Call drop Improvement Security Level: Internal

Call drop improvement case analysis

Summary: In country X, Project Y, during the bad cell KPI analysis, we find so many cells have high call drop rate. Customer has
given target to improve call drop. RNC level target was <1% for CS and Cell level call drop improvement target was <=1.5% CS and
<=5% for PS.

Alarm: before analysis we must check current alarm and alarm history, in my case I don’t find any alarm.

RTWP: RTWP checked and I found few sites having high RTWP but these sites have high traffic, RTWP get poor during the high
utilization only.

KPI analysis: - from the below KPI analysis, we can see that in my case mostly 3 counter is failed.

1- Call drop due to UL synchronization


2- Call drop due to Uu No reply
3- Call drop due to SRB reset

Solution: - Cell Level parameters

UL Syn. Solution: To solve this issue, we can change NINSYNCIND and NOUTSYNCIND parameter. Description is given
below:-

MML Command to change the Parameter MOD CELL


Script For Example
MOD UCELL: CELLID=XXXXX, NINSYNCIND=1, NOUTSYNCIND=100, TRLFAILURE=100;

NInsyncInd: Meaning of this parameter, no of times successive in-sync indications required for the Node-B to trigger the radio
link recovery process. Radio link set remains in the initial state until it has received a certain number (the number is defined by
NInsyncInd) of successive in-sync indications from L1, and then Node-B triggers the radio link recovery process, which indicates
that the radio link set has been synchronized. Once the radio link recovery process is triggered, the radio link set is considered to be
in the synchronized state. In the radio link maintenance process, NInsyncInd is used together with the successive out-of-sync
indication (NOUTSYNCIND) counter.

Meaning of Parameter: Higher the value is, the stricter the synchronization process becomes, and the more
difficult the synchronization occurs. The lower the value is, the easier the synchronization occurs. If the link quality is poor,
a simple synchronization requirement leads to waste of the UE power and increase of uplink interference.
Default Value: 5
Optimized Value: 1

NOutsyncInd: When the radio link set is in the synchronized state, the Node-B starts the timer after it receives successive out-
of-sync indications of the number defined by NOutsyncInd. The Node-B shall stop and reset the timer after receiving successive in-
sync indications of the number defined by NInsyncInd. When the timer expires, the Node-B triggers the radio link failure process,
and indicates which radio link set is out-of-sync.

Meaning of Parameter: If the value is excessively high, the link out-of-sync decision is likely to happen. If the
value is excessively low, out-of-sync is not likely to happen. But if the link quality is poor, it may result in a waste of the UE
power and increased uplink interference.
Default Value: 50
Optimized Value: 100
Call drop Improvement Security Level: Internal

TRlFailure: Radio link failure timer duration. When the radio link set is in the synchronized state, the Node-B starts the timer
after it receives successive out-of-sync indications of the number defined by NOutsyncInd. The Node-B shall stop and reset the
timer after receiving successive in-sync indications of the number defined by NInsyncInd. When the timer expires, the Node-B
triggers the radio link failure process, and indicates which radio link set is out-of-sync.

Meaning of parameter: If the value is excessively low, there are few chances for the radio link to get
synchronized. If the value is excessively high, the radio link failure process is probably delayed, and the downlink
interference increases.
Default Value: 50
Optimized Value: 100

Uu No reply:- This counter failed due to poor coverage, to improve this counter we can increase Max DL Radio Link Power for
CS & PS service depend upon requirement and condition of cell. Command to modify DL RL power is given below
For Example CS 12.2 call drop issue
MOD CELLRLPWR: CELLID=XXXXX, CNDOMAINID=CS_DOMAIN, MAXBITRATE=12200, RLMAXDLPWR=30,
RLMINDLPWR=-120;
Note:-RL max DL power can’t be smaller than RL min DL power, if value of this parameter is too much high then
downlink transmit power on a single radio link is too high that means downlink capacity will be affected. If value of this
parameter is set to low value then coverage area of services is decreased that means call drop may increased.

