3 Entradas 1 Salida.
Cuerpo: Aluminio. 3 etapas de Dispensers para Baja,
Pistón y Asientos: PEEK. Media y Alta presión.
Conexiones: SAE 6 (UNF 9/16”-18) Cuerpo: Aluminio.
Presión: 10 a 350 bar. Pistón y Asientos: PEEK.
(145 a 5000 Psi). Conexiones: SAE 6 (UNF 9/16”-18)
Factor de Flujo: 0.94 Kv (1.1 Cv) Presión: 10 a 350 bar.
Tensiones: 50Hz: 24, 110 y 220 V. (145 a 5000 Psi).
60Hz: 24, 110, 120, 220 y 240 V. Factor de Flujo: 0.94 Kv (1.1 Cv)
Opcional: Tensiones: 50Hz: 24, 110 y 220 V.
Construcciones especiales. 60Hz: 24, 110, 120, 220 y 240 V.
2094LP3-31
Hasta 350 bar (5000 Psi) 3 Etapas, Dispensers 1 Hasta 350 bar (5000 Psi)
1- Baja presión 2
Opcional: 2- Media presión Opcional:
3
1 Entrada 2 Salidas CARCASA A PRUEBA DE EXPLOSIÓN E INTEMPERIE 3- Alta presión CARCASA A PRUEBA DE EXPLOSIÓN E INTEMPERIE
CARACTERÍSTICAS: • Menos conectores • Precisión dimensional • Áreas de aplicación versátiles • Ahorro de mano de obra • Alta productividad y facilidad de mantenimiento •
2099
NOrmalmente Cerrada. Acción directa.
Cuerpo: Latón o Aluminio. GNC
Conexiones:
Latón: 1/4” y 3/8” NPT
Aluminio: SAE 6 (UNF 9/16”-18) Manometro Motor
Asiento: Buna N
Presión: 10 a 200 bar.
(145 a 2900 Psi) Válvula Regulador
Factor de Flujo: 0.73 Kv (0.86 Cv) Solenoide
Features
● The Trunnion ball valve is featured by blowout-proof design with
cylindrical extensions at the top and bottom of the ball.
● The trunnion prevents the ball from shifting and permits the ball to
rotate on a vertical axis.
● Integral ball stem machined from single piece of bar stock eliminates
the backlash during handle actuation.
● Panel mounting nut is standard permitting valve to panel or actuator.
Factory Test
Every valve is factory tested with nitrogen gas at 68.9bar (1000psig) for leakage to a maximum allowable leak rate of 0.1 SCCM at seat.
Hydraulic shell test is optionally performed at 1.5 times the working pressure to a requirement of no detectable leakage with a liquid
leak detector.
CNG/NGV Certifications
VCT86 and VCT863 Series valve provides leak-tight integrity in both low and high pressure systems in CNG and NGV applications.
Valves with PAI seat and HNBR O-ring are compatible with CNG fluid.
2 2
1 1
4 9.1 9 8 4
8
7
9.1 9 8
7 6
6
7
5 3 6
5 3
17
17
14 13
15
16
20 19 18 10 13
11 15 14
10 20 19 18 16
12 10
21
Materials of Construction
VT86 / VCT86 Series VTH86 Series
Component 2-Way 3-Way 2-Way 3-Way
Grade/ASTM Specification
1. Handle Nylon with brass insert
2. Set screw SS316/A276
3. Stop pin (2-Way -2, 3-Way -1) Stainless steel 316
4. Panel nut SS316/A479 or A276
5. Body SS316/A479 or A276
6. Stem SS316/A479 or A276
7. Stem bearing PEEK
8. Stem O-rings (2) FKM O-ring (HNBR for VCT86/VCT863 Series) FKM O-ring
9. Stem support ring - PEEK
9.1. Stem backup rings (2) - PTFE/D1710, type 1
10. Trunnion ball SS316/A479 or A276
11. Trunnion ball back-up rings (2) Reinforced PTFE -
FKM O-ring(HNBR
12. Trunnion ball O-rings (2) -
for VCT86 series)
PCTFE, optional PTFE,PEEK
13. Seats (2) PEEK
(PAI for VCT86/VCT863 Series)
14. Seat carriers (2) SS316/A479 or A276
15. Seat springs (12) Alloy X-750/AMS 5542
16. Seat carrier guides (2) SS316/A479 or A276
17. Seat carrier back-up rings (4) Reinforced PTFE
18. Seat carrier O-rings (2) FKM O-ring (HNBR for VCT86/VCT863 Series) FKM O-ring
19. End connector seals (2) PTFE/D1710, type 1
20. End connectors (2) SS316/A479 or A276
21. Plug - -
SS316/A479 or A276 -
● Wetted components and lubricants are listed in BLUE.
