Professional Documents
Culture Documents
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
A
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Project/Order Number : 347797 (737079), 347798 (737772), 347799 (737074), 347805 (051508-02), 347806 (101132-02)
Customer/Yard Name : Eastern Pacific Shipping Pte Ltd
C
Hull Number : 403C (Lake Kivu), 404A (Lake Superior), 403A (Lake Taupo), 404D (Triumph), 404F (Lake Como)
Oil Fired Boiler Type : Scrubber Interface Panel - Safety
Oil System : N/A
Oil Type : N/A WHR Type 1: None
Burner Type & Size : KBO-R 14M WHR Type 2: None
D
Norm / Standards / Class Society : ABS Type Of Enclosure : Indoor Use Boiler Plant Enclosure(s), See IP Grade
Compliance : ABS Fabrication Year : See Enclosure Sign For Details
Rated Voltage / Frequency : 440VAC/60Hz Degree Of Protection : IP54
Rated Current : See "Main Power" page EMC - Environment : Makers Standard
E
Protection Device : Main Switch Board, Overcurrent Protection Max. Ambient Temperature : 45ºC
Earth System : ABS Panel Dimension H x W x D : 1000x1000x300
Rated Control Voltage : 230VAC/24VDC Local Control Panel Colour : n/a
Rated Short-Circuit Max. : See Enclosure Sign For Details Power Panel Colour : RAL7035
Rated Short-Circuit Min. : See Enclosure Sign For Details Cables : See Cable Connection Diagrams/Drawings
F
Page: 2
Master Versions: Title page / cover sheet =
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 +
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 5
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Table of contents TableOfContentsALTC_Rev1
&GR/5 Table of contents Table of contents : &GR/2 - =SI+L25&Cable Connection/2.b 27/08/2019 DKAAHOD
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
&GR/5.a Table of contents Table of contents : =SI+L25&Cable Connection/2.c - =SI+L25&Cable Connection/2.e 27/08/2019 DKAAHOD
&Revision Report/1 Revision overview Revision overview : =SI+L25&SCH/4 - =SI+L25&SCH/4 27/08/2019 DKAAHOD
=SI+L25&SCH/1 Graphic Boiler Scrubber Interface Panel Information & Off-Standard issues 19/02/2019 Dkaaabh
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
2 Page: 5
Master Versions: Table of contents : &GR/2 - =
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 =SI+L25&Cable Connection/2.b +
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 5.a
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Table of contents TableOfContentsALTC_Rev1
=SI+L25&Cable Connection/2.d Cable-connection diagram Cable-connection diagram =SI+L25-W24 =SI+L25-W25 27/08/2019 DKAAHOD
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
5 Page: 5.a
Master Versions: Table of contents : =SI+L25&Cable =
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 Connection/2.c - =SI+L25&Cable +
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
Connection/2.e 105X03: 092144 &Revision Report/1
Next Page:
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Revision overview Revision Form 1_Rev1
Revision name Revision comment Reason for revision change Page name Revision description Creator Date
A
&GR/5.a Page: 1
Master Versions: Revision overview : =SI+L25&SCH/4 - =
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 =SI+L25&SCH/4 +
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page:=SI+L25&SCH/1
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
A
Scrubber Interface (SI) Panel
Additional Information
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
C Condensator
Setpoints: L3 L2 L1 L2 L1 L3
L3 L2 L1
Setpoints For Motor Protection
Shall be Set To Operation Current (In) Component Type
Maximum Setpoint Is 110%
G *To Be Checked/Corrected By Customer Component No.
