This selection guide has been designed to allow quick and simple selection
for a broad range of TROX Grille and Diffuser product. Full product and system
details for these and other TROX equipment can be found on our website
www.troxuk.co.uk.
As part of our commitment to a collaborative design process our local Sales Engineers are
available to offer assistance and advice on these and other TROX systems and product. To
contact you local engineer call 01842 754545.
In addition to the Grille and Diffuser product in this guide, TROX offer a complete range of air
distribution products and systems, these include:
Chilled Ceilings
Acoustics
Filtration
Labcontrol
TROX UK Ltd
Caxton Way
Thetford
Norfolk IP24 3SQ
Tel: +44 (0) 1842 754545
Fax: +44 (0) 1842 763051
E-Mail: sales@troxuk.co.uk
www.troxuk.co.uk
Contents
Page
Section1 - Adjustable Grilles
AT/VAT 04
aerofoil blades. Front border 32mm wide with visible screw fixing
(border counter-punched). Available on request with concealed
fixing and sub frame.
Sizes Available
Minimum size 150 x 100. Maximum Size 1200 x 600. Standard
increments 50mm.
Order Code
H + 22/L + 22
H + 45/L + 45
...-D
16,7
H/L
...-DG
Volume control dampers as ...-AG plus a set of Type AT shown
75
control blades.
04
Performance Data
SECTION 1
Grille with ceiling effect (grille installed within 300mm of ceiling). Throw is the distance from sidewall grille to an average
velocity of 0.35 m/s. The minimum distance between multiple units must be 20% of Throw.
Adjustable Grilles
500 200 150
400
Throw Effective Jet Pressure
350 (m) Velocity drop (total)
(m/s) (Pa) 250
300
60
250 10 8 200
40
8 6
20 300
200 5
6 4
175 10
5 3 250
150 350
5
125 4
2
3 400
100 300
90
450
70 Pivot 350
line 500
400
50
600
40 450
700
30 500
800
600
20 900
1000
1200
Throw assumes direction blades set at 45° blade By limiting effective jet velocity to 7 m/s all grille sizes
divergence. For 0° blade divergence multiple throw by 1.4 shown meet NC35 assuming 8dB room attenuation and
and divide pressure drop by 1.1. fully open damper.
75
15
05
Eggcrate Grille Type AE
SECTION 2
Return air grille with fixed square pattern core. Front border 32mm
with visible screw fixing. Available on request with concealed
fixing.
Size Available
Minimum Size 150 x 100. Maximum Size 1200 x 600. Standard
increments 50mm.
Order Code
75
15
13
H/L
Rear Assembly
70
104
...-AG
06
Performance Data
SECTION 2
Nominal Pivot Nominal
width line height
(mm) (mm)
L H
100
200
Extract Grilles
Air Volume
150
(l/s)
300
1000
200
Effective Jet Pressure
Velocity drop (total)
(m/s) (Pa)
400
500
7 15 250
400 6
5 10
300 4 5 500
3 300
2
2
200
350
600
1
400
700 450
100 0.5
Pivot 500
800
line
900 600
50
1000
1100
25
1200
By limiting effective jet velocity to 7 m/s all grille sizes shown meet NC35 assuming 8 dB room attenuation (no damper or
damper fully open).
07
Computer Room Floor Grille Type CFG/AFG
SECTION 3
Floor grille types CFG and AFG are specifically developed for mounting in Raised
Access Floors in such areas as Computer Rooms, where load and damage resistance
are of the utmost importance.
Having a heavy duty construction, they can replace 600mm square floor tiles. Grille
border depth can be specified to suit the type of floor system used. A range of
surface finishes is available.
The type CFG is a fan assisted computer room floor grille that
eliminates hotspots and reduces risk of equipment failure by
providing up to 5kW of cooling per cabinet.
The type AFG is a static grille assembly which can handle supply air
Floor Grilles
Order Code
Type Size (mm) Frame Depth (mm) P2 = Polyester powder coat silver grey
CFG between face of grille RAL 9006 25% Gloss (Standard)
AFG and face of pedestal P4 = Polyester powder coat black
Rear Assembles Unit Depth (mm) 25 standard RAL 9006 20% Gloss
F1 = Fan Pack (230V Standard) CFG only 125 = Standard Optionally 26 - 50 in N1 = Polyester powder coat with nylon
A = Face only, AFG only *75 = Optional 1mm steps reinforcing black RAL 9005
AG = Rear opposed blade damper, AFG only 0 = Not used AFG
Detail A
X
68.5
140mm Approx
Shims to
suit height
required
(factory fitted)
08
SECTION 3
CFG Fan Specification CFG Acoustic Data
Watts/Motor 26 Sound power level for one CFG 76dB(A)
Total Watts 104 In an area with several units the noise level will increase
Amps/Motor 0.12 due to multiple sources. To allow for this and room
Total Amps 0.48 attenuation an assessment should be made by an acoustic
Motor 230V AC 50Hz engineer to ensure required room noise levels are achieved.
Selection Guide
The floor grille should be located at the front of the
I.T./Comms cabinet experiencing hot spot conditions the
cabinet should incorporate a perforated door. The floor
void static pressure must be considered in the selection
Floor Grilles
process (see Potential cooling below). Sufficient void air
(cooled by others) must be available to be drawn by the
grille at the specific point of need.
5.11kW
PSA MOB PF2 PS/SPU March 1992, with the following results: 5.00
4.00
kW Cooling Capacity
Test Result
3.00
Stability of deflection
(centre of grille):
2.00
4.5 kN static load through 25mm Deflection 23 hours after load
square indentor applied - 3mm
0.81kW
Deflection 24 hours after load 1.00
applied - 3mm
0.09mm permanent 0.00
deformation CFG AFG Grille
0.01mm permanent indentation (no fans)
Note: Based on 10k rise across I.T. equipment with
Impact load test: 1 Pascal floor void static pressure
500
Dynamic rolling load test:
Air Volume (l/s)
400
4.5 kN load 50 passes of wheel Did not collapse
3 kN load 50 passes of wheel 0.40mm Vertical permanent 300
deformation (max) 200
3 kN load 50 passes of wheel 0.20mm Horizontal permanent
deformation (max) 100
0
Safety load test -15 -10 -5 0 5 10 15
(centre of grille):
Floor Void Static Pressure (Pa)
13.5 kN load through 25mm square Did not collapse CFG: 4 fans AFG: no fans
indentor
09
Floor Grille Type FB
SECTION 3
Diffusers may be installed into a floor with either a pressurised void (no
plenum box) or duct connection to optional side entry plenum box.