● Lubricants: Molybdenum disulfide and fluorinated based.
Flow Rate
VT86 series Flow Data @21 ° C (70 ° F)
Pressure Drop to Atmosphere ( P) 3-Way 2-Way
in bar (psig) Cv 0.75 Cv 1 Cv 1.2 Cv 1.3 Cv 1.4 Cv 1.5 Cv 1.6
0.68 (10) 9.0(2.4) 12.1 (3.2) 14.3 (3.8) 15.5 (4.1) 17.8 (4.4) 17.8 (4.7) 19.3 (5.1)
Water
3.4 (50) 20.0 (5.3) 26.8 (7.1) 32.1 (8.5) 34.8 (9.2) 37.4 (9.9) 40.1 (10.6) 42.7 (11.3)
L/min (U.S.GPM)
6.8 (100) 28.3 (7.5) 37.8 (10.0) 45.4 (12.0) 49.2 (13.0) 53.0 (14.0) 56.7 (15.0) 60.5 (16.0)
0.68 (10) 226 (8.0) 311 (11.0) 396 (14.0) 424 (15.0) 453 (16.0) 481 (17.0) 509 (18.0)
Air
3.4 (50) 651 (23.0) 849 (30.0) 1019 (36.0) 1104 (39.0) 1189 (42.0) 1274 (45.0) 1359 (48.0)
std L/min (SCFM)
6.8 (100) 1132 (40.0) 1500 (53.0) 1812 (64.0) 1953 (69.0) 2095 (74.0) 2265 (80.0) 2406 (85.0)
VTH86 series Flow Data @21 ° C (70 ° F)
Pressure Drop to Atmosphere ( P) 3-Way 2-Way
in bar (psig) Cv 0.75 Cv 1 Cv 1.2 Cv 1.3 Cv 1.4 Cv 1.5 Cv 1.6
10.3 (150) 34.8 (9.2) 45.4 (12) 56.7 (15) 60.5 (16) 64.3 (17) 68.1 (18) 74.1 (19.6)
Water
41.3 (600) 69.1 (18) 94 (25) 109 (29) 121 (32) 128 (34) 140 (37) 147 (39)
L/min (U.S.GPM)
68.9 (1000) 90.8 (24) 143 (38) 143 (38) 155 (41) 166 (44) 178 (47) 189 (50)
10.3 (150) 1614 (57) 2152 (76) 2805 (92) 2803 (99) 3029 (107) 3256 (115) 3454 (122)
Air
41.3 (600) 5946 (210) 8070 (285) 9627 (340) 10 505 (371) 11 298 (399) 12 119 (428) 12 912 (456)
std L/min (SCFM)
68.9 (1000) 9912 (350) 13 308(470) 16 140 (570) 17 272 (610) 18 688 (660) 19 821 (700) 21 321 (750)
3
Trunnion Ball Valves VT86 Series
VT86 Series Pressure-Temperature Ratings VTH86 Series Pressure-Temperature Ratings
Body material 316 Stainless steel Body material 316 Stainless steel
Seat material PCTFE PTFE PEEK End DK-LOK 6M, 1/4 in. 8M, 3/8 in. 12M, 1/2 in. 10M
Temperature bar psig bar psig bar psig connection Female NPT 1/8, 1/4 in. - - -
°C °F Working Pressure Seat Material PEEK
-17 to 37 0 to 100 413 6000 103 1500 413 6000 Temperature Working Pressure
65 150 206 3000 77.5 1125 399 5800 °C °F bar psig bar psig bar psig bar psig
93 200 137 2000 51.6 750 344 5000 -17 to 37 0 to 100 689 10 000 516 7500 454 6600 413 6000
121 250 69 1000 43 625 282 4100 65 150 516 7500 516 7500 454 6600 406 5900
148 300 - - 34.4 500 220 3200 93 200 344 5000 344 5000 344 5000 344 5000
176 350 - - 25.8 375 158 2300 121 250 282 4100 282 4100 282 4100 282 4100
204 400 - - 17.2 250 96.4 1400 148 300 220 3200 220 3200 220 3200 220 3200
232 450 - - 8.6 125 34.4 500 176 350 158 2300 158 2300 158 2300 158 2300
204 400 96.4 1400 96.4 1400 96.4 1400 96.4 1400
232 450 34.4 500 34.4 500 34.4 500 34.4 500
Options
VT86 Series 2-Way Valve External Vent Options
A downstream or upstream vent option on VT86 Series 2-Way ball valve is available. The vent port is constructed on trunnion ball.