**Seen At The Shaft Driving End Of The Motor
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
A
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
NB. Colour identification using combination of those colours listed above may be used
For safety reasons, the colour Green or the colour Yellow may not be used except in the bicolour combination Green and Yellow (PE)
1 Page: 2
Master Versions: Wire Colours = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 3
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
B
Mounting brackets S2 EMG. Operation Scrubber Key Switch
1000 mm
A
10 mm
S2 S1 g en
er
Em
cy
S t o p
C
Q0
85 mm
R
300 mm
8
m
m
E
1000 mm
BOTTOM VIEW
F
300 mm
G
2 Page: 3
Master Versions: Panel Overview Front & Side View = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 4
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
3
DKAAHOD
25/07/2019
0
=MSB+
2
1
BOARD
P: 2 kW
Project
U: 440 V
4
3
JLE
Created By
2
19-Feb-2019
-Q3
Master Versions:
4A
-F8
-T3
1000 VA
440/230 V
44 42
I>
2
1
3
1
1/L1
2/T1
4
I>
4
3
3/L2
4/T2
45
I>
4
2
5/L3
6/T3
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
Power Supply
7
105X03: 092144
8
Pages of:
Next Page:
9
Page:
4
42
10
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
4
DKAAHOD
25/07/2019
0
+PF
4.4 /
4.4 /
N_A
L_A
-S1
12
11
Project
N
22
21
Created By
2
19-Feb-2019
L
2
1
1~
Master Versions:
2A
-F1
-M1
104 103
4
2
1
2
1
1~
104
104
4
3
Ventilation Fan
2A
-F2
1L
5
2
1
1N
4
3
1N
-X1
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
1L-X1 2 1L
1 1N
Internal
230 VAC Supply
1L / 33.0
1N / 33.0
6
Power Supply
2A
-F3
2L
7
2
1
2N
4
3
-X1
-X1
4 2L
3 2N
External
230 VAC
2L / 28.0
2N / 28.0
105X03: 092144
8
Pages of:
Next Page:
9
L / 11.0
N / 11.0
42
11
Page: 10
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), L
10.9 / L
N
10.9 / N
A
N
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
1 3
-F4
2A 2 4
112
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
112
B
111
E1+
112
E1+
113
PE
E1+
230VAC/24VDC 5 A PWM
C
120W
OUTPUT Adjust
OUTPUT LOW
OUTPUT OK
CP-E 24/5.0
L+ L+ CP-E 24/5.0 DELAY I_OUT I_OUT I_OUT I_OUT
1,5 2 1,5 2 1,5 2 1,5 2
..
A B 1 2,5 1 2,5 1 2,5 1 2,5
↑
0,5 3 0,5 3 0,5 3 0,5 3
E1+
E1+ 0 3A 3A 3A 3A
CONTROL LOGIC
only if the relay
module is missing
0VDC
RESET
OUTPUT
on the Siemens 14 12 11 RST
0V
(1)
0V
(2)
1 2 3 4
E
control power
module
E11
E21
E31
E41
0VDC
0VDC
F
24 VDC -Selectiviti module
-A64:8
10 Page: 11
Master Versions: Pilot Voltage = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 12
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
-A0
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
PLC/CPU
/13.1
BA 2xFC
CPU PLC
CPU XXXXXX-XX-X
A
R/S ER MT
X1P1R X1P2R
PROFINET (LAN)
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
X1P3
PROFINET
(LAN)
yyyyyxxxxxyyyyyy
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
LK1
B LK2 ALTC PLC
LK3
PWR
RUN
MAC ADDRESS
-A0:LAN1 STOP
MRES
-A0:LAN2
NB. Cat.6 Ethernet Cable Required
X80
For Cable Connection
24VDC
See also Page: Ethernetswitch
C
X50 & External Components
PUSH
1L+ 1M
2L+ 2M
IO
-A60 Interface +PF
/13.5 RJ-45
D
-U0 X1:P1
Bus Adapter
Interface
Module
DIAG
-A1:LAN1
-A1:LAN2
PWR
HMI On Front
F
11 Page: 12
Master Versions: Network Topologi/Overview = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 13
