Type: AVA 33

VOLTAGE OPERATED AUXILIARY RELAY


(3 ELEMENTS) WITH HR CONTACTS
ASHIDA
Features :
• Contacts conform to IS: 3231. Duty: 1250VA.
Type : AVA33 Sr. No. :03JH001 Contact : 4NO-4NO-3NO VOL. :110 VDC
• Attracted armature type compact design with
positive action.
• Din Standard size compact cabinet.
• Three Independent elements in Single Cabinet.

Application :
• High speed tripping duties.
• To multiply the contacts of protection.
White : Normal • Low burden sensitive relay.
Red : Alarm. Reset Reset Reset

9 19 27

A B C
Panel Cut-out : 186 x 92mm, Bezel: 203 x 110mm

10 20 28

Internal Wiring Dig.


Contacts Rating :
Make and Carry Make and Carry For 3 Sec. Break
AC 1250VA with max. of 5A & 7500VA with max. of 30A & 1250VA with max. of 5A &
660Volts. 660Volts. 660Volts.
DC 1250 W with max. of 5A & 7500 W with max. of 30A & 100 W Resistive,
660Volts. 660Volts. 50 W Inductive 5A / 660V.

Operation :
Three independent relay elements are housed in one cabinet. The coil of each element is directly brought on
terminals 9, 10(element A), 19, 20(element B) and 27, 28(Element C). After applying energizing voltage at these
terminals, the relay operates and NO contact closes and NC contact opens. The Contacts are available as Hand
Reset (HR) type only. Relays are available with or without flags and AC or DC coil.

Technical Specifications:
Sr. No. Specification Particulars
I. Operational Limits : 70 to 110 % of rated coil voltage.
II. Operational Time : 20 - 25ms at nominal rated voltage.
III. Coil Rating : 24V / 30V / 110V / 220V, DC / AC.
IV. Burden : @ 30 VDC / 24VDC : 3 VA, @110 VDC : 2 VA, @220VDC : 4 VA.
V. Operational Indicator : Mechanical Flag (Red for Alarm, White for Normal) in window : HR Type.
VI. Contacts : 4 Pair of HR (Hand Reset) Each.
VII. Combinations : 4NO, 3NO + 1NC, 2NO + 2NC, 1NO + 3NC for A & B elements. Only 3
pairs of contacts on element C in 3NO, 2NO + 1NC, or 3NC combination
( Ref. : Drawing AXL00301 & AXL00401 ).
VIII. Relay conforms : IS : 3231 -1981 fully for all requirements.
IX. Drawing Reference : For Cabinet Type - MAC00301 (CSC - H - 120).
: For Electrical Connection - AXL00301 & AXL00401.

For Ordering specify Coil Voltage (AC or DC) and TB No.

Note: Due to our policy to upgrade our products constantly, we reserve the right to supply products which may vary
slightly from that indicated above.

ASHIDA ELECTRONICS PVT LTD.


Plot No. A-308, Road No. 21,
Wagle Industrial Estate, Ref.: AVA33
Thane (W)-400 604. INDIA. Issue : 08 Dt : 29.12.03
E-mail: sales@ashidaelectronics.com
Page 1/1
Web: www.ashidaelectronics.com

You might also like