The vent port activates when the valve is in closed position. This option reduces the valve pressure rating to 34.4bar (500 psig).
Downstream Vent Upstream Vent
Ordering designator - DV Ordering designator - UV
When a downstream vent valve in closed position, When a upstream vent valve in closed position,
shutoff at the upstream seat occurs. Downstream shutoff at the downstream seat occurs. Upstream
system media flows into the vent hole and vents system media flows into the vent hole and vents
out to atmosphere through the valve bottom. out to atmosphere through the valve bottom.
DV UV
Service Kit
VCT863 Series Ball Valve
For field assembly, service kit with a maintenance instruction is available. Service kit Maintenance Instructions
MI-VCT863 R.0
contains wetted parts including trunnion ball, stem assembly and seat carrier assembly.
To order the service kit, prefix SK- to the valve series. i.e., SK-VCT863, SK-VTH863.
Select applicable valve basic ordering number, options and body material designator listed below.
VT86-D4T -PK -DV -S
VTH86-D12M -S
VCT86-F4M -S
General information
Product type designation CPU 1511C-1 PN
HW functional status FS03
Firmware version V2.8
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode Yes; With minimum OB 6x cycle of 625 µs (distributed)
Engineering with
● STEP 7 TIA Portal configurable/integrated as of V16 (FW V2.8) / V15 (FW V2.5) or higher; with older TIA Portal
version versions configurable as 6ES7511-1CK00-0AB0
Configuration control
via dataset Yes
Display
Screen diagonal [cm] 3.45 cm
Control elements
Number of keys 8
Mode buttons 2
Input current
Current consumption (rated value) 0.8 A; Without load; 9.8 A: CPU + load
Current consumption, max. 1 A; Without load; 10 A: CPU + load
Inrush current, max. 1.9 A; Rated value
I²t 0.34 A²·s
Digital inputs
● from load voltage L+ (without load), max. 20 mA; per group
Digital outputs
● from load voltage L+, max. 30 mA; Per group, without load
Output voltage
Rated value (DC) 24 V
Encoder supply
Number of outputs 1; One common 24 V encoder supply
24 V encoder supply
● 24 V Yes; L+ (-0.8 V)
● Short-circuit protection Yes
● Output current, max. 1 A
Power
Infeed power to the backplane bus 10 W
Power consumption from the backplane bus 8.5 W
(balanced)
Power loss
Power loss, typ. 11.8 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 175 kbyte
● integrated (for data) 1 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
CPU-blocks
Number of elements (total) 2 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range 1 ... 60 999; subdivided into: number range that can be used by
the user: 1 ... 59 999, and number range of DBs created via SFC
86: 60 000 ... 60 999
● Size, max. 1 Mbyte; For DBs with absolute addressing, the max. size is 64
KB
FB
● Number range 0 ... 65 535
● Size, max. 175 kbyte
FC
● Number range 0 ... 65 535
● Size, max. 175 kbyte
OB
● Size, max. 175 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 500 µs
● Number of process alarm OBs 50
● Number of DPV1 alarm OBs 3
● Number of isochronous mode OBs 1
● Number of technology synchronous alarm OBs 2
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24
Address area
Number of IO modules 1 024; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
per CM/CP
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Hardware configuration
Time of day
Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes
Digital inputs
integrated channels (DI) 16
Digital inputs, parameterizable Yes
Source/sink input P-reading
Input characteristic curve in accordance with IEC Yes
61131, type 3
Digital input functions, parameterizable
● Gate start/stop Yes
● Capture Yes
● Synchronization Yes
Input voltage
● Type of input voltage DC
● Rated value (DC) 24 V
● for signal "0" -3 to +5V
Digital outputs
Type of digital output Transistor
integrated channels (DO) 16
Current-sourcing Yes; Push-pull output
Short-circuit protection Yes; electronic/thermal
● Response threshold, typ. 1.6 A with standard output, 0.5 A with high-speed output; see
manual for details
Limitation of inductive shutdown voltage to -0.8 V
Controlling a digital input Yes
Accuracy of pulse duration Up to ±100 ppm ±2 μs at high-speed output; see manual for
details
minimum pulse duration 2 µs; With High Speed output
Digital output functions, parameterizable
● Switching tripped by comparison values Yes; As output signal of a high-speed counter
● PWM output Yes
— Number, max. 4
— Cycle duration, parameterizable Yes
— ON period, min. 0 %
— ON period, max. 100 %
— Resolution of the duty cycle 0.0036 %; For S7 analog format, min. 40 ns
● Frequency output Yes
Switching capacity of the outputs
● with resistive load, max. 0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed
output; see manual for details
Analog inputs
Number of analog inputs 5; 4x for U/I, 1x for R/RTD
● For current measurement 4; max.