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
-A0 -A60 -A61 -A62 -A63 -A64 -A65 -A66 -A67 -A68
A
X1P1R X1P2R
PROFINET (LAN)
X1P3
PROFINET
(LAN)
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
yyyyyxxxxxyyyyyy
LK3
PWR PWR CC03 PWR CC00 PWR CC02 PWR CC02 PWR CC00 PWR CC00 PWR CC00
PWR
RUN
1 2 1 2 1 2 1 2
STOP 1 2 1 2 1 2
MAC ADDRESS
MRES
C 3 4 3 4 3 4 3 4
3 4 3 4 3 4
5 6 5 6 5 6 5 6
5 6 5 6 5 6
X80
7 8 7 8 7 8 7 8
24VDC
7 8 7 8 7 8
X50 9 10 9 10 9 10 9 10
9 10 9 10 9 10
11 12 11 12 11 12 11 12
PUSH
11 1211 1211 12
1L+ 1M
13 14 13 14 13 14 13 14
1 1 1 1 1 1
15 16 15 16 15 16 15 16 L N L N L N
2 2 2 2 2 2
L+ M L+ M L+ M L+ M L N L N L N
2L+ 2M
D
AI4(I) 2 AQ DI8 DI8 RQ4 RQ4 RQ4 END
12 Page: 13
Master Versions: PLC CPU & IO Overview = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 14
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
13
14.3 /
11.8 /
DKAAHOD
E3+
0VDC
25/07/2019
0
/13.1
-A0
1
Project
See Title Page
-X1/P3
-X80
1
1
1M
TD
JLE
Created By
-X1/P3
-X80
2
2
1M
2
TD_N
ALTC CPU - Xyyy
-X1/P3
19-Feb-2019
-X80
0VDC
3
RD
2L+
-X1/P3
-X80
6
3
1L+
RD_N
Ethernet
Ext Mem
Master Versions:
0VDC / 14.0
4
-X1:P2
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
PLC - A0
-X1/P2
-X1/P1
1
1
TD
TD
-X1/P2
-X1/P1
2
2
LAN1
TD_N
TD_N
7
-X1/P2
-X1/P1
3
3
RD
RD
-X1/P2
-X1/P1
4
4
RD_N
RD_N
105X03: 092144
8
Pages of:
Next Page:
9
LAN1 / 16.0
42
15
Page: 14
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
14
15.6 /
11.7 /
DKAAHOD
E2+
0VDC
25/07/2019
0
/13.5
-A60
0VDC
1L+
(PP1)
Module
1M
Remote IO
Project
2M 152
JLE
/13.5
-A61
Created By
152
151
2
L+
AI4(I)
Module
152
M-
19-Feb-2019
Analog Input
0VDC
153
1L 2L
RQ4
Module
0VDC
Master Versions:
Digital Output
154
1N 2N
153
/13.7
-A66
4
154
153
155
1L 2L
154
Digital Output
0VDC
1N 2N
155
/13.8
-A67
5
155
0VDC
1L 2L
RQ4
Module
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
Digital Output
1N 2N
0VDC
6
0VDC / 15.0
7
105X03: 092144
8
Pages of:
Next Page:
9
42
16
Page: 15
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
15
11.5 /
14.9 /
11.9 /
DKAAHOD
LAN1
E4+
0VDC
25/07/2019
0
Project
See Title Page
-X80:+ -X80:-
JLE
X80 - Power Supply
0VDC
Created By
LAN1
2
0VDC / 24.0
19-Feb-2019
-PE
-PE
Master Versions:
LAN1
-X1:P1
X1 - Profinet (LAN)
4
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
105X03: 092144
8
Pages of:
Next Page:
9
42
17
Page: 16
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
16
DKAAHOD
25/07/2019
1
/13.5
-A61
UV0
9
Project
See Title Page
2I0+
13
JLE
Created By
3
UV1
10
19-Feb-2019
2I1+
/24.6
14
Pressure In
Uptake Control
UV2
11
Master Versions:
15
5
UV3
12
1I0+
/24.1
1
Pressure In
Uptake Safety
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
1I1+
2
7
1I2+
/25.1
3
1I3+
/26.7
4
Panel
Burner Load Temperature
8
1I0-
105X03: 092144
9
1I2-
/25.1
7
= SI
+ L25
Pages of:
Next Page:
10
42
18
Page: 17
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
17
DKAAHOD
25/07/2019
1
/13.6
-A62
Q0+
/27.1
1
Project
Boiler/VFD
Speed Control
JLE
Created By
3
Q1+
/27.5
2
19-Feb-2019
Q1-
6
RES
3
RES
Master Versions:
7
5
RES
9
RES
13
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
RES
15
7
RES
4
RES
8
8
RES
105X03: 092144
9
RES
14
= SI
+ L25
Pages of:
Next Page:
10
42
19
Page: 18
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
18
/13.6
-A63
DKAAHOD
25/07/2019
1
DI0
/28.1
1
OK to start (E1)