In my network current value was RLMAXDLPWR=0, changed to RLMAXDLPWR=30, after change value, I see the
improvement in the failure due to Uu Failed counter.

Solution: - RNC Level parameters


SRB reset: - During the call drop analysis you will find many call drop reason due to SRB reset or TRB reset.

Mainly SRB reset happened due to poor coverage or Missing Neighbor.

1) Missing Neighbor: if Neighbor cell not configured, from the IOS trace, we can see that it has the problem of Neighbor cell
not configured and drop call occurred easily.

From the IOS Trace, the uplink has been out of synchronization, and from the RRC_MEAS_RPRT, we can see that the downlink of
cell XXXX is bad, and the UE has reported the event of 1A, but from the RNC configuration file, we can’t find the neighbor cell XXXX
whose PSCRAMBCODE is XXX. Then we need to configure the missing neighbors.

2) Downlink bad for the cell XXXX, it has many times of SRB/TRB reset and UU No reply, we have collected the logs to analyze the
reason. There are many call drop procedures as below: After the UE goes to FACH then call drop occurred.
We can see that the UE want to go to the DCH, but From theRRC_MEAS_RPRT we can find the EC/NO is bad now which means t
hedownlink is bad, and the UE would not receive the message of RRC_RB_RECFG. Then the Call Drop occurred.
And from the RRC_MEAS_RPRT, we can’t see any other cells that the UE can detected.
Call drop Improvement Security Level: Internal

Mostly UL and DL interference create problem and call drop


happened. If our RSCP is greater than ±85dBm and Active set
EcIo is smaller than ±13 means call drop happened due to down
link interference. DL interference may be due to Pilot pollution,
when 3 cell’s meet the handover requirement in the coverage
area, the active set replaces the best or the best cell change due
to fluctuations of signals, when the comprehensive quality of
active set is bad (EcIo change around ±10 dB), handover failure
usually casus due the SRB reset or TRB reset. In case of
handover delay the possibility RSCP might be good but EcIo
might be weak but RSCP of EcIo cell in monitor set is good. So
we need to make sure there is no pilot pollution in highly call
drop cell area. For UL interference, we need to check RTWP if
RTWP is 10dBm greater than normal value ±105.9dBm. UL interference increase UE transmit power in connected mode, there over
high BLER cause SRB reset or TRB reset. UL interference either internal or external, most of senior UL interference you will find
due to external source.

Solution: - To improve call drop due to SRB reset we can modify the parameter NoDiscardMaxDAT value D25 (default) to
D40.Meaning of this parameter No-Discard PDU max TX, this parameter is applicable to only AM RLC entity, which is set to
NO_DISCARD, means maximum number of PDU transmission before RLC entity is rest, if mode is set to NO_DISCARD, the RLC
entity will be directly reset if the number of retransmission of PDU reach the value define by parameter. We can set this parameter at
larger value if BLER of transport channel is high. To make this parameter value effective make sure parameter AMRlcDiscardMode
is set to NO_DISCARD mode.

Procedure to modify the parameter:- command used to change is parameter is -


MOD UTYPSRBRLC: SRBINDEX=1, LOCHINDEX=1, DELAYCLASS=1, TRCHTYPE=TRCH_DCH,
OPPOSITETRCHTYPE=TRCH_DCH, RLCMODE=AM, AMRLCCFGPARA=EDIT_SENDER_PARA,
AMRLCDISCARDMODE=NO_DISCARD, NODISCARDMAXDAT=D40, TXWINDOWSIZE=D64, TIMERRST=D300,
LASTTXPDUPOLL=TRUE, LASTRETXPDUPOLL=TRUE, TIMERPOLLPROHIBIT=NOTUSED, TIMERPOLL=D200,
POLLPDU=NOTUSED, POLLSDU=D1, POLLWINDOW=D50, TIMERPOLLPERIODIC=NOTUSED,
CFGPOLLINGPARA=TRUE, POLLPDUFORENL2=D4, POLLSDUFORENL2=D4;