● For voltage measurement 4; max.
● For resistance/resistance thermometer 1
measurement
permissible input voltage for voltage input 28.8 V
(destruction limit), max.
permissible input current for current input (destruction 40 mA
limit), max.
Cycle time (all channels), min. 1 ms; Dependent on the parameterized interference frequency
suppression; for details, see conversion procedure in manual
Technical unit for temperature measurement Yes; °C/°F/K
adjustable
Input ranges (rated values), voltages
● 0 to +10 V Yes; Physical measuring range: ± 10 V
— Input resistance (0 to 10 V) 100 kΩ
● 1 V to 5 V Yes; Physical measuring range: ± 10 V
— Input resistance (1 V to 5 V) 100 kΩ
● -10 V to +10 V Yes
— Input resistance (-10 V to +10 V) 100 kΩ
● -5 V to +5 V Yes; Physical measuring range: ± 10 V
— Input resistance (-5 V to +5 V) 100 kΩ
Input ranges (rated values), currents
● 0 to 20 mA Yes; Physical measuring range: ± 20 mA
— Input resistance (0 to 20 mA) 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
● -20 mA to +20 mA Yes
— Input resistance (-20 mA to +20 mA) 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
● 4 mA to 20 mA Yes; Physical measuring range: ± 20 mA
— Input resistance (4 mA to 20 mA) 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
Input ranges (rated values), resistance thermometer
● Ni 100 Yes; Standard/climate
— Input resistance (Ni 100) 10 MΩ
● Pt 100 Yes; Standard/climate
— Input resistance (Pt 100) 10 MΩ
Input ranges (rated values), resistors
● 0 to 150 ohms Yes; Physical measuring range: 0 ... 600 ohms
— Input resistance (0 to 150 ohms) 10 MΩ
● 0 to 300 ohms Yes; Physical measuring range: 0 ... 600 ohms
Analog outputs
integrated channels (AO) 2
Voltage output, short-circuit protection Yes
Cycle time (all channels), min. 1 ms; Dependent on the parameterized interference frequency
suppression; for details, see conversion procedure in manual
Output ranges, voltage
● 0 to 10 V Yes
● 1 V to 5 V Yes
● -10 V to +10 V Yes
Output ranges, current
● 0 to 20 mA Yes
● -20 mA to +20 mA Yes
● 4 mA to 20 mA Yes
Load impedance (in rated range of output)
● with voltage outputs, min. 1 kΩ
● with voltage outputs, capacitive load, max. 100 nF
● with current outputs, max. 500 Ω
● with current outputs, inductive load, max. 1 mH
Cable length
● shielded, max. 200 m
Encoder
Connection of signal encoders
● for voltage measurement Yes
● for current measurement as 4-wire transducer Yes
● for resistance measurement with two-wire Yes
connection
● for resistance measurement with three-wire Yes
connection
● for resistance measurement with four-wire Yes
connection
Connectable encoders
● 2-wire sensor Yes
— permissible quiescent current (2-wire 1.5 mA
sensor), max.
Encoder signals, incremental encoder (asymmetrical)
● Input voltage 24 V
● Input frequency, max. 100 kHz
● Counting frequency, max. 400 kHz; with quadruple evaluation
● Signal filter, parameterizable Yes
● Incremental encoder with A/B tracks, 90° phase Yes
offset
● Incremental encoder with A/B tracks, 90° phase Yes
offset and zero track
● Pulse encoder Yes
● Pulse encoder with direction Yes
● Pulse encoder with one impulse signal per Yes
count direction
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.1 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Crosstalk between the inputs, max. -60 dB
Repeat accuracy in steady state at 25 °C (relative to 0.05 %
input range), (+/-)
Output ripple (relative to output range, bandwidth 0 to 0.02 %
50 kHz), (+/-)
Linearity error (relative to output range), (+/-) 0.15 %
Temperature error (relative to output range), (+/-) 0.005 %/K
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface types
● Number of ports 2
● integrated switch Yes
● RJ 45 (Ethernet) Yes; X1
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes; Optionally also encrypted
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
Services
— PG/OP communication Yes
Interface types
RJ 45 (Ethernet)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
Protocols
Number of connections
● Number of connections, max. 96; via integrated interfaces of the CPU and connected CPs / CMs
● Number of connections reserved for 10
ES/HMI/web
● Number of connections via integrated 64
interfaces
● Number of S7 routing paths 16
Redundancy mode
● H-Sync forwarding Yes
Media redundancy
— Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max. 50
SIMATIC communication
● S7 communication, as server Yes
● S7 communication, as client Yes
● User data per job, max. See online help (S7 communication, user data size)
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, Yes
supported
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; Max. 5 multicast circuits
Isochronous mode
Equidistance Yes
S7 message functions
Number of login stations for message functions, max. 32
Program alarms Yes
Number of configurable program messages, max. 5 000; Program messages are generated by the "Program_Alarm"
block, ProDiag or GRAPH
Number of loadable program messages in RUN, 2 500
max.