DI1
/28.5
2
Project
DI2
/29.1
3
JLE
Created By
DI3
/29.3
4
Open (E4)
3
Damper (K66)
19-Feb-2019
DI4
/28.7
5
(E2)
Stop Burner
DI5
/29.7
6
Open (E6)
Damper (K65)
Master Versions:
DI6
/30.1
7
VFD
Fault/Overload
5
DI7
/30.3
8
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
10
7
M
11
M
12
M
13
M
14
105X03: 092144
9
= SI
+ L25
Pages of:
Next Page:
M
10
16
42
20
Page: 19
1 2 3 4 5 6 7 8 9 10
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
A
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
B
-A64 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
/13.6 DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 M M M M M M M M
/31.1 /31.3 /31.5 /32.1 /32.3 /32.5 /32.7 /11.3
Burner Running Fuel Supply Fuel Supply Fuel Supply Fuel Supply 24 VDC
Oil Fired Boiler Oil Valves Open Burner In From Tank 1 From Tank 2 From Tank 3 From Tank 4 -Selectiviti
Start/Stop (B1) (B3) Shutdown (B4) (B5) (B6) (B7) (B8) module
19 Page: 20
Master Versions: Scrubber Panel - PLC A64 DI = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 21
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
20
DKAAHOD
25/07/2019
1
/13.7
-A65
RQ0+
/33.1
1
Start/Stop
Project
Boiler (B1)
JLE
5
Created By
3
RQ1+
/33.2
2
19-Feb-2019
Boiler In
Shutdown (B4)
RQ2+
/33.3
3
Master Versions:
Start VFD
5
RQ2-
/33.3
7
Outlet
F253 Burner 2
(B3)
Oilvalves Open
Burner Running
6
RQ3-
/33.4
8
Outlet
F253 Burner 2
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
1L
9
1L
RES
7
2L
2L
11
RES
1N
8
RES
2N
12
2N
RES
105X03: 092144
9
Pages of:
Next Page:
10
42
22
Page: 21
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
21
DKAAHOD
25/07/2019
1
/13.7
-A66
RQ0+
/33.5
1
(B5)
Project
Fuel Supply
From Tank 1
JLE
5
Created By
3
RQ1+
/33.6
2
(B6)
19-Feb-2019
Fuel Supply
From Tank 2
RQ2+
/33.7
3
(B7)
Master Versions:
Fuel Supply
From Tank 3
5
RQ2-
/33.7
7
(B8)
Fuel Supply
From Tank 4
6
RQ3-
/33.8
8
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
1L
9
1L
RES
7
2L
2L
11
RES
1N
8
RES
2N
12
2N
RES
105X03: 092144
9
Pages of:
Next Page:
10
42
23
Page: 22
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
22
DKAAHOD
25/07/2019
1
/13.8
-A67
RQ0+
/34.1
1
Project
Stop Burner
JLE
5
Created By
3
RQ1+
/34.2
2
Burner
19-Feb-2019
Shutdown
RQ2+
/34.3
3
Warning
Master Versions:
5
RQ2-
/34.3
7
Alarm
6
RQ3-
/34.4
8
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
1L
9
1L
RES
7
2L
2L
11
RES
1N
8
RES
2N
12
2N
RES
105X03: 092144
9
Pages of:
Next Page:
10
42
24
Page: 23
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
/17.6 /17.4
-A61 -A61
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
1 5 14
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
-A61:13
-A61:5
B
-U1 -U4
/36.1
/36.1 PR4116 + PR4501 PR4114
11 12
44 43 31 33 44 43 11 12 31 33
C
-A61:14
243
242
241
242
244
245
E1+ E1+ E1+
11.6 / E1+ E1+ / 26.0
-W27
-W11
F
=OFB+ =EGCS+
+ -
-K61
EGCS
27 28
PRESSURE
TRANSMITTER
23 Page: 24
Master Versions: Control - Analog Input - Uptake = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 Pressure Safety and Control + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 25
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
24
DKAAHOD
25/07/2019
0
=OFB+
LCP
-X8
-A61:3
1
3
-A61
/17.7
1I2+
1
5
Project
-A61:7
Burner Load
1I2-
7
2
6
JLE
Created By
2
19-Feb-2019
Master Versions:
4
