Pressure surges during Auto filter


back-flushing,
Service letter
EXTERNAL REF. EXTERNAL REF. CLEAN MARINE PROJECT CM DOCUMENT NO.:
NUMBER:

1042-1047-EPS
Pressure surges during Auto filter Document ID:
back-flushing,
Service letter Page 2 of 3 Rev. no: 1

TABLE OF CONTENTS
Technical specification................................................................................................................................................. 3
Ships affected ............................................................................................................................................................... 3
Modification ................................................................................................................................................................... 3
Pressure surges during Auto filter Document ID:
back-flushing,
Service letter Page 3 of 3 Rev. no: 1

Technical specification

HYDAC Process Technologies GmbH Sea Water Auto filter,


Model number: All models

Ships affected
This document is valid for all scrubbers equipped with HYDAC Auto filters.

Modification

Pressure surges occur during the back-flushing process that could damage
the pipeline system or downstream units. This can be reduced by throttling
the flow of exhaust air with the aid of the exhaust air needle valve attached
to the back-flushing valve.

The closing time of the back-flushing valve can be changed by the exhaust flow control
valve. The exhaust flow control valve is located on the solenoid valve on of the back-
flushing valve.

Additionally, instructions from the Maker according to the back-flushing valve mounting
should be followed.