You are on page 1of 11

AluSoft Electric

100% Electric
Electric design radiator alu

Instruction
and installation
The image refers to the 1500W model.

booklet
AluSoft Electric INDEX
100% Electric
Electric design radiator alu 1 Manufacturer's data page 2
2 Warnings and precautions page 3

Instruction and installation booklet 3 Assembly warnings page 4


4 Useful installation requirements page 5
5 Material present in the packaging page 5
6 Preparations for wall support page 5
7 Technical details page 6
8 Manual thermostat: how to use page 8
9 Special functions page 12
10 Supply of the product page 13
11 Certifications page 13
12 Warranty and assistance page 14
13 Towel rail installation and measures page 15

MANUFACTURER’S DATA
Dear Customer,
Thank you for choosing us. Before installing and / or using the product, please
read this manual carefully regarding installation, use and correct maintenance.

This radiator is commercialized by:


SOLAR NEDERLAND B.V.
Toermalijnstraat 7
1812 RL Alkmaar
Nederland
www.thermrad.eu

IMPORTANT:

We decline all responsibility in case of accidents caused by incorrect use of


the radiator which is not in line with the following instructions.

This radiator is strictly tested according to the regulations in force before


CAUTION!!! leaving the factory.

We disclaim all responsibility for any inaccuracies contained in this instruction We reserve the right to make any technical or constructive changes deemed
manual. necessary, without notice.
Customers are invited to check the material received before assembly or installation. The construction features of this radiator is patented.
1 2
WARNINGS AND PRECAUTIONS CAUTION!!!
Some parts of the product can reach a very high temperature and can cause
Read all the following warnings and precautions carefully. burns. Particular attention must be paid in presence of children and persons
with reduced physical, sensory or mental abilities.

WARNINGS AND PRECAUTIONS


Carefully read all instructions and measures
for proper radiator assembly.

CAUTION!!!
• Make electrical connections only after fixing the radiator to the wall.
• The radiator operates at 230V. Make sure the system voltage matches. • The fittings must be made only by qualified and experienced personnel and must
• The radiator belongs to class II and to the IPX4 electrical protection; do not apply any be made in compliance with the regulations in force using certified materials.
electrical connection ignoring these safety rules. • Do not attempt to disassemble the radiator body or electrical boxes.
• Make sure you have the necessary power indicated on the sign plate because the radiator If you have problems, contact your installer. The supplied cable is made specifically
works. for the application. Do not attempt to replace this cable with any other inappropriate
• This radiator is only intended for drying fabrics washed with water. cable.
• The radiator should not be placed immediately under a fixed socket. • In the power supply unit, in accordance with the installation rules, a device must
• If the power cable is damaged, it must be replaced by the manufacturer or its after-sales be provided that ensures the omnipolar disconnection of the electrical network,
service, or by a qualified person, in order to prevent all risks. with a contact opening distance, which allows the complete disconnection of the
• In the event of a fault, contact your dealer. Do not alter the product in any way. Any category conditions overvoltage III.
disassembly or any opening compromise the safety of the product. We do not accept • In case the radiator charge is higher than the data plate of the control or control
any responsibility for accidents resulting from any type of manipulation carried out on system (contact of thermostat or control switch), interpose a properly sized power
the electric device. release or counter.
• Do not intervene on the appliance during operation. • The power supply circuit of the appliance must be protected by a high sensitivity
• The protection system of this radiator is designed to prevent direct access to the electric differential protection device.
heating elements and must be kept in its position during use. • For appliances without plug, observe the following colors:
• The radiator may not be used by children under the age of 8 and by persons with reduced
physical, sensory or mental abilities, or by lack of experience or necessary knowledge,
provided they are supervised or after receiving the instructions for using the appliance.
and after understanding the dangers inherent to it.
• Children must not play with the appliance. Cleaning and maintenance intended for the
product must not be carried out by children without supervision.
• Children under 3 must be kept away from the appliance if they are not continuously
monitored
• Children aged between 3 and 8 years should only switch the appliance on / off under
conditions that it has been placed in the normal operating position provided that it
is supervised and has received instructions regarding safe use of the appliance and
L N B
potential hazards related to the use of the appliance.
• Children between the ages of 3 and 8 must not connect, adjust or clean the appliance or line (brown) neutral (blue or gray) fil pilot (black)
perform maintenance on the appliance.
• The electric radiator must be installed away from any contact with water and the control WARNING!
and electrical control devices must not be placed within reach of persons in bathtubs, The “FIL PILOT” is intended for radiators connected to the energy
showers or situations in contact with water. . management unit. If the black “FIL PILOT” cable is not used, the safety
• Before cleaning, make sure that the electric radiator is at room temperature and that the rules require it to be insulated and not connected to the cable from the ground.
circuit is disconnected.
• Clean with damp cloths without using aggressive or abrasive detergents that could
compromise the painting of the appliance.
• In models equipped with towel bar, do not load or hang excessive weights, the structure • Sectioning the cables is mandatory.
capacity is calculated to support a maximum of 2 kg. • All contacts must be separated by at least 3 mm.
• On models equipped with a towel bar, the minimum height from the ground of these • It is mandatory that the power supply system to which the regulator is connected
elements must not be less than 60 cm. has an extra-sensitive differential protection.
3 4
• In the bathroom, it can be installed in zone 3 (see figure 1) provided that the control
device can not be used by people while using the shower or bathtub. DATA SHEET
• The electric cable must be connected to an outlet or connection block, which must be at
least 25 cm away from the ground (without intermediate plugs for devices sold without
plugs.