Surface of diffuser, core and trim ring: Size (mm) 0 = Standard polyamide
Ash grey - similar to RAL 7037 1 150 (PA 6)
Black - similar to RAL 9005 2 200 V00 = Polyamide
(PA 6-V0)
A = Plenum box
Adjustable swirl element2) vertical V
directional control horizontal H SM = Dirt trap including adjustable volume control at rear
vertical - fixed VF3) SV = Dirt trap including adjustable volume control at face
K = Trim ring1)
1) For orders without trim ring a spacing ring is provided for technical performance reasons and to ensure correct height of grille core.
2) For orders without adjustable swirl element the direction of air discharge is vertical.
3) Only available for size 200.
1 Diffuser Core
4 2 Swirl element for adjustment
of air discharge direction
3 Trim Ring
5 4 Clamping Ring
5 Dirt Trap
6 Plenum Box
6
10
SECTION 3
Performance Data
Horizontal Discharge Vertical
Throw (m) Discharge
Size
0.3 m 0.9 m 1.2 m 1.5 m
Air Volume (l/s) min - max 10 - 16 15 - 25 18 - 30 - 10 - 30
150
Press Drop (Pa) min - max 8 - 20 18 - 50 28 - 70 - 5 - 35
Air Volume (l/s) min - max 16 - 27 21 - 35 25 - 41 30 - 50 10 - 50
200
Press Drop (Pa) min - max 8 - 20 13 - 35 18 - 50 28 - 70 5 - 50
Max noise level NC38 assuming 4dB room attenuation. Data for FBA diffusers and dirt trap, damper fully open no plenum
box. Horizontal discharge is Throw distance to terminal velocity of 0.15m/s (min vol) and 0.25m/s (max vol). A 600mm
clear zone (from centre of diffuser) is recommmended with vertical discharge.
Floor Grilles
Dimensions
Size ØD G E H1 H2 K1 K2 ØR1 ØR2 ØR3 ØR4 ØR5 c1 c2
150 98 50 160 125 71.5 200 198.5 149.5 138 137 150.1 150.3 21 22
200 123 48 200 150 84 250 248.8 199.5 188 187 200.1 200.3 21 22
ØR1
For installation in floor panels - min. 25mm thickness
21
ØR5
c1
ØR2 ØR2
2
1,5
Plenum box A
18 K1/K2 G
Trim ring K
24
ØR4
H2
4,5
H1
c2
ØD
70
ØR4-9,5
11
Linear Grille Types AH - WAP
SECTION 4
Supply or return air grille with fixed horizontal profiled blades. Type
AH - 5.5mm blades on 12.5mm pitch. WAP - 3mm blades on 12.5mm
pitch. Front border 30mm wide, blades with either 0° or 15°
deflection, Type AH-0 and AH-15 respectively, with visible screw
fixing (border counter punched). Available on request with
concealed fixing. Standard finish: Powder coated RAL9010 20%
gloss.
Type AF
Supply or return air grilles for lay in floor mounting with fixed
Linear Grilles
Sizes Available
Minimum Size 150 x 100. Maximum Size 1800 x 600. Standard
increments 50mm.
Order Code
Type L x H (mm)
AF Powder coat finish
AH
WAP Rear Assemblies
A = Grille Face only Subframe Fixing
AHR (20mm border)
AG = Rear opposed 0 = No subframe 0 = Without (screwfix)
WAPR (20mm border)
blade damper B30 = 75mm subframe bracket S11 = With (secret fix)
D = Rear adjustable (30mm borders) for finite grille X = Without flange
Blade deflection
blades B20 = as above but for 20mm drilling
15°
0° DG = Rear adjustable border grille
blades and damper L30 = 1800mm subframe (30mm
borders) for linear grille**
L20 = as above but for 20mm border grille
Note: ** = Also for use when S11 fix plenum box supplied
12.5
volume control damper,
107
H/L
AF-0
...-D
A set of individually
32
H/L
...-DG
Volume control dampers
AH-0 AH-15
75
WAP-0 WAP-15
as ...-AG plus a set of
107
individually adjustable
vertical air pattern
control blades.
12
Performance Data
SECTION 4
Linear grille (with aspect ratio >12 to 1) with ceiling effect (grille installed within 300mm of ceiling). Throw is the distance
from sidewall grille to an average velocity of 0.35 m/s.
Nominal
height
(mm) Type
H
Air Volume
(l/s.m)
Effective Jet Pressure
Velocity drop (total) 75 AH/AF
400 (m/s) (Pa)
350 60
Linear Grilles
300 L 7 40
75 WAP
Throw 6 30
250 (m) 100 AH/AF
5 20
15
20 4
200 10
15
175 3 7
10 100 WAP
150 2
5 1.5 150 AH/AF
125
Pivot line
100 2
150 WAP
80 200 AH/AF
70 1
60
200 WAP
250 AH/AF
50
300 AH/AF
40
250 WAP
30
300 WAP
75
15
‘X’
Screwdriver operation
Type B30 - 30mm border : X = 15 to locate fastener
Type B20 - 20mm border : X = 5 tongue behind subframe
13
SECTION 5
Size Available
Minimum Size 150 x 100. Maximum Size 1200 x 600. Standard
Transfer Grilles
increments 50mm.
Order Code
Type L x H (mm)
LVV 40
14
SECTION 5
Performance Data
AGS
Neck Pressure Drop (Pa) 3 7 12.5 19.5 28 38
Size Jet Velocity 1 1.5 2 2.5 3 3.5
150 x 150 Volume (l/s) 7 10 14 17 20 24
200 x 150 Volume (l/s) 9 14 19 24 28 33
200 x 200 Volume (l/s) 15 23 30 38 45 53
300 x 200 Volume (l/s) 24 35 47 59 71 82
300 x 300 Volume (l/s) 38 57 76 96 115 134
400 x 300 Volume (l/s) 52 78 104 130 156 182
450 x 300 Volume (l/s) 59 88 117 147 176 205
Transfer Grilles
450 x 450 Volume (l/s) 90 135 181 226 271 316
600 x 400 Volume (l/s) 110 164 219 274 329 384
500 x 500 Volume (l/s) 116 174 232 290 348 406
600 x 600 Volume (l/s) 171 256 341 426 512 597
800 x 600 Volume (l/s) 229 344 459 573 688 803
1000 x 600 Volume (l/s) 288 432 576 720 864 1008
1200 x 600 Volume (l/s) 347 520 694 867 1041 1214
By limiting effective jet velocity to 3 m/s all grille sizes shown meet NC35 assuming 8 dB room attenuation.
LCG / LVV40
Neck NC20 NC25 NC30 NC35
Size Volume l/s T∆Pa Volume (l/s) T∆Pa Volume (l/s) T∆Pa Volume (l/s) T∆Pa
150 x 150 45 15 55 23 65 30 80 45
200 x 150 55 15 70 21 80 30 100 40
200 x 200 74 15 86 19 105 27 120 35
300 x 200 100 12 120 18 145 24 170 32
300 x 300 140 11 170 16 200 20 240 29
400 x 300 175 10 210 15 250 20 300 26
450 x 300 200 10 235 14 285 20 340 25
450 x 450 285 9 325 13 380 17 470 24
600 x 400 310 9 380 12 450 16 550 22
500 x 500 325 8 390 12 485 16 560 21
600 x 600 435 8 530 11 640 15 750 20
Data is for composite unit of 2No. grilles and integral fireblock. NC levels based on 8dB room attenuation.
