You are on page 1of 8

Moment & Shear Strength Design of Rectangular RC Beam According ACI318M-08 , Rev06.

3
Project :- MOI SFMC Designed by:- M. Abu Shady
Building :- C03.00 Ambulance driveway Tunnel Wall Checked by:- M. Abu Shady
Element:- B-LE-51J Date:- 31-Dec-21
Location:- Entry Level @ GL 24-32 M.A.S.
General Input :-
Moment Mx Input
Width b 1500 mm Dia 32 mm
Depth h 1200 mm Es 200000 N/mm2

cover 40 mm εc 0.003 mm

fy 420 N/mm2 εy 0.0021 mm


fc' 45 N/mm 2
Ec 31529 N/mm2 ACI 8.5.1
Mu 10850 KN.m d 1134 mm
Shear & Torsion Input d' 66 mm
Vu 3174 KN fyt 420 N/mm2
Tu 2766 KN.m Case G For Non-seismic Cases
Nu 0 KN Comp. α st Deg. 90o Deg.
a- Major Moment ( Mx) Design:-
finding ρ max ACI 10.3.3
β1 0.73 ACI 10.2.7.3 ρp 0.03903 ACI B.8.4.2
ρmin 0.00399 ACI 10.5.1 ρmax 0.02927 ACI 10.3.5

finding balanced moment strength


Cb 667 mm ab 486 mm
amax 365 mm Cmax 500 mm ACI 10.3.3
Φ 0.90 Tension controlled section ACI 9.3.2.1 & 10.3.4
ΦMnbalance 17913.7 KN.m < Mu Use Tension RFT. Only
Rectangular Section with Tension & Compression RFT.
M' = 0.0 KN.m Ru 6.24985
u

ρ'req 0.00000 ρreq 0.01635


A's required 0 mm2 0 T 32
As required 27808 mm2 35 T 32
A's actual 0 mm2 0 T 32 TOP OK, <= ρmax=0.04 bd
As actual 33768 mm 2 42 T 32 OK, <= ρmax=0.04 bd

check Compression Steel yield


a 247.2 mm C 339.3 mm
εtension steel 0.0070 εs>εy εs' 0.0000
Cconcrete 14182560 N Cst 0 N
ΦMn 12897.1 KN.m Ok, ΦMn > Mu
b- Major Shear ( V2 ) Design :-
Finding Vc ACI 11.3
𝜑 𝑠ℎ𝑒𝑎𝑟 0.75 ACI 9.3.2.3 & ACI 9.3.4.a
𝜑𝑉_𝑐 1454.9 KN ACI 11.2.1.1 & ACI 11.2.2.3 Vu>ΦVc
𝜑𝑉_(𝑠 5648.3 KN ACI 11.4.7.9
𝑚𝑎𝑥)
𝜑𝑉_𝑛 7103.1 KN ACI 11.1.1 Section Dimension is OK for shear

Page 1 of 8
Moment & Shear Strength Design of Rectangular RC Beam According ACI318M-08 , Rev06.3
Project :- MOI SFMC Designed by:- M. Abu Shady
Building :- C03.00 Ambulance driveway Tunnel Wall Checked by:- M. Abu Shady
Element:- B-LE-51J Date:- 31-Dec-21
Location:- Entry Level @ GL 24-32 M.A.S.
Av min /S 1.485 mm2 /S ACI 11.4.6.3
Vs 1719.1 KN ACI 11.1.1 Shear Rft. for Shear Force only Av act. /S
Av /S 4.813 mm2 /S ACI 11.4.7.4 use 6 br. T 16 @ 100 =12.1 mm2/S

c- Torsion design:- Ok vaild


Acp = Ag 1800000 mm2
Aoh 1590400 mm2
Ao 1351840 mm2 ACI 11.5.1
Pcp 5400 mm
Ph 5080 mm
Tcr 1328 KN.m Threshold Torsion ACI 11.5.1.c
Tneglected 249.0 KN.m ACI 11.5.1.c Torsion shall be considered, Tu > Tneglected
Factored Torsion Moment ACI 11.5.3.1

