You are on page 1of 12

© Samsung Electronics

History
Date S/W Ver. Detail Remark
[Common]
- Limit the report issue
[Designer]
2021.08.23 2.0.0.36
- Specify the room continuously
- Change the color of an object made via the Drawing function
- Add commands and shortcut keys
[Sales]
- Multi-selection function of the controller
2021-11-08 2.0.0.47
[Designer]
- Check the indoor unit’s total capacity under drain pipe

© Samsung Electronics
v2.0.0.47

© Samsung Electronics
[Sales] Multi-selection function of the controller
■ Multi-selection function of the controller
- When selecting multiple outdoor/indoor dummy boxes, compatible controllers are displayed in the controller list.
. Only controllers that can be designed with selected dummy boxes are displayed.

- Multiple selections of dummy boxes can be made through the keyboard Ctrl key or mouse drag.
1. Keyboard Ctrl key : You can select the controller by selecting only the desired dummy box.
2. Mouse drag : After dragging as many areas as you want,
you can select a controller by leaving only a specific dummy box through a filtering function in the property tap.

Keyboard Ctrl key Mouse drag

1
3
2 1
2
3

5 4

© Samsung Electronics
[Designer] Check the indoor unit’s total capacity under drain pipe
■ Check the indoor unit’s total capacity under drain pipe
- If you select the drain pipe,
you can check the sum of the rated capacities of the indoor units that are connected lower part of the drain pipe in the property tap.
. You can check it after completing the system check result of the drain pipe system normally.

© Samsung Electronics
v2.0.0.36

© Samsung Electronics
[Common] Limit the report issue
■ Limit the report issue_Sales mode
- The report can be issued only after System check result is normal("Ok") about Equipment/Piping and Wiring/Controller tap.
. The report can't be issued if there is any NG or there is a system that didn’t do system check between Equipment/Piping and Wiring/Controller tap.

- According to System check type, "System check error status" pop-up might be displayed.
1. Current System : If there is a system no more than 1 that didn't do System check function,
Wiring/Controller System check will proceed automatically and display “System check error status" pop-up.
2. All Systems : System check will proceed about Equipment/Piping and Wiring/Controller. and "System check error status" pop-up will be displayed.
3. Real Time Check : It doesn't display "System check error status" pop-up.
* If System check result of Equipment/Piping and Wiring/Controller all is normal, "System check error status" pop-up is not displayed.

In "System check error status" pop-up,


- Equipment/Piping : Can check only system list that occurred error
- Wiring/Controller : Can check error message The report can't be issued until the result of System check about all systems is normal.

© Samsung Electronics
[Common] Limit the report issue
■ Limit the report issue_Designer mode
- If the result of System check about Refrigerant or Drain piping is NG, the caution phrase will be marked when users issue the report.
. The report can be issued. But, it has a caution phrase because it is not the correct report.
. A caution phrase is marked in the report in drawing and Excel/PDF report all.
Ex) The report in drawing

Ex) Excel/PDF report

© Samsung Electronics
[Designer] Specify the room continuously
■ Specify the room continuously
- Rooms can be specified continuously via using Enter/Space key. (Execute a previous command)
1. Specify a room on the drawing after select a specific room in the Building tap as previously
2. If a specific room was done specifying on the drawing, it will be selected the next room automatically in the "Building" tap.
3. At the time, the next room can be done specifying on the drawing via Enter/Space key.
* The next room will be selected automatically in order based on the room that select first.

3 5
1
6
4

If "Room 2" is done specifying on the drawing, If "Room 3" is done specifying on the drawing via Enter/Space key,
“Room 3" will be selected automatically in the "Building" tap. "Room 4" will be selected automatically in the "Building" tap.

© Samsung Electronics
[Designer] Color change of the Drawing function object
■ Change the color of an object made via the Drawing function
- It can be changed according to select the color in the color combo box after selecting the object that wants to change the color.
. In the case of "Block", it can be changed the color only for the block that set the layer as "by block".

