Professional Documents
Culture Documents
3
Project :- MOI SFMC Designed by:- M. Abu Shady
Building :- C03.00 Ambulance driveway Tunnel Wall Checked by:- M. Abu Shady
Element:- B-LE-51J Date:- 31-Dec-21
Location:- Entry Level @ GL 24-32 M.A.S.
General Input :-
Moment Mx Input
Width b 1500 mm Dia 32 mm
Depth h 1200 mm Es 200000 N/mm2
cover 40 mm εc 0.003 mm
Page 1 of 8
Moment & Shear Strength Design of Rectangular RC Beam According ACI318M-08 , Rev06.3
Project :- MOI SFMC Designed by:- M. Abu Shady
Building :- C03.00 Ambulance driveway Tunnel Wall Checked by:- M. Abu Shady
Element:- B-LE-51J Date:- 31-Dec-21
Location:- Entry Level @ GL 24-32 M.A.S.
Av min /S 1.485 mm2 /S ACI 11.4.6.3
Vs 1719.1 KN ACI 11.1.1 Shear Rft. for Shear Force only Av act. /S
Av /S 4.813 mm2 /S ACI 11.4.7.4 use 6 br. T 16 @ 100 =12.1 mm2/S
Page 2 of 8
DIA (mm) Area (mm2) Case Element Type
6 29 E For Seismic Cases Beam
8 51 G For Non-seismic Cases Slab
10 79 Env. For Environmental Structures
12 114
14 154
16 201
18 255
20 314
22 380
25 491
32 804
REV 01: start
REV 02:
Select the Element Type( Beam or Slab) in cell F1 it will affect As min
As min For Beams & Slabs
REV 03:
in Torsion check, if the tension force is huge, the concrete
resistance will neglected according ACI 11.5.1.c _cell C73
REV 04:
changing Astirrup total equation in cell C84 to equal to 0.0 if there are no stirrups needed
new equation is =IF((Av+nst*At)>0,MAX(Av+nst*At,Avmin),0)
Blue color is new part in this equation
REV 05:
1- changing Cmax to Cc in εs' calculation in cell C49
2- Calculated Φcalculated in cell(J3) beside the sheet to allow user to modify the used on according ACI 9.3.2.1 & 10.3.4
3- in shear check, if the Nu is tension force, we will use Eq. 11-3 instead of 11-4 according ACI 11.2.1.2 _cell C57
REV 06: Date: 01-May-2013
1- adding row 66 which was removed by mistake in rev 05
this row show a message to change the cross-section for torsion
and have the following equation "=IF(D64<=G64,"Section Dimension is OK for torsion","Change Section Dimension
2- changing the text message in the following cells:
G36, G37, G50, F61, B66
3- Rearranging the Stirrups calculation for shear and torsion, from row 69 to end
the outer stirrups supports the torsion + part of shear forces
the inner stirrups supports the rest of shear force
4- changing the calculation of stirrups RFT. To be Av/S & At/S , to be easy to compared with Etabs Value
in row 51, 53, 67, 68
REV 06.1:
adding new comment message in cell H42, (=IF(Vu>Vc,"Vu>ΦVc","Vu<ΦVc Concrete can resist shear alone"))
multiply equation in cell C42,43 by Φshear
REV 06.1:
modify equation in cell C46 to be =Vu-Vc instead of =Vu-ΦVc regarding to changes in rev 06.1
REV 06.3:
A note is added @ cell G64
Equation in cell C66 Astirruptotal is corrected to show 0 if no shear rft, is required for both shear and torsion.
A note is added @ cell G66
Equation in cell C71 Ast_inner_req is corrected to show 0 if inner stirrup is not required.
ACI 9.3.2.1 & 10.3.4
1.2.1.2 _cell C57
","Change Section Dimension for torsion")"
hear alone"))
and torsion.