5 mm
angle beam
Surface Condition
Equipment
Transducer
Rectangular crystal
20 x 22 mm or 8 x 9 mm for Pipes
Frequency 2 to 4 MHz
Angle of the probe to be selected based on the curvature and penetration to ID.
Couplant
A liquid couplant
sin = 1-(t/r)
=38 deg
Depth of penetration
Diameter = 400 mm
Thickness =75 mm
t = 200(1-Sin45) = 200(1-0.7)
= 200 x 0.3
Penetrating thickness = 60 mm
Due to curvature, wall thickness and probe angle, the sound beam may not strike the ID surface
.The minimum probe angle can be calculated and it is called as Irradiation factor.
IR = Inner Radius
OR = Outer Radius
Sin β = ID/OD
Reference Block
surface finish
Longitudinal(axial)notch on OD & ID
(3 % / 5% / 10 % of thickness)
length- 6 mm
or
The examination shall be for 100% of the pipe & 100% of length and dia
All indications that are equal to or greater than the rejection level or as specified by the Contract
shall be considered as defects