Figure 1: Classification of the bathroom area

INSTRUMENTS NECESSARY FOR MOUNTING


• Star screwdriver (in case of use of supplied sockets)
• Drill;
• Wall drill D. 8 mm (If you use the plugs supplied).

Length of the side exit cable: 1.20 mt

MATERIALS CONTAINED IN THE PACKAGING


• 4 brackets for wall mounting
• 8 fische plugs for concrete, whole bricks, hollow bricks, compact stone.

SUPPORT PREPARATION
Fix the wall support in the opposite
Secure the radiator using the included fastening kit, the lower straight support direction to that of the other 3 to prevent
must be folded down and the hook must be pulled down using the adjusting screw the wall radiator from tipping over.
to lock the radiator.
5 6
DATA SHEET METHOD OF USE
OF THE CHRONOTHERMOSTAT
The internal thermostat has di erent operating modes, which can be selected
cyclically by pressing the MODE button.

According to the COMMISSION REGULATION


(EU) 2015/1188 of April, 28th 2015, the seasonal
energy of fixed electric local space
heaters with a rated thermal input of more than
250 W is not less than 38%.
MODEL AluSoft 1800/3 AluSoft 1800/4 In particular, the calculation formula:
Rated power 1500 W 2000 W η s = η s,on -10% + F (1) + F (2) + F (3) - F (4) - F (5)
Power supply 230V + / -10% 50Hz 1. Stand-by
with
Class of insulation CLASS II
2. Mode F (2) = 7.0%: with electronic control of the room
Degree of protection IPX4 temperature and weekly timer
F (3) = 1.0%: room temperature control with
Dimension L x H x D 355x1800x90 475x1800x90 3. + detection of open windows
Fixing hole LfxHf 152,5x1467 272,5x1467
4. – It results in:
Length / type η s = 40% - 10% + 7% + 1% = 38%
total lenght 2mt / 3x1 mmq
of electric cable
Operating service temperature 0 - 35°C
Storage temperature 0 - 50°C
Humidity 0 - 85 % without condensation

Microprocessor thermostat with weekly program,


Type of regulation
with open windows detection
Temperature regulation
7 - 35°C 1. STAND-BY
range
Certification
In STAND-BY mode, the radiator does not work.
Content of the 4 brackets for wall mounting - 8 fisher for concrete, The screen shows the real time in the clock section of the screen.
packaging whole bricks, hollow bricks, compact stone

* For towel rails installation and measures please read the final attached page To switch from STAND-BY mode to another operating

Features of the appliance top) and keep it pressed for 2 seconds.

IPX4: device protected from splashes of water. When you exit the stand-by mode, the last mode of
operation will be re-established and will appear on the
screen.
Class II: double insulation
7 8
2. PROGRAM MODE 4. COMFORT MODE
«INSIDE» has a programmable thermostat 24 / 24h and 7/7 days, The comfort program is set when the arrow on the left
the function is selected when the arrow relative to the clock indicates the sun symbol and the comfort temperature appears
symbol is SHOWN (the clock is at the bottom of the screen). on the screen.
In the clock section is shown the time of day while the daily program is In this operating mode the thermostat regulates the selected
shown on the left of the screen. temperature.
The SET temperature is visible on the screen.
To program the comfort temperature, use the + and - buttons.
To program the thermostat, please refer to the corresponding paragraph. The selected temperature is used both for the weekly program
In this operating mode, the thermostat regulates the temperature using
the comfort or the night reduction temperature, as programmed. temperature point
An arrow at the top of the screen indicates the actual mode
(comfort or night).

To change the comfort and night temperature, select the comfort or night
button (MODE, second from above), then use the + and - buttons to change
the temperature parameters.

3. “FIL PILOTE” MODE 5. NIGHT MODE

The night program is set when the arrow indicates the moon
arrow in the top left corner. A second arrow indicates the program mode symbol on the screen and the temperature for the night appears.
selected. In this operating mode the thermostat regulates the selected
temperature.
Fil Pilote command:
1) Comfort: set point = temperature of comfort mode. To program the night temperature, use the + and - buttons.
2) Nighttime reduction: set point = comfort -3.5 ° C The selected temperature is used both for the weekly program
3) ECO1: set point = comfort -1 ° C as the night temperature and for Fil Pilot mode as a night
4) ECO2: set point = comfort -2 ° C temperature point.
5) Antifreeze: Delivery point = 7 ° C
6) OFF: no temperature regulation, stand-by mode

NOTE:
To change the comfort and night temperature, select the comfort or night mode
using the MODE button, then use the + and - buttons to change the temperature
parameters.