Intumescent
mastic by others
LVV40 intumescent
fireblock
H1+10/L1+10
H/L
H1/L1
H/L
min25
max44
15
SECTION 6
The direction of air discharge can be adapted on site (by others) to the required
room conditions.
Size Available
1 to 4 slot lengths available in increments of 150mm.
Slot Diffusers
16
SECTION 6
Performance Data
VSD50
Throw (m)
Number of Slots
3.0 m 4.5 m 6.0 m
Air Volume (l/s/m) min - max 20 - 55 20 - 70 20 - 80
1
Press Drop (Pa) max 22 36 47
Air Volume (l/s/m) min - max 40 - 80 40 - 100 40 - 115
2
Press Drop (Pa) max 14 22 29
Air Volume (l/s/m) min - max 60 - 100 60 - 120 60 - 145
3
Press Drop (Pa) max 10 15 20
Air Volume (l/s/m) min - max 80 - 115 80 - 140 80 - 165
4
Press Drop (Pa) max 8 13 18
Slot Diffusers
Perimeter throw pattern for VSD diffusers to a maximum terminal velocity of 0.75 m/s with average room velocities of
0.25 m/s. Blade configuration as detailed below to be set up on site, by others.
Diffuser recommended active length between 75% and 80% of facade length.
Maximum air change rates up to 25 per hour using special perimeter blade configuration as detailed below.
Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.
300
150
Façade
2.7m Partition
Wall
ALIGNMENT
PIN
DIM ‘P’ mm
2 123.5
59
3 169
DIM ‘P’ mm INTEGRAL ‘Z0’ 1.5
FLANGE
4 215 11
17
SECTION 6
The direction of air discharge can be adapted on site (by others) to the required room
conditions.
Size Available
1 to 6 slots lengths available in increments of 150mm.
Slot Diffusers
18
SECTION 6
Performance Data
VSD35
Throw (m)
Number of Slots
3.0 m 4.5 m 6.0 m
Air vol. (l/s/m) min - max 15 - 40 15 - 50 15 - 50
1
Press drop (Pa) max 31 44 44
Air vol. (l/s/m) min - max 30 - 60 30 - 70 30 - 75
2
Press drop (Pa) max 15 23 26
Air vol. (l/s/m) min - max 45 - 70 45 - 85 45 - 95
3
Press drop (Pa) max 10 16 20
Air vol. (l/s/m) min - max 60 - 80 60 - 100 60 - 110
4
Press drop (Pa) max 9 14 17
Slot Diffusers
Perimeter throw pattern for VSD diffusers to a maximum terminal velocity of 0.75 m/s with average room velocities of
0.25 m/s. Blade configuration as detailed to be set up on site, by others.
Diffuser recommended active length between 75% and 80% of facade length.
Maximum air change rates up to 25 per hour using special perimeter blade configuration as detailed.
Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.
300
150
Façade
2.7m Partition
Wall
ALIGNMENT
PIN
DIM ‘P’ mm
Dimensions End Angle End Plate
1.5
Number of Dim ‘P’
Slots (mm)
ALIGNMENT PIN
1 62
SLOT
59
2 93
59
3 123
4 154 11 1.5
5 185
DIM ‘P’ mm INTEGRAL ‘Z0’
FLANGE
6 215
19
SECTION 6
20
Performance Data
SECTION 6
ALS25
Throw (m)
Number of Slots
3.0 m 4.5 m 6.0 m
Air vol. (l/s/m) min - max 20 - 55 20 - 70 20 - 80
1
Press drop (Pa) max 22 36 47
Air vol. (l/s/m) min - max 40 - 80 40 - 100 40 - 115
2
Press drop (Pa) max 14 22 29
Air vol. (l/s/m) min - max 60 - 100 60 - 120 60 - 145
3
Press drop (Pa) max 10 15 20
Air vol. (l/s/m) min - max 80 - 115 80 - 140 80 - 165
4
Press drop (Pa) max 8 13 18
Slot Diffusers
Air volume shown is based on diffuser used in a 1-way blow configuration to a maximum terminal velocity of 0.75 m/s
with average room velocities of 0.25 m/s.
Diffuser recommended active length between 75% and 80% of facade length.
Maximum air change rates up to 20 per hour for 1-way discharge pattern, 23 per hour for 2-way discharge pattern.
Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.
ALS25-T2-1 ALS25-T2-2
DIM ‘A’ mm AIR BAFFLE PLATE
IN EACH SLOT
DIM ‘A’ mm
AIR DEFLECTION BLADES
ADJUSTABLE FROM FACE
76
28 25 28
SLOT
DIM ‘P’ mm
28 25 19.5 25 28
SLOT SLOT
DIM ‘P’ mm
75
3 135.0 170.0
4 179.5 214.5
28 1.5
21
SECTION 6
Type ALS20
Supply slot diffuser with integral air straightener, hit and miss damper and air
deflection blades. In the supply mode the discharge can either be set to
horizontal or vertical direction by adjustment of the air deflection blades.
Available as extract diffuser and also blanked dummy variant.
Variable
1) Overall Height (mm)
Plenum Length
(mm) (including diffuser plus
Diffuser Type any neck extension Y)
Spigot
ALS20 (mm)
Number of spigots
Number of Slots 1-4
1-6
M = Spigot Damper
Fixing or no entry
CF = Clip fix D = Lining or no entry
BF = Bridge fix
BX = Bridge fix for extended height plenum
22
Performance Data
SECTION 6
ALS20
Throw (m)
Number of Slots
3.0 m 4.5 m 6.0 m
Air vol. (l/s/m) min - max 15 - 45 15 - 55 15 - 55
1
Press drop (Pa) max 39 55 55
Air vol. (l/s/m) min - max 30 - 65 30 - 80 30 - 85
2
Press drop (Pa) max 19 29 33
Air vol. (l/s/m) min - max 45 - 80 45 - 95 45 - 105
3
Press drop (Pa) max 13 18 22
Air vol. (l/s/m) min - max 50 - 90 50 - 110 50 - 120
4
Press drop (Pa) max 9 14 16
Air vol. (l/s/m) min - max 70 - 100 70 - 125 70 - 135
Slot Diffusers
5
Press drop (Pa) max 7 11 13
Air vol. (l/s/m) min - max 75 - 110 75 - 135 75 - 150
6
Press drop (Pa) max 6 9 11
Air volume shown is based on diffuser used in a 1-way blow configuration to a maximum terminal velocity of 0.75 m/s
with average room velocities of 0.25 m/s.