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
7
105X03: 092144
8
Pages of:
Next Page:
9
42
26
Page: 25
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), E1+ E1+
24.9 / E1+ E1+ / 27.0
/17.8
-A61
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
1I3+ 1I3-
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
4 8
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
B
-U2
Temperatur Converter
-A61:4
-A61:8
Input Output Supply
1 2 3 4 5 6 7 8
261
261
-A61:4
261
-A61:8
C
-A61:4
-A61:8
Dipswitch Settings
Output Dip S1 4 5 6
0-20mA
4-20mA
0-10V
2-10V
E
0-5V
1-5V
Temperature Converter
Panel Temperature
G
NB. Installation In The Upper
Part Of The Power Panel
Minimum 2cm Space To Other Components
25 Page: 26
Master Versions: Control - Analog Input - Panel = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 Temperature + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 27
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
26
26.5 /
26.5 /
DKAAHOD
E1+
0VDC
25/07/2019
0
Q0+
1
-A62
/18.2
Project
-A62:5
Speed Control
Q0-
5
-IE
JLE
E1+
Created By
273
0VDC
2
-X8
7a
19-Feb-2019
8a
-IE
-U3
E1+
+31
33-
Master Versions:
4
-W18
EGCS
-X8
271 -A62:2
5
12
43
(B2)
2
-A62
Q1+
/18.3
1
9
272 -A62:6
11
42
Q1-
For EGCS)
6
2
10
Burner Load
Burner Load to EGCS
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
-IE
0VDC
Pages of:
Next Page:
9
0VDC / 28.0
42
28
Page: 27
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
1 2 5
-A63:2
-A63:1
-A63:5
22 24
-K5
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
12 14 /29.8 21 12 14
Damper (K65) Open
B -K1 (E6) -K2
/28.2 11 /28.8 11
282
+PF 13
-S2
EMG. Operation 14
Scrubber
0-1
283
D
281
283
A1 A1
-K1 -K2
230VAC A2 230VAC A2
2L 2L 2L
10.8 / 2L 2L / 29.0
2N 2N
10.8 / 2N 2N / 29.0
E -X8 11 12 -X8 13 14
-W19
F
=EGCS+
EGCS 3 4
14 11 /28.1 14 11 /28.7
E1 12 12
24 24
22 21 22 21
34 34
32 31 32 31
44 44
42 41 42 41
G
OK to start EMG. Operation Stop Burner
(E1) EGCS (I1) (E2)
27 Page: 28
Master Versions: Control - Digital Input - EGCS = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 29
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Damper (K66) Closed (E3) Damper (K66) Open (E4) Damper (K65) Open (E6)
A
3 4 6
-A63:3
-A63:4
-A63:6
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
12 14 12 14 12 14
B -K3 -K4 -K5
/29.2 11 /29.4 11 /29.8 11
292
294
D
291
292
294
A1 A1 A1
-K3 -K4 -K5
230VAC A2 230VAC A2 230VAC A2
2L 2L 2L 2L
28.9 / 2L 2L / 30.0
2N 2N 2N 2N
28.9 / 2N 2N / 30.0
-W22 -W23
F
=EGCS+ =EGCS+
EGCS 7 8 EGCS 11 12
G
Damper (K66) Closed Damper (K66) Open Damper (K65) Open
(E3) (E4) (E6)
28 Page: 29
Master Versions: Control - Digital Input - EGCS = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 30
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
29
29.9 /
29.9 /
29.9 /
DKAAHOD
2N
2L
0VDC
25/07/2019
0
2L
0VDC
-X8
301 -A63:7
6
1
DI6
7
-A63
/19.5
11
12 14
22
2N
Project
See Title Page
VFD Fault/Overload
301
JLE
Created By
42
44
32
34
22
24
12
14
230VAC
-K6
2L
301
2
A2
A1
41
31
21
0VDC
11 /30.1
19-Feb-2019
-X8
23
/30.4
-K7
DI7
8
-A63
/19.5
11
12 14
24
2N
VFD Running
Master Versions:
302
42
44
32
34
22
24
12
14
230VAC
-K7
302
4
A2
A1
41
31
21
11 /30.3
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
2L
6
0VDC
2N
105X03: 092144
8
Pages of:
Next Page:
9
2L / 31.0
2N / 31.0
0VDC / 31.0
42
31
Page: 30