Number of simultaneously active program alarms
● Number of program alarms 600
● Number of alarms for system diagnostics 100
● Number of alarms for motion technology 80
objects
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarm Yes
● Hardware interrupt Yes
Diagnostic messages
● Monitoring the supply voltage Yes
● Wire-break Yes; for analog inputs/outputs, see description in manual
● Short-circuit Yes; for analog outputs, see description in manual
● A/B transition error at incremental encoder Yes
Diagnostics indication LED
● RUN/STOP LED Yes
● ERROR LED Yes
● MAINT LED Yes
● STOP ACTIVE LED Yes
● Monitoring of the supply voltage (PWR-LED) Yes
● Channel status display Yes
● for channel diagnostics Yes; For analog inputs/outputs
● Connection display LINK TX/RX Yes
Integrated Functions
Number of counters 6; Of which max. 4x A/B/N
Counting frequency (counter) max. 400 kHz; with quadruple evaluation
Counting functions
● Continuous counting Yes
● Counter response parameterizable Yes
● Hardware gate via digital input Yes
● Software gate Yes
● Event-controlled stop Yes
● Synchronization via digital input Yes
● Counting range, parameterizable Yes
Comparator
— Number of comparators 2; per count channel; see manual for details
— Direction dependency Yes
— Can be changed from user program Yes
Position detection
● Incremental acquisition Yes
● Suitable for S7-1500 Motion Control Yes
Measuring functions
● Measuring time, parameterizable Yes
● Dynamic measurement period adjustment Yes
● Number of thresholds, parameterizable 2
Measuring range
— Frequency measurement, min. 0.04 Hz
— Frequency measurement, max. 400 kHz; with quadruple evaluation
— Cycle duration measurement, min. 2.5 µs
— Cycle duration measurement, max. 25 s
Accuracy
— Frequency measurement 100 ppm; depending on measuring interval and signal evaluation
— Cycle duration measurement 100 ppm; depending on measuring interval and signal evaluation
— Velocity measurement 100 ppm; depending on measuring interval and signal evaluation
Isolation
Isolation tested with 707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -25 °C; No condensation
● horizontal installation, max. 60 °C; Note derating data for onboard I/O in the manual. Display:
50 °C, at an operating temperature of typically 50 °C, the display
is switched off
● vertical installation, min. -25 °C; No condensation
● vertical installation, max. 40 °C; Note derating data for onboard I/O in the manual. Display:
40 °C, at an operating temperature of typically 40 °C, the display
is switched off
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see
manual
Configuration
Programming
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— GRAPH Yes
Know-how protection
● User program protection/password protection Yes
● Copy protection Yes
● Block protection Yes
Access protection
● Password for display Yes
Dimensions
Width 85 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 1 050 g
SIMATIC S7, Memory Card para S7-1x00 CPU, 3, 3 V Flash, 256 MBytes
Información general
Designación del tipo de producto Tarjeta de memoria
Memoria
Tipo de memoria Flash-EPROM
Flash Sí
Tamaño de memoria 256 Mbyte
Número de operaciones de borrado/escritura, mín. 200 000
Conservación de datos (tras última programación), mín. 10 y; si operaciones de borrado/escritura < 20 000 (1 a, si operaciones
de borrado/escritura > 180 000)
Dimensiones
Ancho 24 mm
Altura 32 mm
Profundidad 2,1 mm
Pesos
Peso, aprox. 3g
Dimensiones
Ancho 530 mm
Altura 155 mm
Profundidad 16 mm
Pesos
Peso, aprox. 1 034 g