Diffuser recommended active length between 75% and 80% of facade length.
Maximum air change rates up to 20 per hour for 1-way discharge pattern, 23 per hour for 2-way discharge pattern.
Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.
ALS20-DS-1 ALS20-DS-2
DIM ‘A’ mm AIR BAFFLE/HIT & MISS
SECTION IN EACH SLOT
DIM ‘A’ mm
ADJUSTABLE FROM FACE
AIR DEFLECTION BLADES
76
28 20 28
SLOT
DIM ‘P’ mm
28 20 19.5 20 28
SLOT SLOT
DIM ‘P’ mm
75
3 120.0 155.0
4 159.5 194.5
28 1.5 5 199.0 234.0
6 238.5 273.5
23
SECTION 6
Plenum internally lined with 15mm black faced Class O foam if required.
Slot Diffusers
Order Code
NO - 40mm 40mm
‘L’ Max = 2100 ‘L’ Max = 2100
‘L’ Min = D+100 ‘L’ Min = 2D+100
24
SECTION 6
Dimensions
Slot Diffusers
4 310 181.5 199.5 (D+98) (D+122) 448
‘Bb’ ‘Bb’
‘Ec’ O/A HEIGHT
‘Eb’ O/A HEIGHT
(D+22)
(D+22)
(D+22)
Ø ‘D’
Ø ‘D’
Ø ‘D’
‘Bc’
EXTENSION (*)
TYPICAL SLOT ‘Y’
(VSD TYPE SHOWN)
25
SECTION 7
Size Available
Heights 150 to 450 in increments of 50mm. Length 300mm minimum
Order Code
M-1A Opening size ‘H’ x ‘L’ Type-0 fix 2A Opening size ‘H’ x ‘L’ Type-0 fix
A section AG section
A section AG section
70
70
7 7
50
50
125 125
Blade Pitch Blade Pitch
30 H-22 / L-22 30 30 H-22 / L-22 30
26
SECTION 7
Performance Data
Supply Aerodynamic Data ADM-1
H Pressure Drop (Pa)
in mm <10 <10 12 20 28 38
Volume (l/s/m) 80 120 160 200 240 280
150
Throw (m) 3.3 5.0 6.7 8.4 10.0 11.7
Volume (l/s/m) 120 180 240 300 360
200
Throw (m) 4.1 6.1 8.2 10.2 12.3
Volume (l/s/m) 160 240 320 400
250
Throw (m) 4.7 7.1 9.5 11.8
The above selections meet noise levels up to and including NC35 assuming 8dB room attenuation. ADM linear diffuser
with ceiling effect (horizontal throw). Throw is the distance from diffuser to a velocity of 0.5 m/s.
27
SECTION 8
Type ADT
Square louvred face, removable core, ceiling diffusers type ADT giving horizontal air
discharge, are suitable for use in rooms with ceiling heights between 2.60 and 4.00m.
The recommended supply air temperature differential is ±10K. The ADT diffuser can be
used for supply or extract air applications.
0 No lining
D Lining
28
Diffuser Only
SECTION 8
Type ADTF performance data (without damper, if fitted, 100% open)
4-Way Discharge
Nomenclature: Note:
V̇ in l/s Volume flow per diffuser The throw distance L should be between 75% and 100% of
L in m Distance from the outlet where the maximum the distance to the nearest wall or 50% of the diffuser
time average air velocity is 0.5 m/s spacing dimension, based on a ceiling height of 2.7 - 2.9m.
Δpt in Pa
vk in m/s Diffuser neck velocity
Total pressure drop
LpNC NC rating of room sound pressure level based
on an assumed 8dB room attenuation.
ΔLpNC
Supply +11 +7 +9 +9 +10 +13 +16 +11
Extract +11 +6 +5 +7 +9 +10 +12 +8
1) with 313 Ø spigot 2) with 398 Ø spigot
29
SECTION 8
53
53
7
15
The type ADTF has a shaped flanged border for directly mounting The type ADTT has a flat flanged border to enable the diffuser
to a closed flush ceiling (to maintain horizontal discharge) face to be mounted on the back of an exposed ‘T’ bar or directly
To fit over ceiling opening size (L+100) (H+100) to a closed flush ceiling
Type *ADTH (size 375 only): 495 O/A to ‘lay-on’ 500 square
ceiling ‘T’ supports
53
‘Z’
15
7
available on request
30
SECTION 8
Table 1 - Maximum Spigot Sizes Table 2 - Available spigot sizes 3)
LxH Side Entry Top Entry ØDmm
Available for diffusers type
Nom. Max ØDmm Max ØDmm Subiect to limitations as shown in table 1 & as noted
150 148 123 ADT / F / A / B / T / M / S 98 198 348
225 222 198 ADT / F / A / B / T 123 222 398
300 298 278 ADT / F / A / B / T 138 248 448
375 353 353 ADT / F / A / B / T / H 148 278 498
450 4482) 398 ADT / F / A / B / T / M / S 158 298 558
525 4982) 498 ADT / F / A / B / T 178 313
600 5582) 558 ADT / F / A / B / T
25
Effective
(Refer table 2)
Option Option
(Refer table 2)
E O/A height required
‘ØD’
‘ØD’
(refer to table 3)
Option
type ‘AGF’
Option type
‘AGP’ fitted
ADTF border to the plenum
style shown
(refer table 1)
Option type
272
Notes:
1) For full plenum code details refer to page 28 4) Holes (4) provided at top edge of plenum for hanging by others
2) All plenums, and if required transformations, are supplied loose for site 5) AGF and AGP damper adjustment requires core removal
assembly by others 6) Plenum can be internally lined – code D
3) All full size plenums are supplied with clips for diffuser face fixing (lining material 12mm black faced class O) foam
31
SECTION 8
Low pressure drop and noise levels due to curved blade construction.
32
SECTION 8
Performance Data
Extract
Lwnc 15 21 25 30 35
Size
Pressure Drop (Pa) 10 15 20 30 45
250 Volume (l/s) 30 38 45 54 60
300 Volume (l/s) 50 60 70 90 100
400 Volume (l/s) 90 110 125 170 200
500 Volume (l/s) 180 200 250 300 375
600 Volume (l/s) 300 375 450 500 600
ADLQ louvre diffuser with ceiling effect (horizontal throw). Throw is the distance from diffuser to a velocity of 0.5 m/s for a
4-Way discharge. All selections shown meet NC35 assuming 8 dB room attenuation.
Type ADLQ-AR
Q2-55
65
ADLQ-AR Q1
Q2-58
108
42
Q2
Q1
33
SECTION 8
ØB
ØD
K
ØD
H2
H1
35
ØP ØR1 (ADLR)
6
ØR1 (ADLR)
34
SECTION 8
Performance Data
Ceiling diffuser with ceiling effect (horizontal throw). At diffuser centres shown, maximum terminal velocity is 0.25 m/s
at 1.0m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box
and spigot damper (fully open).