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Oil Fired Boiler Start/Stop Burner Running Oil Valves
(B1) Open (B3) Burner In Shutdown (B4)
A
1 2 3
-A64:1
-A64:2
-A64:3
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
12 14 12 14 12 14
B -K8 -K9 -K10
/31.2 11 /31.4 11 /31.6 11
312
313
D
311
312
313
A1 A1 A1
-K8 -K9 -K10
230VAC A2 230VAC A2 230VAC A2
2L 2L 2L 2L
30.9 / 2L 2L / 32.0
2N 2N 2N 2N
30.9 / 2N 2N / 32.0
F
=OFB+ =OFB+ =OFB+
LCP 3 4 LCP 5 6 LCP 7 8
G
Oil Fired Boiler Burner Running Burner In Shutdown (B4)
Start/Stop (B1) Oil Valves Open (B3)
30 Page: 31
Master Versions: EGC System 1 - Interface DI = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 32
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Fuel Supply From Tank 1 Fuel Supply From Tank 2 Fuel Supply From Tank 3 Fuel Supply From Tank 4
(B5) (B6) (B7) (B8)
A
4 5 6 7
-A64:4
-A64:5
-A64:6
-A64:7
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
12 14 12 14 12 14 12 14
B -K11 -K12 -K13 -K14
/32.2 11 /32.4 11 /32.6 11 /32.8 11
0VDC
0VDC 0VDC 0VDC 0VDC
C 31.9 / 0VDC
322
323
324
D
321
322
323
324
A1 A1 A1 A1
-K11 -K12 -K13 -K14
230VAC A2 230VAC A2 230VAC A2 230VAC A2
2L 2L 2L 2L
31.9 / 2L 2L /
2N
2L
2N 2N 2N 2N
31.9 / 2N 2N /
-W5 -W6
F
=OFB+ =OFB+
PP 9 10 PP 11 12
G
Fuel Supply Fuel Supply Fuel Supply Fuel Supply
From Tank 1 (B5) From Tank 2 (B6) From Tank 3 (B7) From Tank 4 (B8)
31 Page: 32
Master Versions: EGC System 1 - Interface DI = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 33
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
Start/Stop Boiler (B1) Boiler In Shutdown (B4) Start VFD Burner Running Oilvalves Open (B3) Fuel Supply From Tank 1 (B5) Fuel Supply From Tank 2 (B6) Fuel Supply From Tank 3 (B7) Fuel Supply From Tank 4 (B8)
RQ0+ RQ0- RQ1+ RQ1- RQ2+ RQ2- RQ3+ RQ3- RQ0+ RQ0- RQ1+ RQ1- RQ2+ RQ2- RQ3+ RQ3-
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
1 5 2 6 3 7 4 8 1 5 2 6 3 7 4 8
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
1L 1L 1L 1L 1L 1L 1L 1L 1L
10.6 / 1L 1L / 34.0
B
-A65:1
-A65:2
-A65:4
-A65:4
-A66:1
-A66:2
-A66:3
-A66:4
C
A1 A1 A1 A1 A1 A1 A1 A1
-K15 -K16 -K17 -K18 -K19 -K20 -K21 -K22
230VAC A2 230VAC A2 230VAC A2 230VAC A2 230VAC A2 230VAC A2 230VAC A2 230VAC A2
1N 1N 1N 1N 1N 1N 1N 1N 1N
10.6 / 1N 1N / 34.0
G
Start/Stop Boiler Boiler In Shutdown Start VFD Burner Running Fuel Supply Fuel Supply Fuel Supply Fuel Supply
(B1) (B4) Oilvalves Open From Tank 1 From Tank 2 From Tank 3 From Tank 4
(B3) (B5) (B6) (B7) (B8)
32 Page: 33
Master Versions: EGC System 1 - Interface DQ = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 34
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
1 5 2 6 3 7 4 8
1L
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
1L 1L 1L 1L
33.9 / 1L 1L /
B
-A67:1
-A67:2
-A67:3
-A67:4
C
A1 A1 A1 A1
-K23 -K24 -K25 -K26
230VAC A2 230VAC A2 230VAC A2 230VAC A2
1N
1N 1N 1N 1N
33.9 / 1N 1N /
G
Stop Burner Shutdown Burner Warning Alarm
33 Page: 34
Master Versions: EGC System 1 - Interface DQ = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 35
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
A
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
3511
3513
351
353
355
357
359
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
12 14 12 14 12 14 12 14 12 14 12 14 12 14
B -K15 -K16 -K18 -K19 -K20 -K21 -K22