9 10
6. ANTIFREEZE 8. SPECIAL FUNCTIONS

In antifreeze mode, the arrow indicates the ice symbol, a. SET HOURS AND DAY
and the antifreeze temperature, set at 7 ° C, appears on the The thermostat clock can only be changed from STAND-BY mode.
screen.
This mode of operation prevents the room from freezing, When in Stand-by mode please press the MODE button until
when the temperature is below 7°C. the clock is activated.
If you press the MODE button for a few seconds, the screen shown
below (SET) appears on the screen.
Adjust the clock by using the + and - buttons, press and hold
the button to change quickly.

and switch to adjust the day of the week by keeping the MODE
button pressed.
7. WEEKLY PROGRAMMING 24 /24 H AND 7/7 DAYS

To program the thermostat, select the program mode by using the MODE button
(second button from the top), until “PRO” appears on the screen.

Press the MODE button again for about 5 seconds, the letters FP (Programming
Function) will appear on the screen, and then the letters “PR” will allow you to access
the programming mode.
The message d1 (day 1) will appear on the screen and use the + and - buttons to change the time.
With the + button, the function will be activated at the desired time while it will stop during

and select the other days d2, d3 .... D7.

EXAMPLE:
Once you have entered d2, press the MODE key until
the word PRO appears for a few seconds and repeat
the above operation for D3.
b. OPEN WINDOW DETECTION

The function can detect the status of open windows, the function
is activated when the temperature drops QUICKLY (e.g. when a
window is open in the room).

When the status of the open window has been detected,


The day of the week and the hours to be programmed are displayed on the screen.
“OPn” (OPEN) appears on the screen and the radiator switches to
The lower screen indicates the time interval to program: use + to use the comfort
anti-freeze mode at 7 ° C.
temperature and - to use the night temperature. For each selection the time interval will
increase automatically.
The status ends automatically if the window is closed or by
To return to the day selection, press the MODE button.
pressing the thermostat MODE button.

Press the MODE button to save the weekly program at least 5 seconds until END appears.

11 12
DISPOSAL WARRANTY AND ASSISTANCE

The presence of a mobile container crossed out on the The aluminum alloy body is guaranteed against manufacturing defects
product indicates that within the European Union all electric for 10 years from the date of purchase.
and electronic products are subject to special collection at
the end of their life cycle. Do not dispose of these products The electrical and electronic components are guaranteed for 2 years from the
in unsorted municipal waste. date of purchase of the radiator.
The warranty is valid if the product remains intact, without any alteration or
At the end of the life of the product, the appliance can’t be modification.
disposed of in municipal solid waste but be delivered to a The warranty is valid from the date of sale.
special collection center in your region.
It is therefore necessary to keep the invoice or receipt to prove the date of
purchase.
The separate collection of electrical and electronic equipment
is an integral part of a policy of preservation, protection and
improvement of the quality of the environment; it is aimed Technical assistance
at avoiding potential harmful effects on human health due to
the presence of dangerous substances classified as such by For technical assistance, contact your installer.
European directives.
CAUTION !!!
For the validity of the warranty, the installation must comply with the standards
and laws in force and must be performed in a professional manner.

The manufacturer reserves the right to make changes to its products which it
deems necessary or useful without compromising the essential characteristics.
CERTIFICATION

This product is manufactured in accordance with the European directive:


Directive 2014/35/UE

In accordance with the harmonized standards:


- EN 60335-1:2012 + A11:2014 + A13:2017: Safety of household electrical
appliances and similar, general regulations.
- EN 60335-2-30:2009 + A11:2012: Safety of household electrical
appliances and the like, Part 2: special requirements for electric
radiators.
- EN 60335-2-43:2003 + A1:2006 + A2:2008: Safety of household
electrical appliances and the like, Part 2: Particular requirements for
drying machines and towel warmers.
- EN 62233:2008
- EN 55014-1: 2000 + A1: 2001 + A2: 2002
- EN 61000-3-2: 2000
- EN 61000-3-3: 1995 +A1: 2001
- EN 55014-2: 1997 + A1: 2001
- EN 61000-4-2: 1995 +A1: 1999 +A2: 2001
- EN 61000-4-4: 1995 +A1: 2001 +A2: 2002
- EN 61000-4-5: 1995 +A1: 2001
- EN 61000-4-6: 1996 +A1: 2001
- EN 61000-4-11: 1994 +A1: 2001

13 14
AluSoft Electric

TOWEL RAIL INSTALLATION AND MEASURES

For Thermrad AluSoft a single towel rail can be added.


The bar can be mounted at 900 mm from the bottom of the radiator.

For assembly, FIX the bar to the radiator USING a suitable screwdriver, inserting
the screws in the appropriate holes already repared on the radiator and the bar.

Towel rails measures:

For AluSoft 2 elements: 252*50 mm


For AluSoft 3 elements: 383* 50 mm
For AluSoft 4 elements: 504,5* 50 mm