= 3.763 < = 3.962 ACI 11.5.3.1.a

Section Dimension is OK for tosion


Finding Torsion Stirrups At
θ 45 Deg. ACI 11.5.3.6.a
At min /S 0.625 mm /S2
ACI 11.5.5.3
At /S 3.248 mm /S2
ACI 11.5.3.6 Shear Rft. is required for Torsion
Required Shear Rft. for both shear & Torsion Force:
Av Total req stirrups /S 11.308 mm2 /S ACI 11.5.5.2
1- Outer Stirrup to resist Torsion and part of shear force:
Av actual Outer stirrup 6.280 mm2 /S use 2 br. T 20 @ 100 Closed Stirrup

2- inner Stirrups to resist the rest of shear force::


No. of branches for inner stirrups = 6 br.
Av req inner stirrup 5.028 mm2 /S
Av actual inner stirrup 12.060 mm2 /S use 6 br. T 16 @ 100 Ordinary Stirrups
Ok Av actual for inner stirrups > Av required
Finding Torsion Longitudinal RFT Al
Al min 11909.8 mm2 ACI 11.5.5.3
Al 16498.7 mm2 ACI 11.5.7 21 T 32
d- Beam Reinforcement details:
Cover= 40
6 T 32 TOP BARS

2br. T20@100mm, Outer Closed Stirrup


Depth= 1200 6br. T16@100mm, inner Ordinary Stirrups
6 T 32 SIDE BARS E.F
40 T 32 BOT. BARS
Width= 1500

Page 2 of 8
DIA (mm) Area (mm2) Case Element Type
6 29 E For Seismic Cases Beam
8 51 G For Non-seismic Cases Slab
10 79 Env. For Environmental Structures
12 114
14 154
16 201
18 255
20 314
22 380
25 491
32 804
REV 01: start

REV 02:
Select the Element Type( Beam or Slab) in cell F1 it will affect As min
As min For Beams & Slabs

REV 03:
in Torsion check, if the tension force is huge, the concrete
resistance will neglected according ACI 11.5.1.c _cell C73
REV 04:
changing Astirrup total equation in cell C84 to equal to 0.0 if there are no stirrups needed
new equation is =IF((Av+nst*At)>0,MAX(Av+nst*At,Avmin),0)
Blue color is new part in this equation

REV 05:
1- changing Cmax to Cc in εs' calculation in cell C49
2- Calculated Φcalculated in cell(J3) beside the sheet to allow user to modify the used on according ACI 9.3.2.1 & 10.3.4
3- in shear check, if the Nu is tension force, we will use Eq. 11-3 instead of 11-4 according ACI 11.2.1.2 _cell C57
REV 06: Date: 01-May-2013
1- adding row 66 which was removed by mistake in rev 05
this row show a message to change the cross-section for torsion
and have the following equation "=IF(D64<=G64,"Section Dimension is OK for torsion","Change Section Dimension
2- changing the text message in the following cells:
G36, G37, G50, F61, B66
3- Rearranging the Stirrups calculation for shear and torsion, from row 69 to end
the outer stirrups supports the torsion + part of shear forces
the inner stirrups supports the rest of shear force
4- changing the calculation of stirrups RFT. To be Av/S & At/S , to be easy to compared with Etabs Value
in row 51, 53, 67, 68
REV 06.1:
adding new comment message in cell H42, (=IF(Vu>Vc,"Vu>ΦVc","Vu<ΦVc Concrete can resist shear alone"))
multiply equation in cell C42,43 by Φshear
REV 06.1:
modify equation in cell C46 to be =Vu-Vc instead of =Vu-ΦVc regarding to changes in rev 06.1
REV 06.3:
A note is added @ cell G64
Equation in cell C66 Astirruptotal is corrected to show 0 if no shear rft, is required for both shear and torsion.
A note is added @ cell G66
Equation in cell C71 Ast_inner_req is corrected to show 0 if inner stirrup is not required.
ACI 9.3.2.1 & 10.3.4
1.2.1.2 _cell C57
","Change Section Dimension for torsion")"

hear alone"))

and torsion.