You are on page 1of 5

Código Nome

iTC 000158.03 Switched Voltage Is Too High


Switched voltage is greater than 32 VDC
iTC 000158.04 Switched Voltage Is Too Low
Switched voltage is less than 9 VDC
iTC 000168.03 Unswtiched Voltage Is Too High
Unswitched power is greater than 32 VDC
iTC 000168.04 Unswitched Voltage Is Too Low
Unswitched power is less than 9 VDC.
iTC 000168.18 RTK Base Station Voltage Low
RTK base station voltage is below 11 VDC.
iTC 000232.02 Corrected GPS Position Not Available
There is no differential correction.
iTC 000232.14 RTK Extend Lost
Indicates that RTK correction signal will be lost in a stated period of time.
iTC 000639.14 CAN Bus Off
No CAN communication is taking place with control unit iTC
iTC 000841.07 GPS Receiver Internal Failure
Communication lost with GPS receiver and navigation processor
iTC 000841.31 Signal Interference From Satellite
Remove the interference.
iTC 000956.16 Roll Sensor Is Out Of Normal Range
Replace STARFIRE iTC receiver.
iTC 002146.13 TCM Not Calibrated
Calibrate TCM.
iTC 002146.14 iTC Temperature Sensor Out Of Range
Position is not being corrected. Replace STARFIRE iTC receiver.
iTC 002854.31 RTK Rover Radio Link Lost

Check radio connections. Refer to StarFire 3000 receiver diagnostics if that unit is present, for all others, use the RTK diagnostics.
iTC 003141.14 Receiver To Base Station Authorization Problem
The GPS receiver is not authorized on this RTK network. Refer to Operator's manual.
iTC 003141.31 GPS Corrections License Expired
GPS corrections license has expired.
iTC 003144.13 Receiver Frequency Calibration Problem
Receiver can not link to StarFire network on the alternate frequency. Change frequency to Default.
iTC 522338.13 Receiver Not Receiving On Alternate Frequency
Frequency has been changed from default. Change frequency to default.
iTC 522339.31 GPS Corrections License Expired
Call your local GreenStar support number for license renewal.
iTC 522394.13 TCM not Calibrated
Calibrate TCM
iTC 522552.11 STARFIRE Network Fault
John Deere corrections network is not working. Wait for signal to become available again.
iTC 523187.02 Invalid License Activation received from StarFire Satellite
Invalid license code received.
iTC 523274.02 GPS Position Not Available
GPS signal is totally lost.
iTC 523309.07 Yaw Sensor Out Of Range
Vehicle course is not being corrected. Replace STARFIRE iTC receiver.
iTC 523309.16 Yaw Sensor Not Responding
Vehicle course is not being corrected. Replace STARFIRE iTC receiver.
iTC 523310.02 Memory Fault
StarFire memory error.
iTC 523319.18 Low Switched Voltage
Switched voltage below 8 VDC.
iTC 523348.07 TCM communication Failure
Inertial measurement unit communication failure
iTC 523348.12 TCM Sensor Failure
TCM sensor failure
iTC 523348.16 TCM Temperature out of Range
Reported IMU temperature is out of its calibrated range.
iTC 523441.31 No STARFIRE Height Dimension
Set height in TCM setup.
iTC 523442.31 No STARFIRE Fore/Aft Set
Set fore/aft in TCM setup or check SSU status.
iTC 523572.31 Power Shutdown Fault
Settings not saved from last shutdown. Check unswitched voltage.
iTC 523773.03 Vehicle CAN High Line Voltage High
Voltage above 4 VDC.
iTC 523773.04 Vehicle CAN High Line Voltage Low
Voltage below 1 VDC.
iTC 523774.03 Vehicle CAN Low Line Voltage High
Voltage above 4 VDC.
iTC 523774.04 Vehicle CAN Low Line Voltage Low
Voltage below 1 VDC.
iTC 523792.18 Low Unswitched Voltage
Unswitched voltage below 8 VDC.
iTC 524209.16 RTK Rover Too Far From Base Station
Indicates distance is over 16.9 km (10.5 miles) from base station.
iTC 524210.16 RTK Base Station Not Using Visible Satellites
RTK base station not using visible satellites.
iTC 524257.14 RTK Base Station Position Survey In Progress
Wait until survey is complete.
iTC 524257.16 RTK Base Station Relocation
Indicates base station moved greater than 20 meters.
LCR 523310.02 Memory Fault
Replace STARFIRE iTC receiver.

You might also like