Dimensions
Size ØB ØD H1 H2 K ØP Ø R1 Ø R2
1 201.5 123 233 220 266 202 244 192
2 257.5 158 233 250 290 258 300 248
3 313.5 198 233 295 372 314 356 304
4 369.5 248 267 345 476 362 412 360
5 425.5 248 267 345 476 426 468 416
6 481.5 313 298 410 567 482 542 472
7 537.5 313 298 410 590 578 598 528
8 593.5 313 298 410 615 590 654 584
35
60
ØR2
ØR1 ØR2
593 or 598
35
Perforated Diffuser Type ADLQL
SECTION 9
Type ADLQL ceiling diffuser comprises a perforated diffuser face with rear plenum
box, top or side entry.
Spigot dampers are only available with side entry plenums. Blanking plates are
available on request for site fitting by others.
Order Code
Dimensions
Size ØD DA1 DA2 H1 H2 H3 K1 K2 Q1 Q2
300 158 290 300 300 75 83 274 269 336 298
400 198 390 400 340 75 83 374 369 436 398
500 248 490 500 390 75 83 474 469 536 498
600 313 590 600 455 75 83 574 569 636 598
295 158 - 300 300 - 83 271 266 - 295
595 313 - 600 455 - 83 571 566 - 595
Blanking Plates
ates
Blanking plate
36
SECTION 9
Performance Data
Supply (4 - Way Discharge)
Size Pressure Drop 10 15 20 25 30
Volume (l/s) 45 60 70 78 85
300
Throw (m) 0.7 0.8 1.0 1.1 1.2
Volume (l/s) 80 100 118 130 145
400
Throw (m/s) 0.85 1.1 1.3 1.4 1.5
Volume (l/s) 110 135 158 175 190
500
Throw (m) 0.85 1.1 1.4 1.5 1.6
Volume (l/s) 170 210 240 260 290
600
Throw (m/s) 1.2 1.4 1.6 1.8 2.0
Note: Pressure drop and acoustic data shown is for top entry spigot.
For side entry supply & extract acoustic and pressure drop data refer to leaflet 2/15.1/B/...
Horizontal throw distance from diffuser to a velocity of 0.5 m/s for a 4-Way discharge. All selections shown meet NC35
assuming 8 dB room attenuation.
H1
D A1 Q 2
Q 1 DA2
ØD ØD
H2
8
H3
D A1 Q 2
Q 1 DA2
37
SECTION 10
Size Ø (mm)
G1 - Subframe
100
Supply
125
Z - LVS O - No Subframe
160
Extract 200
LVS
ØC
ØE
ØD
ØE
ØD
8 8
B B
Dimensions
Size B C D E
38
SECTION 10
Performance Data
Type LVS (Extract Valve)
Disc Valves
+5 <5 15 30 52 81 - - - - Pressure
drop
-15 17 70 157 - - - - - - (Pa)
-5 <5 15 36 64 100 144 - - -
160
0 <5 10 22 38 61 88 - - -
+5 <5 5 12 20 33 48 85 - -
-15 5 22 50 89 140 190 - - -
-5 <5 8 17 30 47 68 120 175 220
200
0 <5 <5 11 20 30 40 77 120 150
+5 <5 <5 <5 15 23 30 50 85 100
39
SECTION 11
X
–
VH1
2.7m
Occupied Zone
The layout and centres of the swirl diffusers must be carefully considered to ensure maximum comfort is achieved. We have
provided three alternative arrangements for positioning diffusers, selection methods 1, 2 and 3. Each of the selections will
ensure that the maximum terminal velocity in the occupied zone (VH1) will not exceed 0.25m/s, 1.0m below ceiling.
40
SECTION 11
Selection Method 1 - Rows ≥ 4.0m apart
Diffuser Rows at Centres
≥ 4.0m
Minimum Diffuser at
Centres A
Swirl Diffusers
When the diffuser rows are at least 4.0m apart,
the minimum diffuser centres should be ‘A’.
41
SECTION 11
Type SDW
Square faced adjustable blade swirl diffuser. Type SDW is available in a range of sizes.
The removable face plate is held in the plenum box with a centre screw fixing. The
head of the screw is covered with a decorative cap.
The plenum box is available with side or top entry spigot and a volume control
damper.
42
SECTION 11
Performance Data
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A 100 37 95 30 105 40 120 46 140 65 - -
400 x 16 2, Centres B 75 20 70 18 75 20 85 27 100 47 - -
3, Centres C 25 5 45 7 65 15 85 27 110 43 - -
1, Centres A 140 40 120 27 130 33 140 38 160 50 - -
500 x 24 2, Centres B 100 20 85 14 90 18 100 20 120 27 - -
3, Centres C 35 5 55 9 75 11 100 20 120 27 - -
1, Centres A 150 18 145 17 110 20 180 25 210 35 250 50
600 x 24 2, Centres B 110 10 105 9 110 10 130 14 152 18 180 25
Swirl Diffusers
3, Centres C 40 3 65 4 85 6 115 11 170 23 220 38
1, Centres A 190 23 170 18 180 20 195 24 220 30 300 55
600 x 48 2, Centres B 130 11 110 8 120 9 140 13 180 22 200 29
3, Centres C 50 2 80 4 90 6 120 9 180 22 230 33
Note: Vol = Volume (l/s) Pa = Pressure Drop
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
For Selection Methodology see page 40.
250
15 15
Q
15 584 face size 584 face size
8
8
25
Type Q Type QL Type QS15 Type QM15
Face-mounted To ‘Lay-on’ To ‘Lay-on’ Tegular tee-bar To ‘Lay-on’
FLAT tee-bar 15mm wide x 8mm deep Tegular tee-bar
15mm wide x 16mm deep
43
SECTION 11
Type VDW
Adjustable swirl diffusers type VDW are supplied in a range of sizes. The face
plate is circular to suit the architectural requirements
The removable face plate is held in the plenum box with a centre screw fixing.
The head of the screw is covered with a decorative cap.
The plenum box is available with side or top entry spigot, with volume control
damper and / or lip seal on request.