Another method is Call reestablishment Method to improve call drop:-

Call reestablishment is function by which radio links are reestablished when service interruption or access failure occurs due to
bad RF environment. Call reestablishment can be initiated by UE or RAN. In case of UE, UE send reestablishment request to
network to restore service after detection a downlink RL failure or SRB reset. In case of RAN, RAN informs the UE to start
reestablishment procedure. With the help of this feature, user experience will be rich, because RAB successes rate will be better
and call drop will get improved. There are mainly 4 reasons for call reestablishment after service get interruption.

1- DL Radio Link failure


2- UL radio Link Failure
3- SRB/TRB reset
4- UE SRB reset.
Call drop Improvement Security Level: Internal

As soon as RAN detects the service interruption or access failure, before release of Radio links, call reestablishment get started if
this feature is activated.

1- DL Radio Link Failure:-


UE continue monitor DL RL quality, if UE receives N313 Number
of OUT-SYNC indications, UE start T313 timer and if UE didn’t
receive N315 number of IN-SYNC indications within timer T313
So UE will send Cell Update message with cause value “Radio
Link Failure” to RNC and get inter in the call reestablishment
procedure. Otherwise UE will not send Cell Update message
to RNC.
Procedure:-Now UE will send Cell Update Message with
cause value “Radio Link Failure” to RNC for call
reestablishment. Meanwhile UE will start timer T314 for CS
service and T315 for PS service which is maximum allowed
time for UE to try to send Cell Update Message. UE can
resend Cell Update Message to network every T302 time and
for maximum number N302 times if UE didn’t get reply from
the Network. If Faulty Radio Links are restored before T314
(for CS)/T315 (for PS) timer gets expired, the call
reestablishment is successful, in this case services get
restored or UE access succeeds. If Faulty Radio Links are not
restored before T314/T315 timer get expired means service
are released or UE access fails.

2- UL Radio Link Failure:-


Node B monitors RL link quality and receives
NOUTSYNCIND number of “out –sync” indications. Node-B
start the TRIFailure timer if Node-B didn’t receive
NINSYNCIND “in-sync” indication within timer TRIFailure,
Node-B stops and reset the timer then RNC activate the
synchronization timer. If Node-B does not detect UL RL
Synchronization before Synchronization timer expires then
UL RL call reestablishment triggered.
Procedure: - RNC send Radio Link Activation command to
Node-B with Information Element “deactivate”, Node-B stop
downlink power transmission for UE’s Radio Link set. Now
RNC start timer for call reestablishment RSVDPARA2 timer
for CS service and RSVDPARA3 timer for PS service. If
RNC receives Cell Update Message from UE before timer
RSVDPARA2/3 get expired, then RNC stop the timer and
start call reestablishment and IF RNC receives Cell Update
message after timer get expired then call drop and UE
access failure occur.
Implementation:- After Node stop downlink power
transmission for a UE’s Radio links, UE will receive N313
number of Out-sync Indications, UE will start timer T313
and If didn’t receive N315 number IN-SYNC indication
within the timer get expire then UE will transmit the Cell
Update Message with cause Value “Radio Link Failure” to RNC for call
reestablishment. Meantime UE start T314/315 timer which is maximum
allowed time for UE to send the Cell Update Message to RNC. UE can
resend Cell Update Message to RNC if UE didn’t get the reply from Network
(RNC) every T302 time for Maximum number for N302 times. If Faulty
Radio links get restored before timer get expired T314/315 then Call
reestablishment is successful otherwise service get released or UE access
fails.
3- SRB rest: - as we Know in Huawei system, AMRLCDISCARDMODE
parameter is set to NO_DISCARD, RNC send a signaling message in AM( Ack Mode) to UE. Now RNC does not receive
the response from UE before the number of SRB RLC PDU retransmission reaches the value of NODISCARDMAXDAT
Call drop Improvement Security Level: Internal