1 2

© Samsung Electronics
[Designer] Add commands and shortcut keys
■ Add commands and shortcut keys
- Added shortcut keys about functions that have command previously only.
- Add 4 new commands and shortcut keys
Page 1 Page 2 Page 3 Function Command Shortcut Remark Page 1 Page 2 Page 3 Function Command Shortcut Page 1 Page 2 Page 3 Function Command Shortcut
New NEW N Make Default DvmDrawReport RP Open OPEN OP
Project Set Drawing DvmSetBackground SB New Floor Height Line DvmDrawRptFloorLine RFD Save SAVE SV
HOME Equipment DvmDrawRptPipeAll RPA Save as SAVEAS SVS
Export EXPORT EP Quick Access Toolbar
Vertical pipe DvmDrawRptDrain RPD Print PLOT PLT
Management Equipment Name DvmReplaceName RN
Piping Diagram Drain pipe DvmDrawRptDrainJoin RPJ Cancel UNDO U
Management DvmSpaceManager SM New Annotate Refrigerant Piping DvmDrawRptPipeTag RPT Redo REDO RR
Specify floor DvmSetFloorEachArea SFA Legend DvmDrawRptPipeLegend RPL
Building Specify all floors DvmSetFloorBlocArea SBA Sales Type DvmDrawRptSalesType RST
Specify the room DvmSetRoomEachArea SRA Report Floor Height Line DvmDrawRptFloorLine RFD
Equipment DvmDrawRptWireAll RWA
Delete DvmDeleteSpace SDL
Indoor Unit Power Wire DvmDrawRptPower RWD
System Color DvmChangeSystemColor CSC
Power Indoor Unit Power Wiring DvmDrawRptPowerJoin RWJ
Emphasize on the current system DvmHighlightSystem SH Communication Outdoor unit Power Wire DvmDrawRptPowerTag RPP
New DvmNewSystem SN New Diagram Outdoor Unit Communication Wire DvmDrawRptTransTag RTT
Delete DvmDeleteSystem SD New Wired Controller (Manual) DvmDrawRptRc RRD
System Wired Remote Controller (Auto) DvmDrawRptRcAll RRA
Check DvmCheckPiping SCP
Legend DvmDrawRptControlLegend RCL
Switch DvmSwitchSystem SSW
Line LINE L
Separation DvmSplitSystem SSP
Polyline POLYLINE PL
Merge DvmMergeSystem SMG Rectangle RECTANGLE RECT
Drawing
Indoor Auto Selection DvmAutoSelIndoor IDA Circle CIRCLE C
Equipment
Outdoor Spacing DvmOutdoorSpacing ODS Text TEXT T
Manual DvmDrawLiquid DPW Block INSERT I
Ribbon Ribbon Erase ERASE E
Automatic DvmDrawAutoLiquid DPA
Piping Copy COPY CP
PIT DvmDrawPit DPD
Design Move MOVE M
PIT Sequence DvmCmdPitOrder DPO Rotation ROTATE RO
Check DvmCheckDrain SCD Stretch STRETCH S
Drawing
Manual DvmDrawDrain DDD Modify Cut TRIM TR
Automatic DvmDrawAutoDrain DDA Extend EXTEND EX
Offset OFFSET O
Drain Pipe Vertical pipe DvmDrawDrainPit DDP
Scale SCALE SC
TEE DvmDrawDrainTee DDT
Disassemble EXPLODE X
CAP DvmDrawDrainCap DDC Fillet FILLET F
Drainage DvmDrawDrainHole DDH Paste PASTECLIP CPT
Piping DvmDrawPipeMark DPM Clipboard Cut CUTCLIP CCT
Drain Pipe DvmDrawDrainMark DDM Copy COPYCLIP CCP
Distance DIST DI
PIT DvmDrawPitMark DTM Measurement
Annotation/Legend Area AREA AA
Direction Change DvmChangeMark CDM
Screen Magnification ZOOM Z
Erase DvmEraseMark ERM Zoom In ZOOMIN ZI
Legend DvmDrawLegendMark DML Zoom In/Out Zoom Out ZOOMOUT ZO
Communication Wiring DvmDrawTransLine DTR Space Expansion ZOOMRECT ZR
View
Communication Wiring Wired Remote Controller DvmSelectRc DRS Fit to Window ZOOMALL ZA
Layer LAYER LA
Wired Remote Controller Draw DvmDrawPowerLine DRM
Show/Hide Layer off LAYEROFF LOF
Set Object Color DvmChangeObjectColor DCO
Object DvmShowObject SO
© Samsung Electronics
[Designer] Add commands and shortcut keys
■ Add commands and shortcut keys
- In the "Shortcut Key" page of Configuration, if "Reset Default" is clicked, shortcut keys will be input about all commands.
. But, shortcut keys that were made previously should be set again due to reset.

1
2

© Samsung Electronics

You might also like