Order Code
VDW - R - Z - V - M - L / 600 x 24 / 0 / 0 / P1 / RAL 9010 / 20% Gloss
R = Circular
L = Spigot with lip seal 0 = Supply air: black air control blades
Z = Supply
Extract air: no air blades
A = Extract M = Volume control damper
Q11 = Extract air: black air control blades
with adjustable lever
V = Top entry plenum 1)
Q21 = Supply air: white air control blades
MN = Volume control damper
H = Side entry plenum Extract air: white air control blades
with cable and test connection
ØD
H2
H1
35
8
ØR/Q ØP
ØR
Type VDW-R-...-
ØR
44
Performance Data
SECTION 11
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A 100 37 95 30 105 40 120 46 140 65 - -
400 x 16 2, Centres B 75 20 70 18 75 20 85 27 100 47 - -
3, Centres C x C 25 5 45 7 65 15 85 27 110 43 - -
1, Centres A 140 40 120 27 130 33 140 38 160 50 - -
500 x 24 2, Centres B 100 20 85 14 90 18 100 20 120 27 - -
3, Centres C x C 35 5 55 9 75 11 100 20 120 27 - -
1, Centres A 150 18 145 17 160 20 180 25 210 35 250 50
600 x 24 2, Centres B 110 10 105 9 110 10 130 14 152 18 180 25
Swirl Diffusers
3, Centres C x C 40 3 65 4 85 6 115 11 170 23 220 38
1, Centres A 190 23 170 18 180 20 195 24 220 30 300 55
600 x 48 2, Centres B 130 11 110 8 120 9 140 13 180 22 200 29
3, Centres C x C 50 2 80 4 90 6 120 9 180 22 230 33
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral
collar > 50mm is fitted.
Dimensions
ØR Size B D H1 H2 P K
300 300 x 8 280 158 200 250 278 290
400 400 x 16 364 198 200 295 362 372
500 500 x 24 462 198 200 295 460 476
600 600 x 24 559 248 200 345 557 567
600 600 x 48 580 248 300 345 578 590
45
SECTION 11
Type FD
Type FD swirl diffusers are available in various sizes. Depending on the
architectural requirements, the face plate can be circular or square. The fixed air
control blades on the diffuser face are arranged radially.
The diffuser face can be attached or removed via a centre fix screw into the
plenum box. The screw head is covered with a decorative cap. The plenum box
can be supplied with either top or side entry spigots and on request, with spigot
lip seals and volume control damper.
If a circular diffuser face is ordered, the plenum box with side entry spigot has a
35mm extension piece fitted to the plenum.
Swirl Diffusers
Order Code
FD - Q - Z - V - M - L / 400 / 0 / 0 / P1 / RAL 9010 / 20% Gloss
Q = Square
R = Circular L = Spigot with lip seal
Z = Supply M = Volume control damper with single blade
A = Extract 1)MN = Volume control damper with cable and test connection
V = Top entry plenum
H = Side entry plenum NOTE: 1) Only for side entry spigot
ØB
K
ØD
K
40
ØD
H2
ØD
H2
200
35
8
8
Q ØP ØR/Q
ØR
fixing screw
for diffuser face
46
Performance Data
SECTION 11
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A 85 65 75 60 80 63 - - - - - -
300 2, Centres B 60 36 54 30 58 33 60 36 70 50 80 63
3, Centres C x C - - 35 13 45 20 58 33 80 63 - -
1, Centres A 125 55 110 40 118 48 120 50 140 65 - -
400 2, Centres B 85 25 78 20 82 23 90 27 100 35 120 50
3, Centres C x C - - 52 9 68 15 80 21 100 35 130 55
1, Centres A 150 40 130 28 135 30 150 40 170 48 - -
500 2, Centres B 105 18 92 14 97 16 105 18 120 23 140 30
Swirl Diffusers
3, Centres C x C - - 65 7 85 12 100 17 125 25 155 42
1, Centres A 160 26 145 20 150 21 160 26 185 30 220 45
600 2, Centres B 115 12 100 9 110 11 120 13 135 15 160 25
3, Centres C x C - - 70 5 95 8 115 12 145 20 175 28
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral
collar > 50mm is fitted.
Dimensions
Size ØB ØD ØL Q ØR H2 K ØP
300 280 158 254 298 300 250 290 278
400 364 198 336 398 400 295 372 362
500 462 198 440 498 500 295 476 460
600 559 248 530 598 600 345 567 557
47
SECTION 11
Type DCS
Type DCS-P air diffusers consist of the perforated face plate with a thin acoustic
fleece lining on the rear. In type DCS-N, the face plate is made of plain sheet steel
with perimeter returned edge with central perforated plate insert.
The rear swirl diffuser includes a discharge nozzle ring and radially arranged fixed
air control blades and connection collar. If required, can be supplied with top entry
spigot piece or side entry plenum box with circular spigot. Plenum box can have
internal acoustic insulation if specified.
Order Code
DCS - P - V - AK / 593 x 315 / 0 / 0 / P1 / RAL 9010 / 20% Gloss
Type
Size (mm) Not Used Powder coat finish
Face Plate 5931)
P = Perforated 5982)
N = Non-perforated
C = With discharge
K = Connecting collar
nozzle ring
US = Top entry spigot
V = Visible1) A = Plenum box
H = Hidden2) AK = Plenum box with acoustic insulation
ØC
ØB
ØR
ØD
H1
593 ( 598)
H2
ØC
ØB
ØR
Type DCS-P-...-US
Size...x 125 and ...x 160 593 ( 598)
without perforated plate
ØD
Type DCS-...-H-US
40
H3
Hanging
Bracket
8
ØC
ØB
ØR 598
593 ( 598) 600
48
SECTION 11
Performance Data
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A - - 50 65 50 65 - - - - - -
160 2, Centres B 35 31 35 31 38 41 39 43 45 50 50 65
3, Centres C - - 23 14 30 24 40 45 - - - -
1, Centres A 70 50 62 44 62 44 68 45 75 55 - -
200 2, Centres B 42 20 45 24 47 25 51 27 56 29 65 45
3, Centres C - - 32 10 40 17 55 28 70 50 - -
1, Centres A 95 40 78 26 76 25 90 35 - - - -
250 2, Centres B 51 11 54 13 57 18 63 17 70 20 80 27
Swirl Diffusers
3, Centres C - - 35 5 47 9 63 17 75 25 100 45
1, Centres A 125 25 105 18 110 20 120 22 140 30 170 45
315 2, Centres B 70 7 75 9 80 11 85 12 100 17 110 20
3, Centres C - - 45 4 65 6 85 12 110 20 140 30
1, Centres A 125 8 115 7 125 8 140 12 155 11 170 16
400 2, Centres B - - - - - - 100 6 115 7 130 9
3, Centres C - - - - - - 100 6 130 9 150 10
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
Dimensions
Size ØA ØB ØC ØD H1 H2 H3 K K1 ØR
...X 160 158 235 210 123 180 79 159 215 237 250
...X 200 198 275 250 158 215 79 162 255 277 300
...X 250 248 325 300 198 255 76 167 305 327 350
...X 315 313 410 385 248 305 89 184 370 392 450
...X 400 398 495 470 313 361 89 194 454 476 500
Hanging
bracket
593
Hanging
600
bracket
593
600
49
SECTION 11
Type TDF
TDF - SilentAIR swirl diffusers are available in various sizes. In accordance with
architectural requirement the face plate can be circular or square. The fixed air
guiding elements of diffuser face are radially arranged.