parameter. RNC triggers an SRB reset and sends the reset PDU message to UE to reestablish RLC entities on both
sides. SRB reset call reestablishment procedure and implementation is same as UL RL failure.
4- UE SRB Reset:-
RNC does not send Radio Link Activation command message containing the Information Element (IE) “deactivation” to the
Node-B. Now Node-B does not stop downlink power transmission for the UE’s RL reset. Instead, RNC start call
reestablishment after receiving cell update message from UE. Process and implementation is same as UL RL failure.

Configuration for Call reestablishment:-

Switch parameters:-

Call reestablishment is controlled by service switch, Process switch and cause switch parameters. First we have to enable service
switch before enabling the process switch or cause switch.

Parameter Name Huawei Recommende Remark


default d value
value
Service switch RSVDBIT1_BIT24 Disabled Enabled Switch that controls call reestablishment for CS service (also for
combine CS+PS service)
RSVDBIT1_BIT25 Disabled Enabled Switch that controls call reestablishment for PS service
Cause switch RSVDBIT1_BIT22 Disabled Enabled Switch that controls call reestablishment triggered by SRB reset
RSVDBIT1_BIT23 Disabled Enabled Switch that controls call reestablishment triggered by RL failures.

Timer and counter parameters:-

Parameter name HUAWEI Recommende Remark


default Value d value
NOUTSYNCIND 50 8 Times of successive out-sync indications required for starting the
radio link failure timer
NINSYNCIND 5 8 Times of successive in-sync indications required for the Node-B
to trigger the radio link recovery process
TRIFailure 5 sec 3 sec Node-B starts the timer after it receives successive out-of-sync
indications of the number defined by NOutsyncInd. The Node-B
shall stop and reset the timer after receiving successive in-sync
indications of the number defined by NInsyncInd
rvsdpara1:RSVDBIT1_BIT2 1 0 Switch that controls Synchronization Timer for CS
8 reestablishment triggered, 1:RlRstrTmr,0:T313
RIRstr Tmr 11000msec 11000msec A timer to RNC wait for radio link restoration indication in the
radio link procedure
Rvsdpara2 0msec 15000msec CS Timer for Enhanced Call Reestablishment, start after RNC
send the RL Active CMD , stop after RNC receives cell update
message
Rvsdpara3 0msec 30000msec PS Timer for Enhanced Call Reestablishment, , start after RNC
send the RL Active CMD , stop after RNC receives cell update
Call drop Improvement Security Level: Internal

message
N313 50 20 Maximum number of successive "out of sync" indications
received from L1
N315 1 1 Maximum number of successive "in sync" indications received
from L1 when T313 is activated
T313 3 sec 3 sec T313 is started after the UE detects consecutive N313 "out of
sync“indications from L1. T313 is stopped after the UE detects
consecutive N315 "in sync" indications from L1
T314 0sec 12sec T314 is started when the criteria for CS radio link failure are
fulfilled and only radio bearers associated with T314 exist.T314
is stopped after the Cell Update procedure has been completed.
(must be greater than T302*N302)
T315 0sec 30sec T315 is started when the criteria for PS radio link failure are
fulfilled, and only radio bearer associated with T315 exists.T315
is stopped after the Cell Update procedure has been completed
(must be greater than T302*N302)
N302 3 3 Maximum number of retransmissions of CELL UPDATE/URA
UPDATE
T302 2000msec 1400msec CELL UPDATE/URA UPDATE will be resent upon expiry of the
timer if V302 less than or equal to N302

Note: -

1- If Call reestablishment feature already enabled in network then don’t change value NOUTSYNCIND, NINSYNCIND &
TRIfailure value as I have suggested at Page 1 & 2 for cell level call drop improvement.
2- After Call reestablishment feature enabled in the network you will see more signaling traffic than before the call
reestablishment feature enabled, reason behind is number of cell update message will get increase for the due to call
reestablishment feature activation.