/33.1 11 /33.2 11 /33.4 11 /33.5 11 /33.6 11 /33.7 11 /33.8 11
3511
3513
351
353
355
357
359
3510
3512
3514
352
354
356
358
D
-W24
=EGCS+
EGCS 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Start/Stop Boiler Burner Running Fuel Supply Fuel Supply Fuel Supply Fuel Supply
Boiler 1 In Shutdown Oilvalves Open From Tank 1 From Tank 2 From Tank 3 From Tank 4
G
(B1) (B4) (B3) (B5) (B6) (B7) (B8)
34 Page: 35
Master Versions: EGC System 1 - Potential Free to EGCS = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 36
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
0 1 2 3 4 5 6 7 8 9
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
A
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
3610
361
364
366
368
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
24 32 34 12 14 12 14 12 14
B -U1 -K5 -K23 -K24 -K17
/24.1 23 /29.8 31 /34.1 11 /34.2 11 /33.3 11
HIGH HIGH Damper (K65) Open Stop Burner Shutdown Burner Start VFD
PRESSURE IN UPTAKE (E6)
362
22
C -U1
/24.1 21
3610
361
364
366
368
LOW LOW
PRESSURE IN UPTAKE
3611
365
367
369
363
-W16 -W9
=OFB+ =OFB+
LCP 9 10 11 12 13 14 15 16 17 18 19 20
PP 17 18 19 20 21 22
HW Shutdown Damper K(65) Open Stop Burner Shutdown Burner Start VFD
(in safety circuit for OFB) (Need this signal to (External Stop) (External Shutdown)
G
oprate Boiler in Emergency)
35 Page: 36
Master Versions: EGC System 1 - Potential Free to LCP 1 = SI
DKAAHOD Alfa Laval Aalborg Project Drawing No.:
Revision 2 See Title Page JLE 19-Feb-2019 + L25
25/07/2019 Drawing Template Vers.: ALTC Scrub. Inter. Panel Rev.0 Gasvaerksvej 21
105X03: 092144 Next Page: 37
9000 Aalborg DK
Revision No. Rev. Made by/Date Approved by/Date Project Created By Creation Date EEC Version: Pages of: 42
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
36
DKAAHOD
25/07/2019
0
=AMS+
-AMS
/34.3
Warning
-K25
-W25
1
11
12 14
75
1
Warning
371
Project
371
JLE
Alarm
/34.4
-K26
Created By
-X8
374 373
3
11
12 14
77
Alarm
2
373
373
4
78
19-Feb-2019
-X8
6
80
Master Versions:
-X8
7
81
4
8
82
9
83
5
10
84
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
7
105X03: 092144
8
Pages of:
Next &Cable
9
Page: Connection/2
42
Page: 37
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
External targets Internal targets
&SCH/37
DKAAHOD
25/07/2019
0
P: 133 kW
=SI+L25-W0
Project
2
JLE
Switch Board
4
Created By
Cable-connection diagram
4
3
3
2
19-Feb-2019
conductor
=OFB-LCP -X8
Master Versions:
3
25
25
&SCH/25.1
4
26
26
4
conductor
=OFB-PP -X8
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
9
31
31
&SCH/32.1
10
32
32
6
=SI+L25-W6
=SI+L25-W6
=SI+L25-W4 =SI+L25-W5
7
conductor
=OFB-PP -X8
Cable-connection diagram =SI+L25-W0
11
33
33
11
&SCH/32.1
12
34
34
105X03: 092144
8
Pages of:
27/08/2019
Next Page:
9
DKAAHOD
Ala_Std_Cable_ConForm_ALTC_External_Rev3
Page:
2
42
2.a
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
2
External targets Internal targets
DKAAHOD
25/07/2019
0
=SI+L25-W9
=OFB-PP
Project
17
69
69
JLE
19
71
Created By
Cable-connection diagram
69
17
2
20
72
21
73
19-Feb-2019
22
74
=SI+L25-W11
Master Versions:
Pressure In Uptake Safety
conductor
=OFB-K61 -X8
4
1
1
+
1
&SCH/24.1
PRESSURE
TRANSMITTER -IE
5
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
Burner Load
=SI+L25-W13
6
conductor
=EGCS-EGCS -X8
27
53
53
53
27
&SCH/24.4
28
54
54
7
=SI+L25-W11 =SI+L25-W13