The diffuser can be fastened to the plenum box by means of a central screw
and cover cap.
The plenum box can be supplied with a horizontal or vertical air connection,
or upon request with a volume control damper and / or a sealing lip.
Order Code
50
Performance Data
SECTION 11
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A 80 45 80 45 80 45 80 45 80 45 80 45
300 2, Centres B 62 28 62 28 62 28 62 28 70 38 80 45
3, Centres C 25 5 37 10 48 17 62 28 80 45 80 45
1, Centres A 92 20 92 20 92 20 92 20 100 28 110 33
400 2, Centres B 80 17 80 17 80 17 80 17 100 28 120 37
3, Centres C - - 45 5 65 11 80 17 110 33 135 45
1, Centres A 135 30 135 30 135 30 135 30 140 33 150 38
500 2, Centres B 100 17 100 17 100 17 100 17 120 22 150 38
Swirl Diffusers
3, Centres C - - 60 6 80 10 95 14 125 25 165 45
1, Centres A 160 22 160 22 160 22 160 22 165 24 190 30
600 2, Centres B 115 10 115 10 115 10 115 10 135 14 180 27
3, Centres C - - - - 90 7 115 10 145 17 190 30
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral
collar > 50mm is fitted.
Dimensions
Size ØB ØD ØL Q ØR H2 K ØP
300 280 158 254 298 300 250 290 278
400 364 198 336 398 400 295 372 362
500 462 198 440 498 500 295 476 460
600 559 248 530 598 600 345 567 557
625 559 248 530 623 623 345 567 557
H2
ØD
H2
ØD
200
35
8
Q/ØR Q ØP
ØR
51
SECTION 11
Type TDV
The diffuser face of the type SilentAIR offers a high volume flow rate at low sound
power levels. The horizontal swirl-type discharge of the supply air ensures high
induction and hence rapid reduction in jet velocity and temperature differential.
Suitable for supply air temperature differentials up to ±10°K.
Order Code
TDV - SA - Q - Z - V - M - L / 400 / 0 / Q21 / P1 / RAL 9010 / 20% Gloss
ØL
ØL
52
Performance Data
SECTION 11
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A 80 45 80 45 80 45 80 45 80 45 80 45
300 2, Centres B 65 30 65 30 65 30 65 30 70 37 80 45
3, Centres C - - 40 13 50 19 60 25 75 40 80 45
1, Centres A 120 36 120 36 120 36 120 36 120 36 120 36
400 2, Centres B 85 19 85 19 85 19 85 19 100 27 120 36
3, Centres C - - 50 6 65 12 80 16 110 30 120 36
1, Centres A 150 38 150 38 150 38 150 38 155 39 160 40
500 2, Centres B 100 17 100 17 100 17 100 17 125 25 150 38
Swirl Diffusers
3, Centres C - - 65 8 80 10 100 17 140 30 160 40
1, Centres A 170 25 170 25 170 25 170 25 180 28 200 34
600 2, Centres B 120 12 120 12 120 12 120 12 140 16 190 30
3, Centres C - - - - 100 9 120 12 150 18 180 28
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
Dimensions
Size ØB ØD ØL Q ØR H2 K ØP
300 280 158 254 298 300 250 290 278
400 364 198 336 398 400 295 372 362
500 462 198 440 498 500 295 476 460
600 559 248 530 598 600 345 567 557
625 559 248 530 623 623 345 567 557
ØB
K
ØD
K
~32
~32
40
H2
ØD
H2
ØD
200
35
8
Q/ØR Q ØP
ØR
53
SECTION 11
Type RFD
Available in either circular or square face plate, with or without discharge
nozzle, to suit architect requirements.
Type RFD-...-UO or RFD-...-UD, top entry plenum boxes are inclusive of internal
subframe which holds the diffuser in position by central fixing bolt and
covering cap.
Swirl Diffusers
Order Code
RFD - Q - D - A - M - L / 200 / 0 / 0 / P1 / RAL 9010 / 20% Gloss
Type
Size (mm) Not Used Powder coat finish
Diffuser Face
125
Q = Square
160
R = Circular
200
D = nozzle 250
315
K = Connecting ring
400
US = Top entry plenum
UD1) = Top entry plenum with L = Plenum box with lip seal
internal subframe (discharge
M = Volume control damper with operating rod
nozzle construction) 2)MN= Volume control damper with sheathed cable and test nipple
UC1) = Top entry plenum with internal
subframe (no discharge nozzle) 1)
NOTE: Only available with circular construction
A = plenum box side entry 2) Not available with N
N1) = Low profile plenum box
U4
ØR2
Q2
8
40
xD
H3
U6
H1
H4
ØR2
xC
8
wQ
1
x R1
54
Performance Data
SECTION 11
Diffuser Centres (m)
Size Selection Method 1.2 m 1.8 m 2.4 m 3.0 m 3.6 m 4.2 m
Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa Vol Pa
1, Centres A 40 70 35 50 35 50 38 60 45 80 50 100
125 2, Centres B 25 28 24 20 27 35 29 38 32 45 38 60
3, Centres C - - 18 15 23 19 29 38 40 70 50 100
1, Centres A 55 55 47 40 47 40 53 50 60 65 70 95
160 2, Centres B 32 18 33 19 35 21 37 27 40 30 47 40
3, Centres C 15 9 24 12 30 16 40 30 55 55 70 95
1, Centres A 67 37 63 34 63 34 68 38 75 45 85 65
200 2, Centres B 43 14 45 15 48 18 50 20 55 24 65 35
Swirl Diffusers
3, Centres C - - 30 8 38 9 50 20 68 38 90 70
1, Centres A 110 40 80 23 80 23 100 36 120 50 140 70
250 2, Centres B 52 10 53 11 54 11 55 12 68 15 78 20
3, Centres C - - 35 4 45 7 55 12 60 13 95 32
1, Centres A 115 18 105 15 105 15 110 17 130 25 140 27
315 2, Centres B 72 8 75 8 78 9 80 9 90 11 100 14
3, Centres C - - 45 2 60 5 80 9 105 15 145 29
1, Centres A 130 14 118 11 120 12 140 16 155 18 175 25
400 2, Centres B - - - - 90 7 105 9 120 12 135 15
3, Centres C - - - - - - 100 8 125 13 150 17
Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25
m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum
box and spigot damper (fully open).