Suggestion:- I suggest before implementing call reestablishment feature in the network, first we have to make sure that access
failure or Call drop is really happening due to RL failure or not. For this purpose need to analysis one or two days CHR/MR data
through OMSTAR and you will get to know how many Drop call or access failure happening due to UL Radio Link Failure, if this
value is much then suggest to Implement Call reestablishment feature otherwise No need.
Call drop Improvement Security Level: Internal

Method of analysis call drop reason by OMSTAR:-

For call drop analysis through OMSATR tool we need 3 kinds of data. 1- Engineering parameter, 2- Configuration data, 3 –CHR/MR
data. You have to put latest configuration data and CHR/MR data, you can take 1 day or 2 day CHR/MR data for call drop analysis.

After analysis of CHR


logs, you will get result
like below:-

DropCall_DueTo_ASU_TimeOut:-
For call drop improvement due to ASU (Active set Update) time out, we can change timer value as per given below-
MML command Parameter name Default value Recommended Value Remark
SET USTATETIMER HoAsuTmr 5000 10000 Improve the CDR due
to Drop call_Due
to_ASU_TimeOut
Parameter Understanding: HOAsuTmr, HO active set update response timer, A timer to RNC wait for response to active set update
in soft handover procedure. If in your network CDR Due to _ASU_TimeOut is more than you can increase value of this parameter as
per suggested.

DropCall_DueTo_Ul_Radiolink_Failure:- for this case we can implement Call reestablishment feature to Improve drop call rate,
complete study and procedure is given in the previous slides.

DropCall_DueTo_PHY_CH_RECFG(RLCC)_TimeOut,
DropCall_DueTo_PHY_CH_RECFG(HHO)_TimeOut :-
To improve the call drop due to Physical channel reconfiguration timer out we can modify the parameter HoPhychRecfgTmr as per
given below
Call drop Improvement Security Level: Internal

MML command Parameter name Default Recommended Remark


value Value
SET HoPhychRecfgTmr 5000 10000 Improve the CDR due to
USTATETIMER DropCall_DueTo_PHY_CH_RECFG(RLCC)_TimeOut

Parameter understanding: HoPhychRecfgTmr, HO Physical Channel reconfiguration timer, A timer to RNC wait for response to
Physical channel reconfiguration in hard handover procedure. If you found DropCall_DueTo_PHY_CH_RECFG(RLCC)_TimeOut is
high then you can increase this timer value from 5000 to 10000 and monitor the result if result is +ve then keep the value same
otherwise revert it back.

DropCall_DueTo_RB_RECFG(DCCC)_TimeOut, To improve these 3 counter we can modify the RB setup


DropCall_DueTo_RBrecfg(Periodic DRD)_TimeOut, and reconfiguration timers, as per detail given below
DropCall_DueTo_RBREL

MML command Parameter name Default value Recommended Value Remark


SET USTATETIMER RbSetupRspTmr 5000 10000 Improve the CDR
DueTo_RBsetup_TimeOut
SET USTATETIMER RbRecfgRspTmr 5000 10000 Improve the CDR
DueTo_RBrecfg_TimeOut
SET USTATETIMER RbRelRspTmr 5000 10000 Improve the CDR
DueTo_RBREL_TimeOut

Parameter understanding: 1- RbSetupRspTmr, Wait RB setup response timer, this is A timer to RNC wait for the RB
setup response from UE in the RB procedure, 2- RbRecfgRspTmr, Wait RB reconfiguration response timer, this is A timer used to
wait for the RB reconfiguration response from UE in the RB procedure, 3- RbRelRspTmr, Wait RB release response timer, this is A
timer to RNC wait for the RB release response from UE in the RB procedure. If you found call drop due to these 3 reasons in your
network you can change parameter value from 5000 to 10000, hopefully call drop will get improve.