-IE
Cable-connection diagram =SI+L25-W9
=OFB-LCP -X8
1
5
5
105X03: 092144
8
&SCH/25.1
2
6
6
-IE
= SI
+ L25
Pages of:
27/08/2019
Next Page:
9
DKAAHOD
Ala_Std_Cable_ConForm_ALTC_External_Rev3
42
Page: 2.a
2.b
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
2.a
External targets Internal targets
DKAAHOD
25/07/2019
0
(B3)
=SI+L25-W14
=OFB-LCP
Project
5
27
&SCH/25.1
6
28
28
JLE
Created By
Cable-connection diagram
2
19-Feb-2019
=SI+L25-W15
7
29
29
&SCH/25.1
8
30
30
Master Versions:
4
conductor
=OFB-LCP -X8
5
9
57
57
&SCH/25.1
10
58
58
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
11
59
59
12
60
60
6
13
61
61
14
62
62
=SI+L25-W16
57
9
15
63
63
Cable-connection diagram
16
64
64
7
=SI+L25-W14 =SI+L25-W15
17
65
18
66
19
67
20
68
105X03: 092144
8
Pages of:
27/08/2019
Next Page:
9
DKAAHOD
Ala_Std_Cable_ConForm_ALTC_External_Rev3
42
2.c
Page: 2.b
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
2.b
External targets Internal targets
DKAAHOD
25/07/2019
0
=SI+L25-W18
=EGCS-EGCS
Project
1
9
9
&SCH/24.4
2
10
10
JLE
Created By
Cable-connection diagram
2
19-Feb-2019
OK to start (E1)
=SI+L25-W19
3
11
11
11
&SCH/24.4
4
12
12
Master Versions:
4
conductor
=EGCS-EGCS -X8
5
7
17
17
&SCH/24.4
8
18
18
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
=SI+L25-W23
=SI+L25-W24
conductor
=EGCS-EGCS -X8
Cable-connection diagram
7
=SI+L25-W22 =SI+L25-W23
=SI+L25-W18 =SI+L25-W19
11
19
19
11
&SCH/24.4
12
20
20
105X03: 092144
8
conductor
= SI
-X8
+ L25
=EGCS-EGCS
Pages of:
27/08/2019
Next Page:
9
39
13
39
39
13
DKAAHOD
Ala_Std_Cable_ConForm_ALTC_External_Rev3
&SCH/24.4
42
Page: 2.c
2.d
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
2.c
External targets Internal targets
DKAAHOD
25/07/2019
0
=SI+L25-W24
=EGCS-EGCS
Project
14
40
40
JLE
16
42
42
Created By
Cable-connection diagram
2
17
43
43
18
44
44
19-Feb-2019
19
45
45
20
46
46
21
47
47
40
22
48
48
14
23
49
49
Master Versions:
24
50
50
4
25
51
51
26
52
52
28
54
5
29
55
30
56
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
=SI+L25-W25
conductor
=AMS-AMS -X8
Cable-connection diagram
1
75
75
7
=SI+L25-W24 =SI+L25-W25
&SCH/37.1
2
76
76
3
77
77
4
78
78
5
75
79
105X03: 092144
8
7
81
8
82
= SI
+ L25
Pages of:
27/08/2019
Next Page:
83
9
DKAAHOD
Ala_Std_Cable_ConForm_ALTC_External_Rev3
42
2.e
Page: 2.d
This document and its contents is owned by Alfa Laval AB (publ.) or its affiliates and protected by laws governing intellectual property and thereto related rights.
Without limiting any rights related to this document, no part of this document may be copied, reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise),
or for any purpose, without the expressed permission of Alfa Laval. Nor may it be used in any other way or for any other purpose than expressly permitted by Alfa Laval.
Revision 2
Alfa Laval will enforce its rights related to this document to the fullest extent of the law, including the seeking of criminal prosecution.
F
E
B
C
A
G
D
2.d
External targets Internal targets
DKAAHOD
25/07/2019
0
=SI+L25-W25
=AMS-AMS
Project
84
10
84
10
JLE
Created By
Cable-connection diagram
2
19-Feb-2019
Master Versions:
4
Gasvaerksvej 21
9000 Aalborg DK
Alfa Laval Aalborg
6
=SI+L25-W25
Cable-connection diagram
7
105X03: 092144
8
Pages of:
27/08/2019
Next Page:
9
DKAAHOD
Ala_Std_Cable_ConForm_ALTC_External_Rev3
42
Page: 2.e