Dimensions
Size ØA ØC ØD H1 H3 H4 K Q1 Q2 Ø R1 Ø R2 U2 U4 U6
125 123 123.5 98 259 195 178 216 198 198 158 200 75 153 192
160 158 158.5 123 284 220 190 266 198 248 197 250 78 158 196
200 198 198.5 158 314 250 202 290 248 248 241 300 78 161 197
250 248 248.5 198 359 295 227 476 298 298 295 350 75 166 202
315 313 313.5 248 409 345 252 567 398 398 364 450 88 183 219
400 398 398.5 313 474 410 285 615 498 498 450 580 88 193 229
55
SECTION 12
Fixed construction type DUK-F consists of a nozzle with fixing holes. Adjustable
construction type DUK-V consists of a spherical discharge nozzle mounted flange and
circular spigot for direct connection to a circular duct. The nozzle can be adjusted
manually up to max. 30° in any direction. The adjustment can be motorised with an
electric or pneumatic actuator. With an actuator the nozzle can only be rotated in one
plane up to 30° upwards (cooling) and up to 30° downwards (heating).
Order Code
DUK - V - K - E1 / 250 / 0 / 0 / P3 / RAL 9010 / 20% Gloss
NOTE: 1) Drilled for fixing as standard: extra text required on order if no holes are required.
For sizes 100 and 125, construction with actuator not available
Performance Data
Size
Volume (l/s) 13 17 22 28 35
100 Throw L (m) 3.9 4.5 5.8 6.9 9
Rise + Fall (m) 0.6 0.43 0.44 0.5 0.62
Volume (l/s) 17 25 35 45 55
125 Throw L (m) 3.9 5 7 8.5 11
Rise + Fall (m) 0.55 0.5 0.75 0.9 1.3
Volume (l/s) 23 35 50 70 95
160 Throw L (m) 3.5 5.1 7.5 10.5 14
Rise + Fall (m) 0.38 0.3 1.1 1.6 1.8
Volume (l/s) 29 55 85 120 180
200 Throw L (m) 3.8 6.5 10 13 21
Rise + Fall (m) 0.6 1.1 2 3.3 3.4
Volume (l/s) 37 60 95 140 190
250 Throw L (m) 3.8 5.4 8.5 12.5 17.8
Rise + Fall (m) 0.9 1.5 1.6 2.8 3.3
Volume (l/s) 50 100 200 300 400
315 Throw L (m) 3.9 7 13.8 21 28
Rise + Fall (m) 1.3 1.8 3 4.9 9
Volume (l/s) 65 150 250 350 500
400 Throw L (m) 3.9 9 13 18.5 25
Rise + Fall (m) 1.7 2.5 4 4.6 7
Based on horizontal discharge with air temperature ±10k above or below room temperature to a terminal velocity of 0.75
m/s without ceiling effect. Selections meet NC45 assuming 15dB room attenuation.
56
SECTION 12
Heating
rise
D d i i di l i l
Jet Nozzles
Dimensions
Possible Circular Duct Diameters R
Size D1 D2 D3 D4 D5 E F K L1 L2 L3 Size
200 250 315 500 630 800
100 136 115 146 98 50 10 -2 134 94 78 80 100 •
125 159 138 169 123 64 10 4 157 112 89 90 125 •
160 225 201 200 158 82 11 10 188 122 106 110 160 • • • •
200 265 241 257 198 108 16 14 242 153 127 140 200 • • •
250 315 291 302 248 136 16 23 287 187 159 170 250 • • •
315 400 376 384 313 174 23 29 358 224 189 220 315 • • •
400 485 461 467 398 230 24 47 441 287 223 260 400 • •
*For constructions with actuators, L3 = 365mm irrespective of size.
øR
øD3
60°
60°
øD3
øK
øD4
øK
DUK-V-A-P
DUK-V-K-P
DUK-V-R-P DUK-V-K-E1...E3 (shown)
DUK-V-A-P
DUK-V-K-P
Type DUK-V-R
Examples of circular duct connection
E
øD4
øD5
øD3
Type DUK-V
15
L2 F
DUK V
Type DUK-V-K
L1 Counterpunched hole Ø 4.5mm
9 for raised countersunk
Examples of rectangular duct connection self-tapping
screws 4.2 x 16, DIN 7973
ØD1
ØD2
ØD5
57
SECTION 12
Border supplied undrilled as standard, type CF comes without the square face plate.
Jet Nozzle can be adjustable 30° upwards to 30° downwards. The Nozzle mounting
plate can also be rotated through 360° which enables the air jets to be fully
directional.
One, two, three or four elements are available and there are four sizes to choose from.
TROX jet nozzle can be installed singularly or in banks.
Order Code
AJA - CF - A / 250 X 2 / 0 / 0 / P3 / RAL 9010 / 20% Gloss
Type
Size Not Used 0 = drilled (screwfix)
CF = Circular Face 200 X = undrilled
or blank 250
Powder coat finish
300
Rear Assemblies
350 Number of elements
A = Without 1)1 - 4
Order Code
AK - AJA - ZV - AG / 250 X 2 / 0 / GO
Plenum
Size (mm)
Nozzle Type Not Used
200
250
ZV = supply nozzle with inline connection Number of elements
300 1) 1
AG = Damper or blank -4
350
NOTE: 1)Plenum for CP (circular face) only available for single element units
Dimensions
Nominal Size
Size
C L2 L3 L4 ØA E F WxZ B H
200 350 650 950 1250 200 50 180 310 310 200 200
250 400 750 1100 1450 250 65 195 360 360 250 250
300 450 850 1250 1650 300 75 205 410 410 300 300
350 500 950 1400 1850 350 85 235 460 460 300 350
Heating
30
rise
C
fall
L2
Jet Nozzle Throw Cooling L3
30
L L4
Jet Nozzles
Throw L (m) 8 9 11 12 14 15 17 21 24 28
200
Rise + Fall (m) 5.0 5.5 6.0 6.5 7.5 8.0 9.0 11.0 13.0 16.0
Throw L (m) 11 12 14 15 18 21 24 28 29
2 Element 250
Rise + Fall (m) 7.5 8.0 9.0 10.5 12.0 13.0 14.5 16.0 19.0
Throw L (m) 9 11 12 14 15 18 21 24 26
300
Rise + Fall (m) 7.0 10.0 11.0 12.5 14.5 15.5 18.0 20.0 22.0
Throw L (m) 12 14 15 18 20 21
350
Rise + Fall (m) 19.0 24.0 29.0 31.0 33.0 35.0
Based on horizontal discharge with air temperature ±10K above or below room temperature to average terminal velocity of
0.25m/s without ceiling effect. Selections meet NC45 assuming 15dB room attenuation.
Type AJA
Standard type with square face section. Border: for plenum or flanged duct fitting.
F
Flange duct section Installation
E
Suspension by others
Duct
30
Lockable lever
A Nominal size
Conical Adjustment
W x Z duct size
Ø A nom size
BxH
C
60°
30
450
59
The art of handling air
TROX UK Ltd
Caxton Way
Thetford
Norfolk IP24 3SQ
Design changes reserved. All rights reserved © TROX UK Ltd (06/2009)