DropCall_Dueto_MeasCtrl_No_Reply:- drop call due to measurement control_No_reply is under the case of poor
coverage. UE sends measurement to RNC but didn’t get reply from the RNC. This case I have already discussed in the previous
slides, we can change the Max RL DL power to improve the drop call.

Some other parameter or switch’s to improve the drop call rate.


CfgSwitch:-
Channel Configuration Strategy Switch, CFG_DL_BLIND_DETECTION_SWITCH, when the switch is on, the DL blind transport
format detection function is used for single SRB and AMR+SRB bearers. Note that the UE is only required to support the blind
transport format stipulated. But you may find some UE which will not support DL BLIND detection. But still we can make switch
enable to improve the drop call.

MML command Parameter name Default Recommend Remark


value ed Value
SET CFG_DL_BLIND_DETECTIO ON Some UE may not support DL blind
UCORRMALGOSWITCH N_SWITCH detection
Call drop Improvement Security Level: Internal

Some parameter for PS call drop:-

Need to check below PS inactive timers and optimize as per the suggested value

MML command Parameter name Default value Recommended Value Remark


SET UPSINACTTIMER PSINACTTMRFORCO 20 15
N
SET UPSINACTTIMER PSINACTTMRFORSTR 20 15
SET UPSINACTTIMER PSINACTTMRFORINT 20 15
SET UPSINACTTIMER PSINACTTMRFORBAC 20 15
Parameter Understanding:-
1- PsInactTmrForCon:- When detecting that the Ps' Conversational User had no data to transfer for a long time which longer
than this timer, the PDCP layer would request the RRC layer to release this RAB. If this parameter value set to very small
value then RNC will release the UE RAB that stop processing service this will saves network resources. But this will lead
to frequent RAB release and RAB assignment request, it will result as number of signaling message increase, CPU
loading increase. If parameter value set to larger value, RNC will hold Radio Links for that UE till timer get expire. This will
lead to waste network resources.
2- PsInactTmrForStr:- When detecting that the Ps' Streaming User had no data to transfer for a long time which longer than
this timer, the PDCP layer would request the RRC layer to release this Radio Access Bear. If this parameter value set to
very small value then RNC will release the UE RAB that stop processing service this will saves network resources. But
this will lead to frequent RAB release and RAB assignment request, it will result as number of signaling message
increase, CPU loading increase. If parameter value set to larger value, RNC will hold Radio Links for that UE till timer get
expire. This will lead to waste network resources.
3- PsInactTmrForInt:- When detecting that the Ps' Interactive User had no data to transfer for a long time which longer than
this timer, the PDCP layer would request the RRC layer to release this Radio Access Bear. . If this parameter value set to
very small value then RNC will release the UE RAB that stop processing service this will saves network resources. But
this will lead to frequent RAB release and RAB assignment request, it will result as number of signaling message
increase, CPU loading increase. If parameter value set to larger value, RNC will hold Radio Links for that UE till timer get
expire. This will lead to waste network resources.
4- PsInactTmrForBac:- When detecting that the Ps' Background User had no data to transfer for a long time which longer
than this timer, the PDCP layer would request the RRC layer to release this Radio Access Bear. If this parameter value set
to very small value then RNC will release the UE RAB that stop processing service this will saves network resources. But
this will lead to frequent RAB release and RAB assignment request, it will result as number of signaling message
increase, CPU loading increase. If parameter value set to larger value, RNC will hold Radio Links for that UE till timer get
expire. This will lead to waste network resources.

Suggestion:- I have tried to describe the all the case which I faced during my project work. I hope this document will help
you to solve the drop call issue. I suggest , before change the parameter , make proper Change request and take
approval from Technical director , supervisor , customer etc. also make sure parameter change doesn’t no impact at live
network if have impact at live network then change only in night time during wee hours only.